Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
World J Gastroenterol ; 23(20): 3684-3689, 2017 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-28611521

RESUMEN

AIM: To assess the feasibility and safety of a novel enteroscope, negative-pressure suction endoscope in examining the small intestine of a porcine model. METHODS: In vitro experiments in small intestinal loops from 20 pigs and in vivo experiments in 20 living pigs were conducted. RESULTS: In in vitro experiments, a negative pressure of > 0.06 MPa was necessary for optimal visualization of the intestine, and this pressure did not cause gross or histological damage to the mucosa. For satisfactory examination of the small intestine in vivo, higher negative pressure (> 1.00 MPa) was required. Despite this higher pressure, the small intestine did not show any gross or microscopic damage in the suctioned areas. The average time of examination in the living animals was 60 ± 7.67 min. The animals did not experience any apparent ill effects from the procedure. CONCLUSION: Small intestine endoscope was safely performed within a reasonable time period and enabled complete visualization of the intestine in most cases.


Asunto(s)
Endoscopía Gastrointestinal/instrumentación , Endoscopía Gastrointestinal/métodos , Intestino Delgado/diagnóstico por imagen , Animales , Modelos Animales de Enfermedad , Estudios de Factibilidad , Técnicas In Vitro , Seguridad del Paciente , Presión , Porcinos
2.
Zhonghua Wai Ke Za Zhi ; 46(12): 932-5, 2008 Jun 15.
Artículo en Chino | MEDLINE | ID: mdl-19035154

RESUMEN

OBJECTIVE: To detect the serum specific proteins in pancreatic cancer patients and establish diagnostic model by surface enhanced laser desorption/ionization time of flight mass spectrometry (SELDI-TOF-MS) technique. METHODS: Twenty-nine serum samples from patients of pancreatic cancer were collected before surgery and an additional 57 serum samples from age and sex matched individuals without cancer were used as controls, SELDI-TOF-MS technique and WCX magnetic beads were used to detect the protein fingerprint expression of all the serum samples and the resulting profiles between pancreatic cancer patients and controls were analyzed with biomarker wizard system, established the model using biomarker patterns system software. A double-blind test was used to determine the sensitivity and specificity of the classification model. RESULTS: A panel of four biomarkers (relative molecular weight are 5705, 4935, 5318 and 3243 Da) were selected to set up a decision trees as the classification model for screening pancreatic cancer effectively. The result yielded a sensitivity of 100%, specificity of 97.4%. The double-blind test challenged the model with a sensitivity of 88.9% and a specificity of 89.5%. CONCLUSIONS: SELDI-TOF-MS offers a unique platform for the proteomic detection of serum in pancreatic cancer patients. It also offers a noninvasive method to further study the proteomic changes in the development and progression of pancreatic cancer.


Asunto(s)
Neoplasias Pancreáticas/diagnóstico , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Biomarcadores de Tumor/sangre , Proteínas Sanguíneas/análisis , Detección Precoz del Cáncer , Humanos , Tamizaje Masivo , Neoplasias Pancreáticas/sangre , Proteómica , Sensibilidad y Especificidad
3.
Zhonghua Wai Ke Za Zhi ; 46(7): 525-7, 2008 Apr 01.
Artículo en Chino | MEDLINE | ID: mdl-18785564

RESUMEN

OBJECTIVE: To detect the serum specific proteins in tumor-like polypoid lesions of the gallbladder patients and establish diagnostic model. METHODS: Surface enhanced laser desorption/ionization time of flight mass spectrometry (SELDI-TOF-MS) technique and WCX Magnetic Beads were used to detect the serum proteomic patterns of 23 patients with tumor-like PLG, 21 patients with non tumor-like PLG and 26 normal persons. Biomarker Wizard and Biomarker Patterns Software were used in combination to analyze the data. RESULTS: Preliminary screening out 22 representative specific proteins for the diagnosis of the tumor-like PLG. Analysis system under the conditions set selected 3 specific proteins to establish diagnostic model for the tumor-like PLG. The sensitivity and specificity of the model for the diagnosis of the tumor-like PLG were 100% and 89.4%, respectively. CONCLUSION: SELDI-TOF-MS technique can select specific protein of the tumor-like PLG, and establish diagnostic model of the tumor-like PLG.


Asunto(s)
Proteínas Sanguíneas/análisis , Neoplasias de la Vesícula Biliar/diagnóstico , Pólipos/diagnóstico , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Adulto , Anciano , Biomarcadores de Tumor/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...