Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Phys Rev E ; 102(5-1): 053203, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33327061

RESUMEN

Boron carbide (B_{4}C) is of both fundamental scientific and practical interest due to its structural complexity and how it changes upon compression, as well as its many industrial uses and potential for use in inertial confinement fusion (ICF) and high-energy density physics experiments. We report the results of a comprehensive computational study of the equation of state (EOS) of B_{4}C in the liquid, warm dense matter, and plasma phases. Our calculations are cross-validated by comparisons with Hugoniot measurements up to 61 megabar from planar shock experiments performed at the National Ignition Facility (NIF). Our computational methods include path integral Monte Carlo, activity expansion, as well as all-electron Green's function Korringa-Kohn-Rostoker and molecular dynamics that are both based on density functional theory. We calculate the pressure-internal energy EOS of B_{4}C over a broad range of temperatures (∼6×10^{3}-5×10^{8} K) and densities (0.025-50 g/cm^{3}). We assess that the largest discrepancies between theoretical predictions are ≲5% near the compression maximum at 1-2×10^{6} K. This is the warm-dense state in which the K shell significantly ionizes and has posed grand challenges to theory and experiment. By comparing with different EOS models, we find a Purgatorio model (LEOS 2122) that agrees with our calculations. The maximum discrepancies in pressure between our first-principles predictions and LEOS 2122 are ∼18% and occur at temperatures between 6×10^{3}-2×10^{5} K, which we believe originate from differences in the ion thermal term and the cold curve that are modeled in LEOS 2122 in comparison with our first-principles calculations. To account for potential differences in the ion thermal term, we have developed three new equation-of-state models that are consistent with theoretical calculations and experiment. We apply these new models to 1D hydrodynamic simulations of a polar direct-drive NIF implosion, demonstrating that these new models are now available for future ICF design studies.

2.
Phys Rev E ; 98(2-1): 023205, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30253522

RESUMEN

We report a theoretical equation of state (EOS) table for boron across a wide range of temperatures (5.1×10^{4}-5.2×10^{8} K) and densities (0.25-49 g/cm^{3}) and experimental shock Hugoniot data at unprecedented high pressures (5608±118 GPa). The calculations are performed with first-principles methods combining path-integral Monte Carlo (PIMC) at high temperatures and density-functional-theory molecular-dynamics (DFT-MD) methods at lower temperatures. PIMC and DFT-MD cross-validate each other by providing coherent EOS (difference <1.5 Hartree/boron in energy and <5% in pressure) at 5.1×10^{5} K. The Hugoniot measurement is conducted at the National Ignition Facility using a planar shock platform. The pressure-density relation found in our shock experiment is on top of the shock Hugoniot profile predicted with our first-principles EOS and a semiempirical EOS table (LEOS 50). We investigate the self-diffusivity and the effect of thermal and pressure-driven ionization on the EOS and shock compression behavior in high-pressure and -temperature conditions. We also study the sensitivity of a polar direct-drive exploding pusher platform to pressure variations based on applying pressure multipliers to LEOS 50 and by utilizing a new EOS model based on our ab initio simulations via one-dimensional radiation-hydrodynamic calculations. The results are valuable for future theoretical and experimental studies and engineering design in high-energy density research.

3.
Sci Adv ; 3(1): e1601558, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28097218

RESUMEN

Ultrahigh-energy density (UHED) matter, characterized by energy densities >1 × 108 J cm-3 and pressures greater than a gigabar, is encountered in the center of stars and inertial confinement fusion capsules driven by the world's largest lasers. Similar conditions can be obtained with compact, ultrahigh contrast, femtosecond lasers focused to relativistic intensities onto targets composed of aligned nanowire arrays. We report the measurement of the key physical process in determining the energy density deposited in high-aspect-ratio nanowire array plasmas: the energy penetration. By monitoring the x-ray emission from buried Co tracer segments in Ni nanowire arrays irradiated at an intensity of 4 × 1019 W cm-2, we demonstrate energy penetration depths of several micrometers, leading to UHED plasmas of that size. Relativistic three-dimensional particle-in-cell simulations, validated by these measurements, predict that irradiation of nanostructures at intensities of >1 × 1022 W cm-2 will lead to a virtually unexplored extreme UHED plasma regime characterized by energy densities in excess of 8 × 1010 J cm-3, equivalent to a pressure of 0.35 Tbar.

4.
Neuroophthalmology ; 39(3): 147-151, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27928348

RESUMEN

Acquired involuntary eye movement disorders, including noncomitant strabismus, nystagmus, and saccadic dyskinesia, are common ocular manifestations of many neurodegenerative diseases. These patients may experience visual symptoms, such as blurred vision, diplopia, and oscillopsia, which can significantly impact their use of vision. The goal of the management for these patients is to reduce the visual symptoms using any combination of available management strategies. This case report discusses the effective optical management using the combination of spectacle monovision correction and yoked prism to improve visual symptoms in a patient with olivopontocerebellar atrophy.

5.
Phys Rev Lett ; 111(23): 233902, 2013 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-24476271

RESUMEN

We demonstrate strong stimulated inelastic x-ray scattering by resonantly exciting a dense gas target of neon with femtosecond, high-intensity x-ray pulses from an x-ray free-electron laser (XFEL). A small number of lower energy XFEL seed photons drive an avalanche of stimulated resonant inelastic x-ray scattering processes that amplify the Raman scattering signal by several orders of magnitude until it reaches saturation. Despite the large overall spectral width, the internal spiky structure of the XFEL spectrum determines the energy resolution of the scattering process in a statistical sense. This is demonstrated by observing a stochastic line shift of the inelastically scattered x-ray radiation. In conjunction with statistical methods, XFELs can be used for stimulated resonant inelastic x-ray scattering, with spectral resolution smaller than the natural width of the core-excited, intermediate state.

6.
Nature ; 481(7382): 488-91, 2012 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-22281598

RESUMEN

Since the invention of the laser more than 50 years ago, scientists have striven to achieve amplification on atomic transitions of increasingly shorter wavelength. The introduction of X-ray free-electron lasers makes it possible to pump new atomic X-ray lasers with ultrashort pulse duration, extreme spectral brightness and full temporal coherence. Here we describe the implementation of an X-ray laser in the kiloelectronvolt energy regime, based on atomic population inversion and driven by rapid K-shell photo-ionization using pulses from an X-ray free-electron laser. We established a population inversion of the Kα transition in singly ionized neon at 1.46 nanometres (corresponding to a photon energy of 849 electronvolts) in an elongated plasma column created by irradiation of a gas medium. We observed strong amplified spontaneous emission from the end of the excited plasma. This resulted in femtosecond-duration, high-intensity X-ray pulses of much shorter wavelength and greater brilliance than achieved with previous atomic X-ray lasers. Moreover, this scheme provides greatly increased wavelength stability, monochromaticity and improved temporal coherence by comparison with present-day X-ray free-electron lasers. The atomic X-ray lasers realized here may be useful for high-resolution spectroscopy and nonlinear X-ray studies.

7.
Phys Rev Lett ; 105(4): 043003, 2010 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-20867841

RESUMEN

The Linac Coherent Light Source is an x-ray free-electron laser that recently demonstrated lasing in the 1.5-15 Å wavelength range. We report on luminescence measurements of a molecular nitrogen gas irradiated by ∼2 mJ, 80 fs x-ray pulses at energies of 0.83, 2.7, and 8.3 keV. These results provide a direct test of our current understanding of photoabsorption, electron dynamics, and fluorescence processes for such intense, ultrashort x-ray pulses. At 0.83 keV, the duration of the fluorescence signal depends strongly on space-charge effects. At 8.3 keV, space-charge effects are weak, and the signal duration is determined by the Auger electron dynamics.

8.
Phys Rev Lett ; 102(20): 205004, 2009 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-19519037

RESUMEN

We use classical molecular dynamics to investigate electron-ion temperature equilibration in a two-temperature SF6 plasma. We choose a density of 1.0 x 10;{19}SF_{6} molecules per cm;{3} and initial temperatures of T_{e} = 100 eV and T_{S} = T_{F} = 15 eV, in accordance with experiments currently underway at Los Alamos National Laboratory. Our computed relaxation time lies between two oft-used variants of the Landau-Spitzer relaxation formula which invoke static screening. Discrepancies are also found when comparing to the predictions made by more recent theoretical approaches. These differences should be large enough to be measured in the upcoming experiments.

9.
Optom Vis Sci ; 85(4): 255-61, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18382340

RESUMEN

PURPOSE: The Convergence Insufficiency Treatment Trial (CITT) Investigator Group conducted a preliminary study assessing the effectiveness of home-based push-up therapy and office-based vision therapy/orthoptics for the treatment of convergence insufficiency (CI). The CITT group developed a placebo therapy program that was designed to simulate real vision therapy/orthoptics. The purpose of this paper is to evaluate the effectiveness of this placebo therapy program in maintaining masking of subjects randomized to the office-based treatment arms (real or placebo). METHODS: Subjects (ages 9 to 30 years) were enrolled, stratified into two groups by age, and then randomly assigned to one of three treatment groups: pencil push-up therapy, office-based vision therapy/orthoptics, or office-based placebo vision therapy/orthoptics. At the end of treatment, subjects in the two office-based therapy groups (placebo and real) were asked: (1) which treatment do you think you received? and (2) how sure are you about your answer? RESULTS: Ninety-five percent of subjects assigned to real therapy and 83% assigned to placebo therapy thought they were in the real therapy group. Of the subjects who thought they received real therapy, 90% assigned to real therapy and 89% assigned to placebo therapy were "somewhat sure," "pretty sure," or "very sure" of their answer. Those assigned to real therapy had more responses in the "very sure" category. CONCLUSION: The CITT placebo therapy program was effective in maintaining subject masking in this multicenter clinical trial.


Asunto(s)
Estudios Multicéntricos como Asunto/normas , Trastornos de la Motilidad Ocular/terapia , Placebos , Ensayos Clínicos Controlados Aleatorios como Asunto/normas , Trastornos de la Visión/terapia , Adolescente , Adulto , Niño , Computadores , Estudios de Factibilidad , Humanos , Estudios Multicéntricos como Asunto/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto/métodos
10.
Phys Rev E Stat Nonlin Soft Matter Phys ; 76(4 Pt 2): 046403, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17995118

RESUMEN

Soft-x-ray free-electron lasers have enabled materials studies in which structural information is obtained faster than the relevant probe-induced damage mechanisms. We present a continuum model to describe the damage process based on hot-dense plasma theory, which includes a description of the energy deposition in the samples, the subsequent dynamics of the sample, and the detector signal. We compared the model predictions with experimental data and mostly found reasonable agreement. In view of future free-electron-laser performance, the model was also used to predict damage dynamics of samples and optical elements at shorter wavelengths and larger photon fluences than currently available.

11.
Phys Rev Lett ; 98(19): 198302, 2007 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-17677667

RESUMEN

Short and intense x-ray pulses may be used for atomic-resolution diffraction imaging of single biological molecules. Radiation damage and a low signal-to-noise ratio impose stringent pulse requirements. In this Letter, we describe methods for decreasing the damage and improving the signal by encapsulating the molecule in a sacrificial layer (tamper) that reduces atomic motion and by postprocessing the pulse-averaged diffraction pattern to correct for ionization damage. Simulations show that these methods greatly improve the image quality.


Asunto(s)
Biofisica/métodos , Simulación por Computador , Modelos Teóricos , ADN/química , ADN/efectos de la radiación , Proteínas/química , Proteínas/efectos de la radiación , Difracción de Rayos X
12.
Nature ; 448(7154): 676-9, 2007 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-17687320

RESUMEN

Extremely intense and ultrafast X-ray pulses from free-electron lasers offer unique opportunities to study fundamental aspects of complex transient phenomena in materials. Ultrafast time-resolved methods usually require highly synchronized pulses to initiate a transition and then probe it after a precisely defined time delay. In the X-ray regime, these methods are challenging because they require complex optical systems and diagnostics. Here we propose and apply a simple holographic measurement scheme, inspired by Newton's 'dusty mirror' experiment, to monitor the X-ray-induced explosion of microscopic objects. The sample is placed near an X-ray mirror; after the pulse traverses the sample, triggering the reaction, it is reflected back onto the sample by the mirror to probe this reaction. The delay is encoded in the resulting diffraction pattern to an accuracy of one femtosecond, and the structural change is holographically recorded with high resolution. We apply the technique to monitor the dynamics of polystyrene spheres in intense free-electron-laser pulses, and observe an explosion occurring well after the initial pulse. Our results support the notion that X-ray flash imaging can be used to achieve high resolution, beyond radiation damage limits for biological samples. With upcoming ultrafast X-ray sources we will be able to explore the three-dimensional dynamics of materials at the timescale of atomic motion.


Asunto(s)
Holografía/métodos , Poliestirenos/química , Rayos X , Electrones , Rayos Láser , Microesferas , Factores de Tiempo
13.
J AAPOS ; 11(3): 300-2, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17572346

RESUMEN

Our objective was to determine whether the use of unilateral atropine as amblyopia therapy leads to an asymmetric change in refractive error compared with patching. Patients were enrolled in a clinical trial in which atropine 1% solution or occlusion with an adhesive patch was administered daily to the sound eye of children 3 to less than 7 years of age for a period of at least 6 months to a maximum of 2 years. Refractive error at entry and at 2 years was determined with cycloplegic retinoscopy for 282 of 419 patients enrolled. The baseline mean refractive error was + 3.13 diopters (D) in patients assigned randomly to receive atropine and + 2.58 D in patients assigned randomly to wear the patch. The mean change in refractive error of the sound eye was + 0.10 D in the atropine group (N = 134) and + 0.08 D in the patch group (N = 148). Patients also were subdivided into those treated with atropine only (n = 41) and patching only (n = 64) because some children changed treatments during their study participation. The mean change for the sound eyes was -0.21 D for the patients receiving only atropine and -0.06 D for the patients receiving only patching. Unilateral atropine applied to the sound eye compared with occlusion was not associated with any adverse effect on refractive error following up to 2 years of treatment.


Asunto(s)
Ambliopía/terapia , Atropina/uso terapéutico , Midriáticos/uso terapéutico , Errores de Refracción/fisiopatología , Privación Sensorial , Ambliopía/fisiopatología , Niño , Preescolar , Humanos , Luz , Refracción Ocular
14.
Phys Rev Lett ; 98(14): 145502, 2007 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-17501285

RESUMEN

At the recently built FLASH x-ray free-electron laser, we studied the reflectivity of Si/C multilayers with fluxes up to 3 x 10(14) W/cm2. Even though the nanostructures were ultimately completely destroyed, we found that they maintained their integrity and reflectance characteristics during the 25-fs-long pulse, with no evidence for any structural changes over lengths greater than 3 A. This experiment demonstrates that with intense ultrafast pulses, structural damage does not occur during the pulse, giving credence to the concept of diffraction imaging of single macromolecules.

15.
Optometry ; 77(12): 590-608, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17157241

RESUMEN

PURPOSE: Fixation disparity measurement as a tool for analyzing the binocular visual system has taken very different approaches in the United States and Central Europe. In the United States, testing has primarily followed a motor approach, and resulting management has followed parameters established by graphical analysis closely. In German-speaking countries, a strong sensory-based analysis has been popular for decades, utilizing equipment rarely seen in the United States. Management in these countries has been almost exclusively directed toward prismatic prescription. METHODS: This report examines the instrumentation, underlying strategies, and management used in both the motor and sensory approaches to fixation disparity analysis. Testing protocols and management options are detailed for each approach. CONCLUSION: Although both approaches agree that fixation disparity has the potential to reveal a more realistic view of binocular system functioning under normal viewing conditions than other systems of analysis, the approaches diverge in some very important ways, particularly in the understanding of the development of fixation disparity and its management. Whereas the philosophy underlying testing and management of the motor-based approach will be familiar to most clinicians in the United States, the sensory approach offers a very different perspective. It views the development of fixation disparity as a shift of correspondence within Panum's area. In effect, this may be thought of as the oxymoron "a normal, anomalous correspondence"; that is, a shift of correspondence occurring in nonstrabismic patients. Management in these cases is based on accurate prism prescription to re-establish bifoveal fusion.


Asunto(s)
Astenopía/fisiopatología , Disparidad Visual/fisiología , Astenopía/diagnóstico , Astenopía/terapia , Anteojos , Humanos , Pronóstico , Pruebas de Visión , Visión Binocular/fisiología
17.
Phys Rev E Stat Nonlin Soft Matter Phys ; 71(6 Pt 1): 061919, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16089777

RESUMEN

In this paper we estimate the required pulse parameters for the future application of x-ray free electron lasers to imaging single biological molecules. The parameters are determined by a tradeoff between minimizing image degradation due to damage and maximizing the image signal-to-noise ratio. We discuss several means to alleviate the pulse requirements, and compare the requirements with parameters of two planned x-ray lasers.


Asunto(s)
Biopolímeros/química , Biopolímeros/efectos de la radiación , Modelos Químicos , Difracción de Rayos X/métodos , Biopolímeros/análisis , Simulación por Computador , Transferencia Lineal de Energía , Conformación Molecular/efectos de la radiación , Tamaño de la Partícula , Rayos X
18.
Optom Vis Sci ; 82(7): 583-95, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16044063

RESUMEN

PURPOSE: : The purpose of this article is to compare vision therapy/orthoptics, pencil pushups, and placebo vision therapy/orthoptics as treatments for symptomatic convergence insufficiency in adults 19 to 30 years of age. METHODS: : In a randomized, multicenter clinical trial, 46 adults 19 to 30 years of age with symptomatic convergence insufficiency were randomly assigned to receive 12 weeks of office-based vision therapy/orthoptics, office-based placebo vision therapy/orthoptics, or home-based pencil pushups. The primary outcome measure was the symptom score on the Convergence Insufficiency Symptom Survey. Secondary outcome measures were the near point of convergence and positive fusional vergence at near. RESULTS: : Only patients in the vision therapy/orthoptics group demonstrated statistically and clinically significant changes in the near point of convergence (12.8 cm to 5.3 cm, p = 0.002) and positive fusional vergence at near (11.3Delta to 29.7Delta, p = 0.001). Patients in all three treatment arms demonstrated statistically significant improvement in symptoms with 42% in office-based vision therapy/orthoptics, 31% in office-based placebo vision therapy/orthoptics, and 20% in home-based pencil pushups achieving a score <21 (our predetermined criteria for elimination of symptoms) at the 12-week visit. DISCUSSION: : In this study, vision therapy/orthoptics was the only treatment that produced clinically significant improvements in the near point of convergence and positive fusional vergence. However, over half of the patients in this group (58%) were still symptomatic at the end of treatment, although their symptoms were significantly reduced. All three groups demonstrated statistically significant changes in symptoms with 42% in office-based vision therapy/orthoptics, 31% in office-based placebo vision therapy/orthoptics, and 20% in home-based pencil push-ups meeting our criteria for elimination of symptoms.


Asunto(s)
Trastornos de la Motilidad Ocular/terapia , Ortóptica/métodos , Adulto , Convergencia Ocular/fisiología , Determinación de Punto Final , Femenino , Humanos , Masculino , Efecto Placebo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Agudeza Visual
19.
Arch Ophthalmol ; 123(1): 14-24, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15642806

RESUMEN

OBJECTIVE: To compare vision therapy/orthoptics, pencil push-ups, and placebo vision therapy/orthoptics as treatments for symptomatic convergence insufficiency in children 9 to 18 years of age. METHODS: In a randomized, multicenter clinical trial, 47 children 9 to 18 years of age with symptomatic convergence insufficiency were randomly assigned to receive 12 weeks of office-based vision therapy/orthoptics, office-based placebo vision therapy/orthoptics, or home-based pencil push-ups therapy. MAIN OUTCOME MEASURES: The primary outcome measure was the symptom score on the Convergence Insufficiency Symptom Survey. Secondary outcome measures were the near point of convergence and positive fusional vergence at near. RESULTS: Symptoms, which were similar in all groups at baseline, were significantly reduced in the vision therapy/orthoptics group (mean symptom score decreased from 32.1 to 9.5) but not in the pencil push-ups (mean symptom score decreased from 29.3 to 25.9) or placebo vision therapy/orthoptics groups (mean symptom score decreased from 30.7 to 24.2). Only patients in the vision therapy/orthoptics group demonstrated both statistically and clinically significant changes in the clinical measures of near point of convergence (from 13.7 cm to 4.5 cm; P < .001) and positive fusional vergence at near (from 12.5 prism diopters to 31.8 prism diopters; P < .001). CONCLUSIONS: In this pilot study, vision therapy/orthoptics was more effective than pencil push-ups or placebo vision therapy/orthoptics in reducing symptoms and improving signs of convergence insufficiency in children 9 to 18 years of age. Neither pencil push-ups nor placebo vision therapy/orthoptics was effective in improving either symptoms or signs associated with convergence insufficiency.


Asunto(s)
Convergencia Ocular , Trastornos de la Motilidad Ocular/terapia , Ortóptica/métodos , Adolescente , Niño , Femenino , Humanos , Masculino , Trastornos de la Motilidad Ocular/diagnóstico , Oftalmología/métodos , Cooperación del Paciente , Satisfacción del Paciente , Selección de Paciente , Proyectos Piloto , Visión Binocular , Agudeza Visual
20.
Ophthalmic Physiol Opt ; 24(5): 384-90, 2004 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-15315652

RESUMEN

PURPOSE: To assess the validity and reliability of the revised Convergence Insufficiency Symptom Survey (CISS) in adults aged 19-30 years. The CISS was developed to be the primary outcome measure for studies evaluating various treatments for convergence insufficiency (CI). METHODS: CISS mean scores from adults with symptomatic CI and adults with normal binocular vision (NBV) were compared to assess the survey's validity. Adults with symptomatic CI were given the CISS twice to evaluate reliability, which was assessed using intraclass correlation coefficient (ICC) and 95% limits of agreement. RESULTS: Forty-six adults with CI and 46 adults with NBV participated in the study. The mean CISS score for the CI group was 37.3 (S.D. = 9.3) and 11.0 (S.D. = 8.2) for the NBV group. These mean values were significantly different (p < 0.0001). Good discrimination (sensitivity = 97.8%, specificity = 87%) was obtained using a score of 21 or higher. For the CI group the ICC was 0.885 (95% CI of 0.798, 0.936) and the 95% limits of agreement were -9.0 to 7.6. CONCLUSIONS: Adults with symptomatic CI had a significantly higher CISS score than adults with NBV. The results of the study demonstrate that the CISS is a valid and reliable instrument that can be used clinically or as an outcome measure for research studies of adults with CI.


Asunto(s)
Convergencia Ocular/fisiología , Trastornos de la Motilidad Ocular/diagnóstico , Acomodación Ocular/fisiología , Adulto , Femenino , Humanos , Masculino , Vigilancia de la Población/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Encuestas y Cuestionarios , Visión Binocular/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA