Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur Rev Med Pharmacol Sci ; 24(21): 11445-11454, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33215472

RESUMEN

In Italy, SARS-CoV-2 outbreak registered a high transmission and disease rates. During the acute phase, oncologists provided to re-organize services and prioritize treatments, in order to limit viral spread and to protect cancer patients. The progressive reduction of the number of infections has prompted Italian government to gradually loosen the national confinement measures and to start the "Second phase" of measures to contain the pandemic. The issue on how to organize cancer care during this post-acute SARS-CoV-2 phase appears crucial and a reassessment of healthcare services is needed requiring new models of care for oncological patients. In order to address major challenges in cancer setting during post-acute SARS-CoV-2 phase, this work offers multidimensional solutions aimed to provide a new way to take care of cancer patients.


Asunto(s)
Control de Enfermedades Transmisibles/organización & administración , Infecciones por Coronavirus/prevención & control , Oncología Médica/organización & administración , Modelos Organizacionales , Neoplasias/terapia , Pandemias/prevención & control , Neumonía Viral/prevención & control , Betacoronavirus/patogenicidad , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico/normas , Control de Enfermedades Transmisibles/normas , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/transmisión , Servicios de Atención a Domicilio Provisto por Hospital/organización & administración , Servicios de Atención a Domicilio Provisto por Hospital/normas , Humanos , Italia/epidemiología , Oncología Médica/normas , Neoplasias/diagnóstico , Neumonía Viral/diagnóstico , Neumonía Viral/epidemiología , Neumonía Viral/transmisión , SARS-CoV-2 , Triaje/organización & administración , Triaje/normas
2.
Sci Rep ; 9(1): 18732, 2019 12 10.
Artículo en Inglés | MEDLINE | ID: mdl-31822796

RESUMEN

The complex inhomogeneous architecture of the human meniscal tissue at the micro and nano scale in the absence of artefacts introduced by sample treatments has not yet been fully revealed. The knowledge of the internal structure organization is essential to understand the mechanical functionality of the meniscus and its relationship with the tissue's complex structure. In this work, we investigated human meniscal tissue structure using up-to-date non-invasive imaging techniques, based on multiphoton fluorescence and quantitative second harmonic generation microscopy complemented with Environmental Scanning Electron Microscopy measurements. Observations on 50 meniscal samples extracted from 6 human menisci (3 lateral and 3 medial) revealed fundamental features of structural morphology and allowed us to quantitatively describe the 3D organisation of elastin and collagen fibres bundles. 3D regular waves of collagen bundles are arranged in "honeycomb-like" cells that are comprised of pores surrounded by the collagen and elastin network at the micro-scale. This type of arrangement propagates from macro to the nanoscale.


Asunto(s)
Meniscos Tibiales/anatomía & histología , Meniscos Tibiales/patología , Microscopía/métodos , Fenómenos Biofísicos/fisiología , Colágeno/química , Elastina , Humanos , Imagenología Tridimensional/métodos , Meniscos Tibiales/diagnóstico por imagen , Menisco/diagnóstico por imagen , Menisco/patología , Microscopía Electrónica de Rastreo/métodos
3.
Biochim Biophys Acta Gen Subj ; 1863(5): 893-902, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30817979

RESUMEN

BACKGROUND: Colorectal adenocarcinoma cells (Caco-2) are a widely used model of intestinal barrier to study cancer development, toxicological assessments, absorption and metabolism in food science or drug discovery. Caco-2 spontaneously differentiate into a monolayer expressing several specific characteristics, typically showed by mature enterocytes. For in vitro experiments, it is crucial to identify non-invasive and non-destructive techniques able to evaluate the integrity and differentiation of the cells monolayer. Thus, we aimed to assess these properties by analyzing electrical impedance measurements. METHODS: Caco-2 cells were differentiated for 21 days. The monolayer integrity and differentiation were primarily evaluated by means of morphological, biochemical and molecular data. Impedance measurements in a range of frequencies from 400 Hz to 50 kHz were performed using a dedicated set up, including customized Aerosol Jet Printed carbon-based sensors. RESULTS: The trends of RI observed at three different frequencies were able to describe cell growth and differentiation. In order to evaluate which frequencies better correlate with cell differentiation, Principal Component Analysis have been employed and the concordance analysis between RI magnitude and morphological, biochemical and molecular data, highlighted 40 kHz as the optimal frequency to assess Caco-2 cells differentiation process. CONCLUSION: We demonstrated the feasibility and reliability of applying impedance-based measurements not only to provide information about the monolayer status, but also for cell differentiation monitoring. GENERAL SIGNIFICANCE: This study underlined the possibility to use a dedicated sensor to assess the integrity and differentiation of Caco-2 monolayer, as a reliable non-destructive alternative to conventional approaches.


Asunto(s)
Diferenciación Celular , Impedancia Eléctrica , Técnicas Electroquímicas , Impresión Tridimensional , Células CACO-2 , Proliferación Celular , Electrodos , Humanos
4.
J Biol Regul Homeost Agents ; 32(6 Suppl. 1): 35-40, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30644279

RESUMEN

The knee is the largest and most complex joint in the human body. Traumatic events, such as anterior cruciate ligament (ACL) tear, can lead to an alteration of joint tissues homeostasis. Literature reports an evident correlation between abnormal joint biomechanics and the status of articular tissues. These alterations, due to a sub-optimal ACL reconstruction, may result in an increasing risk of developing degenerative pathologies, such as osteoarthritis. Thus, the identification of the optimal surgical technique is a highly demanding issue in ACL reconstruction. The aim of this study was to analyze the correlation between joint cartilage conditions and knee biomechanics in ACL reconstructions, by integrating MRI T2 mapping investigations, radiostereophotogrammetry-based gait analysis and subject-specific musculoskeletal modelling.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior/diagnóstico por imagen , Reconstrucción del Ligamento Cruzado Anterior , Cartílago Articular/diagnóstico por imagen , Fenómenos Biomecánicos , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética
5.
J Mech Behav Biomed Mater ; 72: 200-208, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28500999

RESUMEN

In joint arthroplasty one of the main issues related to the failure of prosthetic implants is due to the wear of the ultra-high molecular weight polyethylene (UHMWPE) component. Surface treatments and coatings have been recognized as enhancing methods, able to improve the tribological properties of the implants. Therefore, the main objective of this work was to investigate the possibility to fabricate yttria-stabilized zirconia (YSZ) coatings on a metal (AISI 316-L) substrate by means of Pulsed Electron Deposition, in order to improve the tribological behavior of the polymer-metal coupling, by reducing the initial wear of the UHMWPE component. In order to optimize the coating characteristics, the effects of working gas pressure on both its morphological and tribological properties were analyzed. Morphological characterization of the films was evaluated by Atomic Force Microscopy (AFM). Coating wettability was also estimated by contact angle (CA) measurement. Tribological performance (coupling friction and wear of UHMWPE) was evaluated by using a ball-on-disc tribometer during highly-stressing tests in dry and lubricated (i.e. NaCl and serum) conditions; friction and wear were specifically evaluated at the initial sliding distances - to highlight the main effect of coating morphology - and after 100m - where the influence of the intrinsic materials properties prevails. AFM analysis highlighted that the working pressure heavily affected the morphological characteristics of the realized films. The wettability of the coating at the highest and lowest deposition pressures (CA ~ 60°, closed to substrate value) decreased for intermediate pressures, reaching a maximum CA of ~ 90°. Regarding tribological tests, a strong correlation was found in the initial steps between friction coefficient and wettability, which decreased as the distance increased. Concerning UHMWPE wear associated to coated counterpart, at 100m a reduction rate of about 7% in dry, 12% in NaCl and 5% in presence of serum was obtained compared to the uncoated counterpart. Differently from what highlighted for friction, no correlation was found between wear rate and morphological parameters. These findings, in agreement with literature, underlined the effect of the deposition pressure on the morphological properties, but suggested that physical characteristics are influenced too. Further research on the deposition process will be required in order to improve the tribological performance of the coating at long distances, addressing - above all - orthopedic applications.


Asunto(s)
Ensayo de Materiales , Prótesis e Implantes , Circonio/análisis , Fricción , Humanos , Gases em Plasma , Polietilenos , Presión , Propiedades de Superficie , Humectabilidad
6.
Proc Inst Mech Eng H ; 221(7): 725-37, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18019460

RESUMEN

In this paper a new navigation system, KIN-Nav, developed for research and used during 80 anterior cruciate ligament (ACL) reconstructions is described. KIN-Nav is a user-friendly navigation system for flexible intraoperative acquisitions of anatomical and kinematic data, suitable for validation of biomechanical hypotheses. It performs real-time quantitative evaluation of antero-posterior, internal-external, and varus-valgus knee laxity at any degree of flexion and provides a new interface for this task, suitable also for comparison of pre-operative and post-operative knee laxity and surgical documentation. In this paper the concept and features of KIN-Nav, which represents a new approach to navigation and allows the investigation of new quantitative measurements in ACL reconstruction, are described. Two clinical studies are reported, as examples of clinical potentiality and correct use of this methodology. In this paper a preliminary analysis of KIN-Nav's reliability and clinical efficacy, performed during blinded repeated measures by three independent examiners, is also given. This analysis is the first assessment of the potential of navigation systems for evaluating knee kinematics.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/cirugía , Procedimientos de Cirugía Plástica/instrumentación , Robótica/instrumentación , Cirugía Asistida por Computador/instrumentación , Interfaz Usuario-Computador , Gráficos por Computador , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Modelos Biológicos , Procedimientos de Cirugía Plástica/métodos , Robótica/métodos , Cirugía Asistida por Computador/métodos , Evaluación de la Tecnología Biomédica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...