1.
J Am Coll Radiol ; 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38969253

RESUMEN

OBJECTIVE: Mammography and MRI screening typically occur in combination or in alternating sequence. We compared multimodality screening performance accounting for the relative timing of mammography and MRI and overlapping follow-up periods. METHODS: We identified 8,260 screening mammograms performed 2005-2017 in the Breast Cancer Surveillance Consortium, paired with screening MRIs within +/- 90 days (combined screening) or 91-270 days (alternating screening). Performance for combined screening [cancer detection rate (CDR) per 1000 examinations and sensitivity] was calculated with one-year follow-up for each modality, and with a single follow-up period treating the two tests as a single test. Alternating screening performance was calculated with one-year follow-up for each modality and also with follow-up ending at the next screen if within one year (truncated follow-up). RESULTS: For 3,810 combined screening pairs, CDR per 1000 screens was 6.8 (95%CI: 4.6-10.0) for mammography and 12.3 (95%CI: 9.3-16.4) for MRI as separate tests compared to 13.1 (95%CI: 10.0-17.3) as a single combined test. Sensitivity of each test was 48.1% (35.0%-61.5%) for mammography and 79.7% (95%CI: 67.7-88.0%) for MRI compared to 96.2% (95%CI: 85.9-99.0%) for combined screening. For 4,450 alternating screening pairs, mammography CDR per 1000 screens changed from 3.6 (95%CI: 2.2-5.9) to zero with truncated follow-up; sensitivity was incalculable (denominator=0). MRI CDR per 1000 screens changed from 12.1 (95%CI 9.3-15.8) to 11.7 (95%CI: 8.9-15.3) with truncated follow-up; sensitivity changed from 75.0% (95%CI 63.8-83.6%) to 86.7% (95%CI 75.5-93.2%). DISCUSSION: Updating auditing approaches to account for combined and alternating screening sequencing and to address outcome attribution issues arising from overlapping follow-up periods can improve the accuracy of multimodality screening performance evaluation.

2.
J Am Coll Radiol ; 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38789066

RESUMEN

With promising artificial intelligence (AI) algorithms receiving FDA clearance, the potential impact of these models on clinical outcomes must be evaluated locally before their integration into routine workflows. Robust validation infrastructures are pivotal to inspecting the accuracy and generalizability of these deep learning algorithms to ensure both patient safety and health equity. Protected health information concerns, intellectual property rights, and diverse requirements of models impede the development of rigorous external validation infrastructures. The authors propose various suggestions for addressing the challenges associated with the development of efficient, customizable, and cost-effective infrastructures for the external validation of AI models at large medical centers and institutions. The authors present comprehensive steps to establish an AI inferencing infrastructure outside clinical systems to examine the local performance of AI algorithms before health practice or systemwide implementation and promote an evidence-based approach for adopting AI models that can enhance radiology workflows and improve patient outcomes.

3.
Radiol Clin North Am ; 62(4): 619-625, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38777538

RESUMEN

Breast cancer risk prediction models based on common clinical risk factors are used to identify women eligible for high-risk screening and prevention. Unfortunately, these models have only modest discriminatory accuracy with disparities in performance in underrepresented race and ethnicity groups. The field of artificial intelligence (AI) and deep learning are rapidly advancing the field of breast cancer risk prediction with the development of mammography-based AI breast cancer risk models. Early studies suggest mammography-based AI risk models may perform better than traditional risk factor-based models with more equitable performance.


Asunto(s)
Inteligencia Artificial , Neoplasias de la Mama , Mamografía , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Medición de Riesgo/métodos , Mamografía/métodos , Mama/diagnóstico por imagen , Factores de Riesgo , Detección Precoz del Cáncer/métodos
4.
JAMA ; 331(22): 1947-1960, 2024 06 11.
Artículo en Inglés | MEDLINE | ID: mdl-38687505

RESUMEN

Importance: The effects of breast cancer incidence changes and advances in screening and treatment on outcomes of different screening strategies are not well known. Objective: To estimate outcomes of various mammography screening strategies. Design, Setting, and Population: Comparison of outcomes using 6 Cancer Intervention and Surveillance Modeling Network (CISNET) models and national data on breast cancer incidence, mammography performance, treatment effects, and other-cause mortality in US women without previous cancer diagnoses. Exposures: Thirty-six screening strategies with varying start ages (40, 45, 50 years) and stop ages (74, 79 years) with digital mammography or digital breast tomosynthesis (DBT) annually, biennially, or a combination of intervals. Strategies were evaluated for all women and for Black women, assuming 100% screening adherence and "real-world" treatment. Main Outcomes and Measures: Estimated lifetime benefits (breast cancer deaths averted, percent reduction in breast cancer mortality, life-years gained), harms (false-positive recalls, benign biopsies, overdiagnosis), and number of mammograms per 1000 women. Results: Biennial screening with DBT starting at age 40, 45, or 50 years until age 74 years averted a median of 8.2, 7.5, or 6.7 breast cancer deaths per 1000 women screened, respectively, vs no screening. Biennial DBT screening at age 40 to 74 years (vs no screening) was associated with a 30.0% breast cancer mortality reduction, 1376 false-positive recalls, and 14 overdiagnosed cases per 1000 women screened. Digital mammography screening benefits were similar to those for DBT but had more false-positive recalls. Annual screening increased benefits but resulted in more false-positive recalls and overdiagnosed cases. Benefit-to-harm ratios of continuing screening until age 79 years were similar or superior to stopping at age 74. In all strategies, women with higher-than-average breast cancer risk, higher breast density, and lower comorbidity level experienced greater screening benefits than other groups. Annual screening of Black women from age 40 to 49 years with biennial screening thereafter reduced breast cancer mortality disparities while maintaining similar benefit-to-harm trade-offs as for all women. Conclusions: This modeling analysis suggests that biennial mammography screening starting at age 40 years reduces breast cancer mortality and increases life-years gained per mammogram. More intensive screening for women with greater risk of breast cancer diagnosis or death can maintain similar benefit-to-harm trade-offs and reduce mortality disparities.


Asunto(s)
Neoplasias de la Mama , Detección Precoz del Cáncer , Mamografía , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Factores de Edad , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/mortalidad , Neoplasias de la Mama/diagnóstico por imagen , Técnicas de Apoyo para la Decisión , Reacciones Falso Positivas , Incidencia , Tamizaje Masivo , Uso Excesivo de los Servicios de Salud , Guías de Práctica Clínica como Asunto , Estados Unidos/epidemiología , Modelos Estadísticos
5.
J Natl Cancer Inst ; 116(6): 929-937, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38466940

RESUMEN

BACKGROUND: Annual surveillance mammography is recommended for women with a personal history of breast cancer. Risk prediction models that estimate mammography failures such as interval second breast cancers could help to tailor surveillance imaging regimens to women's individual risk profiles. METHODS: In a cohort of women with a history of breast cancer receiving surveillance mammography in the Breast Cancer Surveillance Consortium in 1996-2019, we used Least Absolute Shrinkage and Selection Operator (LASSO)-penalized regression to estimate the probability of an interval second cancer (invasive cancer or ductal carcinoma in situ) in the 1 year after a negative surveillance mammogram. Based on predicted risks from this one-year risk model, we generated cumulative risks of an interval second cancer for the five-year period after each mammogram. Model performance was evaluated using cross-validation in the overall cohort and within race and ethnicity strata. RESULTS: In 173 290 surveillance mammograms, we observed 496 interval cancers. One-year risk models were well-calibrated (expected/observed ratio = 1.00) with good accuracy (area under the receiver operating characteristic curve = 0.64). Model performance was similar across race and ethnicity groups. The median five-year cumulative risk was 1.20% (interquartile range 0.93%-1.63%). Median five-year risks were highest in women who were under age 40 or pre- or perimenopausal at diagnosis and those with estrogen receptor-negative primary breast cancers. CONCLUSIONS: Our risk model identified women at high risk of interval second breast cancers who may benefit from additional surveillance imaging modalities. Risk models should be evaluated to determine if risk-guided supplemental surveillance imaging improves early detection and decreases surveillance failures.


Asunto(s)
Neoplasias de la Mama , Mamografía , Neoplasias Primarias Secundarias , Humanos , Femenino , Neoplasias de la Mama/epidemiología , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico , Persona de Mediana Edad , Mamografía/estadística & datos numéricos , Anciano , Neoplasias Primarias Secundarias/epidemiología , Medición de Riesgo , Adulto , Detección Precoz del Cáncer , Factores de Riesgo
7.
J Am Coll Radiol ; 21(2): 319-328, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37949155

RESUMEN

PURPOSE: To summarize the literature regarding the performance of mammography-image based artificial intelligence (AI) algorithms, with and without additional clinical data, for future breast cancer risk prediction. MATERIALS AND METHODS: A systematic literature review was performed using six databases (medRixiv, bioRxiv, Embase, Engineer Village, IEEE Xplore, and PubMed) from 2012 through September 30, 2022. Studies were included if they used real-world screening mammography examinations to validate AI algorithms for future risk prediction based on images alone or in combination with clinical risk factors. The quality of studies was assessed, and predictive accuracy was recorded as the area under the receiver operating characteristic curve (AUC). RESULTS: Sixteen studies met inclusion and exclusion criteria, of which 14 studies provided AUC values. The median AUC performance of AI image-only models was 0.72 (range 0.62-0.90) compared with 0.61 for breast density or clinical risk factor-based tools (range 0.54-0.69). Of the seven studies that compared AI image-only performance directly to combined image + clinical risk factor performance, six demonstrated no significant improvement, and one study demonstrated increased improvement. CONCLUSIONS: Early efforts for predicting future breast cancer risk based on mammography images alone demonstrate comparable or better accuracy to traditional risk tools with little or no improvement when adding clinical risk factor data. Transitioning from clinical risk factor-based to AI image-based risk models may lead to more accurate, personalized risk-based screening approaches.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Inteligencia Artificial , Detección Precoz del Cáncer/métodos , Mama/diagnóstico por imagen , Estudios Retrospectivos
8.
Radiology ; 308(2): e230576, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37581498

RESUMEN

Background Contrast-enhanced mammography (CEM) and abbreviated breast MRI (ABMRI) are emerging alternatives to standard MRI for supplemental breast cancer screening. Purpose To compare the diagnostic performance of CEM, ABMRI, and standard MRI. Materials and Methods This single-institution, prospective, blinded reader study included female participants referred for breast MRI from January 2018 to June 2021. CEM was performed within 14 days of standard MRI; ABMRI was produced from standard MRI images. Two readers independently interpreted each CEM and ABMRI after a washout period. Examination-level performance metrics calculated were recall rate, cancer detection, and false-positive biopsy recommendation rates per 1000 examinations and sensitivity, specificity, and positive predictive value of biopsy recommendation. Bootstrap and permutation tests were used to calculate 95% CIs and compare modalities. Results Evaluated were 492 paired CEM and ABMRI interpretations from 246 participants (median age, 51 years; IQR, 43-61 years). On 49 MRI scans with lesions recommended for biopsy, nine lesions showed malignant pathology. No differences in ABMRI and standard MRI performance were identified. Compared with standard MRI, CEM demonstrated significantly lower recall rate (14.0% vs 22.8%; difference, -8.7%; 95% CI: -14.0, -3.5), lower false-positive biopsy recommendation rate per 1000 examinations (65.0 vs 162.6; difference, -97.6; 95% CI: -146.3, -50.8), and higher specificity (87.8% vs 80.2%; difference, 7.6%; 95% CI: 2.3, 13.1). Compared with standard MRI, CEM had significantly lower cancer detection rate (22.4 vs 36.6; difference, -14.2; 95% CI: -28.5, -2.0) and sensitivity (61.1% vs 100%; difference, -38.9%; 95% CI: -66.7, -12.5). The performance differences between CEM and ABMRI were similar to those observed between CEM and standard MRI. Conclusion ABMRI had comparable performance to standard MRI and may support more efficient MRI screening. CEM had lower recall and higher specificity compared with standard MRI or ABMRI, offset by lower cancer detection rate and sensitivity compared with standard MRI. These trade-offs warrant further consideration of patient population characteristics before widespread screening with CEM. Clinical trial registration no. NCT03517813 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Chang in this issue.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Persona de Mediana Edad , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Estudios Prospectivos , Sensibilidad y Especificidad , Detección Precoz del Cáncer/métodos , Mamografía/métodos , Imagen por Resonancia Magnética/métodos
9.
Korean J Radiol ; 24(8): 729-738, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37500574

RESUMEN

OBJECTIVE: When multiple surveillance mammograms are performed within an annual interval, the current guidance for one-year follow-up to determine breast cancer status results in shared follow-up periods in which a single breast cancer diagnosis can be attributed to multiple preceding examinations, posing a challenge for standardized performance assessment. We assessed the impact of using follow-up periods that eliminate the artifactual inflation of second breast cancer diagnoses. MATERIALS AND METHODS: We evaluated surveillance mammograms from 2007-2016 in women with treated breast cancer linked with tumor registry and pathology outcomes. Second breast cancers included ductal carcinoma in situ or invasive breast cancer diagnosed during one-year follow-up. The cancer detection rate, interval cancer rate, sensitivity, and specificity were compared using different follow-up periods: standard one-year follow-up per the American College of Radiology versus follow-up that was shortened at the next surveillance mammogram if less than one year (truncated follow-up). Performance measures were calculated overall and by indication (screening, evaluation for breast problem, and short interval follow-up). RESULTS: Of 117971 surveillance mammograms, 20% (n = 23533) were followed by another surveillance mammogram within one year. Standard follow-up identified 1597 mammograms that were associated with second breast cancers. With truncated follow-up, the breast cancer status of 179 mammograms (11.2%) was revised, resulting in 1418 mammograms associated with unique second breast cancers. The interval cancer rate decreased with truncated versus standard follow-up (3.6 versus 4.9 per 1000 mammograms, respectively), with a difference (95% confidence interval [CI]) of -1.3 (-1.6, -1.1). The overall sensitivity increased to 70.4% from 63.7%, for the truncated versus standard follow-up, with a difference (95% CI) of 6.6% (5.6%, 7.7%). The specificity remained stable at 98.1%. CONCLUSION: Truncated follow-up, if less than one year to the next surveillance mammogram, enabled second breast cancers to be associated with a single preceding mammogram and resulted in more accurate estimates of diagnostic performance for national benchmarks.


Asunto(s)
Neoplasias de la Mama , Carcinoma Intraductal no Infiltrante , Femenino , Humanos , Neoplasias de la Mama/patología , Mamografía , Carcinoma Intraductal no Infiltrante/patología , Sistema de Registros , Tamizaje Masivo/métodos
10.
Cancer ; 129(16): 2456-2468, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37303202

RESUMEN

BACKGROUND: There are no consensus guidelines for supplemental breast cancer screening with whole-breast ultrasound. However, criteria for women at high risk of mammography screening failures (interval invasive cancer or advanced cancer) have been identified. Mammography screening failure risk was evaluated among women undergoing supplemental ultrasound screening in clinical practice compared with women undergoing mammography alone. METHODS: A total of 38,166 screening ultrasounds and 825,360 screening mammograms without supplemental screening were identified during 2014-2020 within three Breast Cancer Surveillance Consortium (BCSC) registries. Risk of interval invasive cancer and advanced cancer were determined using BCSC prediction models. High interval invasive breast cancer risk was defined as heterogeneously dense breasts and BCSC 5-year breast cancer risk ≥2.5% or extremely dense breasts and BCSC 5-year breast cancer risk ≥1.67%. Intermediate/high advanced cancer risk was defined as BCSC 6-year advanced breast cancer risk ≥0.38%. RESULTS: A total of 95.3% of 38,166 ultrasounds were among women with heterogeneously or extremely dense breasts, compared with 41.8% of 825,360 screening mammograms without supplemental screening (p < .0001). Among women with dense breasts, high interval invasive breast cancer risk was prevalent in 23.7% of screening ultrasounds compared with 18.5% of screening mammograms without supplemental imaging (adjusted odds ratio, 1.35; 95% CI, 1.30-1.39); intermediate/high advanced cancer risk was prevalent in 32.0% of screening ultrasounds versus 30.5% of screening mammograms without supplemental screening (adjusted odds ratio, 0.91; 95% CI, 0.89-0.94). CONCLUSIONS: Ultrasound screening was highly targeted to women with dense breasts, but only a modest proportion were at high mammography screening failure risk. A clinically significant proportion of women undergoing mammography screening alone were at high mammography screening failure risk.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/epidemiología , Detección Precoz del Cáncer/métodos , Mamografía/métodos , Factores de Riesgo , Ultrasonografía Mamaria , Tamizaje Masivo/métodos , Densidad de la Mama
11.
Radiology ; 307(5): e223142, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37249433

RESUMEN

Background Prior cross-sectional studies have observed that breast cancer screening with digital breast tomosynthesis (DBT) has a lower recall rate and higher cancer detection rate compared with digital mammography (DM). Purpose To evaluate breast cancer screening outcomes with DBT versus DM on successive screening rounds. Materials and Methods In this retrospective cohort study, data from 58 breast imaging facilities in the Breast Cancer Surveillance Consortium were collected. Analysis included women aged 40-79 years undergoing DBT or DM screening from 2011 to 2020. Absolute differences in screening outcomes by modality and screening round were estimated during the study period by using generalized estimating equations with marginal standardization to adjust for differences in women's risk characteristics across modality and round. Results A total of 523 485 DBT examinations (mean age of women, 58.7 years ± 9.7 [SD]) and 1 008 123 DM examinations (mean age, 58.4 years ± 9.8) among 504 863 women were evaluated. DBT and DM recall rates decreased with successive screening round, but absolute recall rates in each round were significantly lower with DBT versus DM (round 1 difference, -3.3% [95% CI: -4.6, -2.1] [P < .001]; round 2 difference, -1.8% [95% CI: -2.9, -0.7] [P = .003]; round 3 or above difference, -1.2% [95% CI: -2.4, -0.1] [P = .03]). DBT had significantly higher cancer detection (difference, 0.6 per 1000 examinations [95% CI: 0.2, 1.1]; P = .009) compared with DM only for round 3 and above. There were no significant differences in interval cancer rate (round 1 difference, 0.00 per 1000 examinations [95% CI: -0.24, 0.30] [P = .96]; round 2 or above difference, 0.04 [95% CI: -0.19, 0.31] [P = .76]) or total advanced cancer rate (round 1 difference, 0.00 per 1000 examinations [95% CI: -0.15, 0.19] [P = .94]; round 2 or above difference, -0.06 [95% CI: -0.18, 0.11] [P = .43]). Conclusion DBT had lower recall rates and could help detect more cancers than DM across three screening rounds, with no difference in interval or advanced cancer rates. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Skaane in this issue.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Persona de Mediana Edad , Neoplasias de la Mama/epidemiología , Densidad de la Mama , Estudios Retrospectivos , Estudios Transversales , Detección Precoz del Cáncer/métodos , Mamografía/métodos , Tamizaje Masivo/métodos
12.
Cancer ; 129(8): 1173-1182, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36789739

RESUMEN

BACKGROUND: In women with previously treated breast cancer, occurrence and timing of second breast cancers have implications for surveillance. The authors examined the timing of second breast cancers by primary cancer estrogen receptor (ER) status in the Breast Cancer Surveillance Consortium. METHODS: Women who were diagnosed with American Joint Commission on Cancer stage I-III breast cancer were identified within six Breast Cancer Surveillance Consortium registries from 2000 to 2017. Characteristics collected at primary breast cancer diagnosis included demographics, ER status, and treatment. Second breast cancer events included subsequent ipsilateral or contralateral breast cancers diagnosed >6 months after primary diagnosis. The authors examined cumulative incidence and second breast cancer rates by primary cancer ER status during 1-5 versus 6-10 years after diagnosis. RESULTS: At 10 years, the cumulative second breast cancer incidence was 11.8% (95% confidence interval [CI], 10.7%-13.1%) for women with ER-negative disease and 7.5% (95% CI, 7.0%-8.0%) for those with ER-positive disease. Women with ER-negative cancer had higher second breast cancer rates than those with ER-positive cancer during the first 5 years of follow-up (16.0 per 1000 person-years [PY]; 95% CI, 14.2-17.9 per 1000 PY; vs. 7.8 per 1000 PY; 95% CI, 7.3-8.4 per 1000 PY, respectively). After 5 years, second breast cancer rates were similar for women with ER-negative versus ER-positive breast cancer (12.1 per 1000 PY; 95% CI, 9.9-14.7; vs. 9.3 per 1000 PY; 95% CI, 8.4-10.3 per 1000 PY, respectively). CONCLUSIONS: ER-negative primary breast cancers are associated with a higher risk of second breast cancers than ER-positive cancers during the first 5 years after diagnosis. Further study is needed to examine the potential benefit of more intensive surveillance targeting these women in the early postdiagnosis period.


Asunto(s)
Neoplasias de la Mama , Neoplasias Primarias Secundarias , Femenino , Humanos , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/epidemiología , Neoplasias de la Mama/terapia , Receptores de Estrógenos , Factores de Riesgo , Neoplasias Primarias Secundarias/diagnóstico , Neoplasias Primarias Secundarias/epidemiología , Neoplasias Primarias Secundarias/terapia , Mama
13.
Cancer Epidemiol Biomarkers Prev ; 32(4): 561-571, 2023 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-36697364

RESUMEN

BACKGROUND: Machine learning (ML) approaches facilitate risk prediction model development using high-dimensional predictors and higher-order interactions at the cost of model interpretability and transparency. We compared the relative predictive performance of statistical and ML models to guide modeling strategy selection for surveillance mammography outcomes in women with a personal history of breast cancer (PHBC). METHODS: We cross-validated seven risk prediction models for two surveillance outcomes, failure (breast cancer within 12 months of a negative surveillance mammogram) and benefit (surveillance-detected breast cancer). We included 9,447 mammograms (495 failures, 1,414 benefits, and 7,538 nonevents) from years 1996 to 2017 using a 1:4 matched case-control samples of women with PHBC in the Breast Cancer Surveillance Consortium. We assessed model performance of conventional regression, regularized regressions (LASSO and elastic-net), and ML methods (random forests and gradient boosting machines) by evaluating their calibration and, among well-calibrated models, comparing the area under the receiver operating characteristic curve (AUC) and 95% confidence intervals (CI). RESULTS: LASSO and elastic-net consistently provided well-calibrated predicted risks for surveillance failure and benefit. The AUCs of LASSO and elastic-net were both 0.63 (95% CI, 0.60-0.66) for surveillance failure and 0.66 (95% CI, 0.64-0.68) for surveillance benefit, the highest among well-calibrated models. CONCLUSIONS: For predicting breast cancer surveillance mammography outcomes, regularized regression outperformed other modeling approaches and balanced the trade-off between model flexibility and interpretability. IMPACT: Regularized regression may be preferred for developing risk prediction models in other contexts with rare outcomes, similar training sample sizes, and low-dimensional features.


Asunto(s)
Neoplasias de la Mama , Supervivientes de Cáncer , Femenino , Humanos , Mama , Mamografía , Aprendizaje Automático
14.
J Am Coll Radiol ; 19(10): 1098-1110, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35970474

RESUMEN

BACKGROUND: Artificial intelligence (AI) may improve cancer detection and risk prediction during mammography screening, but radiologists' preferences regarding its characteristics and implementation are unknown. PURPOSE: To quantify how different attributes of AI-based cancer detection and risk prediction tools affect radiologists' intentions to use AI during screening mammography interpretation. MATERIALS AND METHODS: Through qualitative interviews with radiologists, we identified five primary attributes for AI-based breast cancer detection and four for breast cancer risk prediction. We developed a discrete choice experiment based on these attributes and invited 150 US-based radiologists to participate. Each respondent made eight choices for each tool between three alternatives: two hypothetical AI-based tools versus screening without AI. We analyzed samplewide preferences using random parameters logit models and identified subgroups with latent class models. RESULTS: Respondents (n = 66; 44% response rate) were from six diverse practice settings across eight states. Radiologists were more interested in AI for cancer detection when sensitivity and specificity were balanced (94% sensitivity with <25% of examinations marked) and AI markup appeared at the end of the hanging protocol after radiologists complete their independent review. For AI-based risk prediction, radiologists preferred AI models using both mammography images and clinical data. Overall, 46% to 60% intended to adopt any of the AI tools presented in the study; 26% to 33% approached AI enthusiastically but were deterred if the features did not align with their preferences. CONCLUSION: Although most radiologists want to use AI-based decision support, short-term uptake may be maximized by implementing tools that meet the preferences of dissuadable users.


Asunto(s)
Neoplasias de la Mama , Mamografía , Inteligencia Artificial , Neoplasias de la Mama/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Femenino , Humanos , Mamografía/métodos , Tamizaje Masivo , Radiólogos
15.
Ann Surg Oncol ; 29(10): 6350-6358, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35802213

RESUMEN

BACKGROUND: Atypical lobular hyperplasia (ALH) and classic lobular carcinoma in situ encompass a spectrum of proliferative lesions known as lobular neoplasia (LN). When imaging-concordant and found in isolation on core needle biopsy (CNB), LN infrequently upgrades to carcinoma on surgical excision, and routine excision is not indicated. Upgrade rates in the setting of synchronous carcinoma are not well studied. PATIENTS AND METHODS: Patients with radiology-pathology concordant synchronous LN and separately biopsied ipsilateral (n = 35) or contralateral (n = 15) carcinoma who underwent excision between 2010 and 2021 were retrospectively identified. Frequency of upgrade, to either invasive or in situ carcinoma, was quantified, and factors associated with upgrade were assessed using Fisher's exact test. RESULTS: The median age was 55 (range 33-74) years. The upgrade rate of LN was 6% and not significantly different between ipsilateral (2.9%) and contralateral (13.3%) carcinoma (p = 0.15). All upgraded LN lesions were ALH on CNB and detected as non-mass enhancement on magnetic resonance imaging (MRI). No additional disease was demonstrated after excision at the site of the original LN CNB in 22.9% (8 out of 35) of ipsilateral and 13.3% (2 out of 15) of contralateral patients. Upgrade was not associated with family history, menopausal status, imaging modality used to detect LN, or extent of LN on CNB (p > 0.05). CONCLUSIONS: Our results demonstrate a low upgrade rate (6%) in our study cohort of LN with synchronous ipsilateral or contralateral carcinoma, which suggests that not all LN mandates excision with synchronous carcinoma. Larger, multi-institution studies are needed to validate these findings.


Asunto(s)
Carcinoma de Mama in situ , Neoplasias de la Mama , Carcinoma in Situ , Carcinoma Lobular , Lesiones Precancerosas , Adulto , Anciano , Biopsia con Aguja Gruesa , Carcinoma de Mama in situ/patología , Carcinoma de Mama in situ/cirugía , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Carcinoma in Situ/patología , Carcinoma Lobular/patología , Femenino , Humanos , Hiperplasia/cirugía , Persona de Mediana Edad , Lesiones Precancerosas/patología , Estudios Retrospectivos
19.
J Natl Compr Canc Netw ; 20(4): 379-386.e9, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35390766

RESUMEN

BACKGROUND: Annual mammography is recommended for breast cancer survivors; however, population-level temporal trends in surveillance mammography participation have not been described. Our objective was to characterize trends in annual surveillance mammography participation among women with a personal history of breast cancer over a 13-year period. METHODS: We examined annual surveillance mammography participation from 2004 to 2016 in a nationwide sample of commercially insured women with prior breast cancer. Rates were stratified by age group (40-49 vs 50-64 years), visit with a surgical/oncology specialist or primary care provider within the prior year, and sociodemographic characteristics. Joinpoint models were used to estimate annual percentage changes (APCs) in participation during the study period. RESULTS: Among 141,672 women, mammography rates declined from 74.1% in 2004 to 67.1% in 2016. Rates were stable from 2004 to 2009 (APC, 0.1%; 95% CI, -0.5% to 0.8%) but declined 1.5% annually from 2009 to 2016 (95% CI, -1.9% to -1.1%). For women aged 40 to 49 years, rates declined 2.8% annually (95% CI, -3.4% to -2.1%) after 2009 versus 1.4% annually in women aged 50 to 64 years (95% CI, -1.9% to -1.0%). Similar trends were observed in women who had seen a surgeon/oncologist (APC, -1.7%; 95% CI, -2.1% to -1.4%) or a primary care provider (APC, -1.6%; 95% CI, -2.1% to -1.2%) in the prior year. CONCLUSIONS: Surveillance mammography participation among breast cancer survivors declined from 2009 to 2016, most notably among women aged 40 to 49 years. These findings highlight a need for focused efforts to improve adherence to surveillance and prevent delays in detection of breast cancer recurrence and second cancers.


Asunto(s)
Neoplasias de la Mama , Supervivientes de Cáncer , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/epidemiología , Femenino , Humanos , Mamografía , Recurrencia Local de Neoplasia , Sobrevivientes
20.
Surg Pathol Clin ; 15(1): 1-13, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35236626

RESUMEN

Errors in anatomic pathology can result in patients receiving inappropriate treatment and poor patient outcomes. Policies and procedures are necessary to decrease error and improve diagnostic concordance. Breast pathology may be more prone to diagnostic errors than other surgical pathology subspecialties due to inherit borderline diagnostic categories such as atypical ductal hyperplasia and low-grade ductal carcinoma in situ. Mandatory secondary review of internal and outside referral cases before treatment is effective in reducing diagnostic errors and improving concordance. Assessment of error through amendment/addendum tracking, implementing an incident reporting system, and multidisciplinary tumor boards can establish procedures to prevent future error.


Asunto(s)
Neoplasias de la Mama , Carcinoma Ductal de Mama , Carcinoma Intraductal no Infiltrante , Patología Quirúrgica , Mama/patología , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Carcinoma Ductal de Mama/patología , Carcinoma Intraductal no Infiltrante/diagnóstico , Carcinoma Intraductal no Infiltrante/patología , Femenino , Humanos