Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
BMC Oral Health ; 24(1): 144, 2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38297268

RESUMEN

BACKGROUND: Retainers are the only effective approach to prevent orthodontic relapse. The aim of this study was to compare the changes in color and light-transmittance of rough and smooth thermoformed polyurethane and copolymer retainer samples after staining in different solutions and destaining with different approaches. METHODS: Four hundred copolyester (Essix® ACE) and 400 polyurethane (Zendura®) samples with different surface textures, smooth and rough, were stained in 4 different solutions (n = 100 per solution) over 28 days. Each of the four groups of 100 stained samples of each material was subdivided into 5 groups of 20 samples and subjected to different destaining solutions. Light transmittance and color changes were evaluated using a spectrometer and a spectrophotometer. Mean differences were compared using a two-way analysis of variance (ANOVA) and posthoc multiple comparison tests at P = 0.05. RESULTS: No significant differences in light transmittance were found between both untreated materials. Both materials were stained in a similar fashion and showed no significant differences between two materials after staining. Coffee and tea stained both materials more significantly than wine, but there was a significant difference of changes of color and light transmittance between rough and smooth surfaces during the destaining in coffee- and tea-stained samples of copolyester material. All destaining solutions were effective at removing all stains on the samples. The surface roughness of the material plays a significant role in the ability of the materials to be destained, demonstrating a more significant greater effect on cleaning rough samples for improvements in light-transmittance and greater changes in color. CONCLUSIONS: This study concluded that the surface of materials plays a significant role in the material destaining and staining. In addition, the different polymers used for retainer fabrication exhibited different responses during the destaining process depending on types of stains.


Asunto(s)
Café , Poliuretanos , Humanos , Espectrofotometría , Coloración y Etiquetado , Colorantes , , Ensayo de Materiales , Color , Propiedades de Superficie , Resinas Compuestas
2.
Materials (Basel) ; 15(19)2022 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-36234148

RESUMEN

This study evaluated the efficacy of different cleaning methods with respect to changes in the color and light transmittance of both rough and smooth thermoformed, copolyester retainer specimens, after staining in different solutions. Four hundred copolyester sheets (Essix ACE) specimens were fabricated over molds with different surface textures, smooth and rough. The specimens were stained in four different solutions (n = 100 per solution) over 28 days; then, each of the four groups of 100 stained specimens was sub-divided into five groups of 20 specimens and subjected to a different destaining solution. The specimens were sub-divided with half subjected to an additional ultrasonic cleaning procedure. Light transmittance and color changes were analyzed using a spectrometer/integrating sphere assembly and a spectrophotometer. Mean difference comparisons were performed using appropriate statistical tests at p = 0.05. All five destaining solutions proved to be effective at removing coffee and tea stains. The surface roughness of the retainer material plays a significant role in the ability of cleaning solutions to remove stains, demonstrating a greater effect on cleaning rough specimens with respect to improvements in light transmittance and greater changes in color. Additionally, an ultrasonic cleaning unit generally enhanced the ability of all five solutions to clean the tea-stained specimens. However, the enhancements were only significant for light transmittance.

3.
J Biomed Mater Res B Appl Biomater ; 108(8): 3323-3330, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32562464

RESUMEN

OBJECTIVES: Zirconia with 3 mol% yttria (3Y-TZP) has been used for dental crowns and bridges due to its excellent mechanical behavior. Performing fracture toughness testing on this nanograin material, however, can be a challenge. For reliable results, fracture toughness testing requires an extremely sharp notch in the test specimen that closely approximates a very sharp crack. This study was to investigate an alternative method to produce nanometer-sized notches, which are less than the average grain size of 3Y-TZP, during the preparation of single-edge V-notched beam specimens and report the resulting fracture toughness value. METHODS: We present a method using focused ion beam (FIB) milling to fabricate nanometer-sized notches in 3Y-TZP. The notch tip is <100 nm wide, which is smaller than the grain size, and is consistent throughout the thickness of the specimen. RESULTS: The FIB-notched specimens show a much reduced average fracture toughness of 5.64 ± 1.14 MPa√m compared to 8.90 ± 0.23 MPa√m for the specimens without FIB-notches. The FIB-milling did not appear to create any monoclinic phase prior to fracture toughness testing. Fractures originated at the FIB-notches, and the notch size can be readily identified post-mortem using a microscope. A considerable amount of tetragonal-to-monoclinic phase transformation was observed throughout the fracture surfaces. SIGNIFICANCE: FIB milling provides an alternative method to fabricate nanometer-sized notches that are smaller than the grain size of tetragonal zirconia polycrystal. The fracture toughness determined using FIB-notches was ~5.64 MPa√m, smaller than the specimens with V-notches fabricated using saw blades.


Asunto(s)
Coronas , Dentadura Parcial Fija , Circonio/química , Materiales Dentales , Pruebas de Dureza , Ensayo de Materiales , Tamaño de la Partícula , Estrés Mecánico , Itrio
4.
Clin Oral Investig ; 23(11): 3995-4010, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30737620

RESUMEN

OBJECTIVES: To investigate the relationship of the irradiance-beam-profile areas from six different light-curing units (LCUs) with the degree of conversion (DC), microhardness (KH), and cross-link density (CLD) throughout a resin-based composite (RBC) cured at two clinically relevant distances, and to explore the correlations among them. MATERIALS AND METHODS: A mapping approach was used to measure DC using micro-Raman spectroscopy, KH using a Knoop indentor on a hardness tester, and %KH reduction after ethanol exposure, as an indicator for CLD within a nano-hybrid RBC increment (n = 3) at various depths. These sample composites were cured from two distances while maintaining the radiant exposure, using six different light-curing units: one quartz-tungsten-halogen; two single and three multiple-emission-peak light-emitting-diode units. Irradiance beam profiles were generated for each LCU at both distances, and localized irradiance values were calculated. Points across each depth were analyzed using repeated measures ANOVA. Correlations across multiple specimen locations and associations between beam uniformity corresponding with polymerization measurements were calculated using linear mixed models and Pearson correlation coefficients. RESULTS: Significant non-uniform polymerization patterns occurred within the specimens at various locations and depths. At 2-mm curing distance, the localized DC = 52.7-76.8%, KH = 39.0-66.7 kg/mm2, and %KH reduction = 26.7-57.9%. At 8-mm curing distance, the localized DC = 50.4-78.6%, KH = 40.3-73.7 kg/mm2, and %KH reduction = 28.2-56.8%. The localized irradiance values were weakly correlated with the corresponding DC, KH, and %KH reduction, with only a few significant correlations (p < 0.05). CONCLUSIONS: Although significant differences were observed at each depth within the specimens, the localized irradiance values for all LCUs did not reflect the polymerization pattern and did not seem to have a major influence on polymerization patterns within the RBC, regardless of the curing distance. CLINICAL RELEVANCE: Commonly used LCUs do not produce uniform polymerization regardless of the curing distance, which may contribute to the risk of RBC fracture.


Asunto(s)
Resinas Compuestas , Luces de Curación Dental , Materiales Dentales , Dureza , Ensayo de Materiales , Polimerizacion , Propiedades de Superficie
5.
Angle Orthod ; 89(3): 432-437, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30605015

RESUMEN

OBJECTIVES: To evaluate long-term light transmittance, surface roughness, and flexural modulus of polypropylene/ethylene copolymer retainer material after exposure to different cleaning methods. MATERIALS AND METHODS: Standardized polypropylene/ethylene copolymer retainer specimens (n = 70, 50.8 mm × 12.7 mm × 1.0 mm) were subjected to seven chemical cleaning solutions: Invisalign cleaning crystals, Retainer Brite, Polident, Listerine mouthwash, 2.5% acetic acid, 0.6% NaClO, and 3% H2O2 for 6 months. The specimens were exposed to the different solutions twice a week for 15 minutes or according to manufacturer's instructions, then stored in artificial saliva at 37°C. Another group of specimens (n = 10) were brushed with a standardized toothbrushing machine for 2 minutes twice a week. At baseline and 6 months, light transmittance, surface roughness, and flexural modulus of the specimens were quantified using spectrophotometry, profilometry and three-point bend testing, respectively. Qualitative analysis was performed using a scanning electron microscope (SEM). Statistical analyses were performed at a significance level of .05. RESULTS: The results showed that light transmittance decreased significantly from baseline for all cleaning methods at 6 months. For an individual method, no significant differences were observed between specimens at baseline and 6 months in surface roughness and flexural modulus. No discernible differences in surface features were observed on SEM images. CONCLUSIONS: The results indicate that different cleaning methods affect the long-term light transmittance of the studied polypropylene/ethylene copolymer retainer material. However, for an individual cleaning method, no significant differences were shown for surface roughness or flexural modulus values at 6-months compared to baseline.


Asunto(s)
Etilenos , Aparatos Ortodóncicos Removibles , Polipropilenos , Peróxido de Hidrógeno , Ensayo de Materiales , Propiedades de Superficie
6.
Angle Orthod ; 89(2): 221-227, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30080124

RESUMEN

OBJECTIVE: To evaluate light transmittance, surface roughness, and flexural modulus of copolyester retainer material after long-term exposure to different cleaning methods. MATERIALS AND METHODS: Standardized copolyester retainer specimens (ACE) were subjected to seven chemical cleaning solutions for 6 months: Invisalign cleaning crystals, Retainer Brite, Polident, Listerine mouthwash, 2.5% acetic acid, 0.6% NaClO, and 3% H2O2. Seventy specimens (n = 10 per method, 50.8 mm × 12.7 mm × 1.0 mm) were exposed to the different solutions twice a week for 2 minutes or according to manufacturer's instructions and stored in artificial saliva at 37°C. Another group of specimens (n = 10) was brushed with a standardized toothbrushing machine for 2 minutes twice a week. At baseline and 6 months, light transmittance, surface roughness and flexural modulus of the specimens were quantified using spectrophotometry, profilometry, and three-point bend testing, respectively. Qualitative assessment was performed using scanning electron microscopy (SEM). Statistical analyses were accomplished at a significance level of .05. RESULTS: The results indicated that light transmittance through the specimens decreased significantly from baseline for all cleaning methods at 6 months. Flexural modulus of the specimens decreased significantly for all cleaning methods except Invisalign crystals and Retainer Brite ( P > .05). The Listerine group demonstrated the worst light transmittance change while H2O2 demonstrated the greatest change in flexural modulus of the specimens compared with other cleaning methods; however, no qualitative difference was observed using SEM analysis. CONCLUSIONS: The results suggest that different cleaning methods affect long-term physical properties of the ACE retainer material. At the present time, none of these cleaning methods is ideal for copolyester retainer material.


Asunto(s)
Peróxido de Hidrógeno , Aparatos Ortodóncicos Removibles , Cepillado Dental , Ensayo de Materiales , Antisépticos Bucales , Docilidad , Propiedades de Superficie
7.
Angle Orthod ; 88(3): 355-362, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29509024

RESUMEN

OBJECTIVES: To evaluate the long-term effects of seven different cleaning methods on light transmittance, surface roughness, and flexural modulus of a polyurethane retainer material. MATERIALS AND METHODS: Polyurethane retainer specimens (Vivera®, Align Technology Inc) (70 specimens, n = 10 per method, 50.8 mm × 12.7 mm × 1.0 mm) were exposed to seven cleaning methods twice a week for 6 months. Before treatment and after 6 months, light transmittance, surface roughness, and flexural modulus of the specimens were quantified. Qualitative assessment of randomly selected specimens from each solution was performed at baseline and after 6 months using a scanning electron microscope. Statistical analyses were performed at the .05 significance level. RESULTS: Of the three test variables, light transmittance through the specimens was the only one that changed significantly from baseline to 6 months for all cleaning solutions, with all of them causing a decrease. However, except for 0.6% sodium hypochlorite showing a change in surface roughness values and 2.5% vinegar and toothbrushing showing an increase in flexural modulus, none of the other four cleaning methods resulted in significant changes in surface roughness or flexural modulus values for the polyurethane specimens between baseline and after 6 months. CONCLUSIONS: Of the seven cleaning methods, Invisalign® cleaning crystals, Polident®, and Listerine® showed the least amount of change in light transmittance values for the polyurethane specimens over 6 months, and they had no effect on surface roughness and flexural modulus values.


Asunto(s)
Detergentes/administración & dosificación , Aparatos Ortodóncicos Removibles , Poliuretanos , Limpiadores de Dentadura , Humanos , Luz , Diseño de Aparato Ortodóncico , Propiedades de Superficie
8.
J Biomed Mater Res B Appl Biomater ; 106(4): 1496-1504, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-28727251

RESUMEN

The aims of this study were to profile light radiated from two light-curing units (LCUs) and evaluate profile relationship to polymerization patterns within a resin-matrix composite (RMC). Beam profiles of one multiple emission peak light-emitting-diode and one quartz-tungsten-halogen curing-unit were measured using a beam profiler/spectrometer system. A camera-based profiler and an integrating sphere/spectrometer assembly were used to evaluate each LCU beam. Polymerization patterns within a nano-hybrid RMC were investigated using a mapping approach by assessing the degree of conversion utilizing micro-Raman spectroscopy and indirectly estimating cross-link-density by repeated microhardness testing before and after exposure to ethanol (%KH reduction, n = 3). The irradiance received on the top and bottom specimen surfaces from both LCUs was measured using a MARC-RC system. The investigated beam profile area from both LCUs was non-uniform and yielded localized discrepancies in DC (55.7-74.9%) and %KH reduction (26.7-54.1%). The LCU irradiance received at the bottom of the specimens was ∼10% of the top value. This study demonstrated that LCU beam profiles were non-uniform in the area explored. Localized differences in DC and %KH reduction existed throughout the RMC specimens but did not follow a specific pattern. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1496-1504, 2018.


Asunto(s)
Resinas Compuestas/química , Luz , Ensayo de Materiales , Polimerizacion , Dureza , Espectroscopía Infrarroja por Transformada de Fourier , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA