Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Orthop Traumatol ; 25(1): 21, 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38637406

RESUMEN

BACKGROUND: Treating tibial non-unions efficiently presents a challenge for orthopaedic trauma surgeons. The established gold standard involves implanting autologous bone graft with adequate fixation, but the addition of biologicals according to the so-called diamond concept has become increasingly popular in the treatment of non-unions. Previous studies have indicated that polytherapy, which involves implanting mesenchymal stem cells, bioactive factors and osteoconductive scaffolds, can improve bone healing. This study aims to evaluate the efficacy of polytherapy compared with monotherapy in treating tibial non-unions of varying severity. MATERIALS AND METHODS: Data from consecutive tibial non-unions treated between November 2014 and July 2023 were retrospectively analysed. The Non Union Scoring System (NUSS) score before non-union surgery, and the Radiographic Union Score for Tibial fractures (RUST), scored at 1, 3, 6, 9, 12 and 18 months post-surgery, were recorded. Initially, a comparison was made between the polytherapy and monotherapy groups. Subsequently, patients receiving additional surgical non-union treatment were documented, and the frequency of these treatments was tallied for a subsequent per-treatment analysis. RESULTS: A total of 34 patients were included and divided into a polytherapy group (n = 15) and a monotherapy group (n = 19). The polytherapy group demonstrated a higher NUSS score (44 (39, 52) versus 32 (29, 43), P = 0.019, z = -2.347) and a tendency towards a higher success rate (93% versus 68%, P = 0.104) compared with the monotherapy group. For the per-treatment analysis, 44 treatments were divided into the polytherapy per-treatment group (n = 20) and the monotherapy per-treatment group (n = 24). The polytherapy per-treatment group exhibited a higher NUSS score (48 (43, 60) versus 38 (30, 50), P = 0.030, z = -2.173) and a higher success rate (95% versus 58%, P = 0.006) than the monotherapy per-treatment group. Within the monotherapy per-treatment group, the NUSS score displayed excellent predictive performance (AUC = 0.9143). Setting the threshold value at 48, the sensitivity and specificity were 100.0% and 70.0%, respectively. CONCLUSIONS: Polytherapy is more effective than monotherapy for severe tibial non-unions, offering a higher success ratio. The NUSS score supports decision-making in treating tibial non-unions. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Fracturas no Consolidadas , Fracturas de la Tibia , Humanos , Estudios Retrospectivos , Fracturas no Consolidadas/terapia , Curación de Fractura , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Trasplante Óseo , Resultado del Tratamiento
2.
Bone ; 181: 117021, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38253189

RESUMEN

PURPOSE: This review aims to provide an overview of the multiple functions of neutrophils, with the recognition of the inflammatory (N1) and regenerative (N2) phenotypes, in relation to fracture healing. METHODS: A literature search was performed using the PubMed database. The quality of the articles was evaluated using critical appraisal checklists. RESULTS: Thirty one studies were included in this review. These studies consistently support that neutrophils exert both beneficial and detrimental effects on bone regeneration, influenced by Tumor Necrosis Factor-α (TNF-α), Interleukin 8 (IL-8), mast cells, and macrophages. The N2 phenotype has recently emerged as one promoter of bone healing. The N1 phenotype has progressively been connected with inflammatory neutrophils during fracture healing. CONCLUSIONS: This review has pinpointed various aspects and mechanisms of neutrophil influence on bone healing. The recognition of N1 and N2 neutrophil phenotypes potentially shed new light on the dynamic shifts taking place within the Fracture Hematoma (FH).


Asunto(s)
Fracturas Óseas , Neutrófilos , Humanos , Neutrófilos/patología , Regeneración Ósea , Curación de Fractura , Fracturas Óseas/patología , Fenotipo
3.
Nanoscale ; 16(6): 2974-2982, 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38258372

RESUMEN

Wearable bioelectronic devices, which circumvent issues related to the large size and high cost of clinical equipment, have emerged as powerful tools for the auxiliary diagnosis and long-term monitoring of chronic psychiatric diseases. Current devices often integrate multiple intricate and expensive devices to ensure accurate diagnosis. However, their high cost and complexity hinder widespread clinical application and long-term user compliance. Herein, we developed an ultralow-cost poly(vinylidene fluoride)/zinc oxide nanofiber film-based piezoelectric sensor in a thermal compression bonding process. Our piezoelectric sensor exhibits remarkable sensitivity (13.4 mV N-1), rapid response (8 ms), and exceptional stability over 2000 compression/release cycles, all at a negligibly low fabrication cost. We demonstrate that pulse wave, blink, and speech signals can be acquired by the sensor, proposing a single biomechanical modality to monitor multiple physiological traits associated with bipolar disorder. This ultralow-cost and mass-producible piezoelectric sensor paves the way for extensive long-term monitoring and immediate feedback for bipolar disorder management.


Asunto(s)
Trastornos Mentales , Nanofibras , Dispositivos Electrónicos Vestibles , Humanos , Presión
4.
ACS Sens ; 8(7): 2691-2701, 2023 07 28.
Artículo en Inglés | MEDLINE | ID: mdl-37262351

RESUMEN

Contact lens sensors provide a noninvasive approach for intraocular pressure (IOP) monitoring in patients with glaucoma. Accurate measurement of this imperceptible pressure variation requires highly sensitive sensors in the absence of simultaneously amplifying IOP signal and blinking-induced noise. However, current noise-reduction methods rely on external filter circuits, which thicken contact lenses and reduce signal quality. Here, we introduce a contact lens strain sensor with an anti-jamming ability by utilizing a self-lubricating layer to reduce the coefficient of friction (COF) to remove the interference from the tangential force. The sensor achieves exceptionally high sensitivity due to the strain concentration layout and the confined occurrence of sympatric microcracks. The animal tests prove our lens can accurately detect IOP safely and reliably.


Asunto(s)
Lentes de Contacto , Glaucoma , Animales , Presión Intraocular , Tonometría Ocular/métodos , Glaucoma/diagnóstico
5.
ACS Nano ; 17(3): 2134-2147, 2023 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-36688948

RESUMEN

A tactile sensor needs to perceive static pressures and dynamic forces in real-time with high accuracy for early diagnosis of diseases and development of intelligent medical prosthetics. However, biomechanical and external mechanical signals are always aliased (including variable physiological and pathological events and motion artifacts), bringing great challenges to precise identification of the signals of interest (SOI). Although the existing signal segmentation methods can extract SOI and remove artifacts by blind source separation and/or additional filters, they may restrict the recognizable patterns of the device, and even cause signal distortion. Herein, an in-memory tactile sensor (IMT) with a dynamically adjustable steep-slope region (SSR) and nanocavity-induced nonvolatility (retention time >1000 s) is proposed on the basis of a machano-gated transistor, which directly transduces the tactile stimuli to various dope states of the channel. The programmable SSR endows the sensor with a critical window of responsiveness, realizing the perception of signals on demand. Owing to the nonvolatility of the sensor, the mapping of mechanical cues with high spatiotemporal accuracy and associative learning between two physical inputs are realized, contributing to the accurate assessment of the tissue health status and ultralow-power (about 25.1 µW) identification of an occasionally occurring tremor.


Asunto(s)
Artefactos , Percepción del Tiempo , Tacto/fisiología , Presión , Movimiento (Física)
6.
ACS Omega ; 6(46): 31177-31183, 2021 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-34841160

RESUMEN

The energy absorption and toughening effect of cartilage could effectively protect bone from damage, and the enhancement mechanisms of cartilage on deformation resistance or strength need to be revealed. Using a self-developed in situ bending tester integrated with an optical microscope, in situ bending of the composite bone structure consisting of the cartilage layer and cortical and cancellous layers was carried out, accompanied by simultaneously obtained continuous morphological changes in diverse deformation layers. Although the bending resistance of pure cartilage layer was only 0.3 N, the significant enhancements of bone strength and ductility induced by the cartilage layer were experimentally revealed, as the peak loads and ultimate bending deflections of the composite structure increased by 1.49- to 2.14-fold and 1.43- to 2.12-fold, respectively. The scanning electron microscopy images of the composite bone structure at various locations with disparate stress conditions exhibited significant difference in crack sizes and degrees of tearing damage. The cartilage layer was verified to induce a layered tearing dimple feature to inhibit the crack propagation and further enhance the deformation resistance. The frequency shift comparison between the Raman spectroscopies of various microregions also indirectly verified the inhibition effect of the cartilage layer on the stress increment in the cortical layer.

7.
Mater Sci Eng C Mater Biol Appl ; 104: 109842, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31500042

RESUMEN

Hydroxyapatite (HA) ceramics are well known for their biocompatibility, bioactivity, and osteoconductive nature. However, limited hierarchical structure and lack of ease in modularity hinder the widespread application of conventional HA ceramics. By using three-dimensional printing (3DP) techniques with multiple materials, including HA, complex biological and mechanical architecture of natural organisms can be achieved through biomimetics. In this study, we designed an osteoid, biomimetic, hierarchical, porous HA ceramic 3D printed scaffold (3DPs). Further incorporation of a covalent, modular, controlled release system (CMR), based on Watson-Crick's complementary oligonucleotides, and was added to carry a bone morphogenetic protein-2 (BMP2) peptide. The choice of a HA biomimetic scaffold housing BMP2 protein fragments was selected to successfully promote osteogenesis both in vitro and in vivo. Scanning electron microscopy, micro-computed tomography analysis and computer fluid dynamics simulations of the 3DPs showed a uniform biomimetic hierarchical structure and an effective interior permeability. Active molecules were found bound with high stability and modular to the scaffold surface via the CMR system. After 7 days of incubation under physiological conditions, approximately 90% of active factors remained bound. Compared to control groups, the 3DPs-CMR-BMP2 group significantly enhanced cell proliferation and adhesion. Moreover, the 3DPs-CMR-BMP2 group exhibited more extensive and sustained osteogenic effects through upregulated expression of osteogenic factors and enhanced calcium deposition, as compared to study and control groups. Furthermore, ectopic osteogenesis and a critical calvarial defect model confirmed that the 3DPs-CMR-BMP2 group significantly promoted in vivo bone healing versus control. Thus, our results showed that biomimetic hierarchical 3DPs with a CMR system successfully promote cell proliferation, adhesion, differentiation and osteogenesis, on a continuous cycle. The biomimetic hierarchical 3DPs with a CMR system offers a promising multi-functional, bone substitute material for treatment of patients with bone defects.


Asunto(s)
Biomimética , Sistemas de Liberación de Medicamentos , Osteogénesis , Impresión Tridimensional , Andamios del Tejido/química , Fosfatasa Alcalina/metabolismo , Animales , Adhesión Celular , Proliferación Celular , Supervivencia Celular , Cerámica/química , Durapatita/química , Fluorescencia , Regulación de la Expresión Génica , Hidrodinámica , Masculino , Minerales/metabolismo , Oligonucleótidos/química , Osteogénesis/genética , Permeabilidad , Porosidad , Ratas Sprague-Dawley , Microtomografía por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...