1.
IUCrJ ; 5(Pt 5): 531-541, 2018 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-30224956

RESUMEN

Diffraction before destruction using X-ray free-electron lasers (XFELs) has the potential to determine radiation-damage-free structures without the need for crystallization. This article presents the three-dimensional reconstruction of the Melbournevirus from single-particle X-ray diffraction patterns collected at the LINAC Coherent Light Source (LCLS) as well as reconstructions from simulated data exploring the consequences of different kinds of experimental sources of noise. The reconstruction from experimental data suffers from a strong artifact in the center of the particle. This could be reproduced with simulated data by adding experimental background to the diffraction patterns. In those simulations, the relative density of the artifact increases linearly with background strength. This suggests that the artifact originates from the Fourier transform of the relatively flat background, concentrating all power in a central feature of limited extent. We support these findings by significantly reducing the artifact through background removal before the phase-retrieval step. Large amounts of blurring in the diffraction patterns were also found to introduce diffuse artifacts, which could easily be mistaken as biologically relevant features. Other sources of noise such as sample heterogeneity and variation of pulse energy did not significantly degrade the quality of the reconstructions. Larger data volumes, made possible by the recent inauguration of high repetition-rate XFELs, allow for increased signal-to-background ratio and provide a way to minimize these artifacts. The anticipated development of three-dimensional Fourier-volume-assembly algorithms which are background aware is an alternative and complementary solution, which maximizes the use of data.

2.
Acta Crystallogr A Found Adv ; 72(Pt 3): 406-11, 2016 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-27126118

RESUMEN

In experimental research referencing two or more measurements to one another is a powerful tool to reduce the effect of systematic errors between different sets of measurements. The interesting quantity is usually derived from two measurements on the same sample under different conditions. While an elaborate experimental design is essential for improving the estimate, the data analysis should also maximally exploit the covariance between the measurements. In X-ray crystallography the difference between structure-factor amplitudes carries important information to solve experimental phasing problems or to determine time-dependent structural changes in pump-probe experiments. Here a multivariate Bayesian method was used to analyse intensity measurement pairs to determine their underlying structure-factor amplitudes and their differences. The posterior distribution of the model parameter was approximated with a Markov chain Monte Carlo algorithm. The described merging method is shown to be especially advantageous when systematic and random errors result in recording negative intensity measurements.

3.
Struct Dyn ; 2(5): 054702, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26798828

RESUMEN

Whether long-range quantum coherent states could exist in biological systems, and beyond low-temperature regimes where quantum physics is known to be applicable, has been the subject to debate for decades. It was proposed by Fröhlich that vibrational modes within protein molecules can order and condense into a lowest-frequency vibrational mode in a process similar to Bose-Einstein condensation, and thus that macroscopic coherence could potentially be observed in biological systems. Despite the prediction of these so-called Fröhlich condensates almost five decades ago, experimental evidence thereof has been lacking. Here, we present the first experimental observation of Fröhlich condensation in a protein structure. To that end, and to overcome the challenges associated with probing low-frequency molecular vibrations in proteins (which has hampered understanding of their role in proteins' function), we combined terahertz techniques with a highly sensitive X-ray crystallographic method to visualize low-frequency vibrational modes in the protein structure of hen-egg white lysozyme. We found that 0.4 THz electromagnetic radiation induces non-thermal changes in electron density. In particular, we observed a local increase of electron density in a long α-helix motif consistent with a subtle longitudinal compression of the helix. These observed electron density changes occur at a low absorption rate indicating that thermalization of terahertz photons happens on a micro- to milli-second time scale, which is much slower than the expected nanosecond time scale due to damping of delocalized low frequency vibrations. Our analyses show that the micro- to milli-second lifetime of the vibration can only be explained by Fröhlich condensation, a phenomenon predicted almost half a century ago, yet never experimentally confirmed.