Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Mol Biosci ; 11: 1341108, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38784665

RESUMEN

Introduction: Normothermic ex vivo kidney perfusion (NEVKP) is designed to replicate physiological conditions to improve graft outcomes. A comparison of the impact of hypothermic and normothermic preservation techniques on graft quality was performed by lipidomic profiling using solid-phase microextraction (SPME) chemical biopsy as a minimally invasive sampling approach. Methods: Direct kidney sampling was conducted using SPME probes coated with a mixed-mode extraction phase in a porcine autotransplantation model of the renal donor after cardiac death, comparing three preservation methods: static cold storage (SCS), NEVKP, and hypothermic machine perfusion (HMP). The lipidomic analysis was done using ultra-high-performance liquid chromatography coupled with a Q-Exactive Focus Orbitrap mass spectrometer. Results: Chemometric analysis showed that the NEVLP group was separated from SCS and HMP groups. Further in-depth analyses indicated significantly (p < 0.05, VIP > 1) higher levels of acylcarnitines, phosphocholines, ether-linked and longer-chain phosphoethanolamines, triacylglycerols and most lysophosphocholines and lysophosphoethanolamines in the hypothermic preservation group. The results showed that the preservation temperature has a more significant impact on the lipidomic profile of the kidney than the preservation method's mechanical characteristics. Conclusion: Higher levels of lipids detected in the hypothermic preservation group may be related to ischemia-reperfusion injury, mitochondrial dysfunction, pro-inflammatory effect, and oxidative stress. Obtained results suggest the NEVKP method's beneficial effect on graft function and confirm that SPME chemical biopsy enables low-invasive and repeated sampling of the same tissue, allowing tracking alterations in the graft throughout the entire transplantation procedure.

2.
Transl Res ; 267: 79-90, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38052298

RESUMEN

Transplant centers are currently facing a lack of tools to ensure adequate evaluation of the quality of the available organs, as well as a significant shortage of kidney donors. Therefore, efforts are being made to facilitate the effective use of available organs and expand the donor pool, particularly with expanded criteria donors. Fulfilling a need, we aim to present an innovative analytical method based on solid-phase microextraction (SPME) - chemical biopsy. In order to track changes affecting the organ throughout the entire transplant procedure, porcine kidneys were subjected to multiple samplings at various time points. The application of small-diameter SPME probes assured the minimal invasiveness of the procedure. Porcine model kidney autotransplantation was executed for the purpose of simulating two types of donor scenarios: donors with a beating heart (HBD) and donors after cardiac death (DCD). All renal grafts were exposed to continuous normothermic ex vivo perfusion. Following metabolomic and lipidomic profiling using high-performance liquid chromatography coupled to a mass spectrometer, we observed differences in the profiles of HBD and DCD kidneys. The alterations were predominantly related to energy and glucose metabolism, and differences in the levels of essential amino acids, purine nucleosides, lysophosphocholines, phosphoethanolamines, and triacylglycerols were noticed. Our results indicate the potential of implementing chemical biopsy in the evaluation of graft quality and monitoring of renal function during perfusion.


Asunto(s)
Riñón , Lipidómica , Porcinos , Animales , Humanos , Donantes de Tejidos , Muerte , Perfusión/métodos , Supervivencia de Injerto
3.
Int J Mol Sci ; 24(3)2023 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-36768452

RESUMEN

The development of surgical techniques, immunosuppressive strategies and new organ preservation methods have meant that transplant centers have to face the problem of an insufficient number of organs for transplantation concerning the constantly growing demand. Therefore, using organs from expanded criteria donors and developing new analytical solutions to find parameters or compounds that would allow a more efficient assessment of organ quality before transplantation are options for meeting this challenge. This study proposed bile metabolomic analysis to evaluate liver metabolism and biliary tract function depending on the organ preservation method and degree of warm ischemia time. The analyses were performed on solid-phase microextraction-prepared bile samples from porcine model donors with mild (heart beating donor [HBD]) and moderate warm ischemia (donation after circulatory death [DCD]) grafts subjected to static cold storage (SCS) or normothermic ex vivo liver perfusion (NEVLP) before transplantation. Bile produced in the SCS-preserved livers was characterized by increased levels of metabolites such as chenodeoxycholic acid, arachidonic acid and 5S-hydroxyeicosatetraeonic acid, as well as saturated and monounsaturated lysophosphatidylcholines (LPC). Such changes may be associated with differences in the bile acid synthesis pathways and organ inflammation. Moreover, it has been shown that NEVLP reduced the negative effect of ischemia on organ function. A linear relationship was observed between levels of lipids from the LPC group and the time of organ ischemia. This study identified metabolites worth considering as potential markers of changes occurring in preserved grafts.


Asunto(s)
Sistema Biliar , Trasplante de Hígado , Daño por Reperfusión , Porcinos , Animales , Preservación de Órganos/métodos , Trasplante de Hígado/métodos , Daño por Reperfusión/metabolismo , Perfusión/métodos , Sistema Biliar/metabolismo , Hígado/metabolismo , Isquemia/metabolismo , Isquemia Tibia , Metaboloma
4.
J Clin Med ; 11(3)2022 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-35159939

RESUMEN

The number of patients placed on kidney transplant waiting lists is rapidly increasing, resulting in a growing gap between organ demand and the availability of kidneys for transplantation. This organ shortage has forced medical professionals to utilize marginal kidneys from expanded criteria donors (ECD) to broaden the donor pool and shorten wait times for patients with end-stage renal disease. However, recipients of ECD kidney grafts tend to have worse outcomes compared to those receiving organs from standard criteria donors (SCD), specifically increased risks of delayed graft function (DGF) and primary nonfunction incidence. Thus, representative methods for graft-quality assessment are strongly needed, especially for ECDs. Currently, graft-quality evaluation is limited to interpreting the donor's recent laboratory tests, clinical risk scores, the visual evaluation of the organ, and, in some cases, a biopsy and perfusion parameters. The last few years have seen the emergence of many new technologies designed to examine organ function, including new imaging techniques, transcriptomics, genomics, proteomics, metabolomics, lipidomics, and new solutions in organ perfusion, which has enabled a deeper understanding of the complex mechanisms associated with ischemia-reperfusion injury (IRI), inflammatory process, and graft rejection. This review summarizes and assesses the strengths and weaknesses of current conventional diagnostic methods and a wide range of new potential strategies (from the last five years) with respect to donor graft-quality assessment, the identification of IRI, perfusion control, and the prediction of DGF.

5.
J Pharm Anal ; 11(5): 667-674, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34765281

RESUMEN

Solid phase microextraction (SPME) in combination with high-resolution mass spectrometry was employed for the determination of metabolomic profile of mouse melanoma growth within in vitro 2D, in vitro 3D, and in vivo models. Such multi-model approach had never been investigated before. Due to the low-invasiveness of SPME, it was possible to perform time-course analysis, which allowed building time profile of biochemical reactions in the studied material. Such approach does not require the multiplication of samples as subsequent analyses are performed from the very same cell culture or from the same individual. SPME already reduces the number of animals required for experiment; therefore, it is with good concordance with the 3Rs rule (replacement, reduction, and refinement). Among tested models, the largest number of compounds was found within the in vitro 2D cell culture model, while in vivo and in vitro 3D models had the lowest number of detected compounds. These results may be connected with a higher metabolic rate, as well as lower integrity of the in vitro 2D model compared to the in vitro 3D model resulting in a lower number of compounds released into medium in the latter model. In terms of in vitro-in vivo extrapolation, the in vitro 2D model performed more similar to in vivo model compared to in vitro 3D model; however, it might have been due to the fact that only compounds secreted to medium were investigated. Thus, in further experiments to obtain full metabolome information, the intraspheroidal assessment or spheroid dissociation would be necessary.

6.
Sci Rep ; 11(1): 19522, 2021 09 30.
Artículo en Inglés | MEDLINE | ID: mdl-34593948

RESUMEN

It is extremely challenging to perform chemical analyses of the brain, particularly in humans, due to the restricted access to this organ. Imaging techniques are the primary approach used in clinical practice, but they only provide limited information about brain chemistry. Solid-phase microextraction (SPME) has been presented recently as a chemical biopsy tool for the study of animal brains. The current work demonstrates for the first time the use of SPME for the spatially resolved sampling of the human brain in vivo. Specially designed multi-probe sampling device was used to simultaneously extract metabolites from the white and grey matter of patients undergoing brain tumor biopsies. Samples were collected by inserting the probes along the planned trajectory of the biopsy needle prior to the procedure, which was followed by metabolomic and lipidomic analyses. The results revealed that studied brain structures were predominantly composed of lipids, while the concentration and diversity of detected metabolites was higher in white than in grey matter. Although the small number of participants in this research precluded conclusions of a biological nature, the results highlight the advantages of the proposed SPME approach, as well as disadvantages that should be addressed in future studies.


Asunto(s)
Biopsia/instrumentación , Química Encefálica , Encéfalo/metabolismo , Metabolómica/instrumentación , Biopsia/métodos , Cromatografía Liquida , Humanos , Lipidómica/instrumentación , Lipidómica/métodos , Espectrometría de Masas , Metabolómica/métodos
7.
Molecules ; 26(8)2021 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-33920347

RESUMEN

Bladder cancer (BC) is a common malignancy of the urinary system and a leading cause of death worldwide. In this work, untargeted metabolomic profiling of biological fluids is presented as a non-invasive tool for bladder cancer biomarker discovery as a first step towards developing superior methods for detection, treatment, and prevention well as to further our current understanding of this disease. In this study, urine samples from 24 healthy volunteers and 24 BC patients were subjected to metabolomic profiling using high throughput solid-phase microextraction (SPME) in thin-film format and reversed-phase high-performance liquid chromatography coupled with a Q Exactive Focus Orbitrap mass spectrometer. The chemometric analysis enabled the selection of metabolites contributing to the observed separation of BC patients from the control group. Relevant differences were demonstrated for phenylalanine metabolism compounds, i.e., benzoic acid, hippuric acid, and 4-hydroxycinnamic acid. Furthermore, compounds involved in the metabolism of histidine, beta-alanine, and glycerophospholipids were also identified. Thin-film SPME can be efficiently used as an alternative approach to other traditional urine sample preparation methods, demonstrating the SPME technique as a simple and efficient tool for urinary metabolomics research. Moreover, this study's results may support a better understanding of bladder cancer development and progression mechanisms.


Asunto(s)
Metaboloma , Metabolómica/métodos , Neoplasias de la Vejiga Urinaria/orina , Anciano , Ácido Benzoico/orina , Estudios de Casos y Controles , Cromatografía Liquida , Ácidos Cumáricos/orina , Femenino , Glicerofosfolípidos/orina , Hipuratos/orina , Histidina/orina , Humanos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Fenilalanina/metabolismo , Microextracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem , Vejiga Urinaria/metabolismo , Vejiga Urinaria/patología , Neoplasias de la Vejiga Urinaria/diagnóstico , Neoplasias de la Vejiga Urinaria/patología , beta-Alanina/orina
8.
Int J Mol Sci ; 21(23)2020 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-33260768

RESUMEN

A new series of hybrid compounds with tropinone and thiazole rings in the structure was designed and synthesized as potential anticancer agents. They were tested against human multiple myeloma (RPMI 8226), lung carcinoma (A549), breast adenocarcinoma (MDA-MB-231), and mouse skin melanoma (B16-F10) cell lines. Toxicity was tested on human normal skin fibroblasts (HSF) and normal colon fibroblasts (CCD-18Co). The growth inhibition mechanism of the most active derivative was analyzed through investigation of its effect on the distribution of cell cycle phases and ability to induce apoptosis and necrosis in RPMI 8226 and A549 cancer cells. The tyrosinase inhibitory potential was assessed, followed by molecular docking studies. Compounds 3a-3h show high anticancer activity against MDA-MB-231 and B16-F10 cell lines with IC50 values of 1.51-3.03 µM. Moreover, the cytotoxic activity of the investigated compounds against HSF and CCD-18Co cells was 8-70 times lower than against the cancer cells or no toxicity was shown in our tests, with derivative 3a being particularly successful. The mechanism of action of compound 3a in RPMI 8226 cell was shown to be through induction of cell death through apoptosis. The derivatives show ability to inhibit the tyrosinase activity with a mixed mechanism of inhibition. The final molecular docking results showed for IC50 distinct correlation with experiment.


Asunto(s)
Antineoplásicos/síntesis química , Antineoplásicos/farmacología , Teoría Funcional de la Densidad , Simulación del Acoplamiento Molecular , Monofenol Monooxigenasa/antagonistas & inhibidores , Tropanos/síntesis química , Tropanos/farmacología , Animales , Apoptosis/efectos de los fármacos , Ciclo Celular/efectos de los fármacos , Línea Celular Tumoral , Proliferación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Quimioinformática , Humanos , Concentración 50 Inhibidora , Ratones , Electricidad Estática , Termodinámica
9.
J Vis Exp ; (160)2020 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-32628165

RESUMEN

Kidney transplantation is a life-saving treatment for a large number of people with end-stage renal dysfunction worldwide. The procedure is associated with an increased survival rate and greater quality of patient's life when compared to conventional dialysis. Regrettably, transplantology suffers from a lack of reliable methods for organ quality assessment. Standard diagnostic techniques are limited to macroscopic appearance inspection or invasive tissue biopsy, which do not provide comprehensive information about the graft. The proposed protocol aims to introduce solid phase microextraction (SPME) as an ideal analytical method for comprehensive metabolomics and lipidomic analysis of all low molecular compounds present in kidneys allocated for transplantation. The small size of the SPME probe enables performance of a chemical biopsy, which enables extraction of metabolites directly from the organ without any tissue collection. The minimum invasiveness of the method permits execution of multiple analyses over time: directly after organ harvesting, during its preservation, and immediately after revascularization at the recipient's body. It is hypothesized that the combination of this novel sampling method with a high-resolution mass spectrometer will allow for discrimination of a set of characteristic compounds that could serve as biological markers of graft quality and indicators of possible development of organ dysfunction.


Asunto(s)
Trasplante de Riñón/normas , Metabolómica , Animales , Biopsia , Cromatografía Liquida , Lipidómica , Espectrometría de Masas , Análisis de Componente Principal , Control de Calidad , Microextracción en Fase Sólida
10.
J Sep Sci ; 43(9-10): 1867-1878, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32068348

RESUMEN

The limiting factor in conventional quality assessments of transplanted organs, namely the invasiveness of tissue sample collection, has prompted much research on the field of transplantology to focus on the development of alternative evaluation methods of organ quality. In the present project, we undertake the challenge to address the need for a new analytical solution for graft quality assessments by using a novel metabolomic diagnostic protocol based on low-invasive solid-phase microextraction. Solid-phase microextraction probes of ca. 0.2 mm coated with 4 mm long mixed-mode extraction phase were inserted into rabbit kidneys immediately following euthanasia and after 2, 4, 6, and 21 h of preservation. Liquid chromatography-mass spectrometry analysis of the extracts was performed with the use of a reversed phase column and a Q-Exactive Focus mass spectrometer operated in positive ionization mode. Statistical analysis of significantly changing compounds revealed metabolic profile changes in kidneys induced by ischemia and oxidative stress as a function of the duration of cold storage. The most pronounced alterations were reflected in levels of essential amino acids and purine nucleosides. Our findings demonstrate that the proposed approach may be successfully used to monitor changes in the metabolic profile of organs over time of preservation.


Asunto(s)
Isquemia/metabolismo , Riñón/metabolismo , Microextracción en Fase Sólida , Aminoácidos/análisis , Animales , Cromatografía Liquida , Isquemia/patología , Riñón/patología , Espectrometría de Masas , Estrés Oxidativo , Nucleósidos de Purina/análisis , Conejos
11.
Eur J Med Chem ; 175: 162-171, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31082763

RESUMEN

We have designed novel tropinone-thiazole derivatives that showed high antiproliferative activity against a variety of cancer cell lines via caspase 3/7 activation mechanism. Among the derivatives, compounds 3b-3h were found to exhibit high activity against human leukemia (MV4-11), human lung carcinoma (A549), human breast carcinoma (MCF-7), and skin melanoma (B16-F10) cancer cell lines, with IC50 values of 5.43-11.06 µM. The lead compound 3g increases caspase 3/7 activity in A549 cells 25 times more than the control, and 2 times more than reference drug camptothecin. We have also found that tropinone-thiazole derivatives exhibit high tyrosinase inhibitory activity. The lead compounds 3g and 3h showed tyrosinase inhibition effect, with IC50 values 3.22 and 3.51 µM, respectively. These inhibitory activities are 22 times higher than the activity of kojic acid (IC50 72.27 µM) and 120 times higher than activity of ascorbic acid (IC50 386.5 µM). For compounds 3g and 3h, the experimentally determined lipophilicity correlates very well with their enzymatic activities. These data suggest that presented compounds could constitute lead anticancer drug candidates.


Asunto(s)
Caspasa 3/metabolismo , Caspasa 7/farmacología , Proliferación Celular/efectos de los fármacos , Descubrimiento de Drogas , Activadores de Enzimas/farmacología , Inhibidores Enzimáticos/farmacología , Monofenol Monooxigenasa/antagonistas & inhibidores , Tiazoles/química , Tropanos/química , Células 3T3 , Animales , Espectroscopía de Resonancia Magnética con Carbono-13 , Caspasa 7/química , Línea Celular Tumoral , Cromatografía Liquida/métodos , Ensayos de Selección de Medicamentos Antitumorales , Activadores de Enzimas/química , Inhibidores Enzimáticos/química , Humanos , Concentración 50 Inhibidora , Ratones , Ratones Endogámicos BALB C , Espectroscopía de Protones por Resonancia Magnética , Espectrometría de Masa por Ionización de Electrospray/métodos , Relación Estructura-Actividad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...