Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
2.
Eur J Case Rep Intern Med ; 10(4): 003774, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37051476

RESUMEN

A brain abscess is an enclosed focal infection within the brain that is either initiated by haematogenous seeding or spreads contiguously from oto-sinusitis, local trauma or neurosurgery. We describe the case of a 71-year-old man presenting with acute confusion and unilateral neurology in the absence of systemic signs of sepsis or associated laboratory biomarkers. While his initial clinical presentation mimicked an acute cerebrovascular event or brain tumour, he was subsequently diagnosed with a particularly large spherical temporal lobe brain abscess of 5 cm diameter on neuroimaging. This abscess was treated successfully with craniotomy, evacuation and a prolonged course of anti-microbials, enabling him to return to his pre-morbid level of functioning. His prolonged course of anti-microbials was complicated by candidaemia and colonisation of an indwelling central venous catheter that was treated successfully with anti-fungals. LEARNING POINTS: A high index of suspicion for brain abscess should be maintained when a ring-enhancing lesion is found on neuroimaging, even in the absence of signs of sepsis or associated laboratory biomarkers.Commensal yeasts may colonise indwelling lines in patients treated with long-term broad-spectrum antibiotics.Distracting concomitant diagnoses may delay recognition of the primary pathological process.

3.
J Urol ; 210(1): 179-185, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37000009

RESUMEN

PURPOSE: We prospectively assessed the ability of a novel transurethral catheterization safety valve to prevent urethral catheter balloon injury in a multi-institutional clinical setting. MATERIALS AND METHODS: A prospective, multi-institution study was conducted. The safety valve was introduced for urinary catheterization in 6 hospital groups (4 in Ireland; 2 in the UK). The safety valve allows fluid in the catheter system to vent through a pressure relief valve if attempted intraurethral inflation of the catheter's anchoring balloon occurs. Device usage was studied over a 12-month period, with data recorded using a 7-item data sticker containing a scannable QR code. "Venting" through the safety valve during catheterization was indicative of prevention of a urethral injury. An embedded 3-month study was conducted in 3 centers, with any catheter balloon injuries occurring during catheterization without safety valve use referred to the on-call urology team recorded. Health economic analyses were also performed. RESULTS: During the overall 12-month device study phase, 994 urethral catheterizations were performed across study sites. Twenty-two (2.2%) episodes of safety valve venting were recorded. No urethral injuries occurred in these patients. In the embedded 3-month study, 18 catheter balloon injuries were recorded in association with catheterizations performed without the safety valve. Based on confirmed and device-prevented urethral injuries, the injury rate for urethral catheterization without safety valve use was calculated to be 5.5/1,000 catheterizations. CONCLUSIONS: The safety valve has the potential to eliminate catheter balloon injury if widely adopted. It represents a simple, effective, and innovative solution to this recurring problem applicable to all patient cohorts.


Asunto(s)
Uretra , Cateterismo Urinario , Humanos , Uretra/lesiones , Estudios Prospectivos , Cateterismo Urinario/efectos adversos , Catéteres Urinarios/efectos adversos , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA