Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Perfusion ; 37(7): 729-737, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34034594

RESUMEN

INTRODUCTION: To determine the oxygenator impact on alterations of meropenem (MEM)/vaborbactam (VBR) in a contemporary neonatal/pediatric (1/4-inch) and adolescent/adult (3/8-inch) extra corporeal membrane oxygenation (ECMO) circuit including the Quadrox-i® oxygenator. METHODS: 1/4-inch and 3/8-inch, simulated closed-loop ECMO circuits were prepared with a Quadrox-i pediatric and Quadrox-i adult oxygenator and blood primed. Additionally, 1/4-inch and 3/8-inch circuits were also prepared without an oxygenator in series. A one-time dose of MEM/VBR was administered into the circuits and serial pre- and post-oxygenator concentrations were obtained at 5 minutes, 1, 2, 3, 4, 5, 6, 8, 12, and 24-hour time points. MEM/VBR was also maintained in a glass vial and samples were taken from the vial at the same time periods for control purposes to assess for spontaneous drug degradation. RESULTS: For the 1/4-inch circuit, there was an approximate mean 55% MEM loss with the oxygenator in series and a mean 33%-40% MEM loss without an oxygenator in series at 24 hours. For the 3/8-inch circuit, there was an approximate mean 70% MEM loss with the oxygenator in series and a mean 30%-38% MEM loss without an oxygenator in series at 24 hours. For both the 1/4-inch circuit and 3/8-inch circuits with and without an oxygenator, there was <10% VBR loss for the duration of the experiment. CONCLUSIONS: This ex-vivo investigation demonstrated substantial MEM loss within an ECMO circuit with an oxygenator in series with both sizes of the Quadrox-i oxygenator at 24 hours and no significant VBR loss. Further evaluations with multiple dose in-vitro and in-vivo investigations are needed before specific MEM/VBR dosing recommendations can be made for clinical application with ECMO.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Oxigenadores de Membrana , Adolescente , Adulto , Ácidos Borónicos , Niño , Humanos , Recién Nacido , Meropenem/farmacología
2.
Perfusion ; 35(6): 529-533, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32627659

RESUMEN

INTRODUCTION: To determine the oxygenator impact on alterations of voriconazole in a contemporary neonatal/pediatric (1/4 inch) and adolescent/adult (3/8 inch) extracorporeal membrane oxygenation circuit including the Quadrox-i® oxygenator. METHODS: Simulated closed-loop extracorporeal membrane oxygenation circuits (1/4 and 3/8 inch) were prepared with a Quadrox-i pediatric and Quadrox-i adult oxygenator and blood primed. In addition, 1/4- and 3/8-inch circuits were also prepared without an oxygenator in series. A one-time dose of voriconazole was administered into the circuits, and serial pre- and post-oxygenator concentrations were obtained at 5 minutes, 1, 2, 3, 4, 5, 6, and 24 hour time points. Voriconazole was also maintained in a glass vial and samples were taken from the vial at the same time periods for control purposes to assess for spontaneous drug degradation. RESULTS: For the 1/4-inch circuit, there was an approximate mean of 64-67% voriconazole loss with the oxygenator in series and mean of 15-20% voriconazole loss without an oxygenator in series at 24 hours. For the 3/8-inch circuit, there was an approximate mean of 44-51% voriconazole loss with the oxygenator in series and a mean of 8-12% voriconazole loss without an oxygenator in series at 24 hours. The reference voriconazole concentrations remained relatively constant during the entire study period demonstrating that the drug loss in each size of the extracorporeal membrane oxygenation circuit with or without an oxygenator was not a result of spontaneous drug degradation. CONCLUSION: This ex vivo investigation demonstrated substantial voriconazole loss within an extracorporeal membrane oxygenation circuit with an oxygenator in series with both sizes of the Quadrox-i oxygenator at 24 hours and no significant voriconazole loss in the absence of an oxygenator. Further evaluations with multiple dose in vitro and in vivo investigations are needed before specific voriconazole dosing recommendations can be made for clinical application with extracorporeal membrane oxygenation.


Asunto(s)
Inhibidores del Citocromo P-450 CYP3A/uso terapéutico , Oxigenación por Membrana Extracorpórea/métodos , Oxigenadores de Membrana/normas , Voriconazol/uso terapéutico , Inhibidores del Citocromo P-450 CYP3A/farmacología , Humanos , Voriconazol/farmacología
3.
Pediatr Crit Care Med ; 21(3): 276-282, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31688715

RESUMEN

OBJECTIVES: To determine the oxygenator impact on alterations of ceftolozane/tazobactam in a contemporary neonatal/pediatric (1/4-inch) and adolescent/adult (3/8-inch) extracorporeal membrane oxygenation circuit including the Quadrox-i oxygenator (Maquet, Wayne, NJ). DESIGN: A 1/4-inch and 3/8-inch, simulated closed-loop extracorporeal membrane oxygenation circuits were prepared with a Quadrox-i pediatric and Quadrox-i adult oxygenator and blood primed. Additionally, 1/4-inch and 3/8-inch circuits were also prepared without an oxygenator in series. A one-time dose of ceftolozane/tazobactam was administered into the circuits and serial preoxygenator and postoxygenator concentrations were obtained at 5 minutes, 1, 2, 3, 4, 5, 6, and 24-hour time points. Ceftolozane/tazobactam was also maintained in a glass vial and samples were taken from the vial at the same time periods for control purposes to assess for spontaneous drug degradation SETTING:: A free-standing extracorporeal membrane oxygenation circuit. PATIENTS: None. INTERVENTIONS: Single-dose administration of ceftolozane/tazobactam into closed-loop extracorporeal membrane oxygenation circuits prepared with and without an oxygenator in series with serial preoxygenator, postoxygenator, and reference samples obtained for concentration determination over a 24-hour study period. MEASUREMENTS AND MAIN RESULTS: For the 1/4-inch circuit, there was approximately 92% ceftolozane and 22-25% tazobactam loss with the oxygenator in series and 19-30% ceftolozane and 31-34% tazobactam loss without an oxygenator in series at 24 hours. For the 3/8-inch circuit, there was approximately 85% ceftolozane and 29% tazobactam loss with the oxygenator in series and 25-27% ceftolozane and 23-26% tazobactam loss without an oxygenator in series at 24 hours. The reference ceftolozane and tazobactam concentrations remained relatively constant during the entire study period demonstrating the drug loss in each size of the extracorporeal membrane oxygenation circuit with or without an oxygenator was not a result of spontaneous drug degradation. CONCLUSIONS: This ex vivo investigation demonstrated substantial ceftolozane loss within an extracorporeal membrane oxygenation circuit with an oxygenator in series with both sizes of the Quadrox-i oxygenator at 24 hours and significant ceftolozane loss in the absence of an oxygenator. Tazobactam loss was similar regardless of the presence of an oxygenator. Further evaluations with multiple dose in vitro and in vivo investigations are needed before specific drug dosing recommendations can be made for clinical application with extracorporeal membrane oxygenation.


Asunto(s)
Antibacterianos/administración & dosificación , Cefalosporinas/administración & dosificación , Oxigenación por Membrana Extracorpórea/instrumentación , Oxigenación por Membrana Extracorpórea/métodos , Oxigenadores de Membrana , Tazobactam/administración & dosificación , Adolescente , Adulto , Antibacterianos/farmacocinética , Cefalosporinas/farmacocinética , Niño , Preescolar , Diseño de Equipo , Humanos , Lactante , Recién Nacido , Tasa de Depuración Metabólica , Tazobactam/farmacocinética , Adulto Joven
4.
Pediatr Crit Care Med ; 19(11): 1077-1082, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30048366

RESUMEN

OBJECTIVES: To determine the oxygenator impact on alterations of ceftaroline in a contemporary neonatal/pediatric (1/4-inch) and adolescent/adult (3/8-inch) extracorporeal membrane oxygenation circuit including the Quadrox-i oxygenator (Maquet, Wayne, NJ). DESIGN: Quarter-inch and 3/8-inch, simulated closed-loop extracorporeal membrane oxygenation circuits were prepared with a Quadrox-i pediatric and Quadrox-i adult oxygenator and blood primed. Additionally, 1/4-inch and 3/8-inch circuits were also prepared without an oxygenator in series. An one-time dose of ceftaroline was administered into the circuits, and serial pre- and postoxygenator concentrations were obtained at 5 minutes, 1-, 2-, 3-, 4-, 5-, 6-, and 24-hour time points. Ceftaroline was also maintained in a glass vial, and samples were taken from the vial at the same time periods for control purposes to assess for spontaneous drug degradation. SETTING: A free-standing extracorporeal membrane oxygenation circuit. PATIENTS: None. INTERVENTION: Single dose administration of ceftaroline into closed-loop extracorporeal membrane oxygenation circuits prepared with and without an oxygenator in series with serial preoxygenator, postoxygenator, and reference samples obtained for concentration determination over a 24-hour study period. MEASUREMENTS AND MAIN RESULTS: For the 1/4-inch circuit with an oxygenator, there was 79.8% drug loss preoxygenator and 82.5% drug loss postoxygenator at 24 hours. There was a statistically significant difference (p < 0.01) in the amount of ceftaroline remaining at 24 hours when compared with each prior time point for the 1/4-inch circuit. For the 1/4-inch circuit without an oxygenator, there was no significant drug loss at any study time point. For the 3/8-inch circuit with an oxygenator, there was 76.2% drug loss preoxygenator and 77.6% drug loss postoxygenator at 24 hours. There was a statistically significant difference (p < 0.01) in the amount of ceftaroline remaining at 24 hours when compared with each prior time point for the 3/8-inch circuit. For the 3/8-inch circuit without an oxygenator, there was no significant drug loss at any study time point. The reference ceftaroline concentrations remained relatively constant during the entire study period demonstrating the ceftaroline loss in each size of the extracorporeal membrane oxygenation circuit with or without an oxygenator was not a result of spontaneous drug degradation and primarily the result of the oxygenator. CONCLUSIONS: This ex vivo investigation demonstrated significant ceftaroline loss within an extracorporeal membrane oxygenation circuit with an oxygenator in series with both sizes of the Quadrox-i oxygenator at 24 hours. Therapeutic concentrations of ceftaroline in the setting of extracorporeal membrane oxygenation may not be achieved with current U.S. Food and Drug Administration-recommended doses, and further evaluation is needed before specific drug dosing recommendations can be made for clinical application with extracorporeal membrane oxygenation.


Asunto(s)
Antibacterianos/farmacocinética , Cefalosporinas/farmacocinética , Oxigenación por Membrana Extracorpórea/métodos , Oxigenadores de Membrana/efectos adversos , Diseño de Equipo , Humanos , Ceftarolina
5.
Perfusion ; 33(8): 624-629, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30019619

RESUMEN

BACKGROUND: The objective was to determine the alterations of daptomycin (DAP) in a contemporary neonatal/pediatric (1/4-inch) and adolescent/adult (3/8-inch) extracorporeal membrane oxygenation (ECMO) circuit including the Quadrox-i® oxygenator. METHODS: Quarter-inch and 3/8-inch, simulated, closed-loop, ECMO circuits were prepared with a Quadrox-i pediatric and Quadrox-i adult oxygenator and blood primed. A one-time dose of DAP was administered into the circuit and serial pre- and post-oxygenator concentrations were obtained at 0-5 minutes and 1, 2, 3, 4, 5, 6 and 24-hour time points. DAP was also maintained in a glass vial and samples were taken from the vial at the same time periods for control purposes to assess for spontaneous drug degradation. RESULTS: For both the 1/4-inch and 3/8-inch circuits, there was no significant DAP loss at 24 hours. Additionally, the reference DAP concentrations remained relatively constant during the entire 24-hour study period. CONCLUSION: This ex-vivo investigation demonstrated no significant DAP loss within an ECMO circuit with both sizes of the Quadrox-i oxygenator at 24 hours. Therapeutic concentrations of DAP in the setting of ECMO may be anticipated with current recommended doses, depending on the amount of extracorporeal volume needed for circuit maintenance in comparison to the patient's apparent volume of distribution. Additional studies with a larger sample size are needed to confirm these findings.


Asunto(s)
Daptomicina , Oxigenación por Membrana Extracorpórea , Adolescente , Niño , Preescolar , Daptomicina/química , Daptomicina/farmacocinética , Daptomicina/farmacología , Femenino , Humanos , Lactante , Recién Nacido , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...