Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Chem Lab Med ; 57(8): 1142-1152, 2019 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-31112502

RESUMEN

Background The National Institute of Standards and Technology (NIST) Reference Material RM 8366 was developed to improve the quality of gene copy measurements of EGFR (epidermal growth factor receptor) and MET (proto-oncogene, receptor tyrosine kinase), important targets for cancer diagnostics and treatment. The reference material is composed of genomic DNA prepared from six human cancer cell lines with different levels of amplification of the target genes. Methods The reference values for the ratios of the EGFR and MET gene copy numbers to the copy numbers of reference genes were measured using digital PCR. The digital PCR measurements were confirmed by two additional laboratories. The samples were also characterized using Next Generation Sequencing (NGS) methods including whole genome sequencing (WGS) at three levels of coverage (approximately 1 ×, 5 × and greater than 30 ×), whole exome sequencing (WES), and two different pan-cancer gene panels. The WES data were analyzed using three different bioinformatic algorithms. Results The certified values (digital PCR) for EGFR and MET were in good agreement (within 20%) with the values obtained from the different NGS methods and algorithms for five of the six components; one component had lower NGS values. Conclusions This study shows that NIST RM 8366 is a valuable reference material to evaluate the performance of assays that assess EGFR and MET gene copy number measurements.


Asunto(s)
Secuenciación de Nucleótidos de Alto Rendimiento/normas , Proteínas Proto-Oncogénicas c-met/genética , ADN de Neoplasias/genética , Receptores ErbB/genética , Receptores ErbB/normas , Dosificación de Gen , Humanos , Reacción en Cadena de la Polimerasa , Proto-Oncogenes Mas , Proteínas Proto-Oncogénicas c-met/normas , Estándares de Referencia , Células Tumorales Cultivadas
2.
J Mol Diagn ; 18(5): 753-761, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27455875

RESUMEN

The National Institute of Standards and Technology (NIST) Standard Reference Materials 2373 is a set of genomic DNA samples prepared from five breast cancer cell lines with certified values for the ratio of the HER2 gene copy number to the copy numbers of reference genes determined by real-time quantitative PCR and digital PCR. Targeted-amplicon, whole-exome, and whole-genome sequencing measurements were used with the reference material to compare the performance of both the laboratory steps and the bioinformatic approaches of the different methods using a range of amplification ratios. Although good reproducibility was observed in each next-generation sequencing method, slightly different HER2 copy numbers associated with platform-specific biases were obtained. This study clearly demonstrates the value of Standard Reference Materials 2373 as reference material and as a calibrator for evaluating assay performance as well as for increasing confidence in reporting HER2 amplification for clinical applications.


Asunto(s)
Amplificación de Genes , Secuenciación de Nucleótidos de Alto Rendimiento , Receptor ErbB-2/genética , Estándares de Referencia , Línea Celular Tumoral , Exoma , Femenino , Dosificación de Gen , Genoma Humano , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Secuenciación de Nucleótidos de Alto Rendimiento/normas , Humanos , Masculino , Neoplasias/diagnóstico , Neoplasias/genética , Reacción en Cadena en Tiempo Real de la Polimerasa
3.
Biomol Detect Quantif ; 8: 1-8, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27335805

RESUMEN

NIST standard reference material (SRM) 2373 was developed to improve the measurements of the HER2 gene amplification in DNA samples. SRM 2373 consists of genomic DNA extracted from five breast cancer cell lines with different amounts of amplification of the HER2 gene. The five components are derived from the human cell lines SK-BR-3, MDA-MB-231, MDA-MB-361, MDA-MB-453, and BT-474. The certified values are the ratios of the HER2 gene copy numbers to the copy numbers of selected reference genes DCK, EIF5B, RPS27A, and PMM1. The ratios were measured using quantitative polymerase chain reaction and digital PCR, methods that gave similar ratios. The five components of SRM 2373 have certified HER2 amplification ratios that range from 1.3 to 17.7. The stability and homogeneity of the reference materials were shown by repeated measurements over a period of several years. SRM 2373 is a well characterized genomic DNA reference material that can be used to improve the confidence of the measurements of HER2 gene copy number.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...