Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
World J Surg Oncol ; 20(1): 306, 2022 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-36153542

RESUMEN

This article is a response to "comment on 'Pooled analysis of Xpert bladder cancer based on the 5 mRNAs for rapid diagnosis of bladder carcinoma'" by Gopal Sharma. With this comment, author highlighted the strengths and limitations of the study. With this response, we respond to this and make a comparison of the results and conclusions.


Asunto(s)
Carcinoma , Neoplasias de la Vejiga Urinaria , Humanos , ARN Mensajero/genética , Vejiga Urinaria , Neoplasias de la Vejiga Urinaria/diagnóstico , Neoplasias de la Vejiga Urinaria/genética
2.
Biochem Genet ; 60(6): 2052-2068, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35235083

RESUMEN

Severe Acute Respiratory Syndrome Coronavirus Type 2 (SARS-CoV-2) is an enveloped single-stranded RNA virus that can lead to respiratory symptoms and damage many organs such as heart, kidney, intestine, brain and liver. It has not been clearly documented whether myocardial injury is caused by direct infection of cardiomyocytes, lung injury, or other unknown mechanisms. The gene expression profile of GSE150392 was obtained from the Gene Expression Omnibus (GEO) database. The processing of high-throughput sequencing data and the screening of differentially expressed genes (DEGs) were implemented by R software. The R software was employed to analyze the Gene Ontology (GO) analysis and the Kyoto Encyclopedia of Genes and Genomes (KEGG) analysis. The protein-protein interaction (PPI) network of the DEGs was constructed by the STRING website. The Cytoscape software was applied for the visualization of PPI network and the identification of hub genes. The statistical analysis was performed by the GraphPad Prism software to verify the hub genes. A total of 516 up-regulated genes and 191 down-regulated genes were screened out. The top 1 enrichment items of GO in biological process (BP), Cellular Component (CC), and Molecular Function (MF) were type I interferon signaling pathway, sarcomere, and receptor ligand activity, respectively. The top 10 enrichment pathways, including TNF signaling pathway, were identified by KEGG enrichment analysis. A PPI network was established, consisting of 613 nodes and 3,993 edges. The 12 hub genes were confirmed as statistically significant, which was verified by GSE151879 dataset. In conclusion, the hub genes of human iPSC-cardiomyocytes infected with SARS-CoV-2 were identified through bioinformatics analysis, which may be used as biomarkers for further research.


Asunto(s)
COVID-19 , Células Madre Pluripotentes Inducidas , Humanos , SARS-CoV-2 , Perfilación de la Expresión Génica , Miocitos Cardíacos , COVID-19/genética , Biología Computacional , Transducción de Señal/genética
3.
Jpn J Infect Dis ; 75(2): 183-191, 2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-34053954

RESUMEN

Xpert Xpress Flu/RSV is a fast and automated real-time nucleic acid amplification tool for detecting influenza virus and respiratory syncytial virus (RSV). The aim of this study was to verify the accuracy of Xpert Xpress Flu/RSV for detecting influenza virus and RSV. PubMed, EMBASE, Cochrane Library, and Web of Science databases were searched up to October 2020. The quality of the original research was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 guidelines. Meta-DiSc 1.4 software was used to analyze the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and summary receiver operating characteristic curve. Deek's funnel plot asymmetry test was used to evaluate the publication bias using the Stata 12.0 software. Ten studies with 25 fourfold tables were included in the analysis. The sensitivity of Xpert Xpress Flu/RSV for detecting influenza A, influenza B, and RSV were 0.97, 0.98, and 0.96, respectively, and the specificities were 0.97, 1.00, and 1.00, respectively. Compared with other common clinical real-time reverse transcription-polymerase chain reaction (RT-PCR), Xpert Xpress Flu/RSV is a valuable tool for diagnosing influenza virus and RSV with high sensitivity and specificity.


Asunto(s)
Virus de la Influenza A , Gripe Humana , Infecciones por Virus Sincitial Respiratorio , Virus Sincitial Respiratorio Humano , Humanos , Virus de la Influenza A/genética , Virus de la Influenza B/genética , Gripe Humana/diagnóstico , Técnicas de Diagnóstico Molecular , Nasofaringe , Infecciones por Virus Sincitial Respiratorio/diagnóstico , Virus Sincitial Respiratorio Humano/genética , Sensibilidad y Especificidad
4.
PLoS Negl Trop Dis ; 15(11): e0009869, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34748586

RESUMEN

PURPOSE: Vancomycin-resistant enterococci infection is a worrying worldwide clinical problem. To evaluate the accuracy of GeneXpert vanA/vanB in the diagnosis of VRE, we conducted a systematic review in the study. METHODS: Experimental data were extracted from publications until May 03 2021 related to the diagnostic accuracy of GeneXpert vanA/vanB for VRE in PubMed, Embase, Web of Science and the Cochrane Library. The accuracy of GeneXpert vanA/vanB for VRE was evaluated using summary receiver to operate characteristic curve, pooled sensitivity, pooled specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio. RESULTS: 8 publications were divided into 3 groups according to two golden standard references, vanA and vanB group, vanA group, vanB group, including 6 researches, 5 researches and 5 researches, respectively. The pooled sensitivity and specificity of group vanA and vanB were 0.96 (95% CI, 0.93-0.98) and 0.90 (95% CI, 0.88-0.91) respectively. The DOR was 440.77 (95% CI, 37.92-5123.55). The pooled sensitivity and specificity of group vanA were 0.86 (95% CI, 0.81-0.90) and 0.99 (95% CI, 0.99-0.99) respectively, and those of group vanB were 0.85 (95% CI, 0.63-0.97) and 0.82 (95% CI, 0.80-0.83) respectively. CONCLUSION: GeneXpert vanA/vanB can diagnose VRE with high-accuracy and shows greater accuracy in diagnosing vanA.


Asunto(s)
Proteínas Bacterianas/genética , Ligasas de Carbono-Oxígeno/genética , Infecciones por Bacterias Grampositivas/diagnóstico , Infecciones por Bacterias Grampositivas/microbiología , Enterococos Resistentes a la Vancomicina/aislamiento & purificación , Antibacterianos/farmacología , Proteínas Bacterianas/metabolismo , Ligasas de Carbono-Oxígeno/metabolismo , Humanos , Sensibilidad y Especificidad , Vancomicina/farmacología , Enterococos Resistentes a la Vancomicina/clasificación , Enterococos Resistentes a la Vancomicina/efectos de los fármacos , Enterococos Resistentes a la Vancomicina/genética
5.
Ann Clin Microbiol Antimicrob ; 20(1): 62, 2021 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-34488790

RESUMEN

BACKGROUND: Group B Streptococcal (GBS) infection is the primary agent of neonatal morbidity and mortality. Rapid and simple methods to detect GBS are Xpert GBS and GBS LB assays based on real-time polymerase chain reaction (PCR). However, since the diagnostic accuracy of the two techniques in diagnosing GBS remains unclear, we designed this study to appraise the diagnostic accuracy of the aforementioned. METHODS: A systematic search of all literature published before July 16, 2020 was conducted using Embase, PubMed, Web of Science, and Cochrane Library. The study quality was evaluated through Review Manager 5.3. Accordingly, data extracted in the included studies were analyzed using Meta-DiSc 1.4 and Stata 12.0 software. The diagnosis odds ratio (DOR) and bivariate boxplot were utilized to evaluate the heterogeneity. Publication bias was appraised by using Deeks' funnel plot. RESULTS: A total of 13 studies were adopted and only 19 sets of data met the criteria. The sensitivity and specificity of Xpert GBS were 0.91 (95% CI 0.89-0.92) and 0.93 (95% CI 0.92-0.94). The area under the curve (AUC) was 0.9806. The sensitivity and specificity results of Xpert GBS LB were 0.96 (95% CI 0.95-0.98) and 0.94 (95% CI 0.92-0.95), respectively. The AUC was 0.9950. No publication bias was found. CONCLUSIONS: The Xpert GBS and GBS LB assays are valuable alternative methods with high sensitivity and specificity. However, determining whether they can be used as clinical diagnostic standards for GBS is essential for the future.


Asunto(s)
Técnicas Bacteriológicas/métodos , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Infecciones Estreptocócicas/diagnóstico , Streptococcus agalactiae/aislamiento & purificación , Humanos , Recién Nacido , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Infecciones Estreptocócicas/microbiología , Streptococcus agalactiae/genética
6.
PLoS Negl Trop Dis ; 15(8): e0009633, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34347790

RESUMEN

Dengue fever virus (DENV) is a global health threat that is becoming increasingly critical. However, the pathogenesis of dengue has not yet been fully elucidated. In this study, we employed bioinformatics analysis to identify potential biomarkers related to dengue fever and clarify their underlying mechanisms. The results showed that there were 668, 1901, and 8283 differentially expressed genes between the dengue-infected samples and normal samples in the GSE28405, GSE38246, and GSE51808 datasets, respectively. Through overlapping, a total of 69 differentially expressed genes (DEGs) were identified, of which 51 were upregulated and 18 were downregulated. We identified twelve hub genes, including MX1, IFI44L, IFI44, IFI27, ISG15, STAT1, IFI35, OAS3, OAS2, OAS1, IFI6, and USP18. Except for IFI44 and STAT1, the others were statistically significant after validation. We predicted the related microRNAs (miRNAs) of these 12 target genes through the database miRTarBase, and finally obtained one important miRNA: has-mir-146a-5p. In addition, gene ontology (GO) and the Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway enrichment were carried out, and a protein-protein interaction (PPI) network was constructed to gain insight into the actions of DEGs. In conclusion, our study displayed the effectiveness of bioinformatics analysis methods in screening potential pathogenic genes in dengue fever and their underlying mechanisms. Further, we successfully predicted IFI44L and IFI6, as potential biomarkers with DENV infection, providing promising targets for the treatment of dengue fever to a certain extent.


Asunto(s)
Biología Computacional , Dengue/genética , Biomarcadores , Redes Reguladoras de Genes , Humanos , Mapas de Interacción de Proteínas
7.
Biomed Res Int ; 2021: 5527505, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34055977

RESUMEN

BACKGROUND: West Africa has witnessed the unprecedented outbreak of Ebola virus disease (EVD). The Ebola virus (EBOV) can cause Ebola hemorrhagic fever, which is documented as the most deadly viral hemorrhagic fever in the world. RT-PCR had been suggested to be employed in the detection of Ebola virus; however, this method has high requirements for laboratory equipment and takes a long time to determine Ebola infection. Although Xpert Ebola is a fast and simple instrument for the detection of Ebola virus, its effect is still unclear. This study is aimed at evaluating the accuracy of Xpert Ebola in diagnosing Ebola virus infection. METHODS: Using the keywords "Xpert" and "Ebola virus", relevant studies were retrieved from the database of PubMed, Embase, Web of Science, and Cochrane. RT-PCR was employed as a reference standard to evaluate whether the study is eligible to be included in the meta-analysis. Data from these included studies were extracted by two independent assessors and were then analyzed by the Meta-DiSc 1.4 software to produce the heterogeneity of sensitivity (SEN), specificity (SP), positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic advantage ratio (DOR) of the study. The results of pooled analysis were plotted, together with the summary receiver operating characteristic (SROC) curve plotted by calculating the area under the curve (AUC). Generated pooled summary estimates (95% CIs) were calculated for the evaluation of the overall accuracy of this study. RESULTS: Five fourfold tables were made from the four studies that were included in the meta-analysis. The pooled sensitivity of Xpert Ebola was 0.98 (95% confidence interval (CI) (0.95, 0.99)), and the pooled specificity was 0.98 (95% CI (0.97, 0.99)). The pooled values of positive likelihood ratio was 53.91 (95% CI (12.82, 226.79)), with negative likelihood ratio being 0.04 (95% CI (0.02, 0.08)) and diagnostic odds ratio being 2649.45 (95% CI (629.61, 11149.02)). The AUC was 0.9961. CONCLUSIONS: Compared with RT-PCR, Xpert Ebola has high sensitivity and specificity. Therefore, it is a valued alternative method for the clinical diagnosis of Ebola virus infection. However, the Xpert Ebola test is a qualitative test that does not provide quantitative testing of EBOV concentration. Whether it can completely replace other methods or not calls for further evidences.


Asunto(s)
Ebolavirus/aislamiento & purificación , Fiebre Hemorrágica Ebola/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , África Occidental , Animales , Área Bajo la Curva , Bases de Datos Factuales , Humanos , Oportunidad Relativa , Curva ROC , Estándares de Referencia , Sensibilidad y Especificidad
8.
Microb Pathog ; 156: 104932, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33964417

RESUMEN

BACKGROUND: Helicobacter pylori is a pathogen involved in several gastroduodenal diseases, whose infection mechanisms have not been completely confirmed. To study the specific mechanism of gastropathy caused by H. pylori, we analyzed the gene microarray of gastric mucosa and gastric cells infected by H. pylori through bioinformatics analysis. METHODS: We downloaded GSE60427 and GSE74492 from the Gene Expression Omnibus (GEO) database, screened differentially expressed genes (DEGs), and identified the Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) through R software. The Search Tool for the Retrieval of Interacting Genes (STRING) was applied to establish a protein-protein interaction (PPI) network and Cytoscape was used to identify the top seven hub genes. Besides, we also constructed the gene-microRNA(gene-miRNA) interaction through the miRTarBase v8.0 database by using the NetworkAnalyst tool. RESULTS: One hundred and fifteen DEGs were screened out, with 54 genes up-regulated and 61 genes down-regulated, among which seven hub genes, including "IGF1R," "APOE," "IRS1," "ATF3," "LCN2," "IL2RG," and "PI3," were considered as the main regulatory proteins in gastric cells when infected by H. pylori. CONCLUSION: In this study, hub genes and related signal enrichment pathways of gastropathy infected by H. pylori were analyzed through bioinformatics analysis based on the GSE60427 and GSE74492 datasets.


Asunto(s)
Helicobacter pylori , Biología Computacional , Perfilación de la Expresión Génica , Regulación Neoplásica de la Expresión Génica , Ontología de Genes , Helicobacter pylori/genética
9.
World J Surg Oncol ; 19(1): 42, 2021 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-33563292

RESUMEN

BACKGROUND: Xpert Bladder Cancer is a detection method developed in recent years, designed with the functions of integrating sample automatically, nucleic acid amplification, and target sequence detection. It is a urine assay targeting five mRNAs (CRH, IGF2, UPK1B, ANXA10, and ABL1). The purpose of this article is to review the accuracy of Xpert Bladder Cancer in the follow-up diagnosis of bladder cancer and evaluate the role of Xpert Bladder Cancer in detecting the recurrence of non-muscle-invasive bladder cancer in the round. METHODS: In the database of Embase, PubMed, Web of Science, and Cochrane Library, the articles published up to October 13, 2020, were searched and screened based on the exclusion and inclusion criteria, and data were extracted from the included studies. The sensitivity, specificity, negative likelihood ratio, positive likelihood ratio summary of receiver operating characteristic curves, and diagnostic odds ratio were combined by the Meta-DiSc 1.4 software. The Stata 12.0 software was used to obtain the assessment of publication bias. RESULTS: A total of 8 articles involving eight fourfold tables were finally identified. The pooled sensitivity and specificity of Xpert Bladder Cancer in the diagnosis of bladder cancer were 0.71 and 0.81, respectively. The positive likelihood ratio and negative likelihood ratio were 3.74 and 0.34, respectively. The area under the curve was 0.8407. The diagnostic odds ratio was 11.99. Deeks' funnel plot asymmetry test manifested no publication bias. CONCLUSIONS: In summary, Xpert Bladder Cancer presents high accuracy and specificity in monitoring bladder cancer compared with cystoscopy. More researches are still required to further confirm this conclusion.


Asunto(s)
Carcinoma , Neoplasias de la Vejiga Urinaria , Humanos , Recurrencia Local de Neoplasia/diagnóstico , Recurrencia Local de Neoplasia/genética , Pronóstico , ARN Mensajero/genética , Sensibilidad y Especificidad , Neoplasias de la Vejiga Urinaria/diagnóstico , Neoplasias de la Vejiga Urinaria/genética
10.
Biomed Res Int ; 2020: 2892734, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33102576

RESUMEN

BACKGROUND: Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) are widely spread across the world. Asymptomatic or inconspicuous CT/NG infections are difficult to diagnose and treat. Traditional methods have the disadvantages of low detection rate, inaccurate results, and long detection time. However, Xpert CT/NG makes up for the aforementioned shortcomings and has research value and popularization significance. METHODS: PubMed, Embase, Cochrane Library, and Web of Science were systematically searched, and studies were screened using Xpert CT/NG for diagnosing CT/NG. QUADAS-2 was used to evaluate the quality of the eligible studies. Then, two groups of researchers independently extracted data from these studies. Meta-analyses of sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and the area under the curve (AUC) of the summary receiver operating characteristic (SROC) curve were conducted using Meta-DiSc 1.4. Finally, Deek's funnel plots were made using Stata 12.0 to evaluate publication bias. RESULTS: 14 studies were identified, and 46 fourfold tables were extracted in this meta-analysis. The pooled SEN, SPE, PLR, NLR, DOR, and AUC in diagnosing CT were 0.94 (95% confidence interval (CI): 0.93-0.95), 0.99 (95% CI: 0.99-1.00), 97.17 (95% CI: 56.76-166.32), 0.07 (95% CI: 0.04-0.12), 1857.25 (95% CI: 943.78-3654.86), and 0.9960, respectively. The pooled SEN, SPE, PLR, NLR, DOR, and AUC in diagnosing NG were 0.95 (95% CI: 0.93-0.96), 1.00 (95% CI: 1.00-1.00), 278.15 (95% CI: 152.41-507.63), 0.08 (95% CI: 0.06-0.12), 4290.70 (95% CI: 2161.78-8516.16), and 0.9980, respectively. CONCLUSIONS: Xpert CT/NG had high diagnostic sensitivity and specificity for CT and NG. However, more evidence is required to confirm that Xpert CT/NG might serve as the primary method for detecting CT and NG and even the gold standard for diagnosis in the future.


Asunto(s)
Infecciones por Chlamydia/diagnóstico , Gonorrea/diagnóstico , Área Bajo la Curva , Infecciones por Chlamydia/microbiología , Chlamydia trachomatis/patogenicidad , Gonorrea/microbiología , Humanos , Neisseria gonorrhoeae/patogenicidad , Oportunidad Relativa , Curva ROC , Sensibilidad y Especificidad
11.
BMC Infect Dis ; 20(1): 650, 2020 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-32887568

RESUMEN

BACKGROUND: Cryptococcus is a conditional pathogenic fungus causing cryptococcosis, which is one of the most serious fungal diseases faced by humans. Lateral flow immunochromatographic assay (LFA) is successfully applied to the rapid detection of cryptococcal antigens. METHODS: Studies were retrieved systematically from the Embase, PubMed, Web of Science, and Cochrane Library before July 2019. The quality of the studies was assessed by Review Manager 5.0 based on the Quality Assessment of Diagnostic Accuracy Study guidelines. The extracted data from the included studies were analyzed by Meta-DiSc 1.4. Stata 12.0 software was used to detect the publication bias. RESULTS: A total of 15 articles with 31 fourfold tables were adopted by inclusion and exclusion criteria. The merged sensitivity and specificity in serum were 0.98 and 0.98, respectively, and those in the cerebrospinal fluid were 0.99 and 0.99, respectively. CONCLUSIONS: Compared to the urine and other samples, LFA in serum and cerebrospinal fluid is favorable evidence for the diagnosis of cryptococcosis with high specificity and sensitivity.


Asunto(s)
Criptococosis/diagnóstico , Inmunoensayo/métodos , Antígenos Fúngicos/sangre , Antígenos Fúngicos/líquido cefalorraquídeo , Antígenos Fúngicos/orina , Líquido Cefalorraquídeo/microbiología , Pruebas Diagnósticas de Rutina/métodos , Humanos , Sensibilidad y Especificidad
12.
Biomed Res Int ; 2020: 1968487, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32685449

RESUMEN

BACKGROUND: The World Health Organization approved the use of Xpert MTB/RIF for the detection of Mycobacterium tuberculosis DNA, which has significantly improved the diagnosis of tuberculosis. In this study, our main objective was to evaluate the diagnostic efficacy of Xpert MTB/RIF for lymphoid tuberculosis to determine whether Xpert MTB/RIF could be used as a routine detection method. MATERIALS AND METHODS: We searched four databases for the relevant literature published from May 2007 to December 2019. The quality of the literature was evaluated with reference to the evaluation criteria. Data that were extracted from the literature on Xpert MTB/RIF diagnosis of lymphatic tuberculosis were used to plot the summary receiver operating characteristic (SROC) curve, after which the software was used to combine and analyze the accuracy of these data. RESULTS: A total of 27 studies were included. The sensitivity of Xpert MTB/RIF for detecting lymphatic tuberculosis was 0.79 (95% CI (0.77, 0.81)), the specificity was 0.88 (95% CI (0.87, 0.90)), and the positive likelihood ratio (PLR) was 7.21 (95% CI (4.93, 10.55)). In addition, the negative likelihood ratio (NLR) was 0.25 (95% CI (0.19, 0.32)) and the diagnostic odds ratio (DOR) was 40.23 (95% CI (24.53, 65.98)). At the same time, we used the extracted data to make the SROC curve, obtaining the following parameters: area under the curve (AUC) = 0.9144, Q = 0.8470 (SE = 0.0163). CONCLUSION: Xpert MTB/RIF has high accuracy in detecting lymphatic tuberculosis, and it can be used to quickly and easily diagnose lymphatic tuberculosis at an early stage as a general method.


Asunto(s)
Mycobacterium tuberculosis/efectos de los fármacos , Técnicas de Amplificación de Ácido Nucleico/métodos , Rifampin/farmacología , Tuberculosis/diagnóstico , Humanos , Pruebas de Sensibilidad Microbiana , Sesgo de Publicación , Curva ROC
13.
Biosci Rep ; 39(10)2019 10 30.
Artículo en Inglés | MEDLINE | ID: mdl-31537628

RESUMEN

BACKGROUND: Candida is a fungus that causes various types of candidemia, which is the fourth major infectious disease of the blood system. MALDI-TOF-MS is a simple and rapid detection instrument. The aim of the present study was to verify the accuracy of MALDI-TOF-MS in detecting Candida. METHOD: A pooled analysis of articles on MALDI-TOF-MS for diagnosis of candidemia was performed. The quality of original research was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) guidelines. Stata 12.0 software was used to merge the correct identification rates of Candida and Candida subspecies and obtain pooled sensitivity and specificity of the diagnostic methods. Heterogeneity was found in the subgroup analysis of the included articles. Hence, we explored the factors causing the heterogeneity and its impact on the overall situation. Sensitivity analysis was used to examine the effect of Candida level on total response. Egger's test was used to evaluate the publication bias of the included articles. RESULTS: A total of 16 articles in Pubmed, 79 articles in Embase, 1 article in Cochrane Library, 30 articles in Web of Science and 3 from other sources were identified, of which 10 articles were included based on the inclusion and exclusion criteria. The overall identification accuracy was 100%. CONCLUSION: The accuracy of MALDI-TOF-MS for the identification of Candida was 100%. Further research is necessary to determine whether MALDI-TOF-MS can be used as a clinical diagnostic standard for the identification of Candida.


Asunto(s)
Candida/metabolismo , Candidiasis/diagnóstico , Candidiasis/metabolismo , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/clasificación , Candida/clasificación , Humanos
14.
Biosci Rep ; 39(5)2019 05 31.
Artículo en Inglés | MEDLINE | ID: mdl-30988075

RESUMEN

Streptococcus agalactiae is a major pathogenic bacterium causing perinatal infections in humans. In the present study, a novel real-time fluorescence loop-mediated isothermal amplification technology was successfully developed and evaluated for the detection of S. agalactiae in a single reaction. Six specific primers were designed to amplify the corresponding six regions of fbs B gene of S. agalactiae, using Bst DNA polymerase with DNA strand displacement activity at a constant temperature for 60 min. The presence of S. agalactiae was indicated by the fluorescence in real-time. Amplification of the targeted gene fragment was optimized with the primer 1 in the current setup. Positive result was only obtained for Sa by Real-LAMP among 10 tested relevant bacterial strains, with the detection sensitivity of 300 pg/µl. Real-LAMP was demonstrated to be a simple and rapid detection tool for S. agalactiae with high specificity and stability, which ensures its wide application and broad prospective utilization in clinical practice for the rapid detection of S. agalactiae.


Asunto(s)
ADN Bacteriano/genética , Técnicas de Amplificación de Ácido Nucleico/métodos , Infecciones Estreptocócicas/microbiología , Streptococcus agalactiae/aislamiento & purificación , Cartilla de ADN/genética , ADN Bacteriano/análisis , Fluorescencia , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Infecciones Estreptocócicas/diagnóstico , Streptococcus agalactiae/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...