Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Med Image Anal ; 97: 103230, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38875741

RESUMEN

Challenges drive the state-of-the-art of automated medical image analysis. The quantity of public training data that they provide can limit the performance of their solutions. Public access to the training methodology for these solutions remains absent. This study implements the Type Three (T3) challenge format, which allows for training solutions on private data and guarantees reusable training methodologies. With T3, challenge organizers train a codebase provided by the participants on sequestered training data. T3 was implemented in the STOIC2021 challenge, with the goal of predicting from a computed tomography (CT) scan whether subjects had a severe COVID-19 infection, defined as intubation or death within one month. STOIC2021 consisted of a Qualification phase, where participants developed challenge solutions using 2000 publicly available CT scans, and a Final phase, where participants submitted their training methodologies with which solutions were trained on CT scans of 9724 subjects. The organizers successfully trained six of the eight Final phase submissions. The submitted codebases for training and running inference were released publicly. The winning solution obtained an area under the receiver operating characteristic curve for discerning between severe and non-severe COVID-19 of 0.815. The Final phase solutions of all finalists improved upon their Qualification phase solutions.

3.
Mar Pollut Bull ; 202: 116303, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38569305

RESUMEN

Sargassum spp. strandings in the tropical Atlantic harm local ecosystems due to toxic sulfide levels. We conducted a mesocosm experiment to test the efficacy of iron(III) (hydr)oxides in (a) mitigating sulfide toxicity in mangroves resulting from Sargassum and (b) reducing potentially enhanced greenhouse gas emissions. Our results show that iron addition failed to prevent mangrove mortality caused by highly toxic sulfide concentrations, which reached up to 15,000 µmol l-1 in 14 days; timely removal may potentially prevent mangrove death. Sargassum-impacted mesocosms significantly increased methane, nitrous oxide, and carbon dioxide emissions, producing approximately 1 g CO2-equivalents m-2 h-1 during daylight hours, thereby shifting mangroves from sinks to sources of greenhouse gasses. However, iron addition decreased methane emissions by 62 % and nitrous oxide emissions by 57 %. This research reveals that Sargassum strandings have multiple adverse effects related to chemical and ecological dynamics in mangrove ecosystems, including greenhouse gas emissions.


Asunto(s)
Metano , Óxido Nitroso , Sargassum , Sulfuros , Humedales , Hierro , Contaminantes Químicos del Agua/toxicidad , Gases de Efecto Invernadero/análisis
4.
Radiol Cardiothorac Imaging ; 6(2): e230172, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38573128

RESUMEN

Purpose To perform a qualitative and quantitative evaluation of the novel image-navigated (iNAV) 3D late gadolinium enhancement (LGE) cardiac MRI imaging strategy in comparison with the conventional diaphragm-navigated (dNAV) 3D LGE cardiac MRI strategy for the assessment of left atrial fibrosis in atrial fibrillation (AF). Materials and Methods In this prospective study conducted between April and September 2022, 26 consecutive participants with AF (mean age, 61 ± 11 years; 19 male) underwent both iNAV and dNAV 3D LGE cardiac MRI, with equivalent spatial resolution and timing in the cardiac cycle. Participants were randomized in the acquisition order of iNAV and dNAV. Both, iNAV-LGE and dNAV-LGE images were analyzed qualitatively using a 5-point Likert scale and quantitatively (percentage of atrial fibrosis using image intensity ratio threshold 1.2), including testing for overlap in atrial fibrosis areas by calculating Dice score. Results Acquisition time of iNAV was significantly lower compared with dNAV (4.9 ± 1.1 minutes versus 12 ± 4 minutes, P < .001, respectively). There was no evidence of a difference in image quality for all prespecified criteria between iNAV and dNAV, although dNAV was the preferred image strategy in two-thirds of cases (17/26, 65%). Quantitative assessment demonstrated that mean fibrosis scores were lower for iNAV compared with dNAV (12 ± 8% versus 20 ± 12%, P < .001). Spatial correspondence between the atrial fibrosis maps was modest (Dice similarity coefficient, 0.43 ± 0.15). Conclusion iNAV-LGE acquisition in individuals with AF was more than twice as fast as dNAV acquisition but resulted in a lower atrial fibrosis score. The differences between these two strategies might impact clinical interpretation. ©RSNA, 2024.


Asunto(s)
Fibrilación Atrial , Diafragma , Anciano , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial/diagnóstico , Medios de Contraste , Gadolinio , Atrios Cardíacos/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Prospectivos , Femenino
5.
Eur J Radiol ; 174: 111386, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38447431

RESUMEN

PURPOSE: Studies have shown the incremental value of strain imaging in various cardiac diseases. However, reproducibility and generalizability has remained an issue of concern. To overcome this, simplified algorithms such as rapid atrioventricular strains have been proposed. This multicenter study aimed to assess the reproducibility of rapid strains in a real-world setting and identify potential predictors for higher interobserver variation. METHODS: A total of 4 sites retrospectively identified 80 patients and 80 healthy controls who had undergone cardiac magnetic resonance imaging (CMR) at their respective centers using locally available scanners with respective field strengths and imaging protocols. Strain and volumetric parameters were measured at each site and then independently re-evaluated by a blinded core lab. Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to assess inter-observer agreement. In addition, backward multiple linear regression analysis was performed to identify predictors for higher inter-observer variation. RESULTS: There was excellent agreement between sites in feature-tracking and rapid strain values (ICC ≥ 0.96). Bland-Altman plots showed no significant bias. Bi-atrial feature-tracking and rapid strains showed equally excellent agreement (ICC ≥ 0.96) but broader limits of agreement (≤18.0 % vs. ≤3.5 %). Regression analysis showed that higher field strength and lower temporal resolution (>30 ms) independently predicted reduced interobserver agreement for bi-atrial strain parameters (ß = 0.38, p = 0.02 for field strength and ß = 0.34, p = 0.02 for temporal resolution). CONCLUSION: Simplified rapid left ventricular and bi-atrial strain parameters can be reliably applied in a real-world multicenter setting. Due to the results of the regression analysis, a minimum temporal resolution of 30 ms is recommended when assessing atrial deformation.


Asunto(s)
Imagen por Resonancia Cinemagnética , Imagen por Resonancia Magnética , Humanos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Imagen por Resonancia Cinemagnética/métodos , Atrios Cardíacos , Variaciones Dependientes del Observador , Función Ventricular Izquierda
7.
Med Phys ; 51(4): 2834-2845, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38329315

RESUMEN

BACKGROUND: Automated estimation of Pulmonary function test (PFT) results from Computed Tomography (CT) could advance the use of CT in screening, diagnosis, and staging of restrictive pulmonary diseases. Estimating lung function per lobe, which cannot be done with PFTs, would be helpful for risk assessment for pulmonary resection surgery and bronchoscopic lung volume reduction. PURPOSE: To automatically estimate PFT results from CT and furthermore disentangle the individual contribution of pulmonary lobes to a patient's lung function. METHODS: We propose I3Dr, a deep learning architecture for estimating global measures from an image that can also estimate the contributions of individual parts of the image to this global measure. We apply it to estimate the separate contributions of each pulmonary lobe to a patient's total lung function from CT, while requiring only CT scans and patient level lung function measurements for training. I3Dr consists of a lobe-level and a patient-level model. The lobe-level model extracts all anatomical pulmonary lobes from a CT scan and processes them in parallel to produce lobe level lung function estimates that sum up to a patient level estimate. The patient-level model directly estimates patient level lung function from a CT scan and is used to re-scale the output of the lobe-level model to increase performance. After demonstrating the viability of the proposed approach, the I3Dr model is trained and evaluated for PFT result estimation using a large data set of 8 433 CT volumes for training, 1 775 CT volumes for validation, and 1 873 CT volumes for testing. RESULTS: First, we demonstrate the viability of our approach by showing that a model trained with a collection of digit images to estimate their sum implicitly learns to assign correct values to individual digits. Next, we show that our models can estimate lobe-level quantities, such as COVID-19 severity scores, pulmonary volume (PV), and functional pulmonary volume (FPV) from CT while only provided with patient-level quantities during training. Lastly, we train and evaluate models for producing spirometry and diffusion capacity of carbon mono-oxide (DLCO) estimates at the patient and lobe level. For producing Forced Expiratory Volume in one second (FEV1), Forced Vital Capacity (FVC), and DLCO estimates, I3Dr obtains mean absolute errors (MAE) of 0.377 L, 0.297 L, and 2.800 mL/min/mm Hg respectively. We release the resulting algorithms for lung function estimation to the research community at https://grand-challenge.org/algorithms/lobe-wise-lung-function-estimation/ CONCLUSIONS: I3Dr can estimate global measures from an image, as well as the contributions of individual parts of the image to this global measure. It offers a promising approach for estimating PFT results from CT scans and disentangling the individual contribution of pulmonary lobes to a patient's lung function. The findings presented in this work may advance the use of CT in screening, diagnosis, and staging of restrictive pulmonary diseases as well as in risk assessment for pulmonary resection surgery and bronchoscopic lung volume reduction.


Asunto(s)
Enfermedades Pulmonares , Pulmón , Humanos , Pulmón/diagnóstico por imagen , Pulmón/cirugía , Tomografía Computarizada por Rayos X/métodos , Capacidad Vital , Aprendizaje Automático
8.
Pacing Clin Electrophysiol ; 47(1): 121-123, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38055567

RESUMEN

Cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients with left ventricular dysfunction and a left bundle branch block. However, its impact on right ventricular (RV) function remains uncertain. This cardiac magnetic resonance imaging study found that CRT did not improve RV volumes and function, and CRT-off during follow-up had an immediate detrimental effect on the RV, which may suggest potential unfavorable RV remodeling with RV pacing during CRT.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Bloqueo de Rama/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Resultado del Tratamiento , Insuficiencia Cardíaca/terapia , Función Ventricular Izquierda , Electrocardiografía/métodos
9.
Eur Heart J Cardiovasc Imaging ; 25(3): 347-355, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-37812691

RESUMEN

AIMS: We examined the association between the symptom-to-reperfusion-time and cardiovascular magnetic resonance (CMR)-derived global strain parameters and transmural infarct extent in ST-segment elevation myocardial infarction (STEMI) patients. METHODS AND RESULTS: The study included 108 STEMI patients who underwent successful primary percutaneous coronary intervention (PPCI). Patients were categorized according to the median symptom-to-reperfusion-time: shorter (<160 min, n = 54) and longer times (>160 min, n = 54). CMR was performed 2-7 days after PPCI and at 1 month. CMR cine imaging was performed for functional assessment and late gadolinium enhancement to evaluate transmural infarct extent. Myocardial feature-tracking was used for strain analysis. Groups were comparable in relation to incidence of LAD disease and pre- and post-PPCI thrombolysis in myocardial infarction (TIMI) flow grades. The mean transmural extent score at follow-up was lower in patients with shorter reperfusion time (P < 0.01). Both baseline and follow-up maximum transmural extent scores were smaller in patients with shorter reperfusion time (P = 0.03 for both). Patients with shorter reperfusion time had more favourable global left ventricular (LV) circumferential strain (baseline, P = 0.049; follow-up, P = 0.01) and radial strain (baseline, P = 0.047; follow-up, P < 0.01), whilst LV longitudinal strain appeared comparable for both baseline and follow-up (P > 0.05 for both). In multi-variable regression analysis including all three strain directions, baseline LV circumferential strain was independently associated with the mean transmural extent score at follow-up (ß=1.89, P < 0.001). CONCLUSION: In STEMI patients, time-to-reperfusion was significantly associated with smaller transmural extent of infarction and better LV circumferential and radial strain. Moreover, infarct transmurality and residual LV circumferential strain are closely linked.


Asunto(s)
Infarto del Miocardio con Elevación del ST , Humanos , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/terapia , Infarto del Miocardio con Elevación del ST/complicaciones , Medios de Contraste , Gadolinio , Corazón , Reperfusión
10.
Interface Focus ; 13(6): 20230038, 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-38106921

RESUMEN

To enable large in silico trials and personalized model predictions on clinical timescales, it is imperative that models can be constructed quickly and reproducibly. First, we aimed to overcome the challenges of constructing cardiac models at scale through developing a robust, open-source pipeline for bilayer and volumetric atrial models. Second, we aimed to investigate the effects of fibres, fibrosis and model representation on fibrillatory dynamics. To construct bilayer and volumetric models, we extended our previously developed coordinate system to incorporate transmurality, atrial regions and fibres (rule-based or data driven diffusion tensor magnetic resonance imaging (MRI)). We created a cohort of 1000 biatrial bilayer and volumetric models derived from computed tomography (CT) data, as well as models from MRI, and electroanatomical mapping. Fibrillatory dynamics diverged between bilayer and volumetric simulations across the CT cohort (correlation coefficient for phase singularity maps: left atrial (LA) 0.27 ± 0.19, right atrial (RA) 0.41 ± 0.14). Adding fibrotic remodelling stabilized re-entries and reduced the impact of model type (LA: 0.52 ± 0.20, RA: 0.36 ± 0.18). The choice of fibre field has a small effect on paced activation data (less than 12 ms), but a larger effect on fibrillatory dynamics. Overall, we developed an open-source user-friendly pipeline for generating atrial models from imaging or electroanatomical mapping data enabling in silico clinical trials at scale (https://github.com/pcmlab/atrialmtk).

11.
BMC Cardiovasc Disord ; 23(1): 621, 2023 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-38114911

RESUMEN

BACKGROUND: Conduction system pacing (CSP) is a novel technique that involves pacing the His-Purkinje system instead of the traditional right ventricular (RV) apex. This technique aims to avoid the adverse effects of RV apical pacing, which can lead to ventricular dyssynchrony and heart failure over time. CSP is gaining popularity but its long-term efficacy and challenges remain uncertain. This report discusses a case where CSP was initially successful but faced complications due to an increasing pacing threshold. CASE PRESENTATION: A 65-year-old female with total atrioventricular block was referred for brady-pacing. Due to the potential for chronic RV pacing, CSP was chosen. The CSP implantation involved subcutaneous device placement, with a CSP lead in the left bundle branch area (LBBA) and an RV backup lead. A year after successful implantation, the LBBA pacing threshold progressively increased. Subsequent efforts to correct it led to anodal capture and battery depletion. Cardiac magnetic resonance imaging (CMR) revealed mid-septal fibrosis at the area of LBBA lead placement and suggested cardiac sarcoidosis as a possible cause. CONCLUSION: CSP is a promising technique for treating bradyarrhythmias, but this case underscores the need for vigilance in monitoring pacing thresholds. Increasing thresholds can render CSP ineffective, necessitating alternative pacing methods. The CMR findings of mid-septal fibrosis and the potential diagnosis of cardiac sarcoidosis emphasize the importance of pre-implantation assessment, as CSP may be compromised by underlying structural abnormalities. This report highlights the complexities of pacing strategy selection and the significance of comprehensive evaluation before adopting CSP.


Asunto(s)
Marcapaso Artificial , Sarcoidosis , Femenino , Humanos , Anciano , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Sistema de Conducción Cardíaco , Trastorno del Sistema de Conducción Cardíaco , Fibrosis , Electrocardiografía , Fascículo Atrioventricular , Resultado del Tratamiento
14.
Radiother Oncol ; 189: 109949, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37827279

RESUMEN

BACKGROUND AND PURPOSE: In patients with recurrent ventricular tachycardia (VT), STereotactic Arrhythmia Radioablation (STAR) shows promising results. The STOPSTORM.eu consortium was established to investigate and harmonise STAR treatment in Europe. The primary goals of this benchmark study were to standardise contouring of organs at risk (OAR) for STAR, including detailed substructures of the heart, and accredit each participating centre. MATERIALS AND METHODS: Centres within the STOPSTORM.eu consortium were asked to delineate 31 OAR in three STAR cases. Delineation was reviewed by the consortium expert panel and after a dedicated workshop feedback and accreditation was provided to all participants. Further quantitative analysis was performed by calculating DICE similarity coefficients (DSC), median distance to agreement (MDA), and 95th percentile distance to agreement (HD95). RESULTS: Twenty centres participated in this study. Based on DSC, MDA and HD95, the delineations of well-known OAR in radiotherapy were similar, such as lungs (median DSC = 0.96, median MDA = 0.1 mm and median HD95 = 1.1 mm) and aorta (median DSC = 0.90, median MDA = 0.1 mm and median HD95 = 1.5 mm). Some centres did not include the gastro-oesophageal junction, leading to differences in stomach and oesophagus delineations. For cardiac substructures, such as chambers (median DSC = 0.83, median MDA = 0.2 mm and median HD95 = 0.5 mm), valves (median DSC = 0.16, median MDA = 4.6 mm and median HD95 = 16.0 mm), coronary arteries (median DSC = 0.4, median MDA = 0.7 mm and median HD95 = 8.3 mm) and the sinoatrial and atrioventricular nodes (median DSC = 0.29, median MDA = 4.4 mm and median HD95 = 11.4 mm), deviations between centres occurred more frequently. After the dedicated workshop all centres were accredited and contouring consensus guidelines for STAR were established. CONCLUSION: This STOPSTORM multi-centre critical structure contouring benchmark study showed high agreement for standard radiotherapy OAR. However, for cardiac substructures larger disagreement in contouring occurred, which may have significant impact on STAR treatment planning and dosimetry evaluation. To standardize OAR contouring, consensus guidelines for critical structure contouring in STAR were established.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Taquicardia Ventricular , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Benchmarking , Corazón , Vasos Coronarios , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirugía
15.
JACC Clin Electrophysiol ; 9(12): 2665-2679, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37737780

RESUMEN

Cardiac magnetic resonance (CMR) imaging is a valuable noninvasive tool for evaluating tissue response following catheter ablation of atrial tissue. This review provides an overview of the contemporary CMR strategies to visualize atrial ablation lesions in both the acute and chronic postablation stages, focusing on their strengths and limitations. Moreover, the accuracy of CMR imaging in comparison to atrial lesion histology is discussed. T2-weighted CMR imaging is sensitive to edema and tends to overestimate lesion size in the acute stage after ablation. Noncontrast agent-enhanced T1-weighted CMR imaging has the potential to provide more accurate assessment of lesions in the acute stage but may not be as effective in the chronic stage. Late gadolinium enhancement imaging can be used to detect chronic atrial scarring, which may inform repeat ablation strategies. Moreover, novel imaging strategies are being developed, but their efficacy in characterizing atrial lesions is yet to be determined. Overall, CMR imaging has the potential to provide virtual histology that aids in evaluating the efficacy and safety of catheter ablation and monitoring of postprocedural myocardial changes. However, technical factors, scanning during arrhythmia, and transmurality assessment pose challenges. Therefore, further research is needed to develop CMR strategies to visualize the ablation lesion maturation process more effectively.


Asunto(s)
Ablación por Catéter , Medios de Contraste , Humanos , Gadolinio , Imagen por Resonancia Magnética/métodos , Ablación por Catéter/efectos adversos , Espectroscopía de Resonancia Magnética
16.
Eur J Nucl Med Mol Imaging ; 50(13): 3897-3909, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37561140

RESUMEN

PURPOSE: We sought to assess the impact of coronary revascularization on myocardial perfusion and fractional flow reserve (FFR) in patients without a cardiac history, with prior myocardial infarction (MI) or non-MI percutaneous coronary intervention (PCI). Furthermore, we studied the impact of scar tissue. METHODS: Symptomatic patients underwent [15O]H2O positron emission tomography (PET) and FFR before and after revascularization. Patients with prior CAD, defined as prior MI or PCI, underwent scar quantification by magnetic resonance imaging late gadolinium enhancement. RESULTS: Among 137 patients (87% male, age 62.2 ± 9.5 years) 84 (61%) had a prior MI or PCI. The increase in FFR and hyperemic myocardial blood flow (hMBF) was less in patients with prior MI or non-MI PCI compared to those without a cardiac history (FFR: 0.23 ± 0.14 vs. 0.20 ± 0.12 vs. 0.31 ± 0.18, p = 0.02; hMBF: 0.54 ± 0.75 vs. 0.62 ± 0.97 vs. 0.91 ± 0.96 ml/min/g, p = 0.04). Post-revascularization FFR and hMBF were similar across patients without a cardiac history or with prior MI or non-MI PCI. An increase in FFR was strongly associated to hMBF increase in patients without a cardiac history or with prior MI/non-MI PCI (r = 0.60 and r = 0.60, p < 0.01 for both). Similar results were found for coronary flow reserve. In patients with prior MI scar was negatively correlated to hMBF increase and independently predictive of an attenuated CFR increase. CONCLUSIONS: Post revascularization FFR and perfusion were similar among patients without a cardiac history, with prior MI or non-MI PCI. In patients with prior MI scar burden was associated to an attenuated perfusion increase.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Reserva del Flujo Fraccional Miocárdico/fisiología , Angiografía Coronaria/métodos , Cicatriz/diagnóstico por imagen , Medios de Contraste , Resultado del Tratamiento , Gadolinio , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/terapia
17.
J Am Heart Assoc ; 12(15): e028014, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37489727

RESUMEN

Background Among patients with an implantable cardioverter-defibrillator, a high prevalence of atrial fibrillation (AF) is present. Identification of AF predictors in this patient group is of clinical importance to initiate appropriate preventive therapeutic measures to reduce the risk of AF-related complications. This study assesses whether cardiac magnetic resonance imaging-derived atrial characteristics are associated with AF development in patients with a dual-chamber implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator, as detected by the cardiac implantable electronic device. Methods and Results This single-center retrospective study included 233 patients without documented AF history at the moment of device implantation (dual-chamber implantable cardioverter-defibrillator [63.5%] or cardiac resynchronization therapy defibrillator [36.5%]). All patients underwent cardiac magnetic resonance imaging before device implantation. Cardiac magnetic resonance-derived features of left atrial (LA) remodeling were evaluated in all patients. Detection of AF episodes was based on cardiac implantable electronic device interrogation. During a median follow-up of 6.1 years, a newly diagnosed AF episode was detected in 88 of the 233 (37.8%) patients with an ICD. In these patients, increased LA volumes and impaired LA function (LA emptying fraction and LA strain) were found as compared with patients without AF during follow-up. However, a significant association was only found in patients with dilated cardiomyopathy and not in patients with ischemic cardiomyopathy. Conclusions LA remodeling characteristics were associated with development of AF in patients with dilated cardiomyopathy but not patients with ischemic cardiomyopathy, suggesting different mechanisms of AF development in ischemic cardiomyopathy and dilated cardiomyopathy. Assessment of LA remodeling before device implantation might identify high-risk patients for AF.


Asunto(s)
Fibrilación Atrial , Cardiomiopatía Dilatada , Desfibriladores Implantables , Isquemia Miocárdica , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Desfibriladores Implantables/efectos adversos , Estudios Retrospectivos , Cardiomiopatía Dilatada/etiología , Isquemia Miocárdica/etiología , Imagen por Resonancia Magnética
18.
Int J Cardiovasc Imaging ; 39(9): 1753-1763, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37515682

RESUMEN

PURPOSE: Left atrial (LA) sphericity is a novel, geometry-based parameter that has been used to visualize and quantify LA geometrical remodeling in patients with atrial fibrillation (AF). This study examined the association between LA sphericity, and LA longitudinal strain and strain rate measured by feature-tracking in AF patients. METHODS: 128 AF patients who underwent cardiovascular magnetic resonance (CMR) imaging in sinus rhythm prior to their pulmonary vein isolation (PVI) procedure were retrospectively analyzed. LA sphericity was calculated by segmenting the LA (excluding the pulmonary veins and the LA appendage) on a 3D contrast enhanced MR angiogram and comparing the resulting shape with a perfect sphere. LA global reservoir strain, conduit strain, contractile strain and corresponding strain rates were derived from cine images using feature-tracking. For statistical analysis, Pearson correlations, multivariable logistic regression analysis, and Student t-tests were used. RESULTS: Patients with a spherical LA (dichotomized by the median value) had a lower reservoir strain and conduit strain compared to patients with a non-spherical LA (-15.4 ± 4.2% vs. -17.1 ± 3.5%, P = 0.02 and - 8.2 ± 3.0% vs. -9.5 ± 2.6%, P = 0.01, respectively). LA strain rate during early ventricular diastole was also different between both groups (-0.7 ± 0.3s- 1 vs. -0.9 ± 0.3s- 1, P = 0.001). In contrast, no difference was found for LA contractile strain (-7.2 ± 2.6% vs. -7.6 ± 2.2%, P = 0.30). CONCLUSIONS: LA passive strain is significantly impaired in AF patients with a spherical LA, though this relation was not independent from LA volume.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Valor Predictivo de las Pruebas , Atrios Cardíacos , Ablación por Catéter/métodos
19.
J Clin Med ; 12(12)2023 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-37373691

RESUMEN

OBJECTIVES: This prospective pilot study assessed the feasibility of cardiovascular magnetic resonance (CMR) imaging during biventricular (BIV) pacing in patients with a CMR conditional cardiac resynchronization therapy defibrillator (CRT-D) and compared the results with invasive volume measurements. METHODS: Ten CRT-D patients underwent CMR imaging prior to device implantation (baseline) and six weeks after device implantation, including CRT-on and CRT-off modes. Left ventricular (LV) function, volumes, and strain measurements of LV dyssynchrony and dyscoordination were assessed. Invasive pressure-volume measurements were performed, matching the CRT settings used during CMR. RESULTS: Post-implantation imaging enabled reliable cine assessment, but showed artefacts on late gadolinium enhancement images. After six weeks of CRT, significant reverse remodeling was observed, with a 22.7 ± 11% reduction in LV end-systolic volume during intrinsic rhythm (CRT-off). During CRT-on, the LV ejection fraction significantly improved from 27.4 ± 5.9% to 32.2 ± 8.7% (p < 0.01), and the strain assessment showed the abolition of the left bundle branch block contraction pattern. Invasively measured and CMR-assessed LV hemodynamics during BIV pacing were significantly associated. CONCLUSIONS: Post-CRT implantation CMR assessing acute LV pump function is feasible and provides important insights into the effects of BIV pacing on cardiac function and contraction patterns. LV assessment during CMR may constitute a future CRT optimization strategy.

20.
Front Cardiovasc Med ; 10: 1166703, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37252116

RESUMEN

Background: Patients with mitral regurgitation (MR) commonly suffer from left atrial (LA) remodeling. LA fibrosis is considered to be a key player in the LA remodeling process, as observed in atrial fibrillation (AF) patients. Literature on the presence and extent of LA fibrosis in MR patients however, is scarce and its clinical implications remain unknown. Therefore, the ALIVE trial was designed to investigate the presence of LA remodeling including LA fibrosis in MR patients prior to and after mitral valve repair (MVR) surgery. Methods: The ALIVE trial is a single center, prospective pilot study investigating LA fibrosis in patients suffering from MR in the absence of AF (identifier NCT05345730). In total, 20 participants will undergo a CMR scan including 3D late gadolinium enhancement (LGE) imaging 2 week prior to MVR surgery and at 3 months follow-up. The primary objective of the ALIVE trial is to assess the extent and geometric distribution of LA fibrosis in MR patients and to determine effects of MVR surgery on reversed atrial remodelling. Implications: This study will provide novel insights into the pathophysiological mechanism of fibrotic and volumetric atrial (reversed) remodeling in MR patients undergoing MVR surgery. Our results may contribute to improved clinical decision making and patient-specific treatment strategies in patients suffering from MR.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...