Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Am J Clin Pathol ; 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39066575

RESUMEN

OBJECTIVES: Urine drug testing (UDT) is a critical tool used in medical, forensic, and occupational settings, but interpreting results can be challenging. We performed a study to assess the ability of health care professionals to interpret UDT results accurately. METHODS: In total, 911 clinical and laboratory professionals in the United States and Canada responded to a survey with questions gauging expertise in UDT interpretation. Responses were analyzed to identify knowledge gaps. RESULTS: Toxicologists and laboratory PhD scientists performed well, with means of 4.82 and 4.63 questions answered correctly (out of 6 possible), respectively. Physicians specializing in pathology, emergency medicine, primary care, and internal medicine, however, displayed concerning knowledge gaps, as did laboratorians with nondoctoral degrees. Experience and training correlated with interpretation accuracy. Identification of simulated compliance as well as understanding opioid exposure, metabolism, and immunoassay cross-reactivity were among the most clinically significant knowledge gaps. More than 30% of survey respondents indicated that they would seek UDT information from the internet or peers rather than clinical or laboratory experts. CONCLUSIONS: The study highlighted the need for targeted education and better collaboration between clinical and laboratory experts and other health care professionals to ensure that when physicians order UDT, they can accurately interpret results and reduce harm.

3.
J Forensic Sci ; 65(4): 1392, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32609402
5.
Clin Chem ; 66(3): 434-444, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-32109298

RESUMEN

BACKGROUND: How to select healthy reference subjects in deriving 99th percentiles for cardiac troponin assays still needs to be clarified. To assist with global implementation of high sensitivity (hs)-cardiac troponin (cTn) I and hs-cTnT assays in clinical practice, we determined overall and sex-specific 99th percentiles in 9 hs-cTnI and 3 hs-cTnT assays using a universal sample bank (USB). METHODS: The Universal Sample Bank (USB) comprised healthy subjects, 426 men and 417 women, screened using a health questionnaire. Hemoglobin A1c (>URL 6.5%), NT-proBNP (>URL 125 ng/L) and eGFR (<60 mL/min), were used as surrogate biomarker exclusion criteria along with statin use. 99th percentiles were determined by nonparametric, Harrell--Davis bootstrap, and robust methods. RESULTS: Subjects were ages 19 to 91 years, Caucasian 58%, African American 27%, Pacific Islander/Asian 11%, other 4%, Hispanic 8%, and non-Hispanic 92%. The overall and sex-specific 99th percentiles for all assays, before and after exclusions (n = 694), were influenced by the statistical method used, with substantial differences noted between and within both hs-cTnI and hs-cTnT assays. Men had higher 99th percentiles (ng/L) than women. The Roche cTnT and Beckman and Abbott cTnI assays (after exclusions) did not measure cTn values at ≥ the limit of detection in ≥50% women. CONCLUSIONS: Our findings have important clinical implications in that sex-specific 99th percentiles varied according to the statistical method and hs-cTn assay used, not all assays provided a high enough percentage of measurable concentrations in women to qualify as a hs-assay, and the surrogate exclusion criteria used to define normality tended to lower the 99th percentiles.


Asunto(s)
Bioensayo/métodos , Troponina I/sangre , Troponina T/sangre , Adulto , Anciano , Anciano de 80 o más Años , Bioensayo/normas , Bancos de Muestras Biológicas , Biomarcadores/sangre , Femenino , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Juego de Reactivos para Diagnóstico , Valores de Referencia , Factores Sexuales , Troponina I/normas , Troponina T/normas , Adulto Joven
6.
J Appl Lab Med ; 4(2): 180-192, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31639663

RESUMEN

BACKGROUND: GEM Premier ChemSTAT™ is a point-of-care (POC) system that measures Na+, K+, Ca++, Cl-, glucose, hematocrit, creatinine, blood urea nitrogen (BUN), tCO2, pH, pCO2, and lactate from a single whole blood specimen, providing rapid results in POC settings such as the emergency department (ED). Accurate measurements of creatinine in whole blood and reporting of estimated glomerular filtration rate (eGFR) can minimize adverse effects of contrast-induced nephropathy. METHODS: Heparinized whole blood specimens from the ED were analyzed on the ChemSTAT by POC staff. Method comparison was performed against the cobas Integra c501 for creatinine, BUN, and tCO2, and against the GEM Premier 4000 for all other analytes. Precision was conducted with whole blood specimens assayed in triplicate over 6 days. Creatinine results from whole blood and plasma were used for eGFR, by isotope dilution mass spectrometry-traceable Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration equations, and eGFR concordance was assessed. RESULTS: Creatinine, BUN, and tCO2 correlated well with plasma samples on the cobas, and all other analytes correlated well with whole blood specimens on the GEM Premier 4000 across the tested sample ranges. The regression slope was 0.951 to 1.047, along with a correlation coefficient (r) of ≥0.982 for all analytes. The pooled within-sample precision was 0% to 2.5% for all analytes. CONCLUSIONS: ChemSTAT demonstrated a strong correlation with the comparative methods and excellent precision. The system's analytical performance and continuous quality management make it suitable for use in the ED to provide rapid reliable test results, which could minimize the time to treatment and improve ED efficiency.


Asunto(s)
Creatinina/sangre , Pruebas Diagnósticas de Rutina/instrumentación , Enfermedades Renales/diagnóstico , Riñón/fisiología , Pruebas en el Punto de Atención , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Nitrógeno de la Urea Sanguínea , Dióxido de Carbono/sangre , Niño , Medios de Contraste/efectos adversos , Servicio de Urgencia en Hospital , Femenino , Tasa de Filtración Glomerular/fisiología , Humanos , Riñón/diagnóstico por imagen , Enfermedades Renales/sangre , Enfermedades Renales/inducido químicamente , Enfermedades Renales/prevención & control , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Factores de Tiempo , Adulto Joven
7.
Am J Med ; 132(7): 869-874, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30849383

RESUMEN

OBJECTIVE: Our objective was to examine the appropriateness of cardiac troponin (cTn) testing among patients with cTn increases. METHODS: This is a planned secondary analysis of the Use of TROPonin In Acute coronary syndromes (UTROPIA, NCT02060760) observational cohort study. Appropriateness of cTn testing was adjudicated for emergency department patients with cTn increases >99th percentile and analyzed using both contemporary and high-sensitivity (hs) cTnI assays according to sub-specialty, diagnoses, and symptoms. RESULTS: Appropriateness was determined from 1272 and 1078 adjudication forms completed for 497 and 422 patients with contemporary and hs-cTnI increases, respectively. Appropriateness of cTnI testing across adjudication forms was 71.5% and 72.0% for cTnI and hs-cTnI, respectively. Compared with emergency physicians, cardiologists were less likely to classify cTnI orders as appropriate (cTnI: 79% vs 56%, P < .0001; hs-cTnI: 82% vs 51%, P < .0001). For contemporary cTnI, appropriateness of 95%, 70%, and 39% was observed among adjudication forms completed by cardiologists for type 1 myocardial infarction, type 2 myocardial infarction, and myocardial injury, respectively; compared with 90%, 86%, and 71%, respectively, among emergency physicians. Similar findings were observed using hs-cTnI. Discordance in appropriateness adjudication forms occurred most frequently in cases of myocardial injury (62% both assays) or type 2 myocardial infarction (cTnI 31%; hs-cTnI 23%). CONCLUSIONS: Marked differences exist in the perception of what constitutes appropriate clinical use of cTn testing between cardiologists and emergency physicians, with emergency physicians more likely to see testing as appropriate across a range of clinical scenarios. Discordance derives most often from cases classified as myocardial injury or type 2 myocardial infarction.


Asunto(s)
Síndrome Coronario Agudo/sangre , Troponina C/sangre , Adulto , Biomarcadores/sangre , Cardiología/estadística & datos numéricos , Servicio de Urgencia en Hospital/estadística & datos numéricos , Femenino , Humanos , Masculino , Infarto del Miocardio/sangre , Infarto del Miocardio/diagnóstico , Pautas de la Práctica en Medicina/estadística & datos numéricos
8.
Acad Forensic Pathol ; 8(3): 729-737, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31240067

RESUMEN

Over a three-month period in early 2017, the Hennepin County Medical Examiner's Office investigated nine apparent opioid toxicity deaths that occurred in three separate urban, suburban, and rural counties in our jurisdiction. All decedents were known substance abusers and had reportedly recently used heroin; most were found with drug paraphernalia. Complete autopsies variably showed classic stigmata of opioid overdose with no significant injury or natural disease to explain death. Initial toxicology screens failed to identify heroin or other narcotic substances. Several cases were presumptively positive for fentanyl by immunoassay, yet failed to confirm positive for fentanyl. Following American Board of Forensic Toxicology reporting standards, these cases were reported as negative for fentanyl by the laboratory. Due to the discrepant scene and toxicology findings suggestive of an opioid toxicity death, further discussion between the medical examiners and toxicologists prompted additional testing at a referral laboratory. This resulted in quantifiable blood carfentanil in all cases (mean 0.26 ng/mL, range 0.12 - 0.64 ng/mL). Cointoxicants included ethanol (n=2), methamphetamine (n=3), benzodiazepines (n=3), and cocaine (n=1). No case had definitive evidence of acute heroin intoxication, but two cases had low concentrations of morphine present (0.03 and 0.06 ng/mL), and two others had 6-monoacetyl morphine in the urine without morphine in the blood, suggesting recent use. All deaths were certified as accidental acute or mixed carfentanil toxicity. These cases present additional information about carfentanil-related deaths and highlight the importance of collaboration between forensic pathologists and toxicologists.

9.
Clin Biochem ; 52: 174, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29162471
10.
J Forensic Sci ; 63(1): 191-194, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28422290

RESUMEN

Over the past two decades, prescription and illicit opioid use has led to changes in public health policy to address the increasing number of opioid-related deaths. The purpose of this study was to review cases from Hennepin County Medical Examiner's Office between 2004 through 2015 where heroin was listed as a significant contributor or as the cause of death. We identified 322 heroin-related deaths, which were predominantly male (255; 79%). 6-Monoacetylmorphine (6-MAM) median (range) concentrations were as follows: blood (n = 7), 0.010 (0.006-0.078) mg/L; urine (n = 30), 0.359 (0.009-1.75) mg/L; and vitreous humor (n = 31), 0.034 (0.004-0.24) mg/L. Free morphine was measurable in 273 cases and the percent free morphine (range), when grouped by COD, was opioid (n = 124), 28% (2.2%-92%), and mixed drug toxicity (n = 135), 35.3% (1.5%-100%); (p < 0.01). Quantitation of 6-MAM in blood and vitreous humor, along with a free to total morphine ratio >26%, was useful in establishing heroin-related deaths.


Asunto(s)
Dependencia de Heroína/mortalidad , Accidentes/estadística & datos numéricos , Adulto , Médicos Forenses , Sobredosis de Droga/mortalidad , Femenino , Cromatografía de Gases y Espectrometría de Masas , Dependencia de Heroína/sangre , Dependencia de Heroína/orina , Homicidio/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Minnesota/epidemiología , Morfina/análisis , Derivados de la Morfina/análisis , Estudios Retrospectivos , Distribución por Sexo , Suicidio/estadística & datos numéricos , Cuerpo Vítreo/química
11.
Am J Clin Pathol ; 149(1): 82-86, 2017 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-29228083

RESUMEN

OBJECTIVES: The present study addressed the accuracy of calculated oxygen saturation (sO2) using point-of-care (POC) testing compared with measured values on a blood gas analyzer. METHODS: In total, 3,323 sO2 values were measured in 1,180 patients using a CO-oximeter (ABL 800 Flex; Radiometer, Copenhagen, Denmark). Measured parameters were then used to calculate an expected sO2 for the POC method (Abbott i-STAT; Abbott POC, Princeton, NJ). Cases in which calculated sO2 differed from measured sO2 by 10% or more were analyzed. RESULTS: Of the 3,323 comparisons performed, 260 (8%) showed discrepancies (± ≥10%) between measured and calculated sO2 values. Ninety-four of discrepant measurements (245 of 260) occurred when pO2 was less than 50 mm Hg. pH and bicarbonate distributions shifted to lower values in discrepant vs nondiscrepant cases. CONCLUSIONS: Our results suggest that the likelihood of discrepant sO2 is 27% among patients with pO2 less than 50 mm Hg. Direct measurement of sO2 by CO-oximetry is strongly suggested in this clinical scenario.


Asunto(s)
Análisis de los Gases de la Sangre/normas , Hipoxia/sangre , Oxígeno/sangre , Pruebas en el Punto de Atención/normas , Análisis de los Gases de la Sangre/instrumentación , Femenino , Humanos , Masculino , Oximetría , Sistemas de Atención de Punto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
Clin Biochem ; 50(18): 1073-1077, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28916437

RESUMEN

OBJECTIVES: Our purpose was to determine a) overall and sex-specific 99th percentile upper reference limits (URL) and b) influences of statistical methods and comorbidities on the URLs. METHODS: Heparin plasma from 838 normal subjects (423 men, 415 women) were obtained from the AACC (Universal Sample Bank). The cobas e602 measured cTnT (Roche Gen 5 assay); limit of detection (LoD), 3ng/L. Hemoglobin A1c (URL 6.5%), NT-proBNP (URL 125ng/L) and eGFR (60mL/min/1.73m2) were measured, along with identification of statin use, to better define normality. 99th percentile URLs were determined by the non-parametric (NP), Harrell-Davis Estimator (HDE) and Robust (R) methods. RESULTS: 355 men and 339 women remained after exclusions. Overall<50% of subjects had measureable concentrations ≥ LoD: 45.6% no exclusion, 43.5% after exclusion; compared to men: 68.1% no exclusion, 65.1% post exclusion; women: 22.7% no exclusion, 20.9% post exclusion. The statistical method used influenced URLs as follows: pre/post exclusion overall, NP 16/16ng/L, HDE 17/17ng/L, R not available; men NP 18/16ng/L, HDE 21/19ng/L, R 16/11ng/L; women NP 13/10ng/L, HDE 14/14ng/L, R not available. CONCLUSIONS: We demonstrated that a) the Gen 5 cTnT assay does not meet the IFCC guideline for high-sensitivity assays, b) surrogate biomarkers significantly lowers the URLs and c) statistical methods used impact URLs. Our data suggest lower sex-specific cTnT 99th percentiles than reported in the FDA approved package insert. We emphasize the importance of detailing the criteria used to include and exclude subjects for defining a healthy population and the statistical method used to calculate 99th percentiles and identify outliers.


Asunto(s)
Bancos de Muestras Biológicas/estadística & datos numéricos , Bancos de Muestras Biológicas/normas , Heparina/análisis , Adulto , Bioensayo/métodos , Bioensayo/normas , Biomarcadores/sangre , Comorbilidad , Femenino , Heparina/sangre , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , Estándares de Referencia , Valores de Referencia , Factores Sexuales , Troponina I/análisis , Troponina I/sangre , Troponina T/análisis , Troponina T/sangre
13.
Am J Med ; 130(12): 1431-1439.e4, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28739197

RESUMEN

BACKGROUND: Studies addressing patients with type 2 myocardial infarction and myocardial injury, including the impact of using high-sensitivity (hs) cardiac troponin (cTn) assays on their incidence are needed. METHODS: Ours is a prospective, observational US cohort study. Consecutive emergency department patients with serial cTnI measurements were studied. Outcomes included 180-day mortality and major adverse cardiac events, including 2-year follow-up for those with myonecrosis. RESULTS: Among 1640 patients, using a contemporary cTnI assay, 30% (n = 497) had ≥1 cTnI >99th percentile, with 4.7% (n = 77), 8.5% (n = 140), and 17% (n = 280) classified as type 1 myocardial infarction, type 2 myocardial infarction, and myocardial injury, respectively. Compared with patients without myonecrosis, 180-day mortality was higher for type 2 myocardial infarction (4% vs 13%, P < .0001) (adjusted hazard ratio 2.7; 95% confidence interval, 1.6-4.8; P = .0005) and myocardial injury (4% vs 11%, P < .0001) (adjusted hazard ratio 1.8; 95% confidence interval, 1.1-3.0; P = .02), both with mortality >20% at 2 years. Predictors of 2-year mortality for type 2 myocardial infarction included age, congestive heart failure, and beta-blockers. Relative to the contemporary cTnI assay, hs-cTnI had less myonecrosis (30% vs 26%, P = .003) and acute myocardial infarction (13.2% vs 10.8%, P = .032), including fewer type 2 myocardial infarctions (8.5% vs 6.3, P = .01), with no difference in myocardial injury (17% vs 15%, P = .1). CONCLUSIONS: cTnI increases are encountered in approximately a third of patients, the majority due to nonatherothrombotic conditions. Compared with patients without myonecrosis, type 2 myocardial infarction and myocardial injury have worse short-term outcomes, with mortality rates >20% at 2 years. hs-cTnI assay does not lead to more myocardial injury or infarction.


Asunto(s)
Lesiones Cardíacas/sangre , Infarto del Miocardio/sangre , Infarto del Miocardio/clasificación , Troponina I/sangre , Femenino , Lesiones Cardíacas/diagnóstico , Lesiones Cardíacas/epidemiología , Lesiones Cardíacas/terapia , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/epidemiología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sensibilidad y Especificidad
14.
Clin Chem ; 63(10): 1594-1604, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28701316

RESUMEN

BACKGROUND: We examined the diagnostic performance of high-sensitivity cardiac troponin I (hs-cTnI) vs contemporary cTnI with use of the 99th percentile alone and with a normal electrocardiogram (ECG) to rule out acute myocardial infarction (MI) and serial changes (deltas) to rule in MI. METHODS: We included consecutive patients presenting to a US emergency department with serial cTnI onclinical indication. Diagnostic performance for acute MI, including MI subtypes, and 30-day outcomes were examined. RESULTS: Among 1631 patients, MI was diagnosed in 12.9% using the contemporary cTnI assay and in 10.4% using the hs-cTnI assay. For ruling out MI, contemporary cTnI ≤99th percentile at 0, 3, and 6 h and a normal ECG had a negative predictive value (NPV) of 99.5% (95% CI, 98.6-100) and a sensitivity of 99.1% (95% CI, 97.4-100) for diagnostic and safety outcomes. Serial hs-cTnI measurements ≤99th percentile at 0 and 3 h and a normal ECG had an NPV and sensitivity of 100% (95% CI, 100-100) for diagnostic and safety outcomes. For ruling in MI, contemporary cTnI measurements had specificities of 84.4% (95% CI, 82.5-86.3) at presentation and 78.7% (95% CI, 75.4-82.0) with serial testing at 0, 3, and 6 h, improving to 89.2% (95% CI, 87.1-91.3) by using serial cTnI changes (delta, 0 and 6 h) >150%. hs-cTnI had specificities of 86.9% (95% CI, 85.1-88.6) at presentation and 85.7% (95% CI, 83.5-87.9) with serial testing at 0 and 3 h, improving to 89.3% (95% CI, 87.3-91.2) using a delta hs-cTnI (0 and 3 h) >5 ng/L. CONCLUSIONS: hs-cTnI and contemporary cTnI assays are excellent in ruling out MI following recommendations predicated on serial testing and the 99th percentile with a normal ECG. For ruling in MI, deltas improve the specificity. ClinicalTrials.gov Identifier: NCT02060760.


Asunto(s)
Infarto del Miocardio/diagnóstico , Troponina I/análisis , Biomarcadores/análisis , Técnicas de Laboratorio Clínico , Femenino , Humanos , Masculino , Pronóstico , Sensibilidad y Especificidad
15.
Am J Med ; 130(9): 1076-1083.e1, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28344141

RESUMEN

BACKGROUND: This study examined the performance of single high-sensitivity cardiac troponin I (hs-cTnI) measurement strategies to rule out acute myocardial infarction. METHODS: This was a prospective, observational study of consecutive patients presenting to the emergency department (n = 1631) in whom cTnI measurements were obtained using an investigational hs-cTnI assay. The goals of the study were to determine 1) negative predictive value (NPV) and sensitivity for the diagnosis of acute myocardial infarction, type 1 myocardial infarction, and type 2 myocardial infarction; and 2) safety outcome of acute myocardial infarction or cardiac death at 30 days using hs-cTnI less than the limit of detection (LoD) (<1.9 ng/L) or the High-STEACS threshold (<5 ng/L) alone and in combination with normal electrocardiogram (ECG). RESULTS: Acute myocardial infarction occurred in 170 patients (10.4%), including 68 (4.2%) type 1 myocardial infarction and 102 (6.3%) type 2 myocardial infarction. For hs-cTnI

Asunto(s)
Infarto del Miocardio/sangre , Troponina I/sangre , Enfermedad Aguda , Bioensayo/métodos , Biomarcadores/sangre , Electrocardiografía , Servicio de Urgencia en Hospital/estadística & datos numéricos , Humanos , Infarto del Miocardio/diagnóstico , Valor Predictivo de las Pruebas , Estudios Prospectivos
16.
Clin Biochem ; 50(4-5): 181-185, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27823960

RESUMEN

BACKGROUND: Circulating B-type natriuretic peptide (BNP) is widely accepted as a diagnostic and risk assessment biomarker of cardiac function. Studies suggest that there are significant differences in measured concentrations among different commercial BNP immunoassays. The purpose of our study was to compare BNP-related proteins to determine a form that could be used as a common calibrator to improve the comparability of commercial BNP immunoassay results. METHODS: BNP was measured in 40 EDTA-plasma samples from acute and chronic heart failure patients using five commercial BNP assays: Alere Triage, Siemens Centaur XP, Abbott I-STAT, Beckman Access2 and ET Healthcare Pylon. In parallel with internal calibrators from each manufacturer, six preparations containing BNP 1-32 motif a) synthetic BNP, b) recombinant BNP (E. coli), c) recombinant nonglycosylated proBNP (E. coli), d) recombinant His-tagged (N-terminal) nonglycosylated proBNP (E. coli), e) recombinant glycosylated proBNP (HEK cells), and f) recombinant glycosylated proBNP (CHO cells) were also used as external calibrators for each assay. RESULTS: Using the internal standards provided by manufacturers and for five of six external calibrators, up to 3.6-fold differences (mean 1.9-fold) were observed between BNP immunoassays (mean between-assay CV 24.5-47.2%). A marked reduction of the between-assay variability was achieved, when glycosylated proBNP expressed in HEK cells was used as the common calibrator for all assays (mean between-assay CV 14.8%). CONCLUSIONS: Our data suggest that recombinant glycosylated proBNP could serve as a common calibrator for BNP immunoassays to reduce between-assay variability and achieve better comparability of BNP concentrations of commercial BNP immunoassays.


Asunto(s)
Análisis Químico de la Sangre/normas , Péptido Natriurético Encefálico/sangre , Precursores de Proteínas/sangre , Animales , Células CHO , Cricetinae , Cricetulus , Glicoproteínas/sangre , Células HEK293 , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/diagnóstico , Humanos , Inmunoensayo/normas , Estándares de Referencia
17.
Clin Chem ; 63(1): 369-376, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27811203

RESUMEN

BACKGROUND: Rapid rule-out strategies using high-sensitivity cardiac troponin assays are largely supported by studies performed outside the US in selected cohorts of patients with chest pain that are atypical of US practice, and focused exclusively on ruling out acute myocardial infarction (AMI), rather than acute myocardial injury, which is more common and associated with a poor prognosis. METHODS: Prospective, observational study of consecutive patients presenting to emergency departments [derivation (n = 1647) and validation (n = 2198) cohorts], where high-sensitivity cardiac troponin I (hs-cTnI) was measured on clinical indication. The negative predictive value (NPV) and diagnostic sensitivity of an hs-cTnI concentration

Asunto(s)
Isquemia Miocárdica/sangre , Troponina I/sangre , Enfermedad Aguda , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico
18.
J Appl Lab Med ; 1(6): 711-719, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33379817

RESUMEN

BACKGROUND: International guidelines authored and endorsed by professional societies of cardiology, emergency medicine, and laboratory medicine are unanimous that the cutoff concentration for establishing a diagnosis of acute myocardial infarction be set at the 99th percentile of a healthy population. The establishment of the actual 99th percentile value is assay- and sample-dependent and is influenced by the population of individuals selected for testing. We created a sample bank that will enable manufacturers of troponin assays a consistent comparison of the 99th percentile. METHODS: Participants were recruited from those attending the 2015 Annual Meeting of the AACC for the creation of a universal sample bank of apparently healthy individuals (free from uncontrolled diabetes, renal insufficiency, and heart disease). For those who met eligibility criteria and signed a written consent to participate, 60 mL blood was collected into 6 10-mL tubes each (2 serum, 3 heparin plasma, and 1 EDTA). Whole blood was tested for hemoglobin (Hb) A1c, and serum was tested for N-terminal pro-B-type natriuretic peptide (NT-proBNP) and creatinine. RESULTS: There were a total of 764 individuals who consented during the AACC Annual Meeting. After this initial enrollment, it was determined that there was an insufficient number of male participants recruited. Under the same protocol and consent, blood from 131 additional males was collected at the University of Maryland. Samples were centrifuged, and 240 µL aliquots of the 2 serum, 3 heparin plasma, and 1 EDTA tubes were frozen at 70 °C within 2 h of collection. The labeled samples were divided into boxes containing 1 aliquot from each individual. Sets of these samples were made available for purchase to manufacturers of cardiac troponin assays. Eighty-eight samples were excluded from the database for having a high NT-proBNP (>300 ng/L), low estimated glomerular filtration rate (eGFR) (<60 mL/min/1.73 m2), high Hb A1c (≥6.5%), or preanalytical sample issues and consenting/data issues. The final total was 808 individuals (402 females and 406 males; 60% Caucasian, 26% African or African American, 11% Asian or Pacific Islander, and 3% other). CONCLUSIONS: The creation of a bank of samples from healthy individuals enables a consistent comparison of the 99th percentile results from manufacturers of cardiac troponin assays.

19.
J Anal Toxicol ; 40(8): 659-662, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27590035

RESUMEN

Urine drug testing is commonly performed in both clinical and forensic arenas for screening, monitoring and compliance purposes. We sought to determine if urine creatinine concentrations in monitoring program participants were significantly different from hospital in-patients and out-patients undergoing urine drug testing. We retrospectively reviewed urine creatinine submitted in June through December 2015 for all specimens undergoing urine drug testing. The 20,479 creatinine results were categorized as hospitalized patients (H) and monitoring/compliance groups for pain management (P), legal (L) or recovery (R). Median creatinine concentrations (interquartile range, mg/dL) were significantly different (P < 0.001) between groups: H 126 (122-136); P 138 (137-143); L 147 (144-154); R 95 (92-97). In the two groups subject to on-demand sampling time pressures, median creatinine concentrations were significantly lower in the R vs. L group (P<0.001). In conclusion, recovery (R) participants have more dilute specimens, reflected by significantly lower creatinine concentration and may indicate participants' attempts to tamper with their drug test results through dilution means.


Asunto(s)
Creatinina/orina , Monitoreo de Drogas , Hospitalización , Humanos , Dolor/tratamiento farmacológico , Dolor/orina , Manejo del Dolor , Estudios Retrospectivos , Manejo de Especímenes , Detección de Abuso de Sustancias/métodos , Trastornos Relacionados con Sustancias/terapia , Trastornos Relacionados con Sustancias/orina , Urinálisis
20.
Clin Chem ; 62(8): 1115-9, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27324737

RESUMEN

INTRODUCTION: We compared the incidence of undetectable [below the limit of detection (LoD)], measurable (LoD to 99th percentile), and increased cardiac troponin I (cTnI) concentrations above the 99th percentile between Abbott high-sensitivity cTnI (hs-cTnI) and contemporary cTnI assays in a US emergency department population. METHODS: Patients (n = 2100) presenting to the emergency department who had serial cTnI (0, 3, 6, 9 h) measurements ordered on clinical indication were enrolled. Contemporary cTnI [Abbott Architect used clinically; 99th percentile: 0.030 µg/L (30 ng/L)] and hs-cTnI [Abbott investigational; sex-specific 99th percentiles: female (F) 16 ng/L, male (M) 34 ng/L] assays simultaneously measured fresh EDTA plasma. RESULTS: The hs-cTnI assay measured fewer undetectable cTnI concentrations compared to the contemporary cTnI assay across baseline (F: 31% vs 47%, M: 22% vs 40%) and serial (F: 21% vs 46%; M: 19% vs 54%) measurements. Conversely, the proportion of measurable cTnI concentrations was higher using hs-cTnI compared to contemporary cTnI assay across both baseline (F: 46% vs 31%; M: 60% vs 33%) and serial (F: 48% vs 28%; M: 83% vs 40%) measurements. The overall proportion of patients with increased cTnI concentrations above the 99th percentile was not significantly different between the contemporary (31%) and hs-cTnI (26%) assays (P = 0.09). CONCLUSIONS: In patients presenting to the emergency department, the use of the Abbott hs-cTnI assay provides clinicians with more numeric cTnI concentrations. This occurs via a shift from results below the LoD to those between the LoD and the 99th percentile and does not increase in the number of cTnI concentrations above the 99th percentile.


Asunto(s)
Análisis Químico de la Sangre , Servicio de Urgencia en Hospital , Troponina I/sangre , Anciano , Análisis Químico de la Sangre/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA