Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Ann Ig ; 35(6): 631-640, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37724578

RESUMEN

Background: Legionnaires' disease is caused by inhalation or aspiration of small water droplets contaminated with Legionella, commonly found in natural and man-made water systems and in moist soil. Over the past 5 years, notification rates of this disease have almost doubled in the European Union (EU) / European Environmental Agency (EEA), from 1.4 in 2015 to 2.2 cases per 100,000 population in 2019. Some studies show that the greater presence of the microorganism in the water network and the increase in cases of legionellosis could be related to the variations in some environmental factors, such as air temperature, which may influence the water temperature. Study design: Climate change is currently a prominent topic worldwide because of its significant impact on the natural environment. It is responsible for the increase in numerous waterborne pathologies. The purpose of this study was to correlate the air temperature recorded in Apulia region from January 2018 to April 2023 with the presence of Legionella in the water networks of public and private facilities and the incidence rates of legionellosis during the same period. Methods: During the period from January 2018 to April 2023, water samples were collected from facilities involved in legionellosis cases and analyzed for Legionella. During the same period, all the cases notified to the regional epidemiological observatory (OER-Apulia) were included in this study. Statistical analyses were conducted using the Shapiro-Wilk test to determine whether the Legionella load was distributed normally, the Wilcoxon rank sum test to compare the air temperatures (average and range) of the negative and positive samples for Legionella detection, and the multivariate analysis (Poisson regression) to compare the Legionella load with the water sample temperature, average air temperature, and temperature range on the day of sampling. The Wilcoxon test for paired samples was used to compare legionellosis cases between the warmer and colder months. Results: Overall, 13,044 water samples were analyzed for Legionella and 460 cases of legionellosis were notified. Legionella was isolated in 20.1% of the samples examined. The difference in the air temperature between negative samples and positive samples was statistically significant (p-value < 0.0001): on days when water samples tested positive for Legionella a higher temperature range was observed than on days when water samples tested negative (p-value = 0.004). Poisson regression showed a direct correlation between Legionella load, water temperature, and average air temperature. The incidence of legionellosis cases in warmer months was higher than in colder months (p-value = 0.03). Conclusions: Our study highlights a significant increase in the load of Legionella in the Apulian water network, and an association between warmer temperatures and legionellosis incidence. In our opinion, further investigations are needed in different contexts and territories to characterize the epidemiology of legionellosis, and to explain its extreme variability in different geographical areas and how these data may be influenced by different risk factors.

2.
Ann Ig ; 31(5): 482-495, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31304528

RESUMEN

BACKGROUND: The study investigated 35 orthopedic OTs [17 with mixed flow (M-OTs), 18 with turbulent flow (T-OTs)]. METHODS: The OTs were divided into two categories based on recurring architectural and construction solutions, collected by a survey form: type-A (recently built or renovated rooms), and type-B (other OTs). Assessment of microbial air contamination (colony forming units (cfu)/m3 obtained by active sampling via Surface Air System) was then performed. RESULTS: In 97% of the OTs, a Total Viable Count (TVC) was within the limits recommended by ISPESL 2009; all A-type OTs, and 94% of B-type passed. The TVC of type-A OTs [median 15 cfu/m3, range 3-158] was lower than that of type-B OTs [median 28 cfu/m3, range 6-206], although the difference was not significant. The number of people in type-A [mean 8.6, range 6-11] was lower than in type-B [mean 9.6, range 7-13] OTs, and when adjusted to the volume of the OT (person/m3), showed a significant correlation with TVC (ρ = 0.383, p <0.05). CONCLUSIONS: In conclusion, the structural factors examined do not appear to significantly affect the microbiological air quality at the specific sampling point. However, further investigations are required to identify the factors that have the greatest effect on TVC.


Asunto(s)
Microbiología del Aire/normas , Monitoreo del Ambiente/métodos , Quirófanos/normas , Procedimientos Ortopédicos/normas , Contaminación del Aire , Contaminación del Aire Interior/prevención & control , Recuento de Colonia Microbiana , Hospitales/normas , Humanos , Ortopedia/normas
3.
Ann Ig ; 30(5): 401-409, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30062368

RESUMEN

BACKGROUND: Aflatoxins (AFs) are one of the main groups of mycotoxins produced by molds. Nuts, although recognized as a food with health benefits, are frequently contaminated by AFs. STUDY DESIGN: In this preliminary study we evaluated the contamination by total AFs and AFB1 in different types of nuts from different countries marketed in Apulia. METHODS: Overall, 124 samples (almonds, apricot kernels, chestnuts, hazelnuts, peanuts, pistachios, walnuts and Brazil nut) were analyzed using an High-Performance Liquid Chromatography system. RESULTS: Twenty samples (16.1%) were contaminated with AFs of which 55% were non-compliant, according to Reg. 165/2010. The median values (µg/kg) of total AFs and AFB1 were 16.6 and 15.1, respectively. Pistachios appeared more susceptible to AF contamination than the other nuts, with levels of total AFs ranging from 8.8 to 387.3 µg/kg and of AFB1 from 8.2 to 354.5 µg/kg. The majority of contaminated samples came from Asia and AF contamination was different in the various Asiatic sub-regions: regardless of the type of nuts, samples from Western Asia were the least contaminated. CONCLUSIONS: As geographical origin may influence the risk of contamination, in order to protect human health, customer countries should increase AF monitoring in nuts coming from those countries with favorable environments for the growth of aflatoxigenic molds or with less strict regulations.


Asunto(s)
Aflatoxina B1/análisis , Aflatoxinas/análisis , Contaminación de Alimentos/análisis , Nueces/química , Cromatografía Líquida de Alta Presión/normas , Comercio , Humanos , Italia
4.
Ann Ig ; 29(2): 92-100, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28244578

RESUMEN

The Study Group on Hospital Hygiene of the Italian Society of Hygiene, Preventive Medicine and Public Health (GISIO-SItI) and the Local Health Authority of Foggia, Apulia, Italy, after the National Convention "Safe water in healthcare facilities" held in Vieste-Pugnochiuso on 27-28 May 2016, present the "Vieste Charter", drawn up in collaboration with experts from the National Institute of Health and the Ministry of Health. This paper considers the risk factors that may affect the water safety in healthcare facilities and reports the current regulatory frameworks governing the management of installations and the quality of the water. The Authors promote a careful analysis of the risks that characterize the health facilities, for the control of which specific actions are recommended in various areas, including water safety plans; approval of treatments; healthcare facilities responsibility, installation and maintenance of facilities; multidisciplinary approach; education and research; regional and national coordination; communication.


Asunto(s)
Instituciones de Salud/normas , Seguridad/normas , Microbiología del Agua/normas , Abastecimiento de Agua/normas , Instituciones de Salud/legislación & jurisprudencia , Promoción de la Salud , Humanos , Italia , Salud Pública/legislación & jurisprudencia , Salud Pública/normas , Factores de Riesgo , Seguridad/legislación & jurisprudencia , Purificación del Agua/legislación & jurisprudencia , Purificación del Agua/normas , Abastecimiento de Agua/legislación & jurisprudencia
5.
Ann Ig ; 28(4): 282-7, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27479764

RESUMEN

BACKGROUND: Candidemia has become an increasingly important problem in infants hospitalized in the Neonatal Intensive Care Units (NICUs). Candida species are the third most common agents of late-onset infections in critically ill neonates and they are associated with high morbidity and mortality rates. In this study we evaluated the epidemiology of Candida bloodstream infections in the NICU of an Italian university hospital during a 15-year period. Our specific aims were to analyze the change in species distribution and the vitro susceptibility of these yeasts to fluconazole (FCZ) and amphotericin B (AmB). METHODS: A retrospective study of candidemia in the NICU of a university hospital in southern Italy, covering the years 2000-2014 was carried out. The isolates were identified using the VITEK2 yeast identification system and antifungal susceptibility was determined using the E-test method. RESULTS: Among the 57 patients with confirmed candidemia, 60% were males (n = 34 cases) and 82% (n = 47) had a gestational age of 24-32 weeks. Twenty-seven neonates (47%) had a very low birth weight (<1500 g), 20 (35%) an extremely low birth weight (<1000 g), and 10 (18%) a low birth weight (<2500 g). The most important potential risk factors were the placement of a central venous catheter, total parenteral nutrition, and endotracheal intubation (100%, each). Candida albicans was the most frequent yeast (47%), followed by Candida parapsilosis (44%). The proportion of Candida non-albicans increased slightly, from 46% in 2000-2004 to 71% in 2010-2014 (χ2 test for trend, p = 0.030). All isolates were susceptible to FCZ and AmB. CONCLUSIONS: The detection in this epidemiologic study of an increase in Candida non-albicans highlights the importance of correct species-level identification in the rapid diagnosis for an efficient treatment of candidemia. Knowledge of the local epidemiological trends in Candida species isolated in blood cultures will facilitate therapeutic decision-making.


Asunto(s)
Candidemia/epidemiología , Unidades de Cuidado Intensivo Neonatal/estadística & datos numéricos , Salud Pública , Catéteres Venosos Centrales/efectos adversos , Humanos , Recien Nacido con Peso al Nacer Extremadamente Bajo , Recién Nacido de Bajo Peso , Recién Nacido , Recien Nacido Prematuro , Recién Nacido de muy Bajo Peso , Intubación Intratraqueal/efectos adversos , Italia/epidemiología , Nutrición Parenteral/efectos adversos , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...