Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Diagnostics (Basel) ; 14(17)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39272698

RESUMEN

BACKGROUND: The HHUS market is very complex due to a multitude of equipment variants and several different device manufacturers. Only a few studies have compared different HHUS devices under clinical conditions. We conducted a comprehensive prospective observer study with a direct comparison of nine different HHUS devices in terms of B-scan quality, device handling, and software features under abdominal imaging conditions. METHODS: Nine different HHUS devices (Butterfly iQ+, Clarius C3HD3, D5CL Microvue, Philips Lumify, SonoEye Chison, SonoSite iViz, Mindray TE Air, GE Vscan Air, and Youkey Q7) were used in a prospective setting by a total of 12 experienced examiners on the same subjects in each case and then assessed using a detailed questionnaire regarding B-scan quality, handling, and usability of the software. The evaluation was carried out using a point scale (5 points: very good; 1 point: insufficient). RESULTS: In the overall evaluation, Vscan Air and SonoEye Chison achieved the best ratings. They achieved nominal ratings between "good" (4 points) and "very good" (5 points). Both devices differed significantly (p < 0.01) from the other seven devices tested. Among the HHUS devices, Clarius C3HD3 and Vscan Air achieved the best results for B-mode quality, D5CL Microvue achieved the best results for device handling, and SonoEye Chison and Vscan Air achieved the best results for software. CONCLUSIONS: This is the first comprehensive study to directly compare different HHUS devices in a head-to-head manner. While the majority of the tested devices demonstrated satisfactory performance, notable discrepancies were observed between them. In particular, the B-scan quality exhibited considerable variation, which may have implications for the clinical application of HHUS. The findings of this study can assist in the selection of an appropriate HHUS device for specific applications, considering the clinical objectives and acknowledging the inherent limitations.

2.
Diagnostics (Basel) ; 14(7)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38611692

RESUMEN

Prior to the curative resection of colorectal carcinoma (CRC) or pancreatic ductal adenocarcinoma (PDAC), the exclusion of hepatic metastasis using cross-sectional imaging is mandatory. The Doppler perfusion index (DPI) of the liver is a promising method for detecting occult liver metastases, but the underlying visceral duplex sonography is critically viewed in terms of its reproducibility. The aim of this study was to investigate systematically the reproducibility of the measured variables, the calculated blood flow, and the DPI. Between February and September 2023, two examinations were performed on 80 subjects within a period of 0-30 days and at two previously defined quality levels, aligned to the German standards of the DEGUM. Correlation analyses were carried out using Pearson's correlation coefficient (PCC) and the intraclass correlation coefficient (ICC). The diameters, blood flow, and DPI showed a high degree of agreement (PCC of 0.9 and ICC of 0.9 for AHP). Provided that a precise standard of procedure is adhered to, the Doppler examination of AHC, AHP, and PV yields very reproducible blood flows and DPI, which is a prerequisite for a comprehensive investigation of its prognostic value for the prediction of metachronous hepatic metastasis in the context of curatively treated CRC or PDAC.

3.
Clin Chem ; 54(6): 1076-9, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18509013

RESUMEN

BACKGROUND: Myeloperoxidase (MPO) has shown potential as a marker for cardiovascular disease. Limited studies have been published with a variety of sample types, resulting in a wide range of MPO values. Little is known or understood about the impact of collection tube type and preanalytical handling of specimens for MPO determination. METHOD: MPO concentration was determined by use of the ARCHITECT(R) MPO research use assay, which is currently under development. Samples were collected into multiple anticoagulant collection tubes from donors and patients presenting to the emergency department with symptoms of acute coronary syndromes. Whole blood was stored on ice or at room temperature for predetermined time periods. We also evaluated serum and plasma after centrifugation followed by storage at room temperature, 2-8 degrees C, and below -10 degrees C. RESULTS: Baseline sample concentrations were dependent on collection tube type as well as handling conditions. MPO concentrations were consistently higher in samples collected in serum and heparin plasma tubes than in samples in EDTA or citrate tubes. Spike recovery was acceptable in all sera and plasma tested, indicating that the increased MPO concentrations were not due directly to an anticoagulant interference. CONCLUSIONS: The collection tube type and preanalytical handling are critical for accurate and consistent MPO measurement. The preferred anticoagulant and tubes are the EDTA or EDTA plasma preparation tube. MPO concentrations in samples collected in these tubes are stable before centrifugation as whole blood as well as plasma after processing.


Asunto(s)
Recolección de Muestras de Sangre/métodos , Peroxidasa/sangre , Síndrome Coronario Agudo/diagnóstico , Recolección de Muestras de Sangre/instrumentación , Humanos , Temperatura , Factores de Tiempo
4.
Clin Chim Acta ; 393(2): 103-9, 2008 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-18423399

RESUMEN

BACKGROUND: A multitude of biomarkers have been suggested for early risk-assessment in patients admitted to the emergency department with suspected acute coronary syndromes. We used logistic regression synergistically with classification and regression tree (CART) analysis to define a multimarker strategy and the cut-off values and sequencing needed to optimize risk stratification in a low to moderate risk population of the emergency department. METHODS: 432 unselected patients (59.7+/-14.5 y, 60.4% male) admitted to the emergency department (ED) with acute coronary syndromes (ACS) were enrolled. Cardiac troponin I (cTnI), N-terminal pro-B-Type natriuretic peptide (NT-proBNP), high sensitivity C-reactive protein (hsCRP), placental growth factor (PlGF), lipoprotein-associated phospholipase A(2) (Lp-PLA(2)) and D-dimers were measured by immunoassay and whole blood choline (WBCHO) and plasma choline (PLCHO) were measured using LC/MS from baseline samples. Logistic regression and CART analysis were used to define the importance of the various biomarkers tested and to define their hierarchy with respect to the prediction of major adverse cardiac events (MACE; cardiac death, non-fatal MI, unstable angina, CHF requiring admission, urgent PCI and CABG) over the 42-day follow-up period. RESULTS: A combination of NT-proBNP, WBCHO and Lp-PLA2 with cutoffs identified by CART-analysis was optimal for risk-stratification and superior to all other possible combinations of markers. Increased concentrations of both NT-proBNP (>1400 ng/l) and WBCHO (>21 micromol/l) identified patients with very high risk (RR=2.4, 39% primary endpoint) while low concentrations of NT-proBNP (< or = 1400 ng/l), WBCHO (< or = 17 micromol/l) and LP-PLA2 (< or = 210 microg/l) indicated very low risk (0% primary endpoint). WBCHO > 17 micromol/l additionally identified a subgroup with intermediate risk (RR=3.0, 13.5% primary endpoint) in patients with NT-proBNP concentrations < or = 1400 ng/l. Troponin when increased was highly prognostic but was not often positive in this early cohort. CONCLUSIONS: A multimarker strategy defined synergistically by logistic regression and by classification and regression tree (CART) analysis can stratify patients into risk groups ranging from very low risk (0% MACE) to very high risk (39.5% MACE) based on admission values.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Biomarcadores/sangre , Síndrome Coronario Agudo/sangre , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Medición de Riesgo , Sensibilidad y Especificidad
5.
Stud Health Technol Inform ; 132: 493-5, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18391353

RESUMEN

While removing bone tissue of the mastoid, the facial nerve is at risk of being injured. In this contribution a model for nerve visualization in preoperative image data based on intraoperatively gained EMG signals is proposed. A neuro monitor can assist the surgeon locating and preserving the nerve. With the proposed model gained EMG signals can be spatially related to the patient resp. the image data. During navigation the detected nerve course will be visualized and hence permanently available for assessing the situs.


Asunto(s)
Electromiografía , Nervio Facial , Complicaciones Intraoperatorias/prevención & control , Cuidados Preoperatorios , Simulación por Computador , Alemania , Humanos , Apófisis Mastoides/cirugía , Administración de la Seguridad
6.
Clin Chem ; 54(3): 590-3, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18310145

RESUMEN

BACKGROUND: Choline is critical for a variety of biological functions and has been investigated as a biomarker for various pathological conditions including acute coronary syndrome. METHODS: A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was used to quantify choline in whole blood and plasma in freshly collected samples prepared with ultrafiltration or protein precipitation. We investigated the effects of preanalytical variables including types of anticoagulants and storage temperature and time. RESULTS: We observed no significant differences in whole-blood choline concentration in EDTA-anticoagulated vs heparin-anticoagulated samples: mean (SD) difference 0.9% (3.2%), P = 0.80. For plasma, choline concentrations with heparin in 5 of 12 volunteers were >10% higher than with EDTA, P = 0.01. One freeze-thaw cycle led to significant mean (SD) increases in choline concentrations in heparin whole blood, 19.3% (11.4%), P <0.01, and the effect was not significant for other sample types studied (P >0.33). For freshly collected samples stored at ambient temperature, choline concentrations in all types of samples increased with storage time. For EDTA whole blood, EDTA plasma, and heparin plasma, the choline concentration increased for the first 60 min and then stabilized. For heparin whole blood, the choline concentration continued to increase linearly with storage time for >4 h, at which time the choline concentrations were increased by approximately 50%. CONCLUSIONS: Sample collection, storage, and sample preparation procedures are critical for clinical measurements of choline in whole blood and plasma.


Asunto(s)
Colina/sangre , Anticoagulantes , Biomarcadores/sangre , Recolección de Muestras de Sangre , Cromatografía Liquida , Ácido Edético , Heparina , Humanos , Plasma , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem
7.
Clin Chim Acta ; 383(1-2): 103-9, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17553478

RESUMEN

BACKGROUND: Whole blood choline (WBCHO) and plasma choline (PLCHO) concentrations increase rapidly after stimulation of phospholipase D in acute coronary syndromes (ACS). Early risk-stratification was analyzed in 217 patients with suspected ACS and a negative admission troponin T (<0.03 microg/L). METHODS: WBCHO and PLCHO were measured using high-performance-liquid-chromatography mass spectrometry. Major cardiac events (MACE) were defined as cardiac death/arrest, coronary intervention or myocardial infarction (MI). RESULTS: WBCHO (> or = 28.2 micromol/L) was predictive for MACE (hazard ratio [HR] 2.7; p<0.001), cardiac death/arrest (HR 4.2; p=0.015), heart failure (HR 2.8; p=0.003), coronary intervention (HR 2.1; p=0.01) and MI (HR 8.4; p=0.002) after 30 days. PLCHO (> or = 25.0 micromol/L) was predictive for MACE (HR 2.6; p=0.005), cardiac death/arrest (HR 15.7; p<0.001), heart failure (HR 6.0; p<0.001) but not for coronary intervention and MI. WBCHO and PLCHO were predictive for MACE in multivariate analysis (Odds ratio [OR] 2.7, p=0.009 and OR 3.3, p=0.03) independently of age, gender, prior MI, coronary risk factors and ECG. CONCLUSIONS: WBCHO and PLCHO are significant and independent predictors of major cardiac events in admission troponin T negative acute coronary syndromes. Both are predictive for events related to tissue ischemia and WBCHO is capable of detecting risks associated with coronary plaque instability.


Asunto(s)
Colina/sangre , Enfermedad Coronaria/sangre , Enfermedad Coronaria/diagnóstico , Anciano , Cromatografía Líquida de Alta Presión , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico , Femenino , Humanos , Masculino , Espectrometría de Masas , Persona de Mediana Edad , Isquemia Miocárdica/sangre , Isquemia Miocárdica/diagnóstico , Valor Predictivo de las Pruebas , Pronóstico , Sensibilidad y Especificidad , Troponina T/sangre
9.
Am J Cardiol ; 91(9): 1060-7, 2003 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-12714147

RESUMEN

Troponins I and T represent the current biomarker standard for diagnosis of myocardial infarction. Even small increases of cardiac troponins have prognostic implications, but not all patients at risk are correctly classified, particularly at admission. We identified elevated whole-blood choline as a promising marker and performed a prospective study of 327 patients with a suspected acute coronary syndrome that focused on the analysis of troponin-negative patients. Diagnostic classification of patients and the definition of troponin cutoffs were performed according to the new European Society of Cardiology/American College of Cardiology criteria. Blood was sampled serially and choline was measured using high-performance liquid chromatography mass spectrometry in whole blood. Patients were followed for 30 days. In patients with negative troponin I test results at admission (n = 250), choline was a predictor of cardiac death and nonfatal cardiac arrest (hazard ratio 6.0, p = 0.003), life-threatening arrhythmias (hazard ratio 3.75, p = 0.004), heart failure (hazard ratio 2.87, p = 0.002), and coronary angioplasty (hazard ratio 2.57, p = 0.001). In multivariate analysis of troponin-negative patients, choline was the strongest predictor of cardiac death or arrest (odds ratio 6.05, p = 0.01). Choline was not a marker for myocardial necrosis but indicated high-risk unstable angina in patients without acute myocardial infarction (sensitivity 86.4%, specificity 86.2%). Thus, an increased concentration of choline at hospital admission is a predictor of adverse cardiac events in patients with suspected acute coronary syndromes. Whole blood choline may be useful for early risk stratification of these patients, particularly if troponin results are negative on admission.


Asunto(s)
Angina Inestable/sangre , Colina/sangre , Infarto del Miocardio/sangre , Angina Inestable/complicaciones , Angina Inestable/mortalidad , Angioplastia Coronaria con Balón , Arritmias Cardíacas/etiología , Biomarcadores/sangre , Femenino , Paro Cardíaco/etiología , Insuficiencia Cardíaca/etiología , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/complicaciones , Infarto del Miocardio/mortalidad , Pronóstico , Curva ROC , Análisis de Regresión , Análisis de Supervivencia , Troponina I/sangre , Troponina T/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA