Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Acta Biomater ; 171: 155-165, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37797706

RESUMEN

Pulmonary hypertension (PHT) is a devastating disease with low survival rates. In PHT, chronic pressure overload leads to right ventricle (RV) stiffening; thus, impeding diastolic filling. Multiple mechanisms may contribute to RV stiffening, including wall thickening, microstructural disorganization, and myocardial stiffening. The relative importance of each mechanism is unclear. Our objective is to use a large animal model to untangle these mechanisms. Thus, we induced pulmonary arterial hypertension (PAH) in sheep via pulmonary artery banding. After eight weeks, the hearts underwent anatomic and diffusion tensor MRI to characterize wall thickening and microstructural disorganization. Additionally, myocardial samples underwent histological and gene expression analyses to quantify compositional changes and mechanical testing to quantify myocardial stiffening. Finally, we used finite element modeling to disentangle the relative importance of each stiffening mechanism. We found that the RVs of PAH animals thickened most at the base and the free wall and that PAH induced excessive collagen synthesis, increased cardiomyocyte cross-sectional area, and led to microstructural disorganization, consistent with increased expression of fibrotic genes. We also found that the myocardium itself stiffened significantly. Importantly, myocardial stiffening correlated significantly with collagen synthesis. Finally, our computational models predicted that myocardial stiffness contributes to RV stiffening significantly more than other mechanisms. Thus, myocardial stiffening may be the most important predictor for PAH progression. Given the correlation between myocardial stiffness and collagen synthesis, collagen-sensitive imaging modalities may be useful for estimating myocardial stiffness and predicting PAH outcomes. STATEMENT OF SIGNIFICANCE: Ventricular stiffening is a significant contributor to pulmonary hypertension-induced right heart failure. However, the mechanisms that lead to ventricular stiffening are not fully understood. The novelty of our work lies in answering this question through the use of a large animal model in combination with spatially- and directionally sensitive experimental techniques. We find that myocardial stiffness is the primary mechanism that leads to ventricular stiffening. Clinically, this knowledge may be used to improve diagnostic, prognostic, and therapeutic strategies for patients with pulmonary hypertension.


Asunto(s)
Hipertensión Pulmonar , Hipertensión Arterial Pulmonar , Humanos , Animales , Ovinos , Hipertensión Arterial Pulmonar/metabolismo , Hipertensión Arterial Pulmonar/patología , Hipertensión Pulmonar/diagnóstico por imagen , Hipertensión Pulmonar/metabolismo , Hipertensión Pulmonar/patología , Ventrículos Cardíacos/patología , Arteria Pulmonar/metabolismo , Arteria Pulmonar/patología , Colágeno/metabolismo , Modelos Animales de Enfermedad
2.
Magn Reson Med ; 86(6): 3304-3320, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34270123

RESUMEN

PURPOSE: Diffusion-weighted imaging allows investigators to identify structural, microstructural, and connectivity-based differences between subjects, but variability due to session and scanner biases is a challenge. METHODS: To investigate DWI variability, we present MASiVar, a multisite data set consisting of 319 diffusion scans acquired at 3 T from b = 1000 to 3000 s/mm2 across 14 healthy adults, 83 healthy children (5 to 8 years), three sites, and four scanners as a publicly available, preprocessed, and de-identified data set. With the adult data, we demonstrate the capacity of MASiVar to simultaneously quantify the intrasession, intersession, interscanner, and intersubject variability of four common DWI processing approaches: (1) a tensor signal representation, (2) a multi-compartment neurite orientation dispersion and density model, (3) white-matter bundle segmentation, and (4) structural connectomics. Respectively, we evaluate region-wise fractional anisotropy, mean diffusivity, and principal eigenvector; region-wise CSF volume fraction, intracellular volume fraction, and orientation dispersion index; bundle-wise shape, volume, fractional anisotropy, and length; and whole connectome correlation and maximized modularity, global efficiency, and characteristic path length. RESULTS: We plot the variability in these measures at each level and find that it consistently increases with intrasession to intersession to interscanner to intersubject effects across all processing approaches and that sometimes interscanner variability can approach intersubject variability. CONCLUSIONS: This study demonstrates the potential of MASiVar to more globally investigate DWI variability across multiple levels and processing approaches simultaneously and suggests harmonization between scanners for multisite analyses should be considered before inference of group differences on subjects.


Asunto(s)
Imagen de Difusión Tensora , Sustancia Blanca , Adulto , Anisotropía , Encéfalo/diagnóstico por imagen , Niño , Imagen de Difusión por Resonancia Magnética , Humanos , Neuritas
3.
Med Sci Sports Exerc ; 53(6): 1188-1193, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33433149

RESUMEN

PURPOSE: Reductions in skeletal muscle mass, beginning after the third decade of life, reduce maximal neuromuscular power (Pmax). Maximal aerobic power generation is also reduced. The primary purpose of this study was to investigate the effectiveness of maximal power cycling (PC) training using an inertial load ergometer on skeletal muscle mass and cardiovascular function in untrained 50- to 68-yr-old participants. METHODS: The study used a pre- or postoutcome exercise intervention testing untrained 50- to 68-yr-old adults (n = 39, M = 15, mean ± SE = 58.5 ± 0.8, range = 50-68 yr). Over the course of 8 wk, participants performed 15 min of training 3 times per week. Each session involved repeated (15-30 times) 4-s sprints of PC. Measurements were thigh muscle volume, total body lean mass, Pmax, peak oxygen consumption, cardio-ankle vascular index, performance on functional tests of living (FTLChair and FTLRamp), and intermuscular fat volume. RESULTS: Training for 8 wk increased thigh muscle volume (3.7% ± 0.9%, P < 0.001) and total body lean mass (1.5% ± 0.4%, P < 0.01) while increasing total body mass (TBM) (1.4% ± 0.3%, P < 0.01). Physical performance measures increased significantly (all P < 0.05) with improvements in Pmax (12.0% ± 1.5%); peak oxygen consumption (9.8% ± 1.8%), and FTL (8.5% ± 1.3% to 17.2% ± 2%). Cardio-ankle vascular index was significantly decreased -2.3% ± 1.1% (P < 0.05), indicating reduced arterial stiffness. CONCLUSIONS: These results demonstrate that 8 wk of PC training at true maximal power was effective at increasing muscle mass and maximal power, as well as maximal cardiovascular capacity and functional tasks in untrained 50- to 68-yr-olds.


Asunto(s)
Ciclismo/fisiología , Capacidad Cardiovascular , Entrenamiento de Intervalos de Alta Intensidad/métodos , Fuerza Muscular , Músculo Esquelético/anatomía & histología , Músculo Esquelético/fisiología , Factores de Edad , Anciano , Índice de Masa Corporal , Endotelio Vascular/fisiología , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Consumo de Oxígeno , Rendimiento Físico Funcional , Muslo , Factores de Tiempo , Vasodilatación
4.
Nanomedicine ; 24: 102138, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31846739

RESUMEN

Nanoparticles play an important role in biomedicine. We have developed a method for size-controlled synthesis of photomagnetic Prussian blue nanocubes (PBNCs) using superparamagnetic iron oxide nanoparticles (SPIONs) as precursors. The developed PBNCs have magnetic and optical properties desired in many biomedical diagnostic and therapeutic applications. Specifically, the size-tunable photomagnetic PBNCs exhibit high magnetic saturation, strong optical absorption with a peak at approximately 700 nm, and superior photostability. Our studies demonstrate that PBNCs can be used as MRI and photoacoustic imaging contrast agents in vivo. We also showed the utility of PBNCs for labeling and magnetic manipulation of cells. Dual magnetic and optical properties, together with excellent biocompatibility, render PBNCs an attractive contrast agent for both diagnostic and therapeutic applications. The use SPIONs as precursors for PBNCs provides flexibility and allows researchers to design theranostic agents according to required particle size, optical, and magnetic properties.


Asunto(s)
Medios de Contraste/química , Compuestos Férricos/química , Ferrocianuros/química , Nanopartículas del Metal/química , Animales , Femenino , Imagen por Resonancia Magnética/métodos , Nanopartículas del Metal/ultraestructura , Ratones , Microscopía Electrónica de Transmisión , Técnicas Fotoacústicas , Espectrometría por Rayos X
5.
Artículo en Inglés | MEDLINE | ID: mdl-29887658

RESUMEN

Gradient coils in magnetic resonance imaging do not produce perfectly linear gradient fields. For diffusion imaging, the field nonlinearities cause the amplitude and direction of the applied diffusion gradients to vary over the field of view. This leads to site- and scan-specific systematic errors in estimated diffusion parameters such as diffusivity and anisotropy, reducing reliability especially in studies that take place over multiple sites. These errors can be substantially reduced if the actual scanner-specific gradient coil magnetic fields are known. The nonlinearity of the coil fields is measured by scanner manufacturers and used internally for geometric corrections, but obtaining and using the information for a specific scanner may be impractical for many sites that operate without special-purpose local engineering and research support. We have implemented an empirical field-mapping procedure using a large phantom combined with a solid harmonic approximation to the coil fields that is simple to perform and apply. Here we describe the accuracy and precision of the approach in reproducing manufacturer gold standard field maps and in reducing spatially varying errors in quantitative diffusion imaging for a specific scanner. Before correction, median B value error ranged from 33 - 41 relative to manufacturer specification at 100 mm from isocenter; correction reduced this to 0 - 4. On-axis spatial variation in the estimated mean diffusivity of an isotropic phantom was 2.2% - 4.1% within 60 mm of isocenter before correction, 0.5% - 1.6% after. Expected fractional anisotropy in the phantom was 0; highest estimated fractional anisotropy within 60 mm of isocenter was reduced from 0.024 to 0.012 in the phase encoding direction (48% reduction) and from 0.020 to 0.006 in the frequency encoding direction (72% reduction).

6.
Artículo en Inglés | MEDLINE | ID: mdl-29887662

RESUMEN

An understanding of the bias and variance of diffusion weighted magnetic resonance imaging (DW-MRI) acquisitions across scanners, study sites, or over time is essential for the incorporation of multiple data sources into a single clinical study. Studies that combine samples from various sites may be introducing confounding due to site-specific artifacts and patterns. Differences in bias and variance across sites may render the scans incomparable, and, without correction, any inferences obtained from these data are misleading. We present an analysis of the bias and variance of scans of the same subjects across different sites and evaluate their impact on statistical analyses. In previous work, we presented a simulation extrapolation (SIMEX) technique for bias estimation as well as a wild bootstrap technique for variance estimation in metrics obtained from a Q-ball imaging (QBI) reconstruction of empirical high angular resolution diffusion imaging (HARDI) data. We now apply those techniques to data acquired from 5 healthy volunteers on 3 independent scanners under closely matched acquisition protocols. The bias and variance of GFA measurements were estimated on a voxel-wise basis for each scan and compared across study sites to identify site-specific differences. Further, we provide model recommendations that can be used to determine the extent of the impact of bias and variance as well as aspects of the analysis to account for these differences. We include a decision tree to help researchers determine if model adjustments are necessary based on the bias and variance results.

7.
Inorg Chem ; 56(11): 6429-6437, 2017 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-28537705

RESUMEN

19F magnetic resonance imaging (MRI), an emerging modality in biomedical imaging, has shown promise for in vitro and in vivo preclinical studies. Here we present a series of fluorinated Cu(II)ATSM derivatives for potential use as 19F magnetic resonance agents for sensing cellular hypoxia. The synthesized complexes feature a hypoxia-targeting Cu2+ coordination core, nine equivalent fluorine atoms connected via a variable-length poly(ethylene glycol) linker. Introduction of the fluorine moiety maintains the planar coordination geometry of the Cu2+ center, while the linker length modulates the Cu2+/+ reduction potential, 19F NMR relaxation properties, and lipophilicity. In particular, the 19F NMR relaxation properties were quantitatively evaluated by the Solomon-Bloembergen model, revealing a regular pattern of relaxation enhancement tuned by the distance between Cu2+ and F atoms. Finally, the potential utility of these complexes for sensing reductive environments was demonstrated using both 19F MR phantom imaging and 19F NMR, including experiments in intact live cells.


Asunto(s)
Materiales Biocompatibles/química , Complejos de Coordinación/química , Cobre/química , Imagen por Resonancia Magnética con Fluor-19 , Sondas Moleculares/química , Materiales Biocompatibles/síntesis química , Materiales Biocompatibles/farmacología , Hipoxia de la Célula/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Complejos de Coordinación/síntesis química , Complejos de Coordinación/farmacología , Relación Dosis-Respuesta a Droga , Humanos , Células MCF-7 , Modelos Moleculares , Sondas Moleculares/síntesis química , Sondas Moleculares/farmacología , Estructura Molecular , Oxidación-Reducción , Relación Estructura-Actividad
8.
J Neurophysiol ; 117(3): 1395-1406, 2017 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28053246

RESUMEN

Orientation selectivity in primary visual cortex (V1) has been proposed to reflect a canonical computation performed by the neocortical circuitry. Although orientation selectivity has been reported in all mammals examined to date, the degree of selectivity and the functional organization of selectivity vary across mammalian clades. The differences in degree of orientation selectivity are large, from reports in marsupials that only a small subset of neurons are selective to studies in carnivores, in which it is rare to find a neuron lacking selectivity. Furthermore, the functional organization in cortex varies in that the primate and carnivore V1 is characterized by an organization in which nearby neurons share orientation preference while other mammals such as rodents and lagomorphs either lack or have only extremely weak clustering. To gain insight into the evolutionary emergence of orientation selectivity, we examined the nine-banded armadillo, a species within the early placental clade Xenarthra. Here we use a combination of neuroimaging, histological, and electrophysiological methods to identify the retinofugal pathways, locate V1, and for the first time examine the functional properties of V1 neurons in the armadillo (Dasypus novemcinctus) V1. Individual neurons were strongly sensitive to the orientation and often the direction of drifting gratings. We uncovered a wide range of orientation preferences but found a bias for horizontal gratings. The presence of strong orientation selectivity in armadillos suggests that the circuitry responsible for this computation is common to all placental mammals.NEW & NOTEWORTHY The current study shows that armadillo primary visual cortex (V1) neurons share the signature properties of V1 neurons of primates, carnivorans, and rodents. Furthermore, these neurons exhibit a degree of selectivity for stimulus orientation and motion direction similar to that found in primate V1. Our findings in armadillo visual cortex suggest that the functional properties of V1 neurons emerged early in the mammalian lineage, near the time of the divergence of marsupials.


Asunto(s)
Potenciales de Acción/fisiología , Armadillos/fisiología , Neuronas/fisiología , Orientación/fisiología , Corteza Visual/citología , Corteza Visual/fisiología , Animales , Armadillos/anatomía & histología , Mapeo Encefálico , Imagen de Difusión Tensora , Femenino , Lateralidad Funcional , Cuerpos Geniculados/diagnóstico por imagen , Cuerpos Geniculados/fisiología , Masculino , Estimulación Luminosa , Psicofísica , Corteza Visual/diagnóstico por imagen , Vías Visuales/diagnóstico por imagen , Vías Visuales/fisiología
9.
Chem Commun (Camb) ; 52(96): 13885-13888, 2016 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-27841393

RESUMEN

A fluorinated, air-stable cobalt(ii) complex serves as a turn-on 19F magnetic resonance imaging (MRI) tracer for reactive oxygen species including H2O2. Upon oxidation with H2O2, the complex converts from paramagnetic high spin CoII to diamagnetic low spin CoIII resulting in a chemical shift change and enhancement in 19F NMR signal. Further, the oxidation can be reversed in the presence of reductant Na2S2O4. The turn-on response is demonstrated by 19F MRI, characterized by a ∼2-3 fold enhancement in signal.


Asunto(s)
Cobalto/química , Colorantes Fluorescentes/química , Imagen por Resonancia Magnética , Compuestos Organometálicos/química , Especies Reactivas de Oxígeno/análisis , Radioisótopos de Flúor , Estructura Molecular
10.
PLoS One ; 11(2): e0149744, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26901881

RESUMEN

INTRODUCTION: This pilot study developed techniques to perform Magnetic Resonance Imaging (MRI) of specific fat deposition in 18 children (age 18 months to 4 years). METHODS: The children engaged in a series of practice tests to become acclimated to the scanner noises, reduce claustrophobia, and rehearse holding still for a set time. The practice tests assessed if the child could remain still for two minutes while watching a video, first while lying on a blanket, second, on the blanket with headphones, and third, in the mock scanner. The children who passed the three practice tests were then scanned with a 3T Siemens Skyra magnet. Abdominal fat distribution (region of interest (ROI) from the top of the ileac crest to the bottom of the ribcage) volume was measured using 2-point DIXON technique. This region was chosen to give an indication of the body composition around the liver. RESULTS: Twelve out of eighteen participants successfully completed the actual MRI scan. Chi-squared test showed no significant difference between male and female pass-fail rates. The median age of completed scans was 36 months, whereas the median age for children unable to complete a scan was 28 months. The average total trunk fat was 240.9±85.2mL and the average total VAT was 37.7±25.9mLand liver fat was not quantifiable due to physiological motion. Several strategies (modeling, videos, and incentives) were identified to improve pediatric imaging in different age ranges. CONCLUSION: Using an age-specific and tailored protocol, we were able to successfully use MRI for fat imaging in a majority of young children. Development of such protocols enables researchers to better understand the etiology of fat deposition in young children, which can be used to aid in the prevention and treatment of adiposity.


Asunto(s)
Tejido Adiposo , Imagen por Resonancia Magnética , Grasa Abdominal , Adiposidad , Factores de Edad , Preescolar , Femenino , Humanos , Lactante , Imagen por Resonancia Magnética/métodos , Masculino , Grasa Subcutánea
11.
Nat Commun ; 6: 8885, 2015 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-26648521

RESUMEN

Psychiatric disorders are characterized by major fluctuations in psychological function over the course of weeks and months, but the dynamic characteristics of brain function over this timescale in healthy individuals are unknown. Here, as a proof of concept to address this question, we present the MyConnectome project. An intensive phenome-wide assessment of a single human was performed over a period of 18 months, including functional and structural brain connectivity using magnetic resonance imaging, psychological function and physical health, gene expression and metabolomics. A reproducible analysis workflow is provided, along with open access to the data and an online browser for results. We demonstrate dynamic changes in brain connectivity over the timescales of days to months, and relations between brain connectivity, gene expression and metabolites. This resource can serve as a testbed to study the joint dynamics of human brain and metabolic function over time, an approach that is critical for the development of precision medicine strategies for brain disorders.


Asunto(s)
Encéfalo/fisiología , Vías Nerviosas , Encéfalo/diagnóstico por imagen , Estudios de Seguimiento , Expresión Génica , Redes Reguladoras de Genes , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Fenotipo , Radiografía
12.
Magn Reson Imaging ; 31(2): 227-34, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22925604

RESUMEN

Diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) is a relatively new diffusion-based pulse sequence that produces positron emission tomography (PET) with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose ((18)F-FDG)-like images. We tested the feasibility of DWIBS in detecting peritoneal ovarian cancer in a syngeneic mouse model. Female C57BL/6 mice were injected intraperitoneally with ID8 murine ovarian carcinoma cells. After 11 weeks, the abdomen was imaged by DWIBS. A respiratory gating diffusion-weighted spin-echo echo-planar imaging in abdomen was used (imaging parameters of field of view of 47×47 mm(2), matrix size of 64×64 zero-filled to 256×256 and b-value of 1500 s/mm(2)). We also performed FDG microPET as the reference standard. For comparison of the correlating surface areas of tumor foci on both DWIBS and FDG microPET imaging, two-dimensional region-of-interest (ROI) analysis was performed, and correlation between the two modalities was determined. Mice were also subjected to macroscopic examination for tumor location and pathology after imaging. DWIBS in all mice depicted the tumors as abnormal high signal intensity. The results show that the ROI analysis of correlating lesions reveals relatively high correlation (r²=0.7296) and significant difference (P=.021) between DWIBS and FDG microPET. These results demonstrate that DWIBS has the potential for detecting peritoneal dissemination of ovarian cancer. Nonetheless, due to low ratios of image signal-to-noise and motion artifacts, DWIBS can be limited for lesions near the liver.


Asunto(s)
Carcinoma/diagnóstico , Carcinoma/patología , Neoplasias Ováricas/diagnóstico , Neoplasias Ováricas/patología , Animales , Imagen de Difusión por Resonancia Magnética/métodos , Femenino , Fluorodesoxiglucosa F18/farmacología , Imagen por Resonancia Magnética/métodos , Ratones , Ratones Endogámicos C57BL , Movimiento (Física) , Neoplasias Peritoneales/diagnóstico , Neoplasias Peritoneales/patología , Peritoneo/patología , Tomografía de Emisión de Positrones/métodos , Respiración , Microtomografía por Rayos X/métodos
13.
Magn Reson Med ; 59(2): 326-35, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18228592

RESUMEN

Models have been developed for the analysis of dynamic contrast-enhanced MRI (DCE-MRI) data that do not require direct measurements of the arterial input function; such methods are referred to as reference region models. These models typically return estimates of the volume transfer constant (K(trans)) and the extravascular extracellular volume fraction (v(e)). To date such models have assumed a linear relationship between the measured R(1) ( identical with 1/T(1)) and the concentration of contrast agent, a transformation referred to as the fast exchange limit, but this assumption is not valid for all concentrations of an agent. A theory for DCE-MRI reference region models which accounts for water exchange is presented, evaluated in simulations, and applied in tumor-bearing mice. Using reasonable parameter values, simulations show that the assumption of fast exchange can underestimate K(trans) and v(e) by up to 82% and 46%, respectively. By analyzing a large region of interest and a single voxel the new model can return parameters within approximately +/-10% and +/-25%, respectively, of their true values. Analysis of experimental data shows that the new approach returns K(trans) and v(e) values that are up to 90% and 73%, respectively, greater than conventional fast exchange analyses.


Asunto(s)
Agua Corporal/metabolismo , Medios de Contraste/farmacocinética , Gadolinio DTPA/farmacocinética , Imagen por Resonancia Magnética/métodos , Neoplasias Mamarias Experimentales/metabolismo , Algoritmos , Animales , Simulación por Computador , Femenino , Procesamiento de Imagen Asistido por Computador , Ratones , Modelos Teóricos
14.
J Magn Reson Imaging ; 24(5): 1140-7, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17024660

RESUMEN

PURPOSE: To test the repeatability of a reference region (RR) model for the analysis of dynamic contrast-enhanced MRI (DCE-MRI) in a mouse model of cancer at high field. MATERIALS AND METHODS: Seven mice were injected with 10(6) 4T1 mammary carcinoma cells and imaged eight to 10 days later on a Varian 7.0T scanner. Two DCE-MRI studies were performed for each mouse (separated by 2.5 hours). The RR model was used to analyze the data, and returned estimates on the perfusion-permeability index (Ktrans) for the RR and the tissue of interest (TOI), as well as the extravascular extracellular volume fraction (ve) for the TOI. RESULTS: When the first injection was compared with the second injection, all parameters tested were highly correlated (r2=0.90, 0.62, 0.82 for the RR Ktrans, TOI Ktrans, and TOI ve, respectively, with P<0.001 for all). To observe a statistically significant change (at the 5% level) in a treatment study with seven animals in each group, log10 changes of 0.084 and 0.077 in the tumor Ktrans and ve, respectively, are required. CONCLUSION: If a reliable arterial input function (AIF) is unavailable, the RR model is a reasonable alternative to measuring MRI contrast-agent (CA) kinetics in mouse models of cancer at high field.


Asunto(s)
Algoritmos , Gadolinio DTPA , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias Mamarias Animales/diagnóstico , Animales , Simulación por Computador , Medios de Contraste , Femenino , Ratones , Modelos Biológicos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
Chem Commun (Camb) ; (43): 5444-6, 2005 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-16261241

RESUMEN

(C5Me5R)2Ta2Cl4 (d2-d2) disproportionates under dinitrogen to [(C5Me4R)TaCl2]2(mu-N2) and the D3h cluster cation (C5Me4R)3Ta3(mu-Cl)6+ with anionic (C5Me4R)TaCl4-.

16.
Magn Reson Imaging ; 23(4): 519-29, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15919597

RESUMEN

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can assess tumor perfusion, microvascular vessel wall permeability and extravascular-extracellular volume fraction. Analysis of DCE-MRI data is usually based on indicator dilution theory that requires knowledge of the concentration of the contrast agent in the blood plasma, the arterial input function (AIF). A method is presented that compares the tissues of interest (TOI) curve shape to that of a reference region (RR), thereby eliminating the need for direct AIF measurement. By assigning literature values for Ktrans (the blood perfusion-vessel permeability product) and v(e) (extravascular-extracellular volume fraction) in a reference tissue, it is possible to extract the Ktrans and v(e) values for a TOI without knowledge of the AIF. The operational RR equation for DCE-MRI analysis is derived, and its sensitivity to noise and incorrect assignment of the RR parameters is tested via simulations. The method is robust at noise levels of 10%, returning accurate (+/-20% in the worst case) and precise (+/-15% in the worst case) values. Errors in the TOI Ktrans and v(e) values scale approximately linearly with the errors in the assigned RR Ktrans and v(e) values. The methodology is then applied to a Lewis Lung Carcinoma mouse tumor model. A slowly enhancing TOI yielded Ktrans=0.039+/-0.002 min-1 and v(e)=0.46+/-0.01, while a rapidly enhancing region yielded Ktrans=0.35+/-0.05 min-1 and v(e)=0.31+/-0.01. Parametric Ktrans and v(e) mappings manifested a tumor periphery with elevated Ktrans (>0.30 min-1) and v(e) (>0.30) values. The main advantage of the RR approach is that it allows for quantitative assessment of tissue properties without having to obtain high temporal resolution images to characterize an AIF. This allows for acquiring images with higher spatial resolution and/or SNR, and therefore, increased ability to probe tissue heterogeneity.


Asunto(s)
Medios de Contraste/farmacocinética , Gadolinio DTPA/farmacocinética , Imagen por Resonancia Magnética/métodos , Neoplasias Experimentales/irrigación sanguínea , Algoritmos , Animales , Simulación por Computador , Miembro Posterior , Procesamiento de Imagen Asistido por Computador , Masculino , Ratones , Ratones Endogámicos BALB C , Sensibilidad y Especificidad
17.
J Am Chem Soc ; 125(7): 1688-9, 2003 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-12580580

RESUMEN

Reduction of the organoditantalum allene complex (eta-C5Me4R)2Ta2(mu-X)X3(mu-eta1,eta3-C3H4) (R = Me (Cp*), Et; X = Cl, Br) with sodium amalgam leads to the propynylidene complex (eta-C5Me4R)2Ta2(mu-H)2X2(mu-HCCCH) by a formal double 1,3-C-H activation of the allene ligand. The solid-state molecular structure contains a planar HCCCH ligand bridging, in parallel coordination mode, the two tantalum atoms, with the HCCCH and Ta atoms coplanar. Key structural features are a Ta-Ta distance of 2.8817(7) A, propynylidene C-C-C angle of 153.7(13) degrees , C-C distance of 1.370(8) A, Ta-C(central) distance of 2.194(9) A, and Ta-C(terminal) distance of 1.970(9) A. Molecular orbital calculations on the complex at the RHF/SBK(d) and B3LYP/LanL2dz levels of theory demonstrate that the propynylidene ligand is best viewed formally as an allenediylidene(4-) ligand bonded to two d0 tantalum atoms via two Ta=C(terminal) double bonds and an unusual three-center, two-electron bridge bond involving both tantalum atoms and a lone pair on the planar, tetracoordinate central carbon. There is no net Ta-Ta bonding based on the orbital analysis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...