Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biosens Bioelectron ; 263: 116622, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-39096762

RESUMEN

Accurate on-site detection of nitrite in complex matrices remains a significant challenge. Herin, we construct a self-ratio optical bimodal portable kit via co-assembling NaErF4:0.5%Tm@NaYF4@NaYbF4:0.5%Tm@NaYF4 (Er:Tm@Yb:Tm) and nitrogen-doped carbon platinum nanomaterials (Pt/CN) in sodium alginate (SA) hydrogel. Pt/CN nanomaterials are synthesized by high-temperature sintering using a zinc-based zeolite imidazolium framework as a sacrificial template. The Pt/CN nanozyme possesses excellent oxidase-like activity to produce the oxidation state 3,3',5,5'-tetramethylbenzidine (oxTMB). Nitrite mediates diazotization of oxTMB to trigger the change of absorption signals, accompanying the ratio fluorescence response of the Er:Tm@Yb:Tm. Crucially, Er:Tm@Yb:Tm and Pt/CN are embedded in SA hydrogel to fabricate a portable kit with efficient and sensitive performance. An image processing algorithm is used to analyze the nitrite-induced signal change of the portable hydrogel kit, resulting in detection limits of 0.63 µM. This method has great potential for point-of-care applications due to its reliability, long-term stability, accuracy, sensitivity, and portability.


Asunto(s)
Técnicas Biosensibles , Hidrogeles , Límite de Detección , Nitritos , Teléfono Inteligente , Técnicas Biosensibles/métodos , Nitritos/análisis , Hidrogeles/química , Humanos , Bencidinas/química , Nanoestructuras/química , Platino (Metal)/química
2.
Biosens Bioelectron ; 264: 116624, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39121616

RESUMEN

Fluorescence imaging technology is a versatile and essential tool in the field of biomedical research. To obtain excellent imaging results, the precise labeling of fluorescent probes is an important prerequisite. Nevertheless, the labeling selectivity of most fluorescent probes is not satisfactory, new design concepts are desperately needed. In this context, two isomeric lipid droplets (LDs) fluorescent probes Lipi-Cz-1 and Lipi-Cz-2 have been sophisticatedly developed with TICT and ICT-emitting characteristic, respectively. The more environmentally sensitive TICT-emitting Lipi-Cz-1 exhibits a significantly enhanced labeling selectivity in LDs imaging compared to the ICT-emitting Lipi-Cz-2, sufficiently illustrating the effectiveness of TICT-emitting characteristic in improving labeling selectivity. Additionally, Lipi-Cz-1 displays high photostability and biocompatibility. These advantages enable Lipi-Cz-1 to be finely applied in multimode fluorescence imaging, e.g. time-lapse 3D confocal imaging to monitor changes of the number and size of LDs during starvation, two-photon 3D imaging to compare the variations of LDs in various liver tissues, and STED super-resolution imaging to visualize the nanoscale LDs with the resolution of 65 nm. Overall, these imaging findings validate the effectiveness of the new strategy for improving the labeling selectivity.

3.
Light Sci Appl ; 13(1): 180, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39090112

RESUMEN

Chiral assemblies have become one of the most active research areas due to their versatility, playing an increasingly important role in bio-detection, imaging and therapy. In this work, chiral UCNPs/CuxOS@ZIF nanoprobes are prepared by encapsulating upconversion nanoparticles (UCNPs) and CuxOS nanoparticles (NPs) into zeolitic imidazolate framework-8 (ZIF-8). The novel excited-state energy distribution-modulated upconversion nanostructure (NaYbF4@NaYF4: Yb, Er) is selected as the fluorescence source and energy donor for highly efficient fluorescence resonance energy transfer (FRET). CuxOS NP is employed as chiral source and energy acceptor to quench upconversion luminescence (UCL) and provide circular dichroism (CD) signal. Utilizing the natural adsorption and sorting advantages of ZIF-8, the designed nanoprobe can isolate the influence of other common disruptors, thus achieve ultra-sensitive and highly selective UCL/CD dual-mode quantification of H2S in aqueous solution and in living cells. Notably, the nanoprobe is also capable of in vivo intra-tumoral H2S tracking. Our work highlights the multifunctional properties of chiral nanocomposites in sensing and opens a new vision and idea for the preparation and application of chiral nanomaterials in biomedical and biological analysis.

4.
Adv Sci (Weinh) ; : e2404178, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38946710

RESUMEN

2D transition metal borides (MBenes) with abundant surface terminals hold great promise in molecular sensing applications. However, MBenes from etching with fluorine-containing reagents present inert -fluorine groups on the surface, which hinders their sensing capability. Herein, the multilayer fluorine-free MoBTx MBene (where Tx represents O, OH, and Cl) with hydrophilic structure is prepared by a hydrothermal-assisted hydrochloric acid etching strategy based on guidance from the first-principle calculations. Significantly, the fluorine-free MoBTx-based humidity sensor is fabricated and demonstrates low resistance and excellent humidity performance, achieving a response of 90% to 98%RH and a high resolution of 1%RH at room temperature. By combining the experimental results with the first-principles calculations, the interactions between MoBTx and H2O, including the adsorption and intercalation of H2O, are understood first in depth. Finally, the portable humidity early warning system for real-time monitoring and early warning of infant enuresis and back sweating illustrates its potential for humidity sensing applications. This work not only provides guidance for preparation of fluorine-free MBenes, but also contributes to advancing their exploration in sensing applications.

5.
Adv Sci (Weinh) ; : e2405124, 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39041889

RESUMEN

Amid growing interest in the precise detection of volatile organic compounds (VOCs) in industrial field, the demand for highly effective gas sensors is at an all-time high. However, traditional sensors with their classic single-output signal, bulky and complex integrated structure when forming array often involve complicated technology and high cost, limiting their widespread adoption. Here, this study introduces a novel approach, employing an integrated YSZ-based (YSZ: yttria-stabilized zirconia) mixed potential sensor equipped with a triple-sensing electrode array, to efficiently detect and differentiate six types of VOCs gases. This innovative sensor integrates NiSb2O6, CuSb2O6, and MgSb2O6 sensing electrodes (SEs), which are sensitive to pentane, isoprene, n-propanol, acetone, acetic acid, and formaldehyde gases. Through feature engineering based on intuitive spike-based response values, it accentuates the distinct characteristics of every gas. Eventually, an average classification accuracy of 98.8% and an overall R-squared error (R2) of 99.3% for concentration regression toward six target gases can be achieved, showcasing the potential to quantitatively distinguish between industrial hazardous VOCs gases.

6.
Biosens Bioelectron ; 263: 116613, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-39084044

RESUMEN

The biomimetic enzyme cascade system plays a key role in biosensing as a sophisticated signal transduction and amplification strategy. However, constructing a regulated enzyme cascade sensing system remains challenging due to the mismatch of multiple enzyme activities and poor stability. Herein, we design an efficient dual-enhanced enzyme cascade hybrid system (UFD-DEC) containing DNA-controlled nanozymes (Fe-cdDNA) and enzyme (urease) via combining the electrostatic contact effect with the hydrogel-directed confinement effect. Precise modulation of Fe-cdDNA nanozyme by DNA offers a means to control its catalytic efficiency. This regulated UFD-DEC system accelerates the reaction rate and provides remarkable stability compared with the free enzyme system. Benefiting from the plasticity properties of hydrogels, a "lab-in-a-tube" platform was constructed by encapsulating UFD-DEC in a microcentrifuge tube. Such a UFD-DEC-based hydrogel tube exhibits sufficient adaptability to profile urea when used in conjunction with a smartphone-assisted image processing algorithm, which on-site delivers urea information with a detection limit of 0.12 mmol L-1. This customizable and inexpensive miniaturized biosensor platform for monitoring urea may facilitate point-of-care testing applications.


Asunto(s)
Técnicas Biosensibles , Hidrogeles , Límite de Detección , Ureasa , Técnicas Biosensibles/métodos , Hidrogeles/química , Ureasa/química , Urea/análisis , Urea/química , ADN Catalítico/química , ADN/química
7.
ACS Sens ; 9(7): 3763-3772, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-38984447

RESUMEN

A phosphorus-doped carbon nanotube (CNT) aerogel as the support material was loaded with Pt nanoparticles in fuel cell-type gas sensors for ultrasensitive H2 detection. The high surface area of the CNT scaffold is favorable to providing abundant active sites, and the high electrical conductivity facilitates the transport of carriers generated by electrochemical reactions. In addition, the CNT aerogel was doped with phosphorus (P) to further enhance the conductivity and electrochemical catalytic activity. As a result, the fuel cell-type gas sensor using the Pt/CNT aerogel doped with the optimal P content as the sensing material shows considerable performance for H2 detection at room temperature. The sensor exhibits an ultrahigh response of -921.9 µA to 15,000 ppm of H2. The sensitivity is -0.063 µA/ppm, which is 21 times higher than that of the conventional Pt/CF counterpart. The sensor also exhibits excellent repeatability and humidity resistance, as well as fast response/recovery; the response/recovery times are 31 and 4 s to 3000 ppm of H2, respectively. The modulation of the structure and catalytic properties of the support material is responsible for the improvement of the sensor performance, thus providing a feasible solution for optimizing the performance of fuel cell-type gas sensors.


Asunto(s)
Geles , Hidrógeno , Nanotubos de Carbono , Fósforo , Platino (Metal) , Nanotubos de Carbono/química , Platino (Metal)/química , Fósforo/química , Hidrógeno/química , Hidrógeno/análisis , Geles/química , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Catálisis
8.
ACS Nano ; 18(24): 15681-15694, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38848285

RESUMEN

The prolonged wound-healing process caused by pathogen infection remains a major public health challenge. The developed electrical antibiotic administration typically requires metal electrodes wired to a continuous power supply, restricting their use beyond clinical environments. To obviate the necessity for antibiotics and an external power source, we have developed a wearable synergistic electroceutical device composed of an air self-charging Zn battery. This battery integrates sustained tissue regeneration and antibacterial modalities while maintaining more than half of the initial capacity after ten cycles of chemical charging. In vitro bacterial/cell coculture with the self-charging battery demonstrates inhibited bacterial activity and enhanced cell function by simulating the endogenous electric field and dynamically engineering the microenvironment with released chemicals. This electroceutical device provides accelerated healing of a bacteria-infected wound by stimulating angiogenesis and modulating inflammation, while effectively inhibiting bacterial growth at the wound site. Considering the simple structure and easy operation for long-term treatment, this self-charging electroceutical device offers great potential for personalized wound care.


Asunto(s)
Antibacterianos , Dispositivos Electrónicos Vestibles , Cicatrización de Heridas , Animales , Antibacterianos/farmacología , Antibacterianos/química , Humanos , Ratones , Staphylococcus aureus/fisiología , Zinc/química , Escherichia coli , Pruebas de Sensibilidad Microbiana
9.
J Colloid Interface Sci ; 670: 626-634, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38781653

RESUMEN

On-site quantitative analysis of pesticide residues is crucial for monitoring environmental quality and ensuring food safety. Herein, we have developed a reliable hydrogel portable kit using NaYbF4@NaYF4: Yb, Tm upconversion nanoparticles (UCNPs) combined with MnO2 nanoflakes. This portable kit is integrated with a smartphone reader and Python-assisted analysis platform to enable sample-to-result analysis for chlorpyrifos. The novel UCNPs maximizes energy donation to MnO2 acceptor by employing 100 % of activator Yb3+ in the nucleus for NIR excitation energy collection and confining emitter Tm3+ to the surface layer to shorten energy transfer distance. Under NIR excitation, efficient quenching of upconversion blue-violet emission by MnO2 nanoflakes occurs, and the quenched emission is recovered with acetylcholinesterase-mediated reactions. This process allows for the determination of chlorpyrifos by inhibiting enzymatic activity. The UCNPs/MnO2 were embedded to fabricate a hydrogel portable kit, the blue-violet emission images captured by smartphone were converted into corresponding gray values by Python-assisted superiority chart algorithm which achieves a real-time rapid quantitative analysis of chlorpyrifos with a detection limit of 0.17 ng mL-1. At the same time, pseudo-color images were also added by Python in "one run" to distinguish images clearly. This sensor detection with Python-assisted analysis platform provides a new perspective on pesticide monitoring and broadens the application prospects in bioanalysis.

10.
Food Chem ; 452: 139569, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38744131

RESUMEN

Given the potential dangers of thiram to food safety, constructing a facile sensor is significantly critical. Herein, we presented a colorimetric sensor based on glutathione­iron hybrid (GSH-Fe) nanozyme for specific and stable detection of thiram. The GSH-Fe nanozyme exhibits good peroxidase-mimicking activity with comparable Michaelis constant (Km = 0.551 mM) to the natural enzyme. Thiram pesticides can specifically limit the catalytic activity of GSH-Fe nanozyme via surface passivation, causing the change of colorimetric signal. It is worth mentioning that the platform was used to prepare a portable hydrogel kit for rapid qualitative monitoring of thiram. Coupling with an image-processing algorithm, the colorimetric image of the hydrogel reactor is converted into the data information for accurate quantification of thiram with a detection limit of 0.3 µg mL-1. The sensing system has good selectivity and high stability, with recovery rates in fruit juice samples ranging from 92.4% to 106.9%.


Asunto(s)
Colorimetría , Jugos de Frutas y Vegetales , Glutatión , Hierro , Tiram , Colorimetría/instrumentación , Jugos de Frutas y Vegetales/análisis , Hierro/química , Hierro/análisis , Glutatión/química , Glutatión/análisis , Tiram/análisis , Tiram/química , Contaminación de Alimentos/análisis , Plaguicidas/análisis , Plaguicidas/química , Límite de Detección , Técnicas Biosensibles/instrumentación
11.
J Hazard Mater ; 472: 134508, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38754234

RESUMEN

As one of main high-energy fuels for rocket launching, unsymmetrical dimethylhydrazine (UDMH) and its decomposition products do harm to environment and human health. It is significant to develop a device to monitor its leakage. In this work, a UDMH gas sensor based on In2O3 hollow microspheres with Nd dopant was fabricated. The pure, 1.0 mol%, 3.0 mol% and 5.0 mol% Nd doped In2O3 were synthesized via one-step solvothermal method. Among them, 3.0% Nd-In2O3 based sensor exhibits the highest response toward UDMH vapor. Its response value to 100 ppm UDMH is 183.3 at optimal working temperature of 250 °C, 6.8 times higher than that of pure In2O3 (26.8). Besides high response to UDMH, the 3% Nd-In2O3 based sensor represents excellent selectivity, rapid response speed (2 s) and ultra-low theoretical LOD to UDMH (0.28 ppb). The improved gas sensing performance via Nd doping could be attributed to the enhanced specific surface area, increased concentration of adsorbed oxygen and improved adsorption capacity for UDMH molecular on the surface. The excellent sensing performance of Nd doped In2O3 hollow microspheres makes it a promising candidate for real-time UDMH detection.

12.
Nanomaterials (Basel) ; 14(5)2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38470725

RESUMEN

N-butanol (C4H9OH) is a volatile organic compound (VOC) that is susceptible to industrial explosions. It has become imperative to develop n-butanol sensors with high selectivity and fast response and recovery kinetics. CdS/Ag2S composite nanomaterials were designed and prepared by the solvothermal method. The incorporation of Ag2S engendered a notable augmentation in specific surface area and a consequential narrow band gap. The CdS/Ag2S-based sensor with 3% molar ratio of Ag2S, operating at 200 °C, demonstrated a remarkably elevated response (S = Ra/Rg = 24.5) when exposed to 100 ppm n-butanol, surpassing the pristine CdS by a factor of approximately four. Furthermore, this sensor exhibited notably shortened response and recovery times, at a mere 4 s and 1 s, respectively. These improvements were ascribed to the one-dimensional single-crystal nanorod structure of CdS, which provided an effective path for expedited electron transport along its axial dimension. Additionally, the electron and chemical sensitization effects resulting from the modification with precious metal sulfides Ag2S were the primary reasons for enhancing the sensor response. This work can contribute to mitigating the safety risks associated with the use of n-butanol in industrial processes.

13.
ACS Sens ; 9(3): 1575-1583, 2024 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-38483350

RESUMEN

Monitoring of isoprene in exhaled breath is expected to provide a noninvasive and painless method for dynamic monitoring of physiological and metabolic states during exercise. However, for real-time and portable detection of isoprene, gas sensors have become the best choice for gas detection technology, which are crucial to achieving the goal of anytime, anywhere, human-centered healthcare in the future. Here, we first report a mixed potential type isoprene sensor based on a Gd2Zr2O7 solid electrolyte and a CdSb2O6 sensing electrode, which enables sensitive detection for isoprene with sensitivities of -21.2 mV/ppm and -65.8 mV/decade in the range of 0.05-1 and 1-100 ppm. The sensing behavior of the sensor follows the mixed potential sensing mechanism and was further verified by the electrochemical polarization curves. The significant differentiation between the sensor response to exhaled breath of healthy individuals and simulated breath containing different concentrations of isoprene demonstrates the potential of the sensor for the detection of isoprene in exhaled breath. Simultaneously, monitoring of isoprene during exercise signifies the feasibility of the sensor in dynamic monitoring of physiological indicators, which is not only of great significance for optimizing training and guiding therapeutic exercise intervention in sporting scenarios but also expected to help further reveal the interaction between exercise, muscle, and organ metabolism in medicine.


Asunto(s)
Pruebas Respiratorias , Gases , Hemiterpenos , Humanos , Pruebas Respiratorias/métodos , Butadienos , Biomarcadores
14.
ACS Sens ; 9(4): 1967-1977, 2024 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-38494643

RESUMEN

Bimetallic nanocrystals (NCs) have obtained significant attention due to their unique advantages of the intrinsic properties of individual metals and synergistic enhancements resulting from the electronic coupling between two constituent metals. In this work, Pd@Pt core-shell NCs were prepared through a facile one-pot solution-phase method, which had excellent dispersion and uniform size. Concurrently, ZnO nanosheets were prepared via a hydrothermal method. To explore their potential in nitrogen dioxide (NO2) gas sensing applications, sensitive materials based on ZnO nanosheets with varying mass percentages of Pd@Pt NCs were generated through an impregnation process. The sensor based on 0.3 wt % Pd@Pt-ZnO exhibited remarkable performance, demonstrating a substantial response (Rg/Ra = 60.3) to 50 ppb of NO2 at a low operating temperature of 80 °C. Notably, this sensor reached an outstanding low detection limit of 300 ppt. The enhancement in gas sensing capabilities can be attributed to the sensitization and synergistic effects imparted by the exceptional catalytic activity of Pd@Pt NCs, which significantly promoted the reaction. This research introduces a novel approach for the utilization of core-shell structured bimetallic nanocrystals as modifiers in metal-oxide-semiconductor (MOS) materials for NO2 detection.


Asunto(s)
Dióxido de Nitrógeno , Paladio , Platino (Metal) , Óxido de Zinc , Óxido de Zinc/química , Dióxido de Nitrógeno/análisis , Dióxido de Nitrógeno/química , Paladio/química , Platino (Metal)/química , Nanopartículas del Metal/química , Límite de Detección
15.
ACS Sens ; 9(4): 2057-2065, 2024 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-38552136

RESUMEN

The construction of ammonia gas sensors with wide detection ranges is important for exhalation diagnosis and environmental pollution monitoring. To achieve a wide detection range, sensitive materials must possess excellent spatial confinement and large active surfaces to enhance gas adsorption. In this study, an ammonia microwave gas sensor with a wide detection range of 10 ppb-0.55 v/v% at room temperature was fabricated by incorporating hollow multishelled-structured BaTiO3 (HoMS-BaTiO3). The effect of the number of shells and the quantity of the sensitive material on the gas-sensing performance was investigated, and two-layered HoMS-BaTiO3 demonstrated the best response at high concentrations (0.15-0.55 v/v%). Conversely, single-layered HoMS-BaTiO3 displayed outstanding performance at low concentrations (10 ppb-0.15 v/v%). The lower the quantity of the sensitive material, the higher the response. This study offers a method for preparing room-temperature ammonia sensors with a wide detection range and reveals the link between the structure and quantity of sensitive materials and gas-sensing performance.


Asunto(s)
Amoníaco , Compuestos de Bario , Microondas , Temperatura , Titanio , Amoníaco/análisis , Compuestos de Bario/química , Titanio/química , Límite de Detección , Gases/análisis , Gases/química
16.
Small ; 20(29): e2310465, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38366001

RESUMEN

The modification of metal oxides with noble metals is one of the most effective means of improving gas-sensing performance of chemiresistors, but it is often accompanied by unintended side effects such as sensor resistance increases up to unmeasurable levels. Herein, a carbonization-oxidation method is demonstrated using ultrasonic spray pyrolysis technique to realize platinum (Pt) single atom (SA) substitutional doping into SnO2 (named PtSA-SnO2). The substitutional doping strategy can obviously enhance gas-sensing properties, and meanwhile decrease sensor resistance by two orders of magnitude (decreased from ≈850 to ≈2 MΩ), which are attributed to the tuning of band gap and fermi-level position, efficient single atom catalysis, and the raising of adsorption capability of formaldehyde, as validated by the state-of-the-art characterizations, such as spherical aberration-corrected scanning transmission electron microscopy (Cs-corrected STEM), in situ diffuse reflectance infrared Fourier transformed spectra (in situ DRIFT), CO temperature-programmed reduction (CO-TPR), and theoretical calculations. As a proof of concept, the developed PtSA-SnO2 sensor shows humidity-independent (30-70% relative humidity) gas-sensing performance in the selective detection of formaldehyde with high response, distinguishable selectivity (8< Sformaldehyde/Sinterferant <14), and ultra-low detection limit (10 ppb). This work presents a generalized and facile method to design high-performance metal oxides for chemical sensing of volatile organic compounds (VOCs).

17.
Adv Mater ; 36(16): e2311144, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38190757

RESUMEN

Plant-wearable sensors provide real-time information that enables pesticide inputs to be finely tuned and play critical roles in precision agriculture. However, tracking pesticide information in living plants remains a formidable challenge owing to inadequate shape adaptabilities and low in-field sensor sensitivities. In this study, plant-wearable hydrogel discs are designed by embedding a dual-shelled upconversion-nanoparticles@zeolitic-imidazolate-framework@polydopamine (UCNPs@ZIF@PDA) composite in double-network hydrogels to deliver on-site pesticide-residue information. Benefiting from the enzyme-mimetic catalytic activity of ZIFs and enzyme triggered-responsive property of PDA shell, the hydrogel discs are endowed with high sensing sensitivity toward 2,4-dichlorophenoxyacetic acid pesticide at the nanogram per milliliter level via boosting fluorescence quenching efficiency. Notably, hydrogel discs mounted on tomato plants exhibit sufficient adaptability to profile dynamic pesticide degradation when used in conjunction with an ImageJ processing algorithm, which is practically applicable. Such hydrogel discs form a noninvasive and low-cost toolkit for the on-site acquisition of pesticide information, thereby contributing to the precise management of the health status of a plant and the judicious development of precision agriculture.


Asunto(s)
Plaguicidas , Dispositivos Electrónicos Vestibles , Zeolitas , Zeolitas/química , Catálisis , Hidrogeles
18.
ACS Sens ; 9(1): 464-473, 2024 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-38153408

RESUMEN

Breath analysis using gas sensors is an emerging method for disease screening and diagnosis. Since it is closely related to the lipid metabolism and blood ketone concentration of the body, the detection of acetone content in exhaled breath is helpful for the screening and monitoring of diabetes and ketosis. The development of an acetone sensor with high selectivity, stability, and low detection limit has been the research focus for this purpose. Here, we developed a mixed potential type acetone sensor based on Gd2Zr2O7 solid electrolyte and CoSb2O6 sensing electrode. The developed sensor exhibits an extremely low detection limit of 10 ppb, enabling linear detection for acetone in an extremely wide range of 10 ppb-100 ppm. The good results of systematic evaluation on selectivity, repeatability, and stability prove the superior reliability of the sensor, which is a prerequisite for the application in actual breath detection. The ability of the sensor to distinguish healthy people from diabetic ketosis patients was confirmed by using the sensor to detect the breath of healthy people and diabetic patients, proving the feasibility of the sensor in the diagnosis and monitoring of diabetic ketosis.


Asunto(s)
Diabetes Mellitus , Cetoacidosis Diabética , Humanos , Cetoacidosis Diabética/diagnóstico , Acetona/análisis , Límite de Detección , Reproducibilidad de los Resultados , Cetonas , Diabetes Mellitus/diagnóstico
19.
ACS Sens ; 9(1): 171-181, 2024 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-38159288

RESUMEN

With the rapid development of the concept of the Internet of Things (IoT), gas sensors with the function of simulating the human sense of smell became irreplaceable as a key element. Among them, ammonia (NH3) sensors played an important role in respiration tests, environmental monitoring, safety, and other fields. However, the fabrication of the high-performance device with high stability and resistance to mechanical damages was still a challenge. In this work, polyurethane (PU) with excellent self-healing ability was applied as the substrate, and the sensor was designed from new sensitive material design and device structure optimization, through applying the organic molecule with groups which could absorb NH3 and the laminated structure to shorten the electronic transmission path to achieve a low resistance state and favorable sensing properties. Accordingly, a room temperature flexible NH3 sensor based on 6,6',6″-(nitrilotris(benzene-4,1-diyl))tris(5-phenylpyrazine-2,3-dicarbonitrile) (TPA-3DCNPZ) was successfully developed. The device could self-heal by means of a thermal evaporation assisted method. It exhibited a detection limit of 1 ppm at 98% relative humidity (RH), as well as great stability, selectivity, bending flexibility, and self-healing properties. The improved NH3 sensing performance under high RH was further investigated by complex impedance plots (CIPs) and density functional theory (DFT), attributing to the enhanced adsorption of NH3. The TPA-3DCNPZ based NH3 sensors proved to have great potential for application on simulated exhaled breath to determine the severity of kidney diseases and the progress of treatment. This work also provided new ideas for the construction of high-performance room temperature NH3 sensors.


Asunto(s)
Materiales Inteligentes , Humanos , Benceno , Temperatura , Adsorción , Amoníaco
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA