Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
1.
Sci Transl Med ; 16(747): eadl4497, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748771

RESUMEN

Endovascular interventions are increasingly becoming the preferred approach for treating strokes and cerebral artery diseases. These procedures rely on sophisticated angiographical imaging guidance, which encounters challenges because of limited contrast and spatial resolution. Achieving a more precise visualization of the underlying arterial pathology and neurovascular implants is crucial for accurate procedural decision-making. In a human study involving 32 patients, we introduced the clinical application of a miniaturized endovascular neuro optical coherence tomography (nOCT) imaging probe. This technology was designed to navigate the tortuous paths of the cerebrovascular circulation and to offer high-resolution imaging in situ. The nOCT probe is compatible with standard neurovascular microcatheters, integrating with the procedural workflow used in clinical routine. Equipped with a miniaturized optical fiber and a distal lens, the probe illuminates the tissue and collects the backscattered, near-infrared light. While rotating the fiber and the lens at high speed, the probe is rapidly retracted, creating a spiral-shaped light pattern to comprehensively capture the arterial wall and implanted devices. Using nOCT, we demonstrated volumetric microscopy of cerebral arteries in patients undergoing endovascular procedures. We imaged the anterior and posterior circulation of the brain, including distal segments of the internal carotid and middle-cerebral arteries, as well as the vertebral, basilar, and posterior cerebral arteries. We captured a broad spectrum of neurovascular pathologies, such as brain aneurysms, ischemic stroke, arterial stenoses, dissections, and intracranial atherosclerotic disease. nOCT offered artifact-free, high-resolution visualizations of intracranial artery pathology and neurovascular devices.


Asunto(s)
Arterias Cerebrales , Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Humanos , Arterias Cerebrales/diagnóstico por imagen , Microscopía/métodos , Miniaturización , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos
2.
J Neurointerv Surg ; 15(12): 1181-1186, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37845019

RESUMEN

BACKGROUND: The anterior communicating artery (AComm) region is the most common site of intracranial aneurysms, with increased rupture risk compared with other locations. Overall, flow diverters present as a safe and efficacious treatment for intracranial aneurysms, but there is paucity of data for their use in the treatment of unruptured AComm aneurysms. We present the largest multicentric analysis evaluating the outcomes of flow diverters in AComm aneurysm treatment. METHODS: Databases from 10 centers were retrospectively reviewed for unruptured AComm aneurysms treated with flow diverters. Demographics, clinical presentation, radiographic characteristics, procedural complications, and outcomes were assessed. RESULTS: A total of 144 patients harboring 147 AComm aneurysms were treated between January 2012 and December 2021. Seventy-four were women (51.4%) and median age was 60 (IQR 50-67) years. All were unruptured AComm aneurysms. Half of the cohort had similar anterior cerebral artery sizes (51.4%). The most common morphology was saccular (94.6%), with a branch involvement in 32.7% of cases. Median vessel diameter was 2.4 mm, and the Pipeline Flex was the most prevalent device (32.7%). Median follow-up time was 17 months, with complete occlusion in 86.4% at the last follow-up. Functional independence (modified Rankin Scale score 0-2) was reported in 95.1%. Intraprocedural complications occurred in 5.6%, and postoperative complications were noted in 9.7% of cases. Combined major complication and mortality rate was 2.1%. CONCLUSIONS: Our study suggests that flow diverters are a useful treatment for AComm aneurysms. Mid-term results indicated favorable aneurysm occlusion with a good safety profile. Additional prospective studies with longer follow-up periods and independent adjudication are warranted to better assess these results.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Femenino , Persona de Mediana Edad , Masculino , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Estudios Retrospectivos , Estudios Prospectivos , Embolización Terapéutica/métodos , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Stents
3.
J Neurointerv Surg ; 15(4): 387-392, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35396333

RESUMEN

BACKGROUND: In contrast to conventional CT perfusion (CTP) imaging, flat panel detector CT perfusion (FD-CTP) imaging can be acquired directly in the angiosuite. OBJECTIVE: To evaluate time-resolved whole brain FD-CTP imaging and assess clinically important qualitative and quantitative perfusion parameters in correlation with previously acquired conventional CTP using the new RAPID for ANGIO software. METHODS: We included patients with internal carotid artery occlusions and M1 or M2 occlusions from six centers. All patients underwent mechanical thrombectomy (MT) with preinterventional conventional CTP and FD-CTP imaging. Quantitative performance was determined by comparing volumes of infarct core, penumbral tissue, and mismatch. Eligibility for MT according to the perfusion imaging criteria of DEFUSE 3 was determined for each case from both conventional CTP and FD-CTP imaging. RESULTS: A total of 20 patients were included in the final analysis. Conventional relative cerebral blood flow (rCBF) <30% and FD-CTP rCBF <45% showed good correlation (R2=0.84). Comparisons of conventional CTP Tmax >6 s versus FD-CTP Tmax >6 s and CTP mismatch versus FD-CTP mismatch showed more variability (R2=0.57, and R2=0.33, respectively). Based on FD-CTP, 16/20 (80%) patients met the inclusion criteria for MT according to the DEFUSE 3 perfusion criteria, in contrast to 18/20 (90%) patients based on conventional CTP. The vessel occlusion could be correctly extrapolated from the hypoperfusion in 18/20 cases (90%). CONCLUSIONS: In our multicenter study, time-resolved whole brain FD-CTP was technically feasible, and qualitative and quantitative perfusion results correlated with those obtained with conventional CTP.


Asunto(s)
Isquemia Encefálica , Accidente Cerebrovascular , Humanos , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Accidente Cerebrovascular/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Imagen de Perfusión/métodos , Trombectomía/métodos
4.
Eur J Neurol ; 29(11): 3273-3287, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35818781

RESUMEN

BACKGROUND AND PURPOSE: Previous studies suggest that mechanisms and outcomes in patients with COVID-19-associated stroke differ from those in patients with non-COVID-19-associated strokes, but there is limited comparative evidence focusing on these populations. The aim of this study, therefore, was to determine if a significant association exists between COVID-19 status with revascularization and functional outcomes following thrombectomy for large vessel occlusion (LVO), after adjustment for potential confounding factors. METHODS: A cross-sectional, international multicenter retrospective study was conducted in consecutively admitted COVID-19 patients with concomitant acute LVO, compared to a control group without COVID-19. Data collected included age, gender, comorbidities, clinical characteristics, details of the involved vessels, procedural technique, and various outcomes. A multivariable-adjusted analysis was conducted. RESULTS: In this cohort of 697 patients with acute LVO, 302 had COVID-19 while 395 patients did not. There was a significant difference (p < 0.001) in the mean age (in years) and gender of patients, with younger patients and more males in the COVID-19 group. In terms of favorable revascularization (modified Thrombolysis in Cerebral Infarction [mTICI] grade 3), COVID-19 was associated with lower odds of complete revascularization (odds ratio 0.33, 95% confidence interval [CI] 0.23-0.48; p < 0.001), which persisted on multivariable modeling with adjustment for other predictors (adjusted odds ratio 0.30, 95% CI 0.12-0.77; p = 0.012). Moreover, endovascular complications, in-hospital mortality, and length of hospital stay were significantly higher among COVID-19 patients (p < 0.001). CONCLUSION: COVID-19 was an independent predictor of incomplete revascularization and poor functional outcome in patients with stroke due to LVO. Furthermore, COVID-19 patients with LVO were more often younger and had higher morbidity/mortality rates.


Asunto(s)
Isquemia Encefálica , COVID-19 , Procedimientos Endovasculares , Accidente Cerebrovascular , COVID-19/complicaciones , Estudios Transversales , Procedimientos Endovasculares/métodos , Humanos , Masculino , Estudios Retrospectivos , Accidente Cerebrovascular/cirugía , Trombectomía/métodos , Resultado del Tratamiento
5.
Neurosurgery ; 91(4): 547-554, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35830269

RESUMEN

BACKGROUND: Treatment of small-caliber vessel lesions using flow diverters remains challenging because of vasculature's narrow luminal diameter and tortuosity. This in turn makes navigation and delivery of conventional devices with standard microcatheters more difficult. The Silk Vista Baby (SVB, Balt) flow diversion device was designed for ease of use in vessels with a smaller diameter, distal lesions, and 0.017 ″ microcatheter delivery systems. OBJECTIVE: To report the outcomes of the SVB device on the treatment of posterior inferior cerebellar artery (PICA) aneurysms. METHODS: Databases from different centers were retrospectively reviewed for PICA aneurysms treated with SVB. Demographic information, clinical presentation, radiographic characteristics, procedural complications, and immediate postprocedure outcomes were obtained. RESULTS: Fourteen patients harboring 15 true PICA aneurysms were treated between January 2019 and June 2021. Nine were female (n = 9/14; 64.2%), and the mean age was 51 ± 14.9 years. Most patients had previously ruptured aneurysms, treated by another endovascular technique. Six aneurysms were located distally (n = 6/15; 40%). The mean neck size was 3 mm (SD 1.35, range 2.5-5 mm), whereas the mean PICA diameter was 1.6 mm (SD 0.26, range 1.5-1.7 mm). The mean length of follow-up was 6 months (SD 8.28, range 4.5-16 months). Treatment-related adverse events included 1 case of transient hypoesthesia. Two additional events were reported, but adjudicated as unrelated to the procedure. Complete occlusion, measured as Raymond-Roy class I, was achieved in all cases. CONCLUSION: The SVB device was safely and effectively used in the treatment of PICA aneurysms. The smaller delivery system profile reduces the risk of procedure complications and creates new treatment options for distal lesions.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Adulto , Anciano , Cerebelo/irrigación sanguínea , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/etiología , Aneurisma Intracraneal/cirugía , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Seda , Resultado del Tratamiento , Arteria Vertebral
6.
Neurosurgery ; 90(6): 725-733, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35238817

RESUMEN

BACKGROUND: The mechanisms and outcomes in coronavirus disease (COVID-19)-associated stroke are unique from those of non-COVID-19 stroke. OBJECTIVE: To describe the efficacy and outcomes of acute revascularization of large vessel occlusion (LVO) in the setting of COVID-19 in an international cohort. METHODS: We conducted an international multicenter retrospective study of consecutively admitted patients with COVID-19 with concomitant acute LVO across 50 comprehensive stroke centers. Our control group constituted historical controls of patients presenting with LVO and receiving a mechanical thrombectomy between January 2018 and December 2020. RESULTS: The total cohort was 575 patients with acute LVO; 194 patients had COVID-19 while 381 patients did not. Patients in the COVID-19 group were younger (62.5 vs 71.2; P < .001) and lacked vascular risk factors (49, 25.3% vs 54, 14.2%; P = .001). Modified thrombolysis in cerebral infarction 3 revascularization was less common in the COVID-19 group (74, 39.2% vs 252, 67.2%; P < .001). Poor functional outcome at discharge (defined as modified Ranklin Scale 3-6) was more common in the COVID-19 group (150, 79.8% vs 132, 66.7%; P = .004). COVID-19 was independently associated with a lower likelihood of achieving modified thrombolysis in cerebral infarction 3 (odds ratio [OR]: 0.4, 95% CI: 0.2-0.7; P < .001) and unfavorable outcomes (OR: 2.5, 95% CI: 1.4-4.5; P = .002). CONCLUSION: COVID-19 was an independent predictor of incomplete revascularization and poor outcomes in patients with stroke due to LVO. Patients with COVID-19 with LVO were younger, had fewer cerebrovascular risk factors, and suffered from higher morbidity/mortality rates.


Asunto(s)
Isquemia Encefálica , COVID-19 , Accidente Cerebrovascular , Isquemia Encefálica/etiología , Infarto Cerebral/etiología , Humanos , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Trombectomía/efectos adversos , Resultado del Tratamiento
7.
J Neurointerv Surg ; 14(10): 1014-1017, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34716215

RESUMEN

BACKGROUND: Flow diverters have revolutionized the treatment of intracranial aneurysms. Nevertheless, some aneurysms fail to occlude with flow diversion. The Prospective Study on Embolization of Intracranial Aneurysms with the Pipeline Device (PREMIER) was a prospective, multicenter and single-arm trial of small and medium wide-necked unruptured aneurysms. In the current study, we evaluate the predictors of treatment failure in the PREMIER cohort. METHODS: We analyzed PREMIER patients who had incomplete occlusion (Raymond-Roy >1) at 1 year angiographic follow-up and compared them with those who achieved Raymond-Roy 1, aiming to identify predictors of treatment failure. RESULTS: 25 aneurysms demonstrated incomplete occlusion at 1 year. There was a median reduction of 0.9 mm (IQR 0.41-2.43) in maximum diameter between pre-procedure and 1 year measurements, with no aneurysmal hemorrhage. Patients with incomplete occlusion were significantly older than those with complete occlusion (p=0.011). Smoking (p=0.045) and C6 segment location (p=0.005) were significantly associated with complete occlusion, while location at V4 (p=0.01) and C7 (p=0.007) and involvement of a side branch (p<0.001) were significantly associated with incomplete occlusion. In multivariable logistic regression, significant predictors of incomplete occlusion were non-smoker status (adjusted OR 4.49, 95% CI 1.11 to 18.09; p=0.03) and side branch involvement (adjusted OR 11.68, 95% CI 3.84 to 35.50; p<0.0001), while C6 location had reduced odds of incomplete occlusion (adjusted OR 0.29, 95% CI 0.10 to 0.84; p=0.02). CONCLUSIONS: The results of our study are consistent with previous retrospective series and warrant consideration for technique adaptations to achieve higher occlusion rates. Further follow-up is needed to assess progression of aneurysm occlusion and clinical behavior in these cases.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Embolización Terapéutica/métodos , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento
8.
Diagnostics (Basel) ; 11(9)2021 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-34573963

RESUMEN

Final lesion volume (FLV) is a surrogate outcome measure in anterior circulation stroke (ACS). In posterior circulation stroke (PCS), this relation is plausibly understudied due to a lack of methods that automatically quantify FLV. The applicability of deep learning approaches to PCS is limited due to its lower incidence compared to ACS. We evaluated strategies to develop a convolutional neural network (CNN) for PCS lesion segmentation by using image data from both ACS and PCS patients. We included follow-up non-contrast computed tomography scans of 1018 patients with ACS and 107 patients with PCS. To assess whether an ACS lesion segmentation generalizes to PCS, a CNN was trained on ACS data (ACS-CNN). Second, to evaluate the performance of only including PCS patients, a CNN was trained on PCS data. Third, to evaluate the performance when combining the datasets, a CNN was trained on both datasets. Finally, to evaluate the performance of transfer learning, the ACS-CNN was fine-tuned using PCS patients. The transfer learning strategy outperformed the other strategies in volume agreement with an intra-class correlation of 0.88 (95% CI: 0.83-0.92) vs. 0.55 to 0.83 and a lesion detection rate of 87% vs. 41-77 for the other strategies. Hence, transfer learning improved the FLV quantification and detection rate of PCS lesions compared to the other strategies.

9.
J Neurol Surg B Skull Base ; 82(Suppl 3): e278-e284, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34306950

RESUMEN

Objective Endovascular treatment of carotid-cavernous fistulas (CCFs) has been consistently shown to give excellent results and is currently the mainstay of treatment of these complex vascular pathologies. Onyx is currently the most widely used agent, but there has been concern over high rates of cranial nerve (CN) deficits seen in patients with CCF treated with Onyx and paucity of data on long-term outcomes. Methods This is a retrospective analysis of patients who underwent transvenous Onyx embolization between 2011 and 2018. The data collected included demographics, comorbidities, presenting symptoms, CCF morphology, degree of obliteration, procedure-related complications, clinical outcomes, and follow-up. Results A total of seven patients (five females) were included. The median age was 66 years (range: 15-79 years). Median duration of symptoms before treatment was 4 weeks (range: 1-24 weeks). There were three direct and four indirect CCFs. Barrow classification is as follows: A-3; B-3; C-0; and D-1. Immediate complete occlusion was achieved in all cases. There was also one case of immediate postoperative change in CN function (new partial CN VI deficit) that resolved completely at 1-month follow-up. The mean length of stay was 3 days (±2). The preoperative extraocular movement CN deficits had the following outcomes: three resolved; two improved; and one persisted. Proptosis, chemosis, conjunctival injection, and tinnitus were resolved in all patients. The median follow-up was 34 months (range: 10-91 months). Conclusion Transvenous Onyx embolization is a safe and effective treatment of CCFs when technical aspects to reduce complications are performed diligently. Our technique demonstrates safety of the Onyx as a stand-alone embolization for the treatment of CCF.

10.
Interv Neuroradiol ; 27(6): 774-780, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33752477

RESUMEN

PURPOSE: Flow-diverters have revolutionized the endovascular treatment of intracranial aneurysms, offering a durable solution to aneurysms with high recurrence rates after conventional stent-assisted coiling. Events that occur after treatment with flow-diversion, such as in-stent stenosis (ISS) are not well understood and require further assessment. After assessing an animal model with Optical Coherence Tomography (OCT), we propose a concept that could explain the mechanism causing reversible ISS after treatment of intracranial aneurysms with flow-diverters. METHODS: Six Pipeline Flex embolization devices (PED-Flex), six PED with Shield technology (PED-Shield), and four Solitaire AB devices were implanted in the carotid arteries (two stents per vessel) of four pigs. Intravascular optical coherence tomography (OCT) and digital subtraction angiography (DSA) images obtained on day 21 were compared to histological specimens. RESULTS: A case of ISS in a PED-Flex device was assessed with OCT imaging. Neointima with asymmetrical topography completely covering the PED struts was observed. Histological preparations of the stenotic area demonstrated thrombus on the surface of device struts, covered by neointima. CONCLUSION: This study provides a plausible concept for reversible ISS in flow-diverters. Based on an observation of a previous experiment, we propose that similar cases of ISS are related to thrombus presence underneath endothelization, but further experiments focused on this phenomenon are needed. Optical Coherence Tomography will be useful tool when available for clinical use.


Asunto(s)
Aneurisma Intracraneal , Trombosis , Animales , Constricción Patológica , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Stents , Porcinos , Tomografía de Coherencia Óptica
13.
World Neurosurg ; 143: 325-331, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32777396

RESUMEN

BACKGROUND: Intravascular ultrasound (IVUS) provides endoluminal views and cross-sectional images of carotid arteries but lacks overview of vascular territory provided by angiography. Co-registration of IVUS with angiographic images may provide the potential to navigate both imaging modalities in a synchronous manner. The objective of this study is to evaluate the feasibility and accuracy of co-registering both imaging modalities in the carotid vasculature of the neck. METHODS: Fourteen patients with 15 cervical carotid artery lesions underwent angiography and subsequent treatment. In each case, an IVUS catheter was advanced to the target lesion and a reference angiography sequence was acquired. This was followed by an electrocardiography-triggered fluoroscopy sequence that was initiated upon IVUS catheter pullback. IVUS data collected during pullback were registered with fluoroscopy and evaluated for error and clinical usability. RESULTS: A total of 32 landmarks were identified that demonstrated reasonable agreement during IVUS-angiography co-registration. There was a mean registration error distance of 3.36 mm (SD 2.82 mm) between targets. The longitudinal extent and severity of the disease through the target segment could be easily evaluated after co-registration. CONCLUSION: Semiautomatic tracking and co-registration of angiography and IVUS is a new technology and has the potential to increase the use of IVUS in carotid disease and to proivde the opportunity to optimize procedural outcomes.


Asunto(s)
Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Ultrasonografía Intervencional/métodos , Adulto , Anciano , Anciano de 80 o más Años , Puntos Anatómicos de Referencia , Angiografía/métodos , Automatización , Cateterismo , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Reproducibilidad de los Resultados
14.
Nat Commun ; 11(1): 3851, 2020 07 31.
Artículo en Inglés | MEDLINE | ID: mdl-32737314

RESUMEN

Intravascular imaging has emerged as a valuable tool for the treatment of coronary and peripheral artery disease; however, no solution is available for safe and reliable use in the tortuous vascular anatomy of the brain. Endovascular treatment of stroke is delivered under image guidance with insufficient resolution to adequately assess underlying arterial pathology and therapeutic devices. High-resolution imaging, enabling surgeons to visualize cerebral arteries' microstructure and micron-level features of neurovascular devices, would have a profound impact in the research, diagnosis, and treatment of cerebrovascular diseases. Here, we present a neurovascular high-frequency optical coherence tomography (HF-OCT) system, including an imaging console and an endoscopic probe designed to rapidly acquire volumetric microscopy data at a resolution approaching 10 microns in tortuous cerebrovascular anatomies. Using a combination of in vitro, ex vivo, and in vivo models, the feasibility of HF-OCT for cerebrovascular imaging was demonstrated.


Asunto(s)
Arteria Basilar/diagnóstico por imagen , Arterias Carótidas/diagnóstico por imagen , Arterias Cerebrales/diagnóstico por imagen , Microscopía/métodos , Tomografía de Coherencia Óptica/métodos , Arteria Vertebral/diagnóstico por imagen , Angiografía/instrumentación , Angiografía/métodos , Animales , Cadáver , Circulación Cerebrovascular/fisiología , Humanos , Microscopía/instrumentación , Porcinos , Tomografía de Coherencia Óptica/instrumentación
15.
World Neurosurg ; 136: 178-183, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31954902

RESUMEN

OBJECTIVE: Jugular foramen paragangliomas are highly vascular tumors known to have significant venous hemorrhage during resection even after conventional transarterial embolization. The authors report a novel technique to the endovascular embolization of jugular foramen paragangliomas using a combined transarterial and transvenous access for better intraoperative control of blood loss and visualization. METHODS: This is a retrospective data collection of 2 patients diagnosed with jugular foramen paragangliomas with novel embolization technique and surgical resection. RESULTS: Two patients underwent embolization of jugular foramen paragangliomas through combined transarterial and transvenous routes using 2 double-lumen balloon microcatheters. In both cases, single arterial vessel embolization was performed through the occipital artery in Case 1 and the tympanic branch of the ascending pharyngeal artery in Case 2. Simultaneously, balloon microcatheter occlusion in the sigmoid sinus and single venous outflow vessel embolization was performed. Near-complete occlusion was established, with angiographic disappearance of tumor blush. Surgical resection was performed in both cases. Estimated blood loss BL was 600 mL in Case 1 and 200 mL in Case 2. No blood transfusions were required, intraoperatively or postoperatively. There were no cranial nerve deficits post embolization. One patient had a persistent House Brackman 2 facial nerve palsy after resection. CONCLUSIONS: The initial experience with simultaneous transvenous and transarterial paraganglioma embolization demonstrated the safety of the technique and superior embolic agent penetration. This was supported by our observations during embolization and intraoperatively during tumor resection. Additional patients need to be treated with this technique for better assessment of long-term efficacy and incidence of embolization-related cranial neuropathies.


Asunto(s)
Embolización Terapéutica/métodos , Paraganglioma/terapia , Neoplasias de la Base del Cráneo/terapia , Humanos , Foramina Yugular , Persona de Mediana Edad , Paraganglioma/diagnóstico por imagen , Neoplasias de la Base del Cráneo/diagnóstico por imagen
16.
J Stroke Cerebrovasc Dis ; 28(9): 2574-2579, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31239220

RESUMEN

GOALS: While mechanical thrombectomy (MT) has been shown to be effective in the treatment of acute large vessel occlusions, adjunctive measures, such as balloon guide catheters (BGC) and aspiration techniques, are utilized heterogeneously. Clarifying the effects of aspiration applied to the anterior cerebral circulation with proximal flow arrest can shed light on embolic protection during MT. MATERIALS AND METHODS: Manual and pump aspiration were applied through a BGC in a synthetic cerebrovascular model with a 60 ml syringe and a Penumbra pump, respectively. Flow direction was observed during the procedure with fluorescent particles and ultraviolet light. Flow rates were monitored at the simulated internal carotid artery and middle cerebral artery (MCA). FINDINGS: Both aspiration methods produced retrograde flow in all the modeled cerebrovascular segments. In the syringe aspiration methods, an interval phase occurred during the experimental trial in which suction forces paused and MCA flow became anterograde through posterior communication artery collateral circulation. CONCLUSION: Flow patterns vary with different methods of aspiration. With proximal flow arrest, continuous aspiration methods induce constant retrograde flow in all vessels, whereas manual aspiration demonstrates various flow changes, including periods of anterograde flow during the procedure, which may be less effective at distal re-embolization prevention.


Asunto(s)
Arteria Carótida Interna/fisiopatología , Circulación Cerebrovascular , Trastornos Cerebrovasculares/terapia , Arteria Cerebral Media/fisiopatología , Trombectomía/métodos , Velocidad del Flujo Sanguíneo , Trastornos Cerebrovasculares/fisiopatología , Humanos , Embolia Intracraneal/etiología , Embolia Intracraneal/fisiopatología , Embolia Intracraneal/prevención & control , Modelos Anatómicos , Factores de Riesgo , Succión , Jeringas , Trombectomía/efectos adversos , Trombectomía/instrumentación , Factores de Tiempo , Dispositivos de Acceso Vascular
17.
JAMA Neurol ; 76(2): 194-202, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30615038

RESUMEN

Importance: The positive treatment effect of endovascular therapy (EVT) is assumed to be caused by the preservation of brain tissue. It remains unclear to what extent the treatment-related reduction in follow-up infarct volume (FIV) explains the improved functional outcome after EVT in patients with acute ischemic stroke. Objective: To study whether FIV mediates the relationship between EVT and functional outcome in patients with acute ischemic stroke. Design, Setting, and Participants: Patient data from 7 randomized multicenter trials were pooled. These trials were conducted between December 2010 and April 2015 and included 1764 patients randomly assigned to receive either EVT or standard care (control). Follow-up infarct volume was assessed on computed tomography or magnetic resonance imaging after stroke onset. Mediation analysis was performed to examine the potential causal chain in which FIV may mediate the relationship between EVT and functional outcome. A total of 1690 patients met the inclusion criteria. Twenty-five additional patients were excluded, resulting in a total of 1665 patients, including 821 (49.3%) in the EVT group and 844 (50.7%) in the control group. Data were analyzed from January to June 2017. Main Outcome and Measure: The 90-day functional outcome via the modified Rankin Scale (mRS). Results: Among 1665 patients, the median (interquartile range [IQR]) age was 68 (57-76) years, and 781 (46.9%) were female. The median (IQR) time to FIV measurement was 30 (24-237) hours. The median (IQR) FIV was 41 (14-120) mL. Patients in the EVT group had significantly smaller FIVs compared with patients in the control group (median [IQR] FIV, 33 [11-99] vs 51 [18-134] mL; P = .007) and lower mRS scores at 90 days (median [IQR] score, 3 [1-4] vs 4 [2-5]). Follow-up infarct volume was a predictor of functional outcome (adjusted common odds ratio, 0.46; 95% CI, 0.39-0.54; P < .001). Follow-up infarct volume partially mediated the relationship between treatment type with mRS score, as EVT was still significantly associated with functional outcome after adjustment for FIV (adjusted common odds ratio, 2.22; 95% CI, 1.52-3.21; P < .001). Treatment-reduced FIV explained 12% (95% CI, 1-19) of the relationship between EVT and functional outcome. Conclusions and Relevance: In this analysis, follow-up infarct volume predicted functional outcome; however, a reduced infarct volume after treatment with EVT only explained 12% of the treatment benefit. Follow-up infarct volume as measured on computed tomography and magnetic resonance imaging is not a valid proxy for estimating treatment effect in phase II and III trials of acute ischemic stroke.


Asunto(s)
Isquemia Encefálica/patología , Isquemia Encefálica/terapia , Procedimientos Endovasculares/estadística & datos numéricos , Evaluación de Resultado en la Atención de Salud/estadística & datos numéricos , Accidente Cerebrovascular/patología , Accidente Cerebrovascular/terapia , Anciano , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/fisiopatología , Infarto Cerebral/diagnóstico por imagen , Infarto Cerebral/patología , Infarto Cerebral/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto/estadística & datos numéricos , Ensayos Clínicos Controlados Aleatorios como Asunto/estadística & datos numéricos , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/fisiopatología
18.
Neurosurg Focus ; 46(Suppl_1): V3, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30611185

RESUMEN

External carotid artery (ECA) to internal carotid artery (ICA) bypass is a well-established procedure for the treatment of chronic ischemic diseases of the carotid artery. Rarely de novo aneurysms can develop at the site of anastomosis. The treatment of these aneurysms can be very challenging due to various factors, including the presence of graft, previous craniotomy, atherosclerotic vessels, and lack of direct access. In this video the authors report and discuss the management of a right middle cerebral artery (MCA) wide-necked de novo aneurysm by stent-assisted coiling through a retrograde trans-posterior communicating artery access.The video can be found here: https://youtu.be/MBKolPvOErU.


Asunto(s)
Embolización Terapéutica/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Stents Metálicos Autoexpandibles , Embolización Terapéutica/instrumentación , Humanos , Masculino , Persona de Mediana Edad
19.
Neurosurgery ; 84(6): E402-E409, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30239959

RESUMEN

BACKGROUND: The Pipeline Flex (PED Flex; Medtronic, Dublin, Ireland) was designed to facilitate deployment and navigation compared to its previous iteration to reduce the rate of technical events and complications. OBJECTIVE: To assess the neurological morbidity and mortality rates of the PED Flex at 30 d. METHODS: Information from 9 neurovascular centers was retrospectively obtained between July 2014 and March 2016. Data included patient/aneurysm characteristics, periprocedural events, clinical, and angiographic outcomes. Multivariate logistic regression was performed to determine predictors of unfavorable clinical outcome (modified Rankin Scale [mRS] > 2). RESULTS: A total of 205 patients harboring 223 aneurysms were analyzed. The 30-d neurological morbidity and mortality rates were 1.9% (4/205) and 0.5% (1/205), respectively. The rate of intraprocedural events without neurological morbidity was 6.8% (14/205), consisting of intraprocedural ischemic events in 9 patients (4.5%) and hemorrhage in 5 (2.4%). Other technical events included difficulty capturing the delivery wire in 1 case (0.5%) and device migration after deployment in another case (0.5%). Favorable clinical outcome (mRS 0-2) was achieved in 186 patients (94.4%) at discharge and in 140 patients (94.5%) at 30 d. We did not find predictors of clinical outcomes on multivariate analysis. CONCLUSION: The 30-d rates of neurological morbidity and mortality in this multicenter cohort using the PED Flex for the treatment of intracranial aneurysms were low, 1.9% (4/205) and 0.5% (1/205), respectively. In addition, technical events related to device deployment were also low, most likely due to the latest modifications in the delivery system.


Asunto(s)
Aneurisma Intracraneal/cirugía , Adulto , Anciano , Angiografía , Femenino , Humanos , Aneurisma Intracraneal/mortalidad , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Alta del Paciente , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
20.
Interv Neuroradiol ; 25(2): 150-156, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30396311

RESUMEN

BACKGROUND: The new generation of flow diverters includes a surface modification with a synthetic biocompatible polymer, which makes the device more biocompatible and less thrombogenic. Optical coherence tomography (OCT) can be used to visualize perforators, stent wall apposition, and intra-stent thrombus. Unfortunately real world application of this technology has been limited because of the limited navigability of these devices in the intracranial vessels. In this report, we share our experience of using 3D-printed neurovascular anatomy models to simulate and test the navigability of a commercially available OCT system and to show the application of this device in a patient treated with the new generation of surface modified flow diverters. MATERIAL AND METHODS: Navigability of OCT catheters was tested in vitro using four different 3D-printed silicone replicas of the intracranial anterior circulation, after the implantation of surface modified devices. Intermediate catheters were used in different tortuous anatomies and positions. After this assessment, we describe the OCT image analysis of a Pipeline Shield for treating an unruptured posterior communicating artery (PCOM) aneurysm. RESULTS: Use of intermediate catheters in the 3D-printed replicas was associated with better navigation of the OCT catheters in favorable anatomies but did not help as much in unfavorable anatomies. OCT image analysis of a PCOM aneurysm treated with Pipeline Embolization Device Shield demonstrated areas of unsatisfactory apposition with no thrombus formation. CONCLUSIONS: OCT improves the understanding of the flow diversion technology. The development of less thrombogenic devices, like the Pipeline Flex with Shield Technology, reinforces the need for intraluminal imaging for neurovascular application.


Asunto(s)
Circulación Cerebrovascular , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Modelos Anatómicos , Impresión Tridimensional , Stents , Tomografía de Coherencia Óptica , Angiografía de Substracción Digital , Materiales Biocompatibles , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...