Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Nat Biotechnol ; 40(7): 1082-1092, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35256815

RESUMEN

Single-nuclei RNA sequencing characterizes cell types at the gene level. However, compared to single-cell approaches, many single-nuclei cDNAs are purely intronic, lack barcodes and hinder the study of isoforms. Here we present single-nuclei isoform RNA sequencing (SnISOr-Seq). Using microfluidics, PCR-based artifact removal, target enrichment and long-read sequencing, SnISOr-Seq increased barcoded, exon-spanning long reads 7.5-fold compared to naive long-read single-nuclei sequencing. We applied SnISOr-Seq to adult human frontal cortex and found that exons associated with autism exhibit coordinated and highly cell-type-specific inclusion. We found two distinct combination patterns: those distinguishing neural cell types, enriched in TSS-exon, exon-polyadenylation-site and non-adjacent exon pairs, and those with multiple configurations within one cell type, enriched in adjacent exon pairs. Finally, we observed that human-specific exons are almost as tightly coordinated as conserved exons, implying that coordination can be rapidly established during evolution. SnISOr-Seq enables cell-type-specific long-read isoform analysis in human brain and in any frozen or hard-to-dissociate sample.


Asunto(s)
Encéfalo , ARN , Empalme Alternativo/genética , Encéfalo/metabolismo , Exones/genética , Humanos , Isoformas de Proteínas/genética , ARN/genética , Análisis de Secuencia de ARN
2.
Genome Biol ; 22(1): 109, 2021 04 16.
Artículo en Inglés | MEDLINE | ID: mdl-33863344

RESUMEN

BACKGROUND: Targeted sequencing using oncopanels requires comprehensive assessments of accuracy and detection sensitivity to ensure analytical validity. By employing reference materials characterized by the U.S. Food and Drug Administration-led SEquence Quality Control project phase2 (SEQC2) effort, we perform a cross-platform multi-lab evaluation of eight Pan-Cancer panels to assess best practices for oncopanel sequencing. RESULTS: All panels demonstrate high sensitivity across targeted high-confidence coding regions and variant types for the variants previously verified to have variant allele frequency (VAF) in the 5-20% range. Sensitivity is reduced by utilizing VAF thresholds due to inherent variability in VAF measurements. Enforcing a VAF threshold for reporting has a positive impact on reducing false positive calls. Importantly, the false positive rate is found to be significantly higher outside the high-confidence coding regions, resulting in lower reproducibility. Thus, region restriction and VAF thresholds lead to low relative technical variability in estimating promising biomarkers and tumor mutational burden. CONCLUSION: This comprehensive study provides actionable guidelines for oncopanel sequencing and clear evidence that supports a simplified approach to assess the analytical performance of oncopanels. It will facilitate the rapid implementation, validation, and quality control of oncopanels in clinical use.


Asunto(s)
Biomarcadores de Tumor , Pruebas Genéticas/métodos , Genómica/métodos , Neoplasias/genética , Oncogenes , Variaciones en el Número de Copia de ADN , Pruebas Genéticas/normas , Genómica/normas , Humanos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Mutación , Neoplasias/diagnóstico , Polimorfismo de Nucleótido Simple , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Genome Biol ; 22(1): 111, 2021 04 16.
Artículo en Inglés | MEDLINE | ID: mdl-33863366

RESUMEN

BACKGROUND: Oncopanel genomic testing, which identifies important somatic variants, is increasingly common in medical practice and especially in clinical trials. Currently, there is a paucity of reliable genomic reference samples having a suitably large number of pre-identified variants for properly assessing oncopanel assay analytical quality and performance. The FDA-led Sequencing and Quality Control Phase 2 (SEQC2) consortium analyze ten diverse cancer cell lines individually and their pool, termed Sample A, to develop a reference sample with suitably large numbers of coding positions with known (variant) positives and negatives for properly evaluating oncopanel analytical performance. RESULTS: In reference Sample A, we identify more than 40,000 variants down to 1% allele frequency with more than 25,000 variants having less than 20% allele frequency with 1653 variants in COSMIC-related genes. This is 5-100× more than existing commercially available samples. We also identify an unprecedented number of negative positions in coding regions, allowing statistical rigor in assessing limit-of-detection, sensitivity, and precision. Over 300 loci are randomly selected and independently verified via droplet digital PCR with 100% concordance. Agilent normal reference Sample B can be admixed with Sample A to create new samples with a similar number of known variants at much lower allele frequency than what exists in Sample A natively, including known variants having allele frequency of 0.02%, a range suitable for assessing liquid biopsy panels. CONCLUSION: These new reference samples and their admixtures provide superior capability for performing oncopanel quality control, analytical accuracy, and validation for small to large oncopanels and liquid biopsy assays.


Asunto(s)
Alelos , Biomarcadores de Tumor , Frecuencia de los Genes , Pruebas Genéticas/métodos , Variación Genética , Genómica/métodos , Neoplasias/genética , Línea Celular Tumoral , Variaciones en el Número de Copia de ADN , Heterogeneidad Genética , Pruebas Genéticas/normas , Genómica/normas , Humanos , Neoplasias/diagnóstico , Flujo de Trabajo
4.
Mol Ther ; 26(10): 2431-2442, 2018 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-30005866

RESUMEN

Genome-editing technologies are currently being translated to the clinic. However, cellular effects of the editing machinery have yet to be fully elucidated. Here, we performed global microarray-based gene expression measurements on human CD34+ hematopoietic stem and progenitor cells that underwent editing. We probed effects of the entire editing process as well as each component individually, including electroporation, Cas9 (mRNA or protein) with chemically modified sgRNA, and AAV6 transduction. We identified differentially expressed genes relative to control treatments, which displayed enrichment for particular biological processes. All editing machinery components elicited immune, stress, and apoptotic responses. Cas9 mRNA invoked the greatest amount of transcriptional change, eliciting a distinct viral response and global transcriptional downregulation, particularly of metabolic and cell cycle processes. Electroporation also induced significant transcriptional change, with notable downregulation of metabolic processes. Surprisingly, AAV6 evoked no detectable viral response. We also found Cas9/sgRNA ribonucleoprotein treatment to be well tolerated, in spite of eliciting a DNA damage signature. Overall, this data establishes a benchmark for cellular tolerance of CRISPR/Cas9-AAV6-based genome editing, ensuring that the clinical protocol is as safe and efficient as possible.


Asunto(s)
Terapia Genética , Vectores Genéticos/genética , Análisis por Micromatrices/métodos , Parvovirinae/genética , Antígenos CD34/genética , Proteína 9 Asociada a CRISPR/genética , Sistemas CRISPR-Cas/genética , Dependovirus , Electroporación , Edición Génica/métodos , Regulación de la Expresión Génica/genética , Vectores Genéticos/uso terapéutico , Trasplante de Células Madre Hematopoyéticas , Células Madre Hematopoyéticas/efectos de los fármacos , Humanos , Células Madre/efectos de los fármacos
5.
Methods Mol Biol ; 1783: 81-104, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29767358

RESUMEN

Gene expression profiling of samples from biobanks requires a method that can be used with intact as well as partially degraded RNA. High throughput applications can benefit from reducing the number of processing steps including eliminating the poly(A) selection and ribosomal depletion steps. When performing targeted capture, we have found that we can eliminate the upfront poly(A) selection/ribosomal depletion steps that cause bias in standard mRNA-Seq workflows. This target enrichment solution allows for whole transcriptome or customized content to characterize differential gene expression patterns (especially for mid/low level transcripts). Protocol modifications to the Agilent Strand-Specific RNA Library Prep kit resulted in a new workflow called "RNA Direct" that generates RNA-Seq data with minimal ribosomal contamination and good sequencing coverage. Using RNA isolated from a set of matched samples including fresh frozen (FF) or formalin-fixed, paraffin-embedded (FFPE) from tumor/normal tissues we generated high-quality data using a protocol that does not require upfront ribosomal depletion or poly(A) selection. Using SureSelectXT RNA Direct protocol (RNA Direct) workflow, we found transcripts to be upregulated or downregulated to similar degrees with similar confidence levels in both the FF and FFPE samples, demonstrating the utility for meaningful gene expression studies with biobank samples of variable quality.


Asunto(s)
Biomarcadores/análisis , Perfilación de la Expresión Génica/métodos , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Neoplasias/genética , ARN/genética , Análisis de Secuencia de ARN/métodos , Transcriptoma , Biblioteca de Genes , Humanos , Adhesión en Parafina , ARN/aislamiento & purificación , Fijación del Tejido , Flujo de Trabajo
6.
BMC Biotechnol ; 16(1): 54, 2016 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-27342544

RESUMEN

BACKGROUND: Highly multiplexed assays for quantitation of RNA transcripts are being used in many areas of biology and medicine. Using data generated by these transcriptomic assays requires measurement assurance with appropriate controls. Methods to prototype and evaluate multiple RNA controls were developed as part of the External RNA Controls Consortium (ERCC) assessment process. These approaches included a modified Latin square design to provide a broad dynamic range of relative abundance with known differences between four complex pools of ERCC RNA transcripts spiked into a human liver total RNA background. RESULTS: ERCC pools were analyzed on four different microarray platforms: Agilent 1- and 2-color, Illumina bead, and NIAID lab-made spotted microarrays; and two different second-generation sequencing platforms: the Life Technologies 5500xl and the Illumina HiSeq 2500. Individual ERCC controls were assessed for reproducible performance in signal response to concentration among the platforms. Most demonstrated linear behavior if they were not located near one of the extremes of the dynamic range. Performance issues with any individual ERCC transcript could be attributed to detection limitations, platform-specific target probe issues, or potential mixing errors. Collectively, these pools of spike-in RNA controls were evaluated for suitability as surrogates for endogenous transcripts to interrogate the performance of the RNA measurement process of each platform. The controls were useful for establishing the dynamic range of the assay, as well as delineating the useable region of that range where differential expression measurements, expressed as ratios, would be expected to be accurate. CONCLUSIONS: The modified Latin square design presented here uses a composite testing scheme for the evaluation of multiple performance characteristics: linear performance of individual controls, signal response within dynamic range pools of controls, and ratio detection between pairs of dynamic range pools. This compact design provides an economical sample format for the evaluation of multiple external RNA controls within a single experiment per platform. These results indicate that well-designed pools of RNA controls, spiked into samples, provide measurement assurance for endogenous gene expression studies.


Asunto(s)
Perfilación de la Expresión Génica/normas , Secuenciación de Nucleótidos de Alto Rendimiento/normas , ARN/genética , ARN/normas , Análisis de Secuencia de ARN/normas , Algoritmos , Perfilación de la Expresión Génica/métodos , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
Nature ; 477(7364): 295-300, 2011 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-21874018

RESUMEN

Although thousands of large intergenic non-coding RNAs (lincRNAs) have been identified in mammals, few have been functionally characterized, leading to debate about their biological role. To address this, we performed loss-of-function studies on most lincRNAs expressed in mouse embryonic stem (ES) cells and characterized the effects on gene expression. Here we show that knockdown of lincRNAs has major consequences on gene expression patterns, comparable to knockdown of well-known ES cell regulators. Notably, lincRNAs primarily affect gene expression in trans. Knockdown of dozens of lincRNAs causes either exit from the pluripotent state or upregulation of lineage commitment programs. We integrate lincRNAs into the molecular circuitry of ES cells and show that lincRNA genes are regulated by key transcription factors and that lincRNA transcripts bind to multiple chromatin regulatory proteins to affect shared gene expression programs. Together, the results demonstrate that lincRNAs have key roles in the circuitry controlling ES cell state.


Asunto(s)
Diferenciación Celular/genética , Células Madre Pluripotentes/citología , Células Madre Pluripotentes/metabolismo , ARN no Traducido/genética , ARN no Traducido/metabolismo , Animales , Linaje de la Célula/genética , Cromatina/genética , Cromatina/metabolismo , Regulación de la Expresión Génica/genética , Técnicas de Silenciamiento del Gen , Ratones , Unión Proteica , Factores de Transcripción/metabolismo
8.
Nat Biotechnol ; 24(9): 1132-9, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16964227

RESUMEN

External RNA controls (ERCs), although important for microarray assay performance assessment, have yet to be fully implemented in the research community. As part of the MicroArray Quality Control (MAQC) study, two types of ERCs were implemented and evaluated; one was added to the total RNA in the samples before amplification and labeling; the other was added to the copyRNAs (cRNAs) before hybridization. ERC concentration-response curves were used across multiple commercial microarray platforms to identify problematic assays and potential sources of variation in the analytical process. In addition, the behavior of different ERC types was investigated, resulting in several important observations, such as the sample-dependent attributes of performance and the potential of using these control RNAs in a combinatorial fashion. This multiplatform investigation of the behavior and utility of ERCs provides a basis for articulating specific recommendations for their future use in evaluating assay performance across multiple platforms.


Asunto(s)
Análisis de Falla de Equipo/métodos , Perfilación de la Expresión Génica/instrumentación , Perfilación de la Expresión Génica/normas , Análisis de Secuencia por Matrices de Oligonucleótidos/instrumentación , Análisis de Secuencia por Matrices de Oligonucleótidos/normas , ARN/análisis , ARN/genética , Algoritmos , ARN/normas , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estados Unidos
9.
Nat Biotechnol ; 24(9): 1123-31, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16964226

RESUMEN

We have assessed the utility of RNA titration samples for evaluating microarray platform performance and the impact of different normalization methods on the results obtained. As part of the MicroArray Quality Control project, we investigated the performance of five commercial microarray platforms using two independent RNA samples and two titration mixtures of these samples. Focusing on 12,091 genes common across all platforms, we determined the ability of each platform to detect the correct titration response across the samples. Global deviations from the response predicted by the titration ratios were observed. These differences could be explained by variations in relative amounts of messenger RNA as a fraction of total RNA between the two independent samples. Overall, both the qualitative and quantitative correspondence across platforms was high. In summary, titration samples may be regarded as a valuable tool, not only for assessing microarray platform performance and different analysis methods, but also for determining some underlying biological features of the samples.


Asunto(s)
Análisis de Falla de Equipo/métodos , Perfilación de la Expresión Génica/instrumentación , Perfilación de la Expresión Génica/normas , Análisis de Secuencia por Matrices de Oligonucleótidos/instrumentación , Análisis de Secuencia por Matrices de Oligonucleótidos/normas , ARN/análisis , ARN/genética , Algoritmos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estados Unidos
10.
Nat Biotechnol ; 24(9): 1151-61, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16964229

RESUMEN

Over the last decade, the introduction of microarray technology has had a profound impact on gene expression research. The publication of studies with dissimilar or altogether contradictory results, obtained using different microarray platforms to analyze identical RNA samples, has raised concerns about the reliability of this technology. The MicroArray Quality Control (MAQC) project was initiated to address these concerns, as well as other performance and data analysis issues. Expression data on four titration pools from two distinct reference RNA samples were generated at multiple test sites using a variety of microarray-based and alternative technology platforms. Here we describe the experimental design and probe mapping efforts behind the MAQC project. We show intraplatform consistency across test sites as well as a high level of interplatform concordance in terms of genes identified as differentially expressed. This study provides a resource that represents an important first step toward establishing a framework for the use of microarrays in clinical and regulatory settings.


Asunto(s)
Perfilación de la Expresión Génica/instrumentación , Análisis de Secuencia por Matrices de Oligonucleótidos/instrumentación , Garantía de la Calidad de Atención de Salud/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Perfilación de la Expresión Génica/métodos , Control de Calidad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...