Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
1.
Heart Rhythm ; 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38752909

RESUMEN

BACKGROUND: Because of differences in chest wall anatomy, female patients may have higher rates of subcutaneous implantable cardioverter-defibrillator (S-ICD) pocket-related complications. OBJECTIVE: We sought to evaluate sex-based outcomes after S-ICD implantation. METHODS: Patients implanted with an S-ICD at Emory Healthcare between 2010 and 2023 were included in the analysis. Patients' clinical characteristics and post-S-ICD implantation complications were collected. RESULTS: There were 429 male patients (68%) and 199 female patients (32%) observed for a median duration of 2.3 years (0.6-4.4 years). Male and female patients had comparable rates of diabetes (28%), end-stage renal disease (29.5%), ejection fraction (30.2% ± 13.4%), and body mass index (29.1 ± 6.6 kg/m2). There was no statistical difference in the incidence of shocks between men and women (26.3% vs 20.1%; P = .09), including appropriate shocks (14.7% vs 12%; P = .98) and inappropriate shocks (11.7% vs 9.5%; P = .98). Pocket-related complications occurred in 21 patients; these included pocket infection (n = 12), wound dehiscence (n = 7), and hematoma requiring drainage (n = 2). Female patients had a significantly higher pocket-related complication rate compared with male patients (7.2% vs 2.5%; P = .016). In controlling for age, body mass index, diabetes, and end-stage renal disease, female patients had higher odds of pocket-related complications compared with male patients (odds ratio, 3.15; 95% confidence interval, 1.27-7.75). Pocket-related complications decreased after 2018 compared with before 2018 (6% vs 2.6%, P = .052), mainly driven by reduction in complications in women (12.3% vs 3.2%; P = .034) but not in men (2.8% vs 2.4%; P = 1). CONCLUSION: In this cohort of S-ICD patients, women had a higher rate of post-S-ICD pocket-related complications that could be explained by sex-based differences in anatomy.

3.
N Engl J Med ; 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38767244

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

5.
Artículo en Inglés | MEDLINE | ID: mdl-38650520

RESUMEN

BACKGROUND: Early guidance recommended a bolus of intravenous heparin at the beginning of leadless pacemaker (LP) implantation procedures. However, due to concern about bleeding complications, more recent practice has tended toward omitting the bolus and only running a continuous heparin infusion through the introducer sheath. The impact of omitting the heparin bolus on procedural outcomes is not clear. METHODS: We reviewed all Medtronic Micra LP implants at our institution from 9/2014 to 9/2022. The decision to bolus with heparin was at operator discretion. RESULTS: Among 621 LP implants, 326 received an intravenous heparin bolus, 243 did not, and 52 patients were excluded because heparin bolus status could not be confirmed. There was a trend toward more frequent omission of the heparin bolus with more recent implants. Median follow-up after LP implant was 14.3 (interquartile range [IQR]: 8.4-27.9) months. There was no difference between heparin bolus and no bolus groups in the number of device deployments/recaptures (1.42 ± 0.81 vs. 1.31 ± 0.66, p = .15). Implant-related adverse events were also similar between heparin bolus and no bolus groups: access-site hematoma requiring intervention (7 vs. 5, p = .99), pseudoaneurysm (1 vs. 1, p = .99), cardiac perforation (1 vs. 1, p = .99), intraprocedural device thrombus formation (2 vs. 4, p = .41), 30-day rehospitalization (21 vs. 15, p = .98), and 30-day all-cause mortality (16 vs. 14, p = .70). There was one additional nonfatal cardiac perforation in a patient who was excluded due to unknown heparin bolus status. Regarding device electrical parameters between heparin bolus and no bolus groups, there were no significant differences at the time of implant: pacing capture threshold 0.5 ± 0.4 vs. 0.5 ± 0.3, p = .10; pacing impedance 739.9 ± 226.4 vs. 719.1 ± 215.4, p = .52; R wave sensing 11.7 ± 5.7 vs. 12.0 ± 5.4, p = .34). Long-term device performance was also similar between groups. CONCLUSION: Omission of the systemic heparin bolus at the time of LP implantation appears safe in appropriately selected patients. Heparin bolus may still be considered in long cases requiring multiple device deployments or in patients at high risk for thrombotic complications.

6.
Heart Rhythm ; 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38574791

RESUMEN

BACKGROUND: One common mode of lead failure is insulation breach, which may result in myopotential noise and device malfunction. "Pseudo-unipolarization" of bipolar pacing stimuli, as observed from a routine 12-lead electrocardiogram (ECG) due to stimulus current leak, has been observed with insulation breaches. OBJECTIVE: We sought to characterize this electrocardiographic finding to detect this type of lead malfunction. METHODS: A total of 138 transvenous leads were analyzed, including 88 with known malfunction and 50 normal leads. The amplitude of a bipolar pacing stimulus on the ECG was recorded and compared with a control data set of newly implanted leads with bipolar stimuli normalized for output. RESULTS: The malfunction group consisted of 61% right atrium and 39% right ventricle leads with mean pacing output of 2.74 V at 0.5 ms. There was a significant difference in ECG bipolar stimulus amplitudes at time of identification of failure (7.89 ± 7.56 mm/V; P < .001) compared with those of normal leads (0.86 ± 0.41 mm/V). Receiver operating characteristic curve for the prediction of lead malfunction based on absolute ECG amplitude displayed an area under the curve of 0.93 (95% CI, 0.891-0.969). When normalized for programmed stimulus output, a cutoff of 5 mm/V demonstrated a sensitivity of 91% and a specificity of 92% (area under the curve, 0.967; 95% CI, 0.938-0.996). CONCLUSION: The maximum amplitude of a bipolar pacing stimulus on the ECG is significantly lower in normal functioning leads compared with those with known malfunction. This simply derived variable demonstrated good accuracy at identifying lead failure due to insulation breach.

8.
J Cardiovasc Electrophysiol ; 35(5): 929-938, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38450808

RESUMEN

INTRODUCTION: Transvenous leads have been implicated in tricuspid valve (TV) dysfunction, but limited data are available regarding the effect of extracting leads across the TV on valve regurgitation. The aim of this study is to quantify tricuspid regurgitation (TR) before and after lead extraction and identify predictors of worsening TR. METHODS: We studied 321 patients who had echocardiographic data before and after lead extraction. TR was graded on a scale (0 = none/trivial, 1 = mild, 2 = moderate, 3 = severe). A change of >1 grade following extraction was considered significant. RESULTS: A total of 321 patients underwent extraction of a total of 338 leads across the TV (1.05 ± 0.31 leads across the TV per patient). There was no significant difference on average TR grade pre- and postextraction (1.18 ± 0.91 vs. 1.15 ± 0.87; p = 0.79). TR severity increased after extraction in 84 patients, but was classified as significantly worse (i.e., >1 grade change in severity) in only 8 patients (2.5%). Use of laser lead extraction was associated with a higher rate of worsening TR postextraction (44.0% vs. 31.6%, p = 0.04). CONCLUSION: In our single-center analysis, extraction of leads across the TV did not significantly affect the extent of TR in most patients. Laser lead extraction was associated with a higher rate of worsening TR after extraction.


Asunto(s)
Remoción de Dispositivos , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/diagnóstico , Masculino , Femenino , Remoción de Dispositivos/efectos adversos , Anciano , Resultado del Tratamiento , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Desfibriladores Implantables , Factores de Tiempo , Marcapaso Artificial , Anciano de 80 o más Años , Dispositivos de Terapia de Resincronización Cardíaca
9.
Circ Arrhythm Electrophysiol ; 17(3): e012363, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38344811

RESUMEN

BACKGROUND: A growing number of patients with tetralogy of Fallot develop left ventricular systolic dysfunction and heart failure, in addition to right ventricular dysfunction. Although cardiac resynchronization therapy (CRT) is an established treatment option, the effect of CRT in this population is still not well defined. This study aimed to investigate the early and late efficacy, survival, and safety of CRT in patients with tetralogy of Fallot. METHODS: Data were analyzed from an observational, retrospective, multicenter cohort, initiated jointly by the Pediatric and Congenital Electrophysiology Society and the International Society of Adult Congenital Heart Disease. Twelve centers contributed baseline and longitudinal data, including vital status, left ventricular ejection fraction (LVEF), QRS duration, and NYHA functional class. Outcomes were analyzed at early (3 months), intermediate (1 year), and late follow-up (≥2 years) after CRT implantation. RESULTS: A total of 44 patients (40.3±19.2 years) with tetralogy of Fallot and CRT were enrolled. Twenty-nine (65.9%) patients had right ventricular pacing before CRT upgrade. The left ventricular ejection fraction improved from 32% [24%-44%] at baseline to 42% [32%-50%] at early follow-up (P<0.001) and remained improved from baseline thereafter (P≤0.002). The QRS duration decreased from 180 [160-205] ms at baseline to 152 [133-182] ms at early follow-up (P<0.001) and remained decreased at intermediate and late follow-up (P≤0.001). Patients with upgraded CRT had consistent improvement in left ventricular ejection fraction and QRS duration at each time point (P≤0.004). Patients had a significantly improved New York Heart Association functional class after CRT implantation at each time point compared with baseline (P≤0.002). The transplant-free survival rates at 3, 5, and 8 years after CRT implantation were 85%, 79%, and 73%. CONCLUSIONS: In patients with tetralogy of Fallot treated with CRT consistent improvement in QRS duration, left ventricular ejection fraction, New York Heart Association functional class, and reasonable long-term survival were observed. The findings from this multicenter study support the consideration of CRT in this unique population.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiopatías Congénitas , Insuficiencia Cardíaca , Tetralogía de Fallot , Adulto , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Cardiopatías Congénitas/terapia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Estudios Retrospectivos , Volumen Sistólico , Tetralogía de Fallot/cirugía , Resultado del Tratamiento , Función Ventricular Izquierda , Persona de Mediana Edad
10.
Artículo en Inglés | MEDLINE | ID: mdl-38413483

RESUMEN

BACKGROUND: Following catheter ablation, vascular access management involves potential complications and prolonged recovery. Recently, suture-mediated closure (SMC) devices were approved for venous access procedures. The objective of this study is to evaluate the safety of a commercially available SMC for multiple access site venous closure by duplex ultrasound (DUS) in asymptomatic subjects with non-visible complications. METHODS: Thirty-six subjects (63 ± 10.7 years old, 12 female) were enrolled. Following catheter ablation for atrial fibrillation, all subjects had SMC of every venous access site. Subjects underwent DUS of femoral veins and arteries. DUS was performed at discharge, and again at 30 days. Subjects were evaluated for clinically apparent vascular complications. RESULTS: Mean procedure duration was 138.6 min, and the time to hemostasis was 3.1 min/access site and 9.5 min/subject. Median time to ambulation was 193.5 min, and median time to discharge was 5.95 h, with discharge as early as 2.4 h. A median of 2 sheaths/vein and a median of 2 SMC devices/vein were used. There were no major complications and a 16.7% (6/36) minor complication rate at discharge. All complications resolved at 30 days. The complication rate was not higher in patients with 2 SMC per access site as compared to the patients who just received 1 SMC per access site. CONCLUSIONS: This study demonstrates the safety of multi-access closure using SMC, following catheter ablation procedures, for closure of sites that use sheath sizes from ≤ 8F to ≥ 15F and for those that use 2 or more SMCs per access site.

12.
J Cardiovasc Electrophysiol ; 35(1): 206-213, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38018417

RESUMEN

Left ventricular assist device (LVAD) implantation is an established treatment for patients with advanced heart failure refractory to medical therapy. However, the incidence of ventricular arrhythmias (VAs) is high in this population, both in the acute and delayed phases after implantation. About one-third of patients implanted with an LVAD will experience sustained VAs, predisposing these patients to worse outcomes and complicating patient management. The combination of pre-existing myocardial substrate and complex electrical remodeling after LVAD implantation account for the high incidence of VAs observed in this population. LVAD patients presenting VAs refractory to antiarrhythmic therapy and catheter ablation procedures are not rare. In such patients, treatment options are extremely limited. Stereotactic body radiation therapy (SBRT) is a technique that delivers precise and high doses of radiation to highly defined targets, reducing exposure to adjacent normal tissue. Cardiac SBRT has recently emerged as a promising alternative with a growing number of case series reporting the effectiveness of the technique in reducing the VA burden in patients with arrhythmias refractory to conventional therapies. The safety profile of cardiac SBRT also appears favorable, even though the current clinical experience remains limited. The use of cardiac SBRT for the treatment of refractory VAs in patients implanted with an LVAD are even more scarce. This review summarizes the clinical experience of cardiac SBRT in LVAD patients and describes technical considerations related to the implementation of the SBRT procedure in the presence of an LVAD.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Radiocirugia , Taquicardia Ventricular , Humanos , Radiocirugia/efectos adversos , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Arritmias Cardíacas/cirugía , Insuficiencia Cardíaca/terapia , Resultado del Tratamiento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirugía
14.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38000900

RESUMEN

AIMS: Single-connector (DF4) defibrillator leads have become the predominantly implanted transvenous implantable cardioverter-defibrillator lead. However, data on their long-term performance are derived predominantly from manufacturer product performance reports. METHODS AND RESULTS: We reviewed medical records in 5289 patients with DF4 leads between 2011 and 2023 to determine the frequency of lead-related abnormalities. We defined malfunction as any single or combination of electrical abnormalities requiring revision including a sudden increase (≥2×) in stimulation threshold, a discrete jump in high-voltage impedance, or sensing of non-physiologic intervals or noise. We documented time to failure, predictors of failure, and management strategies. Mean follow-up after implant was 4.15 ± 3.6 years (median = 3.63), with 37% of leads followed for >5 years. A total of 80 (1.5%) leads demonstrated electrical abnormalities requiring revision with an average time to failure of 4 ± 2.8 years (median = 3.5). Of the leads that malfunctioned, 62/80 (78%) were extracted and replaced with a new lead and in the other 18 cases, malfunctioned DF4 leads were abandoned, and a new lead implanted. In multivariable models, younger age at implant (OR 1.03 per year; P < 0.001) and the presence of Abbott/St. Jude leads increased the risk of malfunction. CONCLUSION: DF4 defibrillator leads demonstrate excellent longevity with >98.3% of leads followed for at least 5 years still functioning normally. Younger age at implant and lead manufacturer are associated with an increased risk of DF4 lead malfunction. The differences in lead survival between manufacturers require further investigation.


Asunto(s)
Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Falla de Equipo , Estudios Retrospectivos
15.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38006390

RESUMEN

AIMS: The mechanisms of transition from regular rhythms to ventricular fibrillation (VF) are poorly understood. The concordant to discordant repolarization alternans pathway is extensively studied; however, despite its theoretical centrality, cannot guide ablation. We hypothesize that complex repolarization dynamics, i.e. oscillations in the repolarization phase of action potentials with periods over two of classic alternans, is a marker of electrically unstable substrate, and ablation of these areas has a stabilizing effect and may reduce the risk of VF. To prove the existence of higher-order periodicities in human hearts. METHODS AND RESULTS: We performed optical mapping of explanted human hearts obtained from recipients of heart transplantation at the time of surgery. Signals recorded from the right ventricle endocardial surface were processed to detect global and local repolarization dynamics during rapid pacing. A statistically significant global 1:4 peak was seen in three of six hearts. Local (pixel-wise) analysis revealed the spatially heterogeneous distribution of Periods 4, 6, and 8, with the regional presence of periods greater than two in all the hearts. There was no significant correlation between the underlying restitution properties and the period of each pixel. CONCLUSION: We present evidence of complex higher-order periodicities and the co-existence of such regions with stable non-chaotic areas in ex vivo human hearts. We infer that the oscillation of the calcium cycling machinery is the primary mechanism of higher-order dynamics. These higher-order regions may act as niduses of instability and may provide targets for substrate-based ablation of VF.


Asunto(s)
Ventrículos Cardíacos , Corazón , Humanos , Arritmias Cardíacas , Fibrilación Ventricular/cirugía , Potenciales de Acción/fisiología
16.
Heart Rhythm O2 ; 4(10): 618-624, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37936674

RESUMEN

Background: Algorithms to automatically adjust atrioventricular (AV) and interventricular (VV) intervals in cardiac resynchronization therapy (CRT) devices are common, but their clinical efficacy is unknown. Objective: The purpose of this study was to evaluate automatic CRT algorithms in patients with heart failure for the reduction of mortality, heart failure hospitalizations, and clinical improvement. Methods: We performed a systematic review and meta-analysis of randomized controlled trials (RCTs) in patients with CRT using automatic algorithms that change AV and VV intervals dynamically without manual input, on a beat-to-beat basis. We performed a subgroup analysis including intracardiac electrogram-based (EGM) algorithms and contractility-based algorithms. Results: Nine RCTs with 8531 participants were included, of whom 4275 (50.1%) were randomized to automatic algorithm. Seven of the 9 trials used EGM-based algorithms, and 2 used contractility sensors. There was no difference in all-cause mortality (10.3% vs 11.3%; odds ratio [OR] 0.90; 95% confidence interval [CI] 0.71-1.03; P = .13; I2 = 0%) or heart failure hospitalizations (15.0% vs 16.1%; OR 0.924; 95% CI 0.81-1.04; P = .194; I2 = 0%) between the automatic algorithm group and the control group. Study-defined clinical improvement was also not significantly different between groups (66.6% vs 63.3%; risk ratio 1.01; 95% CI 0.95-1.06; P = .82; I2 = 50%). In the contractility-based subgroup, there was a trend toward greater clinical improvement with the use of the automatic algorithm (75% vs 68.3%; OR 1.45; 95% CI 0.97-2.18; P = .07; I2 = 40%), which did not reach statistical significance. The overall risk of bias was low. Conclusion: Automatic algorithms that change AV or VV intervals did not improve mortality, heart failure hospitalizations, or cardiovascular symptoms in patients with heart failure and CRT.

17.
Front Cardiovasc Med ; 10: 1267800, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37799779

RESUMEN

Background: Stereotactic arrhythmia radioablation (STAR) is a potential new therapy for patients with refractory ventricular tachycardia (VT). The arrhythmogenic substrate (target) is synthesized from clinical and electro-anatomical information. This study was designed to evaluate the baseline interobserver variability in target delineation for STAR. Methods: Delineation software designed for research purposes was used. The study was split into three phases. Firstly, electrophysiologists delineated a well-defined structure in three patients (spinal canal). Secondly, observers delineated the VT-target in three patients based on case descriptions. To evaluate baseline performance, a basic workflow approach was used, no advanced techniques were allowed. Thirdly, observers delineated three predefined segments from the 17-segment model. Interobserver variability was evaluated by assessing volumes, variation in distance to the median volume expressed by the root-mean-square of the standard deviation (RMS-SD) over the target volume, and the Dice-coefficient. Results: Ten electrophysiologists completed the study. For the first phase interobserver variability was low as indicated by low variation in distance to the median volume (RMS-SD range: 0.02-0.02 cm) and high Dice-coefficients (mean: 0.97 ± 0.01). In the second phase distance to the median volume was large (RMS-SD range: 0.52-1.02 cm) and the Dice-coefficients low (mean: 0.40 ± 0.15). In the third phase, similar results were observed (RMS-SD range: 0.51-1.55 cm, Dice-coefficient mean: 0.31 ± 0.21). Conclusions: Interobserver variability is high for manual delineation of the VT-target and ventricular segments. This evaluation of the baseline observer variation shows that there is a need for methods and tools to improve variability and allows for future comparison of interventions aiming to reduce observer variation, for STAR but possibly also for catheter ablation.

18.
medRxiv ; 2023 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-37662394

RESUMEN

Background: Repolarization alternans, defined as period-2 oscillation in the repolarization phase of the action potentials, provides a mechanistic link between cellular dynamics and ventricular fibrillation (VF). Theoretically, higher-order periodicities (e.g., periods 4, 6, 8,...) are expected but have minimal experimental evidence. Methods: We studied explanted human hearts obtained from recipients of heart transplantation at the time of surgery. Optical mapping of the transmembrane potential was performed after staining the hearts with voltage-sensitive fluorescent dyes. Hearts were stimulated at an increasing rate until VF was induced. Signals recorded from the right ventricle endocardial surface prior to induction of VF and in the presence of 1:1 conduction were processed using the Principal Component Analysis and a combinatorial algorithm to detect and quantify higher-order dynamics. Results were correlated to the underlying electrophysiological characteristics as quantified by restitution curves and conduction velocity. Results: A prominent and statistically significant global 1:4 peak (corresponding to period-4 dynamics) was seen in three of the six studied hearts. Local (pixel-wise) analysis revealed the spatially heterogeneous distribution of periods 4, 6, and 8, with the regional presence of periods greater than two in all the hearts. There was no significant correlation between the underlying restitution properties and the period of each pixel. Discussion: We present evidence of higher-order periodicities and the co-existence of such regions with stable non-chaotic areas in ex-vivo human hearts. We infer from the independence of the period to the underlying restitution properties that the oscillation of the excitation-contraction coupling and calcium cycling mechanisms is the primary mechanism of higher-order dynamics. These higher-order regions may act as niduses of instability that can degenerate into chaotic fibrillation and may provide targets for substrate-based ablation of VF.

20.
J Cardiovasc Electrophysiol ; 34(11): 2216-2222, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37727925

RESUMEN

INTRODUCTION: Permanent pacing indications are common after cardiac surgery and transcatheter structural valve interventions. Leadless pacemakers (LPs) have emerged as a useful alternative to transvenous pacemakers. However, current commercially available LPs are unable to provide atrial pacing or cardiac resynchronization and relatively little is known about LP outcomes after cardiac surgery and transcatheter valve interventions. METHODS: This retrospective study included patients who received a Micra VR (MicraTM MC1VR01) or Micra AV (MicraTM MC1AVR1) (Medtronic) leadless pacemaker following cardiac surgery or transcatheter structural valve intervention between September 2014 and September 2022. Device performance and clinical outcomes, including ventricular pacing burden, ejection fraction, and need for conversion to transvenous pacing systems, were evaluated during follow-up. RESULTS: A total of 78 patients were included, of whom 40 received a Micra VR LP implant, and 38 received a Micra AV LP implant. The mean age of the cohort was 65.9 ± 17.9 years, and 48.1% were females. The follow-up duration for the entire cohort was 1.3 ± 1.1 years: 1.6 ± 1.3 years for the Micra VR group and 0.8 ± 0.5 years for the Micra AV group. Among the cohort, 50 patients had undergone cardiac surgery and 28 underwent transcatheter structural valve interventions. Device electrical performance was excellent during follow-up, with a small but clinically insignificant increase in ventricular pacing threshold and a slight decrease in pacing impedance. The mean right ventricle pacing (RVP) burden significantly decreased over time in the entire cohort (74.3% ± 37.2% postprocedure vs. 47.7% ± 40.6% at last follow-up, p < .001), and left ventricle ejection fraction (LVEF) showed a modest but significant downward trend during follow-up (55.0% ± 10.6% vs. 51.5% ± 11.2% p < .001). Patients with Micra VR implants had significantly reduced LVEF during follow-up (54.1% ± 11.9% vs. 48.8% ± 11.9%, p = .003), whereas LVEF appeared stable in the Micra AV group during follow-up (56.1% ± 9.0% vs. 54.6% ± 9.7%, p = .06). Six patients (7.7%) required conversion to transvenous pacing systems, four who required cardiac resynchronization for drop in LVEF with high RVP burden and two who required dual-chamber pacemakers for symptomatic sinus node dysfunction. CONCLUSION: Leadless pacemakers provide a useful alternative to transvenous pacemakers in appropriately selected patients after cardiac surgery and transcatheter structural valve interventions. Device performance is excellent over medium-term follow-up. However, a significant minority of patients require conversion to transvenous pacing systems for cardiac resynchronization or atrial pacing support, demonstrating the need for close electrophysiologic follow-up in this cohort.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Marcapaso Artificial , Femenino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Estudios Retrospectivos , Lipopolisacáridos , Resultado del Tratamiento , Diseño de Equipo , Estimulación Cardíaca Artificial/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...