Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
bioRxiv ; 2024 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-38645028

RESUMEN

Skeletal muscle architecture is a key determinant of muscle function. Architectural properties such as fascicle length, pennation angle, and curvature can be characterized using Diffusion Tensor Imaging (DTI), but acquiring these data during a contraction is not currently feasible. However, an image registration-based strategy may be able to convert muscle architectural properties observed at rest to their contracted state. As an initial step toward this long-term objective, the aim of this study was to determine if an image registration strategy could be used to convert the whole-muscle average architectural properties observed in the extended joint position to those of a flexed position, following passive rotation. DTI and high-resolution fat/water scans were acquired in the lower leg of seven healthy participants on a 3T MR system in +20° (plantarflexion) and -10° (dorsiflexion) foot positions. The diffusion and anatomical images from the two positions were used to propagate DTI fiber-tracts from seed points along a mesh representation of the aponeurosis of fiber insertion. The -10° and +20° anatomical images were registered and the displacement fields were used to transform the mesh and fiber-tracts from the +20° to the -10° position. Student's paired t-tests were used to compare the mean architectural parameters between the original and transformed fiber-tracts. The whole-muscle average fiber-tract length, pennation angle, curvature, and physiological cross-sectional areas estimates did not differ significantly. DTI fiber-tracts in plantarflexion can be transformed to dorsiflexion position without significantly affecting the average architectural characteristics of the fiber-tracts. In the future, a similar approach could be used to evaluate muscle architecture in a contracted state.

2.
Skeletal Radiol ; 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38653786

RESUMEN

OBJECTIVE: To prospectively evaluate a deep learning-based denoising reconstruction (DLR) for improved resolution and image quality in musculoskeletal (MSK) magnetic resonance imaging (MRI). METHODS: Images from 137 contrast-weighted sequences in 40 MSK patients were evaluated. Each sequence was performed twice, first with the routine parameters and reconstructed with a routine reconstruction filter (REF), then with higher resolution and reconstructed with DLR, and with three conventional reconstruction filters (NL2, GA43, GA53). The five reconstructions (REF, DLR, NL2, GA43, and GA53) were de-identified, randomized, and blindly reviewed by three MSK radiologists using eight scoring criteria and a forced ranking. Quantitative SNR, CNR, and structure's full width at half maximum (FWHM) for resolution assessment were measured and compared. To account for repeated measures, Generalized Estimating Equations (GEE) with Bonferroni adjustment was used to compare the reader's scores, SNR, CNR, and FWHM between DLR vs. NL2, GA43, GA53, and REF. RESULTS: Compared to the routine REF images, the resolution was improved by 47.61% with DLR from 0.39 ± 0.15 mm2 to 0.20 ± 0.06 mm2 (p < 0.001). Per-sequence average scan time was shortened by 7.93% with DLR from 165.58 ± 21.86 s to 152.45 ± 25.65 s (p < 0.001). Based on the average scores, DLR images were rated significantly higher in all image quality criteria and the forced ranking (p < 0.001). CONCLUSION: This prospective clinical evaluation demonstrated that DLR allows approximately two times finer resolution and improved image quality compared to the standard-of-care images.

3.
Magn Reson Med ; 91(4): 1337-1353, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38044800

RESUMEN

PURPOSE: To quantify the effects of the intrinsic signal pattern, image acquisition conditions, and data analysis conditions on diffusion-tensor MRI (DTMRI) tractography-based muscle architecture estimates using a sampling-reconstruction assessment framework. METHODS: Numerical models of muscles were constructed with realistic architectural properties. DTMRI signals were computed at signal-to-noise ratio (SNR) of 24-96 and common voxel sizes. Fiber tracking was performed, and the results were compared with the known architectural properties. RESULTS: SNR exerted the most significant impact on the outcome. The outcome variables approached asymptotes at SNR ≈ 54. Large in-plane voxel dimensions reduced the similarity between reconstructed fibers and the known architectural properties. Higher order polynomials helped reconstruct fibers with more complicated geometry but overfit noise for less complex geometries. The intrinsic fiber curvature also affected the robustness of polynomial smoothing to SNR. Other conditions, such as the fiber dimensionality, voxel aspect ratio, and slice thickness, did not affect the outcomes. CONCLUSION: SNR ≥ 54 is recommended for accurate muscle architecture characterization using DTMRI. Averaged across all simulated conditions, the greatest percent errors under SNR = 54 were -5.6% and -4.0% for the pennation angle and fiber-tract length estimates, respectively. For fiber tracts with intermediate intrinsic curvature, the greatest percent error for the curvature estimate was 9.8% for SNR = 54. Smaller in-plane voxel size (≤1.5 mm) is preferred to minimize the estimation error in architectural properties. If necessary, slice thickness may be adjusted within typical ranges to achieve sufficient SNR when slices are aligned near the fiber direction. Third-order polynomial fitting is appropriate for smoothing fiber tracts.


Asunto(s)
Imagen de Difusión Tensora , Fibras Musculares Esqueléticas , Imagen de Difusión Tensora/métodos , Relación Señal-Ruido , Algoritmos
4.
J Orthop Res ; 41(8): 1643-1652, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37163368

RESUMEN

Social media usage, particularly Twitter, among scientists in academia has increased in recent years. However, Twitter's use in scholarly post-publication dissemination of orthopaedic research and musculoskeletal advocacy remains low. To enhance usage of Twitter among musculoskeletal researchers, this article reviews data supporting the professional benefits of using the platform to disseminate scholarly works. Next, we provide a linear workflow for Tweet curation, discuss the importance of data-driven decision making behind tweet curation and posting, and propose new guidelines for professional Twitter usage. Since this workflow may not eliminate all the identified barriers and new institutionalized shifts in policies regarding curation and consumption of social media on Twitter, we also briefly introduce and explore using other social media platforms. We hope this information will be persuasive and compelling to those in the orthopedic research field and be broadly applicable to others in related scientific fields who wish to disseminate findings and engage a public audience on social media. In addition, we encourage the Orthopedic Research Society (ORS) and Journal of Orthopedic Research (JOR) communities to take advantage of the many tools curated by the Wiley editorial office and the ORS social media committee to increase dissemination of their scholarly works online. Twitter and social media can assist in accomplishing our mission of creating a world without musculoskeletal limitations via the timely dissemination of orthopedic information. However, this can only be accomplished if the orthopedic research community has a unified and strong online presence actively engaged in orthopaedic research findings and news.


Asunto(s)
Medios de Comunicación Sociales , Humanos , Investigadores
5.
Magn Reson Imaging ; 82: 42-54, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34147595

RESUMEN

BACKGROUND: Magnetic resonance (MR) T2 and T2* mapping sequences allow in vivo quantification of biochemical characteristics within joint cartilage of relevance to clinical assessment of conditions such as hip osteoarthritis (OA). PURPOSE: To evaluate an automated immediate reliability analysis of T2 and T2* mapping from MR examinations of hip joint cartilage using a bone and cartilage segmentation pipeline based around focused shape modelling. STUDY TYPE: Technical validation. SUBJECTS: 17 asymptomatic volunteers (M: F 7:10, aged 22-47 years, mass 50-90 kg, height 163-189 cm) underwent unilateral hip joint MR examinations. Automated analysis of cartilage T2 and T2* data immediate reliability was evaluated in 9 subjects (M: F 4: 5) for each sequence. FIELD STRENGTH/SEQUENCE: A 3 T MR system with a body matrix flex-coil was used to acquire images with the following sequences: T2 weighted 3D-trueFast Imaging with Steady-State Precession (water excitation; 10.18 ms repetition time (TR); 4.3 ms echo time (TE); Voxel Size (VS): 0.625 × 0.625 × 0.65 mm; 160 mm field of view (FOV); Flip Angle (FA): 30 degrees; Pixel Bandwidth (PB): 140 Hz/pixel); a multi-echo spin echo (MESE) T2 mapping sequence (TR/TE: 2080/18-90 ms (5 echoes); VS: 4 × 0.78 × 0.78 mm; FOV: 200 mm; FA: 180 degrees; PB: 230 Hz/pixel) and a MESE T2* mapping sequence (TR/TE: 873/3.82-19.1 ms (5 echoes); VS: 3 × 0.625 × 0.625 mm; FOV: 160 mm; FA: 25 degrees; PB: 250 Hz/pixel). ASSESSMENT: Automated cartilage segmentation and quantitative analysis provided T2 and T2* data from test-retest MR examinations to assess immediate reliability. STATISTICAL TESTS: Coefficient of variation (CV) and intraclass correlations (ICC2, 1) to analyse automated T2 and T2* mapping reliability focusing on the clinically important superior cartilage regions of the hip joint. RESULTS: Comparisons between test-retest T2 and (T2*) data revealed mean CV's of 3.385% (1.25%), mean ICC2, 1's of 0.871 (0.984) and median mean differences of -1.139ms (+0.195ms). CONCLUSION: The T2 and T2* times from automated analyses of hip cartilage from test-retest MR examinations had high (T2) and excellent (T2*) immediate reliability.


Asunto(s)
Cartílago Articular , Imagen por Resonancia Magnética , Cartílago Articular/diagnóstico por imagen , Articulación de la Cadera/diagnóstico por imagen , Humanos , Espectroscopía de Resonancia Magnética , Reproducibilidad de los Resultados
6.
Eur J Radiol Open ; 8: 100329, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33644264

RESUMEN

PURPOSE: To examine the relationship between glenohumeral cartilage T2 mapping values and rotator cuff pathology. METHOD: Fifty-nine subjects (age 48.2 ±â€¯13.5 years, 15 asymptomatic volunteers and 10 tendinosis, 13 partial-thickness tear, 8 full-thickness tear, and 13 massive tear patients) underwent glenohumeral cartilage T2 mapping. The humeral head cartilage was segmented in the sagittal and coronal planes. The glenoid cartilage was segmented in the coronal plane. Group means for each region were calculated and compared between the groups. RESULTS: Massive tear group T2 values were significantly higher than the asymptomatic group values for the humeral head cartilage included in the sagittal (45 ±â€¯7 versus 32 ±â€¯4 ms, p <  .001) and coronal (44 ± 6 versus 38 ± 1 ms, p =  0.01) plane images. Mean T2 was also significantly higher for massive than full-thickness tears (45 ± 7 versus 38 ± 5 ms, p =  0.02), massive than partial-thickness tears (45 ± 7 versus 34 ± 4 ms, p <  0.001), and massive tears than tendinosis (45 ± 7 versus 35 ± 4 ms, p =  0.001) in the sagittal-images humeral head region and significantly higher for massive tears than asymptomatic shoulders (44 ± 6 versus 38 ± 1 ms, p =  0.01) in the coronal-images humeral head region. CONCLUSION: Humeral head cartilage T2 values were significantly positively correlated with rotator cuff pathology severity. Massive rotator cuff tear patients demonstrated significantly higher superior humeral head cartilage T2 mapping values relative to subjects with no/lesser degrees of rotator cuff pathology.

7.
Cartilage ; 13(1_suppl): 674S-684S, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33269605

RESUMEN

OBJECTIVE: The purpose of this work was to compare measurements of talar cartilage thickness and cartilage and bone surface geometry from clinically feasible magnetic resonance imaging (MRI) against high-accuracy laser scan models. Measurement of talar bone and cartilage geometry from MRI would provide useful information for evaluating cartilage changes, selecting osteochondral graft sources or creating patient-specific joint models. DESIGN: Three-dimensional (3D) bone and cartilage models of 7 cadaver tali were created using (1) manual segmentation of high-resolution volumetric sequence 3T MR images and (2) laser scans. Talar cartilage thickness was compared between the laser scan- and MRI-based models for the dorsal, medial, and lateral surfaces. The laser scan- and MRI-based cartilage and bone surface models were compared using model-to-model distance. RESULTS: Average cartilage thickness within the dorsal, medial, and lateral surfaces were 0.89 to 1.05 mm measured with laser scanning, and 1.10 to 1.22 mm measured with MRI. MRI-based thickness was 0.16 to 0.32 mm higher on average in each region. The average absolute surface-to-surface differences between laser scan- and MRI-based bone and cartilage models ranged from 0.16 to 0.22 mm for bone (MRI bone models smaller than laser scan models) and 0.35 to 0.38 mm for cartilage (MRI bone models larger than laser scan models). CONCLUSIONS: This study demonstrated that cartilage and bone 3D modeling and measurement of average cartilage thickness on the dorsal, medial, and lateral talar surfaces using MRI were feasible and provided similar model geometry and thickness values to ground-truth laser scan-based measurements.


Asunto(s)
Cartílago Articular , Astrágalo , Cadáver , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/patología , Humanos , Rayos Láser , Imagen por Resonancia Magnética/métodos , Astrágalo/diagnóstico por imagen
8.
J Exp Orthop ; 6(1): 22, 2019 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-31139976

RESUMEN

BACKGROUND: The diagnosis of incomplete acute and chronic posterior cruciate ligament (PCL) tears can be challenging with conventional magnetic resonance (MR) imaging, particularly for injuries in which the ligament appears continuous as occurs with chronic PCL tears that have scarred in continuity. Quantitative mapping from MR imaging may provide additional useful diagnostic information in these cases. The purpose of this study was to assess the feasibility of quantifying transverse relaxation time (T2) mapping values at 3 Tesla (T) in a prospectively enrolled patient cohort with chronic PCL tears. METHODS: Twelve subjects with acute or chronic functionally torn PCL, confirmed on clinical exam and posterior knee stress radiographs (with 8 mm or more of increased posterior tibial translation), were enrolled prospectively over a span of 4 years (age: 28-52 years, injury occurred 2 weeks to 15 years prior). Unilateral knee MR images were acquired at 3 T, including a multi-echo spin-echo T2 mapping scan in the sagittal plane. For the six subjects with a continuous PCL on MR imaging the PCL was manually segmented and divided into proximal, mid and distal thirds. Summary statistics for T2 values in each third of the ligament were compiled. RESULTS: Across the six patient subjects with a continuous ligament, the mean T2 for the entire PCL was 36 ± 9 ms, with the highest T2 values found in the proximal third (proximal: 41 ms, mid 30 ms, distal 37 ms). The T2 values for the entire PCL and for the proximal third subregion were higher than those recently published for asymptomatic volunteers (entire posterior cruciate ligament: 31 ± 5 ms, proximal: 30 ms, mid: 29 ms, distal: 37 ms) with similar methodology. CONCLUSION: Mean T2 values were quantified for acute and chronic PCL tears in this prospectively enrolled patient cohort and were higher than those reported for asymptomatic volunteers. This novel approach of using quantitative mapping to highlight injured areas of the posterior cruciate ligament has potential to provide additional diagnostic information in the challenging case of a suspected posterior cruciate ligament tear which appears continuous, including chronic tears that have scarred in continuity and may appear intact on conventional magnetic resonance imaging.

9.
Eur J Radiol ; 113: 209-216, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30927949

RESUMEN

OBJECTIVE: To develop a method for T2 mapping of the entire tibiotalar/hindfoot articular surfaces and to examine regional T2 variation in asymptomatic volunteers, establishing necessary methods for future T2 mapping work in patients with ankle/hindfoot injury. MATERIALS AND METHODS: Twenty-six asymptomatic volunteers (11 female/13 male, aged 23-64 years in final analysis) underwent sagittal T2 mapping. Tibiotalar and hindfoot cartilage surfaces were segmented by two raters. The tibiotalar joint cartilage was divided into subregions to assess T2 variation across the joint. The articular surface and subregion mean T2 values were compared using Tukey post hoc pairwise comparisons to test for statistical significance. RESULTS AND CONCLUSION: Mean ankle/hindfoot cartilage T2 ranged from 37 ± 3 to 47 ± 7 ms. Tibial plafond mean T2 was significantly different from the middle and posterior subtalar cartilage T2 (both articular surface comparisons resulted in P < .05). Talar dome mean T2 was significantly different from the posterior calcaneal-side and talar-side subtalar cartilage, and middle calcaneal-side subtalar cartilage (P < .05 for all comparisons). Tibial plafond middle versus lateral, anterior versus middle, middle versus posterior, and anterior versus posterior subregion T2 values were significantly different (P < .05 for all comparisons). Talar dome medial versus middle, middle versus lateral, anterior versus middle, and middle versus posterior subregion T2 values were significantly different (P < .05 for all comparisons). Ankle/hindfoot joint cartilage T2 mapping and segmentation was found to be feasible for all cartilage surfaces except the anterior subtalar joint facet. Mean T2 differed significantly between ankle/hindfoot joint and subregion cartilage in asymptomatic volunteers.


Asunto(s)
Articulación del Tobillo/anatomía & histología , Cartílago Articular/anatomía & histología , Adulto , Enfermedades Asintomáticas , Estudios de Factibilidad , Femenino , Voluntarios Sanos , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Adulto Joven
10.
Knee Surg Sports Traumatol Arthrosc ; 27(9): 2863-2876, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31020353

RESUMEN

PURPOSE: The purpose of this study was to compare the reliability and accuracy of existing computed tomography (CT) methods for measuring the distal tibiofibular syndesmosis in uninjured, paired cadaveric specimens and in simulated malreduction models. It was hypothesized that a repeatable set of measurements exists to accurately and quantitatively describe the typical forms of syndesmotic malreduction using contralateral ankle comparison. METHODS: Twelve cadaveric lower-leg specimen pairs were imaged with CT to generate models for this study. Thirty-five measurements were performed on each native model. Next, four distinct fibular malreductions were produced via digital simulation and all measurements were repeated for each state: (1) 2-mm lateral translation; (2) 2-mm posterior translation; (3) 7-degree external rotation; (4) the previous three states combined. The modified standardized response mean (mSRM) was calculated for each measurement. To assess rater reliability and side-to-side agreements of the native state measurements, intraclass correlation coefficients (ICC) and Pearson correlation coefficients (PCC) were calculated, respectively. RESULTS: The most responsive measurements for detecting isolated malreduction were the Leporjärvi clear space for lateral translation, the Nault anterior tibiofibular distance for posterior translation, and the Nault talar dome angle for external rotation of the fibula. These measurements demonstrated fair to excellent inter-rater ICCs (0.64-0.76) and variable side-to-side PCCs (0.14-0.47). CONCLUSIONS: The most reliable method to assess the syndesmosis on CT was to compare side-to-side differences using three distinct measurements, one for each type of fibular malreduction, allowing assessment of the magnitude and directionality of syndesmosis malreduction. Reliable evaluation is essential for assessing subtle syndesmosis injuries, malreduction and surgical planning.


Asunto(s)
Fracturas de Tobillo/diagnóstico por imagen , Traumatismos del Tobillo/diagnóstico por imagen , Articulación del Tobillo/diagnóstico por imagen , Tobillo/diagnóstico por imagen , Adulto , Anciano , Fracturas de Tobillo/cirugía , Traumatismos del Tobillo/cirugía , Articulación del Tobillo/cirugía , Cadáver , Peroné/diagnóstico por imagen , Peroné/cirugía , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Rotación , Huesos Tarsianos/diagnóstico por imagen , Tomografía Computarizada por Rayos X
11.
Orthop J Sports Med ; 6(10): 2325967118801009, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30327787

RESUMEN

BACKGROUND: Imaging of the femoral trochlea has been inherently difficult because of its convex anatomy. PURPOSE/HYPOTHESIS: The purpose of this study was to compare the diagnostic utility of a standard axial magnetic resonance imaging (MRI) sequence with an axial-oblique MRI sequence of the knee for the detection of trochlear articular cartilage lesions on a high-field 3-T MRI scanner. We hypothesized that axial-oblique MRI scans of the knee obtained along the true axis of the trochlea would significantly improve the detection of high-grade cartilage lesions. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: Patients who underwent MRI and subsequent surgery for any indication were prospectively enrolled into this study between June 2014 and February 2015. The articular cartilage of the trochlea was evaluated independently by 3 raters on axial and axial-oblique MRI and compared with arthroscopic findings (gold standard). The interrater and intrarater reliability of mild (International Cartilage Repair Society [ICRS] grades 1 or 2) and severe (ICRS grades 3 or 4) lesions on MRI were assessed as well as the sensitivity, specificity, positive predictive value, and negative predictive value. RESULTS: A total of 99 knees in 96 patients were included in the study. Interrater and intrarater agreement for the identification of severe lesions were moderate to good on the proximal trochlea and fair to moderate on the distal trochlea. No significant differences in sensitivity were found between axial and axial-oblique scans for any grade of lesion (55% vs 51%, respectively; P = .700) or for severe lesions (61% vs 52%, respectively; P = .289). Similarly, specificity for detecting severe lesions was not significantly different between axial and axial-oblique scans (95% vs 87%, respectively; P = .219). Last, no significant differences in sensitivity or specificity were found between MRI sequences when separately evaluating proximal and distal trochlear lesions (all P > .05). CONCLUSION: The axial-oblique sequence was unable to improve the sensitivity of MRI in detecting articular cartilage lesions on the trochlea. Both conventional axial and axial-oblique sequences, reviewed independently of the complete MRI series, had low sensitivity in detecting trochlear articular cartilage lesions. For this reason, clinicians should utilize all MRI planes to evaluate the articular cartilage of the trochlea. Future studies should focus on improving MRI techniques for detecting and characterizing cartilage lesions of the trochlea.

12.
Skeletal Radiol ; 47(5): 671-682, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29196823

RESUMEN

OBJECTIVE: The purpose of this study was to develop quantitative T2 mapping methodology in asymptomatic shoulders for the entire mappable region of the glenohumeral cartilage in the coronal and sagittal planes, to assess the feasibility and limitations of the development of a diagnostic tool for future application in symptomatic patients. MATERIALS AND METHODS: Twenty-one asymptomatic volunteers underwent sagittal and coronal glenohumeral T2 mapping, as the spherical geometry of the humeral head obviates the need to evaluate the entire glenohumeral cartilage in a single plane. The humeral head cartilage orthogonal to the mapping plane was manually segmented in the sagittal and coronal planes, whereas the glenoid cartilage was segmented in the coronal plane. Cartilage T2 summary statistics were calculated and coverage in each mapping plane was qualitatively assessed. RESULTS: The mean ± standard deviation of the glenoid cartilage T2 was 38 ± 2 ms. The coronal and sagittal mapping planes captured different regions of the humeral head with some overlap: inferior-medial to superior-lateral versus superior/superior-lateral to anterior-lateral and posterior-lateral respectively. The mean humeral head cartilage T2 in the coronal plane was 41 ± 3 ms, which was significantly different (p < 0.05) from the sagittal plane mean of 34 ± 2 ms. CONCLUSION: This study measured characteristic glenoid and humeral head cartilage T2 values over the area mappable with two planes. Importantly, this study demonstrated that two-dimensional mapping in a single plane or two combined planes cannot capture the entirety of the semi-spherical humeral head cartilage. This highlights the need for three-dimensional T2 mapping techniques in the shoulder.


Asunto(s)
Cartílago Articular/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Articulación del Hombro/diagnóstico por imagen , Adulto , Femenino , Voluntarios Sanos , Humanos , Masculino , Estudios Prospectivos
13.
Foot Ankle Int ; 38(6): 677-683, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28552042

RESUMEN

BACKGROUND: Peroneal tendon evaluation is particularly demanding using current magnetic resonance imaging (MRI) techniques because of their curving path around the lateral malleolus. Quantifiable, objective data on the health of the peroneal tendons could be useful for improving diagnosis of tendon pathology and tracking post-treatment responses. The purpose of this study was to establish a method and normative T2-star (T2*) values for the peroneal tendons in a screened asymptomatic cohort using clinically reproducible subregions, providing a baseline for comparison with peroneal tendon pathology. METHODS: Unilateral ankle scans were acquired for 26 asymptomatic volunteers with a 3-Tesla MRI system using a T2* mapping sequence in the axial and sagittal planes. The peroneus brevis and peroneus longus tendons were manually segmented and subregions were isolated in the proximity of the lateral malleolus. Summary statistics for T2* values were calculated. RESULTS: The peroneus brevis tendon exhibited a mean T2* value of 12 ms and the peroneus longus tendon was 11 ms. Subregions distal to the lateral malleolus had significantly higher T2* values ( P < .05) than the subregions proximal in both tendons, in both the axial and sagittal planes. CONCLUSION: Peroneal tendon regions distal to the inferior tip of the lateral malleolus had significantly higher T2* values than those regions proximal, which could be related to anatomical differences along the tendon. CLINICAL RELEVANCE: This study provides a quantitative method and normative baseline T2* mapping values for comparison with symptomatic clinically compromised peroneal tendon patients.


Asunto(s)
Traumatismos del Tobillo/fisiopatología , Articulación del Tobillo/fisiopatología , Peroné/fisiología , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/fisiología , Traumatismos de los Tendones/diagnóstico , Traumatismos de los Tendones/patología , Tendones/patología , Humanos , Extremidad Inferior , Músculo Esquelético/patología , Estudios Retrospectivos , Tendones/cirugía
14.
J Biomed Mater Res B Appl Biomater ; 104(1): 133-40, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25677393

RESUMEN

With recent improvements to the properties of ultra-high molecular weight polyethylene (UHMWPE) used in joint replacements, prosthetic knee and hip longevity may extend beyond two decades. However, it is difficult and costly to replicate such a long in vivo lifetime using clinically relevant in vitro wear testing approaches such as walking gait joint simulators. We advance a wear test intermediate in complexity between pin-on-disk and knee joint simulator tests. The test uses a surrogate contact pair, consisting of a surrogate femoral and tibial specimen that replicate the contact mechanics of any full-scale knee condyle contact pair. The method is implemented in a standard multi-directional pin-on-disk wear test machine, and we demonstrate its application via a two-million-cycle wear test of three different UHMWPE formulations. Further, we demonstrate the use of digital photography and image processing to accurately quantify fatigue damage based on the reduced transmission of light through a damage area in a UHMWPE specimen. The surrogate contact pairs replicate the knee condyle contact areas within -3% to +12%. The gravimetric wear test results reflect the dose of crosslinking radiation applied to the UHMWPE: 35 kGy yielded a wear rate of 7.4 mg/Mcycles, 55 kGy yielded 1.0 mg/Mcycles, and 75 kGy (applied to a 0.1% vitamin E stabilized UHMWPE) yielded 1.5 mg/Mcycles. A precursor to spalling fatigue is observed and precisely measured in the radiation-sterilized (35 kGy) and aged UHMWPE specimen. The presented techniques can be used to evaluate the high-cycle fatigue performance of arbitrary knee condyle contact pairs under design-specific contact stresses, using existing wear test machines. This makes the techniques more economical and well-suited to standardized comparative testing.


Asunto(s)
Articulación de la Rodilla , Prótesis de la Rodilla , Polietilenos , Humanos
15.
J Mech Behav Biomed Mater ; 54: 106-14, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26451704

RESUMEN

A major limiting factor to the longevity of prosthetic knee joints is fatigue crack damage of the polyethylene tibial insert. Existing methods to quantify fatigue crack damage have several shortcomings, including limited resolution, destructive testing approach, and high cost. We propose an alternative fatigue crack damage visualization and measurement method that addresses the shortcomings of existing methods. This new method is based on trans-illumination and differs from previously described methods in its ability to non-destructively measure subsurface fatigue crack damage while using a simple and cost-effective bench-top set-up. We have evaluated this method to measure fatigue crack damage in two tibial inserts. This new method improves on existing image-based techniques due to its usability for subsurface damage measurement and its decreased reliance on subjective damage identification and measurement.


Asunto(s)
Prótesis Articulares , Ensayo de Materiales/métodos , Polietileno , Estrés Mecánico , Tibia , Análisis Costo-Beneficio , Procesamiento de Imagen Asistido por Computador , Articulación de la Rodilla , Ensayo de Materiales/economía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...