Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Intervalo de año de publicación
1.
ACS Biomater Sci Eng ; 10(5): 3097-3107, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38591966

RESUMEN

To develop a peri-implantitis model in a Gottingen minipig and evaluate the effect of local application of salicylic acid poly(anhydride-ester) (SAPAE) on peri-implantitis progression in healthy, metabolic syndrome (MS), and type-2 diabetes mellitus (T2DM) subjects. Eighteen animals were allocated to three groups: (i) control, (ii) MS (diet for obesity induction), and (iii) T2DM (diet plus streptozotocin for T2DM induction). Maxillary and mandible premolars and first molar were extracted. After 3 months of healing, four implants per side were placed in both jaws of each animal. After 2 months, peri-implantitis was induced by plaque formation using silk ligatures. SAPAE polymer was mixed with mineral oil (3.75 mg/µL) and topically applied biweekly for up to 60 days to halt peri-implantitis progression. Periodontal probing was used to assess pocket depth over time, followed by histomorphologic analysis of harvested samples. The adopted protocol resulted in the onset of peri-implantitis, with healthy minipigs taking twice as long to reach the same level of probing depth relative to MS and T2DM subjects (∼3.0 mm), irrespective of jaw. In a qualitative analysis, SAPAE therapy revealed decreased levels of inflammation in the normoglycemic, MS, and T2DM groups. SAPAE application around implants significantly reduced the progression of peri-implantitis after ∼15 days of therapy, with ∼30% lower probing depth for all systemic conditions and similar rates of probing depth increase per week between the control and SAPAE groups. MS and T2DM conditions presented a faster progression of the peri-implant pocket depth. SAPAE treatment reduced peri-implantitis progression in healthy, MS, and T2DM groups.


Asunto(s)
Periimplantitis , Ácido Salicílico , Porcinos Enanos , Animales , Porcinos , Periimplantitis/tratamiento farmacológico , Periimplantitis/patología , Ácido Salicílico/administración & dosificación , Ácido Salicílico/farmacología , Ácido Salicílico/uso terapéutico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Modelos Animales de Enfermedad , Progresión de la Enfermedad , Hiperglucemia/tratamiento farmacológico , Masculino , Diabetes Mellitus Experimental/tratamiento farmacológico , Síndrome Metabólico/tratamiento farmacológico , Síndrome Metabólico/metabolismo , Implantes Dentales
2.
J Mech Behav Biomed Mater ; 143: 105872, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37201226

RESUMEN

The use of identical prosthetic components for all implant diameters could reduce the production costs by companies and the complexity of component selection for the clinician and his team. However, it would imply in reduction of thickness of the cervical walls of tapered internal connection implants, which could compromise the reliability of narrow and extra-narrow implants. Therefore, this study aims to evaluate the probability of survival and failure modes of extra-narrow implant systems with the same internal diameter as standard-diameter implants using the same prosthetic components. It was used eigth different implant system configurations, including narrow (Ø 3.3 mm) (N) extra-narrow (Ø 2.9 mm) (EN) and extra-narrow-scalloped (Ø 2.9 mm) (ENS) implants, both with cementable abutments (Ce) or titanium bases (Tib) and one-piece implants (Ø 2.5 mm and Ø 3.0 mm) (OP) (Medens, Itu, SP, Brazil), comprising the following groups: OP 3.0; OP 2.5; N Ce; N Tib; EN Ce, EN Tib, ENS-Ce and ENS-Tib. The implants were embedded using polymethylmethacrylate acrylic resin in a 15 mm matrix. Standardized maxillary central incisor crowns were virtually designed and milled to fit on the different studied abutments and cemented using a dual self-adhesive resin cement. The specimens were submitted to SSALT (Step Stress Accelerated Life Testing) at 15 Hz in water until failure or suspension of the test, until a maximum load of 500 N. Fractographic analysis of the failed specimens were realized in scanning electron microscopy. All implant systems demonstrated high probability of survival (90-100%) for missions at 50 and 100 N and values of characteristic strength superior to 139 N. Failure modes were restricted to the abutment in all the implant configurations tested. Therefore, the use extra-narrow implants with standardized prosthetic components for different implant diameters is a viable option for the replacement of anterior teeth.


Asunto(s)
Coronas , Incisivo , Reproducibilidad de los Resultados , Ensayo de Materiales , Titanio , Análisis del Estrés Dental , Fracaso de la Restauración Dental , Circonio
3.
Dent Mater ; 36(9): 1190-1200, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32561117

RESUMEN

OBJECTIVE: To synthesize a zirconia toughened alumina (ZTA) composite with 70% alumina reinforced by 30% zirconia for dental applications and to characterize its microstructure and optical properties for comparison with the isolated counterpart materials and a first-generation 3Y-TZP. METHODS: Disc-shaped specimens were divided in four groups (n = 70/material): (1) 3YSB-E (first generation 3Y-TZP), (2) Zpex (second generation 3Y-TZP), (3) alumina, and (4) ZTA-Zpex 70/30. After synthesis, ceramic powders were pressed, and green-body samples sintered following a predetermined protocol. Specimens were polished to obtain a mirror surface finish. Apparent density was measured by Archimedes principle. X-ray diffraction (XRD) and scanning electron microscope (SEM) were used to characterize the crystalline content and microstructure. Reflectance tests were performed to determine the contrast-ratio (CR) and translucency-parameter (TP). Mechanical properties were assessed by biaxial flexural strength (BFS) test. All analyses were conducted before and after artificial aging (20 h, 134 °C, 2.2 bar). Optical parameters were evaluated through repeated-measures analysis of variance and Tukey tests (p < 0.05). BFS data were analyzed using Weibull statistics (95% CI). RESULTS: High density values (95-99%) were found for all ceramic materials and SEM images exhibited a dense microstructure. While XRD patterns revealed the preservation of crystalline content in the ZTA composite, an increase in the monoclinic peak was observed for pure zirconias after aging. Significantly higher CR and lower TP values were observed for the ZTA composite, followed by alumina, 3YSB-E, and Zpex. The highest characteristic stress was recorded for 3YSB-E, followed by intermediate values between ZTA and Zpex, and the lowest for alumina. Aging affected the optical and mechanical properties of both zirconias, while remained stable for ZTA composite and alumina. SIGNIFICANCE: The synthesis of experimental 70-30% ZTA composite was successful and its relevance for dental applications relies on its higher masking ability, aging resistance, and strength similar to zirconia.


Asunto(s)
Óxido de Aluminio , Circonio , Cerámica , Materiales Dentales , Ensayo de Materiales , Propiedades de Superficie , Itrio
4.
J Prosthodont ; 28(2): e552-e556, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29961986

RESUMEN

PURPOSE: To evaluate the pullout resistance of CAD/CAM implant-supported crowns cemented with provisional and definitive cements on Ti-base implant abutments. MATERIALS AND METHODS: Sixty crowns were milled for use in Ti-base implant abutments and divided (n = 15/group) according to material, as follows: (a) [Pr] Temporary acrylic resin; (b) [Co-Cr] Cobalt-Chromium alloy; (c) [Zr] polycrystalline zirconia; and (d) [Ti] titanium. The cementation was performed with RelyX Temp NE (RxT) cement or RelyX U200 self-etching resin cement, under a 50 N (5 kg) load for 10 minutes. Twenty-four hours after cementation, the crowns were subjected to the pullout test in a universal test machine, at a 1.0 mm/min crosshead speed. The tests were performed first without cement to evaluate frictional resistance (Baseline), then with provisional cement (RelyX Temp NE without cement again (Baseline After RxT), and finally with resin cement (U200). The results were analyzed by ANOVA and Tukey test (p < 0.05). RESULTS: Data evaluation as a function of cement type demonstrated the superiority of resin-based cements relative to provisional and baseline groups (p < 0.01). While Co-Cr crowns presented the highest pullout strength values, Pr showed the lowest values (data collapsed over cement) (p < 0.001). Retentiveness data as a function of both factors demonstrated similar pullout resistance between groups without cement (p < 0.001), except Zr baseline. Also, Co-Cr presented higher pullout strength compared to other materials. CONCLUSIONS: Self-adhesive resin cement exhibited superior retention compared to temporary cement, regardless of crown material. Co-Cr and titanium presented higher levels of retention to Ti-base abutment after being cemented.


Asunto(s)
Cementación/métodos , Diseño Asistido por Computadora , Coronas , Pilares Dentales , Materiales Dentales/química , Aleaciones de Cromo/química , Ensayo de Materiales , Cementos de Resina/química , Titanio/química , Circonio/química
5.
J Long Term Eff Med Implants ; 29(2): 141-149, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-32464023

RESUMEN

We evaluate bone remodeling and prostheses survival of immediately provisionalized with occlusal loading and delayed loading (DL) single implants placed in the posterior region after 1-yr follow-up in dental practices. Included in the study are patients selected to receive one regular implant (4 × 10 mm) for single tooth replacement in healed ridge sockets in the mandible and maxilla. Implants are immediately loaded or delayed functionally loaded with metal ceramic crowns, depending on peak insertion torque value. All implants are clinically and radiographically evaluated at T1, immediately postoperatively; T2, 60 d; T3, 180 d; and T4, 360 d. Measurements between implant platform and top of alveolar bone crest at distal and mesial areas are performed using periapical radiographs. Data are statistically evaluated through two-way repeated measures of analysis of variance following post hoc comparisons using the Tukey test (p < 0.05). Ten specialists working in ten different practices treat 36 patients who receive one implant each with internal conical connection (hybrid implant system, 4 × 10 mm) (Emfils; Itu, Brazil). Results show that bone-level alterations in immediate (IM; 0.56 mm; confidence interval [CI]: ± 0.21 mm) and delayed (0.65 mm; CI: ± 0.19 mm) groups are not significantly different (p = 0.515) during the course of the 1-yr observation period. In both groups, statistically significant progressive bone-level remodeling occurs through the evaluated follow-up time points (p < 0.047). All prostheses are rated "alpha," presenting 100% success at 1-yr follow-up. The loading method does not influence bone-remodeling levels around IM or DL at the posterior region after 1-yr follow-up. No prostheses complications are reported.


Asunto(s)
Remodelación Ósea , Implantes Dentales de Diente Único , Carga Inmediata del Implante Dental , Adulto , Anciano , Coronas , Prótesis Dental de Soporte Implantado , Femenino , Humanos , Estudios Longitudinales , Masculino , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Persona de Mediana Edad , Estudios Prospectivos , Alveolo Dental/cirugía
6.
J Appl Oral Sci ; 24(4): 317-24, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27556201

RESUMEN

OBJECTIVE: This study investigated the effect of the fluorescent dye rhodamine B (RB) for interfacial micromorphology analysis of dental composite restorations on water sorption/solubility (WS/WSL) and microtensile bond strength to dentin (µTBS) of a 3-step total etch and a 2-step self-etch adhesive system. MATERIAL AND METHODS: The adhesives Adper Scotchbond Multi-Purpose (MP) and Clearfil SE Bond (SE) were mixed with 0.1 mg/mL of RB. For the WS/WSL tests, cured resin disks (5.0 mm in diameter x 0.8 mm thick) were prepared and assigned into four groups (n=10): MP, MP-RB, SE, and SE-RB. For µTBS assessment, extracted human third molars (n=40) had the flat occlusal dentin prepared and assigned into the same experimental groups (n=10). After the bonding and restoration procedures, specimens were sectioned in rectangular beams, stored in water and tested after seven days or after 12 months. The failure mode of fractured specimens was qualitatively evaluated under optical microscope (x40). Data from WS/WSL and µTBS were assessed by one-way and three-way ANOVA, respectively, and Tukey's test (α=5%). RESULTS: RB increased the WSL of MP and SE. On the other hand, WS of both MP and SE was not affected by the addition of RB. No significance in µTBS between MP and MP-RB for seven days or one year was observed, whereas for SE a decrease in the µTBS means occurred in both storage times. CONCLUSIONS: RB should be incorporated into non-simplified DBSs with caution, as it can interfere with their physical-mechanical properties, leading to a possible misinterpretation of bonded interface.


Asunto(s)
Recubrimientos Dentinarios/química , Dentina/efectos de los fármacos , Colorantes Fluorescentes/química , Rodaminas/química , Agua/química , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Fracaso de la Restauración Dental , Humanos , Ensayo de Materiales , Microscopía Confocal , Reproducibilidad de los Resultados , Cementos de Resina/química , Solubilidad , Propiedades de Superficie , Resistencia a la Tracción , Factores de Tiempo
7.
J. appl. oral sci ; 24(4): 317-324, July-Aug. 2016. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: lil-792589

RESUMEN

ABSTRACT Objective This study investigated the effect of the fluorescent dye rhodamine B (RB) for interfacial micromorphology analysis of dental composite restorations on water sorption/solubility (WS/WSL) and microtensile bond strength to dentin (µTBS) of a 3-step total etch and a 2-step self-etch adhesive system. Material and Methods The adhesives Adper Scotchbond Multi-Purpose (MP) and Clearfil SE Bond (SE) were mixed with 0.1 mg/mL of RB. For the WS/WSL tests, cured resin disks (5.0 mm in diameter x 0.8 mm thick) were prepared and assigned into four groups (n=10): MP, MP-RB, SE, and SE-RB. For µTBS assessment, extracted human third molars (n=40) had the flat occlusal dentin prepared and assigned into the same experimental groups (n=10). After the bonding and restoration procedures, specimens were sectioned in rectangular beams, stored in water and tested after seven days or after 12 months. The failure mode of fractured specimens was qualitatively evaluated under optical microscope (x40). Data from WS/WSL and µTBS were assessed by one-way and three-way ANOVA, respectively, and Tukey’s test (α=5%). Results RB increased the WSL of MP and SE. On the other hand, WS of both MP and SE was not affected by the addition of RB. No significance in µTBS between MP and MP-RB for seven days or one year was observed, whereas for SE a decrease in the µTBS means occurred in both storage times. Conclusions RB should be incorporated into non-simplified DBSs with caution, as it can interfere with their physical-mechanical properties, leading to a possible misinterpretation of bonded interface.


Asunto(s)
Humanos , Rodaminas/química , Agua/química , Recubrimientos Dentinarios/química , Dentina/efectos de los fármacos , Colorantes Fluorescentes/química , Solubilidad , Propiedades de Superficie , Resistencia a la Tracción , Factores de Tiempo , Ensayo de Materiales , Reproducibilidad de los Resultados , Recubrimiento Dental Adhesivo/métodos , Microscopía Confocal , Resinas Compuestas/química , Cementos de Resina/química , Fracaso de la Restauración Dental
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...