Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
BMC Med ; 21(1): 461, 2023 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-37996906

RESUMEN

BACKGROUND: High-power short-duration (HPSD) ablation strategy has emerged as a popular approach for treating atrial fibrillation (AF), with shorter ablation time. The utilized Smart Touch Surround Flow (STSF) catheter, with 56 holes around the electrode, lowers electrode-tissue temperature and thrombus risk. Thus, we conducted this prospective, randomized study to investigate if the HPSD strategy with STSF catheter in AF ablation procedures reduces the silent cerebral embolism (SCE) risk compared to the conventional approach with the Smart Touch (ST) catheter. METHODS: From June 2020 to September 2021, 100 AF patients were randomized 1:1 to the HPSD group using the STSF catheter (power set at 50 W) or the conventional group using the ST catheter (power set at 30 to 35 W). Pulmonary vein isolation was performed in all patients, with additional lesions at operator's discretion. High-resolution cerebral diffusion-weighted magnetic resonance imaging (hDWI) with slice thickness of 1 mm was performed before and 24-72 h after ablation. The incidence of new periprocedural SCE was defined as the primary outcome. Cognitive performance was assessed using the Montreal Cognitive Assessment (MoCA) test. RESULTS: All enrolled AF patients (median age 63, 60% male, 59% paroxysmal AF) underwent successful ablation. Post-procedural hDWI identified 106 lesions in 42 enrolled patients (42%), with 55 lesions in 22 patients (44%) in the HPSD group and 51 lesions in 20 patients (40%) in the conventional group (p = 0.685). No significant differences were observed between two groups regarding the average number of lesions (p = 0.751), maximum lesion diameter (p = 0.405), and total lesion volume per patient (p = 0.669). Persistent AF and CHA2DS2-VASc score were identified as SCE determinants during AF ablation procedure by multivariable regression analysis. No significant differences in MoCA scores were observed between patients with SCE and those without, both immediately post-procedure (p = 0.572) and at the 3-month follow-up (p = 0.743). CONCLUSIONS: Involving a small sample size of 100 AF patients, this study reveals a similar incidence of SCE in AF ablation procedures, comparing the HPSD strategy using the STSF catheter to the conventional approach with the ST catheter. TRIAL REGISTRATION: Clinicaltrials.gov: NCT04408716. AF = Atrial fibrillation, DWI = Diffusion-weighted magnetic resonance imaging, HPSD = High-power short-duration, ST = Smart Touch, STSF = Smart Touch Surround Flow.


Asunto(s)
Técnicas de Ablación , Fibrilación Atrial , Ablación por Catéter , Embolia Intracraneal , Humanos , Masculino , Persona de Mediana Edad , Femenino , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Estudios Prospectivos , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/epidemiología , Embolia Intracraneal/prevención & control , Incidencia , Técnicas de Ablación/efectos adversos , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
2.
Expert Opin Drug Saf ; 20(11): 1411-1420, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34214005

RESUMEN

OBJECTIVE: Levosimendan, an inotrope, is widely used in the management of heart failure (HF) and cardiac surgery, but it remains uncertain whether levosimendan can improve renal function in patients with left ventricular dysfunction (LVD). METHODS: PubMed, Embase, and Cochrane CENTRAL from the inception to June 2020 were systematically screened for randomized controlled trials (RCTs) to investigate whether levosimendan offers kidney-related advantages in cardiovascular patients with LVD. We pooled the effects using a random-effect model. RESULTS: Twenty-eight studies enrolling 5069 patients were included. Levosimendan reduced the sCr (SMD -0.28, 95% CI (-0.48, -0.09), P = 0.005, I2 = 52.5%, high quality) and the risk of ARF (relative risk 0.75, 95%CI (0.60, 0.95), P = 0.017, I2 = 11.3%, moderate-quality) in patients with LVD compared with control group. The reduction of sCr was more pronounced in patients with a relatively higher baseline sCr level. For secondary outcomes, levosimendan therapy was associated with the improvement of GFR (SMD 0.32, 95%CI (-0.05, 0.68), P = 0.092, I2 = 55.1%, low-quality) and urine output (SMD 0.42, 95%CI (0.06, 0.79), P = 0.024, I2 = 50.0%, very low-quality), but there was no significant reduction in BUN (SMD -0.14, 95%CI (-0.97, 0.70), P = 0.774, I2 = 77.9%, very low-quality). CONCLUSIONS: Levosimendan might improve renal function of patients with LVD.


Asunto(s)
Cardiotónicos/administración & dosificación , Simendán/administración & dosificación , Disfunción Ventricular Izquierda/tratamiento farmacológico , Cardiotónicos/farmacología , Tasa de Filtración Glomerular , Humanos , Riñón/efectos de los fármacos , Riñón/metabolismo , Pruebas de Función Renal , Ensayos Clínicos Controlados Aleatorios como Asunto , Simendán/farmacología , Disfunción Ventricular Izquierda/fisiopatología
3.
J Cardiovasc Pharmacol ; 77(6): 805-813, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34001722

RESUMEN

ABSTRACT: Levosimendan, a calcium sensitizer, exerts inotropic action through improving left ventricular ejection fraction. We noticed that only few clinical studies are published in which the effects of levosimendan on cardiac function are studied by echocardiography. When screening the literature (PubMed, Embase, and CENTRAL, from inception to August 2020), we found 29 randomized controlled trials on levosimendan containing echocardiographic data. We included those studies, describing a total of 574 heart failure patients, in our meta-analysis and extracted 14 ultrasonic parameters, pooling the effect estimates using a random-effect model. Our analysis of the diastolic parameters of the left ventricle shows that levosimendan reduce the early/late transmitral diastolic peak flow velocity ratio [standardized mean difference (SMD) -0.45 to 95% confidence interval (CI) (-0.87 to -0.03), P = 0.037] and E/e' (e': mitral annulus peak early diastolic wave velocity using tissue-doppler imaging) [SMD -0.59, 95% CI (-0.8 to -0.39), P < 0.001]. As it regards the systolic parameters of the right ventricle, levosimendan increased tricuspid annular plane systolic excursion [SMD 0.62, 95% CI (0.28 to 0.95), P < 0.001] and tricuspid annular peak systolic velocity [SMD 0.75, 95% CI (0.35 to 1.16), P < 0.001], and reduced systolic pulmonary artery pressure [SMD -1.02, 95% CI (-1.32, -0.73), P < 0.001]. As it regards the diastolic parameters of the right ventricle, levosimendan was associated with the decrease of Aa (peak late diastolic tricuspid annular velocity using tissue-doppler imaging) [SMD -0.38, 95% CI (-0.76 to 0), P = 0.047] and increase of Ea (peak early diastolic tricuspid annular velocity using tissue-doppler imaging) [SMD 1.03, 95% CI (0.63 to 1.42), P < 0.001] and Ea/Aa [SMD 0.86, 95% CI (0.18 to 1.54), P = 0.013]. We show that levosimendan is associated with an amelioration in the diastolic and systolic functions of both ventricles in heart failure patients.


Asunto(s)
Cardiotónicos/farmacología , Insuficiencia Cardíaca/tratamiento farmacológico , Simendán/farmacología , Diástole/efectos de los fármacos , Ecocardiografía , Insuficiencia Cardíaca/fisiopatología , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto , Volumen Sistólico/efectos de los fármacos , Sístole/efectos de los fármacos , Función Ventricular Izquierda/efectos de los fármacos , Función Ventricular Derecha/efectos de los fármacos
4.
Pacing Clin Electrophysiol ; 44(2): 225-234, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33372697

RESUMEN

BACKGROUND: Current guidelines did not provide recommendations on indications of an additional implantable cardioverter-defibrillator (ICD) to patients receiving cardiac resynchronization therapy (CRT), and it still remains controversial due to lack of evidence from randomized controlled trials. METHOD: PubMed, Embase, and Cochrane CENTRAL from the inception to May 2020 were systematically screened for studies reporting on the comparison of cardiac resynchronization therapy with defibrillator (CRT-D) and cardiac resynchronization therapy with pacemaker (CRT-P), focusing on the adjusted hazard ratio (aHR) of all-cause mortality. We pooled the effects using a random-effect model. RESULTS: Twenty-one studies encompassing 69,919 patients were included in this meta-analysis. With no restriction to characteristics of including population, CRT-D was associated with a lower all-cause mortality compared with CRT-P significantly (aHR: 0.80, 95% confidence interval [CI]: 0.74-0.87, I2  = 36.8%, p < .001). This mortality benefit was also observed in patients with ischemic cardiomyopathy (aHR: 0.74, 95% CI: 0.64-0.86, I2  = 0%, p < .001). However, there is no significant difference in patients with nonischemic cardiomyopathy (NICM) (aHR: 0.91, 95% CI: 0.82-1.01, I2  = 0%, p = .087), older age (age ≥75 years, aHR: 0.96, 95% CI: 0.83-1.12, I2  = 0%, p = .610). Subgroup analysis was performed and indicated the survival benefit of CRT-D for primary prevention compared with CRT-P (aHR: 0.87, 95% CI: 0.79-0.95, I2  = 0%, p = .003). CONCLUSION: After adjusted the differences in clinical characteristics, additional ICD therapy was associated with a reduced all-cause mortality in patients receiving CRT. However, our work suggested that additional ICD may not be applied to elderly (≥75 years) or patients with NICM.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Humanos
5.
J Interv Cardiol ; 2020: 4075792, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33214775

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR), widely used as an alternative therapy in patients with severe aortic stenosis, is expected to be offered to low-risk patents with a longer life expectancy. The durability of transcatheter aortic valve is becoming of increasing importance. METHOD: PubMed, Embase, and Cochrane CENTRAL from the inception to March 2020 were systematically screened for studies reporting on structural valve deterioration (SVD) in TAVR patients. Incidence of SVD was diagnosed according to the latest European consensus as the primary end point. Predictors of SVD evaluated at multivariable analysis and cumulative incidence function (CIF) of SVD were the secondary end point. RESULT: Twelve studies encompassing 10031 patients evaluating the incidence of SVD were included, with a follow-up between 1 and 8 years. The pooled incidence of SVD was 4.93% (95% CI, 2.75%-7.70%, I 2 = 96%) at 1 year and 8.97% (95% CI, 6.89%-11.29%, I 2 = 86%) in the long term (≥5 years). Subgroup analysis was performed to identify the valve type that may result in partial heterogeneity. SVD was more frequent in patents with a valve diameter of <26 mm (HR: 3.57, 1.47-8.69), oral anticoagulants (OAC), exposure at discharge (OR: 0.48, 0.38-0.61), or by a disease of renal dysfunction (OR 1.42, 1.03-1.96). CONCLUSION: SVD represents infrequent events after TAVR in the long term (>5 years), occurring more commonly in renal dysfunction patients, with small valve diameter and without OAC exposure. There may be an underestimation of the incidence if we assume death as a competing risk.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Efectos Adversos a Largo Plazo , Falla de Prótesis/efectos adversos , Humanos , Incidencia , Efectos Adversos a Largo Plazo/epidemiología , Efectos Adversos a Largo Plazo/etiología , Insuficiencia Renal/epidemiología , Medición de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
7.
Ultrasound Med Biol ; 39(11): 2001-10, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23969167

RESUMEN

The myocardial microenvironment plays a decisive role in the survival, migration and differentiation of stem cells. We studied myocardial micro-environmental changes induced by ultrasound-targeted microbubble destruction (UTMD) and their influence on the transplantation of mesenchymal stem cells (MSCs). Various intensities of ultrasound were applied to the anterior chest in canines with myocardial infarction after intravenous injection of microbubbles. The expression of cytokines and adhesion molecules in the infarcted area of the myocardium was detected after three sessions of UTMD in 1 wk. Real-time quantitative reverse transcription polymerase chain reaction (RTQ-PCR) showed that the expression of vascular cell adhesion molecule-1 (VCAM-1), stromal cell-derived factor-1 (SDF-1) and vascular endothelial growth factor (VEGF) in the 1.5 W/cm(2) and 1 W/cm(2) groups was markedly increased compared with the 0.5 W/cm(2) or the control groups (3.8- to 4.7-fold, p < 0.01), and the expression of interleukin-1ß (IL-1ß) in the 1.5 W/cm(2) group was increased twofold over the 1.0 W/cm(2) group, whereas the 0.5 W/cm(2) group experienced no significant changes. UTMD at 1.0 W/cm(2) was performed as previously described before mesenchymal stem cell (MSC) transplantation. Myocardial perfusion, angiogenesis and heart function were investigated before and 1 month after MSC transplantation. Coronary angiography and 99mTc-tetrofosmin scintigraphy revealed that myocardial perfusion was markedly improved after UTMD + MSCs treatment (p < 0.05). At echocardiographic analysis, heart function and the wall motion score index were significantly improved by UTMD + MSCs treatment compared with MSCs or UTMD alone and the control. In a canine model of myocardial infarction, therapeutic effects were markedly enhanced by MSC transplantation after the myocardial micro-environmental changes induced by UTMD; therefore, this novel method may be useful as an efficient approach for cellular therapy.


Asunto(s)
Fluorocarburos/uso terapéutico , Infarto del Miocardio/fisiopatología , Infarto del Miocardio/terapia , Neovascularización Fisiológica/efectos de la radiación , Sonicación/métodos , Nicho de Células Madre/efectos de la radiación , Trasplante de Células Madre , Animales , Terapia Combinada , Perros , Fluorocarburos/efectos de la radiación , Microburbujas/uso terapéutico , Dosis de Radiación , Resultado del Tratamiento
8.
Chin Med J (Engl) ; 126(16): 3064-8, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23981613

RESUMEN

BACKGROUND: Bivalirudin was widely used as an anticoagulant during coronary interventional procedure in western countries. However, it was not available in China before this clinical trial was designed. This randomized, single-blind and multicenter clinical trial aimed to evaluate the efficacy and the safety of domestic bivalirudin during percutaneous coronary intervention (PCI). METHODS: A randomized, single-blind, multicenter trial was designed. Elective PCI candidates in five centers were randomized into a bivalirudin group and a heparin group, which were treated with domestic bivalirudin and non-fractional heparin during the PCI procedure. The efficacy was evaluated by comparing the activated coagulation time (ACT), the procedural success rate (residual stenosis < 20% in target lesions without any coronary artery related adverse events within 24 hours after PCI), and the survival rate without major adverse cardiac events at 30 days after PCI between the two groups. Safety was evaluated by the major/minor bleeding rate. RESULTS: A total of 218 elective PCI patients were randomized into a bivalirudin group (n = 110) and heparin group (n = 108). Except for two patients needing additional dosing in the heparin group, the ACT values of all other patients in both groups were longer than 225 seconds at 5 minutes after the first intravenous bolus. Procedural success rates were respectively 100.0% and 98.2% in the bivalirudin group and heparin group (P > 0.05). Survival rates without major adverse cardiac events at 30 days after PCI were 100.0% in the bivalirudin group and 98.2% in the heparin group (P > 0.05). Mild bleeding rates were 0.9% and 6.9% (P < 0.05) at 24 hours, and 1.9% and 8.8% (P < 0.05) at 30 days after PCI in the bivalirudin group and heparin group respectively. There was one severe gastrointestinal bleeding case in the heparin group. CONCLUSIONS: Domestic bivalirudin is an effective and safe anticoagulant during elective PCI procedures. The efficacy is not inferior to heparin, but the safety is superior to heparin.


Asunto(s)
Antitrombinas/uso terapéutico , Fragmentos de Péptidos/uso terapéutico , Intervención Coronaria Percutánea , Anciano , Antitrombinas/efectos adversos , Femenino , Heparina/uso terapéutico , Hirudinas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Fragmentos de Péptidos/efectos adversos , Proteínas Recombinantes/efectos adversos , Proteínas Recombinantes/uso terapéutico , Método Simple Ciego , Tasa de Supervivencia , Tiempo de Coagulación de la Sangre Total
9.
Zhonghua Xin Xue Guan Bing Za Zhi ; 36(1): 30-5, 2008 Jan.
Artículo en Chino | MEDLINE | ID: mdl-19099923

RESUMEN

OBJECTIVE: To compare the prognostic value of clinical risk score and thrombolysis in myocardial infarction (TIMI) flow grade alone or combined on outcome of acute coronary syndrome (ACS). METHODS: A total of 206 eligible patients [135 males, mean age (67.57 +/- 9.88) years] were enrolled. The primary endpoints included cardiac death and non-cardiac death. The secondary endpoints included non-fatal stroke, reinfarction, heart failure and recurrent angina. Receiver operating characteristic curve (ROC) established by using different endpoints and clinical risk score, TIMI flow grade or combined risk scores. The prognostic value for different endpoint expressed as the area under the curve (AUC). RESULTS: Eleven patients lost during the (11.41 +/- 5.33) months follow up and data were available for 195 patients, 8 patients reached the primary endpoints, and 17 patients reached the secondary end-points at the end of follow up. The AUC was 0.67 (95% CI = 0.557 approximately 0.786), P = 0.006; 0.68 (95% CI = 0.557 approximately 0.786), P = 0.004 and 0.730 (95% CI = 0.691 approximately 0.815), P < 0.001, respectively for clinical risk score, TIMI flow grade and the combined risk score respectively. There were no significant differences among clinical risk score, TIMI flow grade and combined risk score (all P > 0.05) for AUC and for primary end point and the secondary end point. CONCLUSION: The result from this study suggests that the efficacy of predicting the total events based on clinical risk score, TIMI flow grade and combined risk score was similar.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Fibrinolíticos/uso terapéutico , Infarto del Miocardio/tratamiento farmacológico , Anciano , Angina de Pecho/tratamiento farmacológico , Angina Inestable/tratamiento farmacológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Medición de Riesgo , Terapia Trombolítica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...