1.
Phys Med Biol ; 52(9): 2545-52, 2007 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-17440251

RESUMEN

A HDTV camera having a direct-sensing x-ray high-gain avalanche rushing amorphous photoconductor (HARP) tube was used, for the first time, to acquire x-ray phase maps. The tube can achieve a high sensitivity as a result of the avalanche multiplication process in the HARP target. A beryllium plate, rather than a glass plate, was used as the face plate of the tube to minimize the loss of x-rays due to absorption, and a 15 microm thick HARP target was directly formed on it. In the experiment, the x-ray phase shifts produced by a rat liver were measured using synchrotron x-rays (lambda = 0.0766 nm) and a triple Laue-case (LLL) x-ray interferometer. Interference patterns produced by the sample were observed with the direct-sensing x-ray HARP tube camera. A voltage of 1300 V was applied to the HARP target to give an output signal gain of two. The camera was operated in 1125 scanning-line mode, and real-time images were stored on a workstation at a rate of 30 images/s with an image format of 960 (H) x 1100 (V) pixels. A phase-map image of the sample was successfully obtained using the fringe scanning method and phase unwrapping. The observed phase shifts ranged from 50 degrees to 200 degrees . Trees of blood vessels in the rat liver were clearly depicted without using a contrast agent. The spatial resolution of the x-ray camera was estimated to be better than 35 microm in the vertical direction and 100 microm in the horizontal direction.


Asunto(s)
Hígado/diagnóstico por imagen , Intensificación de Imagen Radiográfica , Animales , Hígado/irrigación sanguínea , Radiografía/instrumentación , Ratas , Sincrotrones
2.
J Endod ; 23(1): 15-8, 1997 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-9594739

RESUMEN

The aim of this study was to test and compare the values of torsional moment, torsional angular deflection, bending moment, and permanent angular deflection of three designs of root canal files (Unifile, Flexofile, and H-File) before and after cross-infection treatment procedures, according to ANSI/ADA specification no. 28. An increase in value for all mechanical properties tested was observed after the treatment procedures, with the exception of Flexofile wherein a decrease in permanent angular deflection was evident. Unifile showed a decrease in torsional moment and bending moment. The changes in mechanical properties after treatment procedures ranged from 0.1 to 63% from the control groups. Generally, the changes in values observed were insignificant and still well within ANSI/ADA specification no. 28. Thus, they do not have any clinical significance.


Asunto(s)
Instrumentos Dentales , Control de Infección Dental/métodos , Preparación del Conducto Radicular/instrumentación , Esterilización/métodos , Instrumentos Dentales/normas , Contaminación de Equipos/prevención & control , Diseño de Equipo , Estudios de Evaluación como Asunto , Ensayo de Materiales , Docilidad , Acero Inoxidable/química , Torque
3.
J Endod ; 22(12): 651-6, 1996 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9220749

RESUMEN

The cutting efficiency of endodontic instruments was measured using an original experimental technique that incorporates new concepts to simulate clinical conditions. Five designs of #ISO 030 endodontic instruments, K-reamer (Maillefer), Flexofile (Maillefer), Helifile (Micro-mega), K-flex (Kerr), and Unifile (De Trey), were chosen and their cutting efficiency assessed at their full working length of 16 mm on two Plexiglas parallelepipeds tilted to follow the 2% conicity of the instruments. For each instrument, four series of 25 cuts were carried out and each cut made on a new flat, smooth Plexiglas surface with an even hardness of 33 VHN. Instruments were tested under a simulated clinical condition of a quarter clockwise turn ROTARY MOTION followed by a PULL ACTION at 16 mm/s rate, with a fixed load on the instrument of 325 g. Water irrigation at a rate of 85 ml/s was supplied before each procedure. Cutting efficiency was evaluated in terms of mass of Plexiglas cut (using a Mettler analytic balance with accuracy of 3 x 10(-5) g) per unit of energy used by the instrument, i.e. mg/J. Unifile was found to have the best cutting efficiency of 0.80 +/- 0.01 (Mean +/- SD) and lowest cutting efficiency loss followed by Flexofile 0.70 +/- 0.03 then Helifile 0.36 +/- 0.01 then K-flex 0.51 +/- 0.07. K-reamer was found to have the lowest cutting efficiency of 0.16 +/- 0.05.


Asunto(s)
Instrumentos Dentales/normas , Preparación del Conducto Radicular/instrumentación , Eficiencia , Estudios de Evaluación como Asunto , Ensayo de Materiales , Metilmetacrilato , Metilmetacrilatos , Modelos Estructurales , Reproducibilidad de los Resultados
4.
J Endod ; 22(12): 657-61, 1996 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9220750

RESUMEN

The effects of various cleaning, chemical disinfection, and sterilization procedures on the cutting efficiency of endodontic instruments Unifile (De Trey, Bois Colombes, France), (Flexofile Maillefer, Ballaigues, Switzerland), and H-File (Maillefer)) were investigated. The cross-infection control treatment procedures investigated were as follows: chemical disinfection--NaOCl (2.5%) for 12 and 48 h, and NH4 (5%) for 1 and 4 h; ultrasonic cleaning for 4 and 16 cycles of 15 min; and sterilization methods with chemiclave for 5 and 10 cycles of 20 min, Poupinel for 5 and 10 cycles of 120 min at 180 degrees C and glass beads for 10 and 40 cycles of 40 at 250 degrees C. Cutting efficiency was evaluated as the mass of Plexiglas cut per unit of energy expended by the instrument in microgram/Joule. The cutting efficiency decreased from 1 to 77%, depending on the file design and type of treatment procedures. Heat sterilization (Poupinel) did not modify the cutting efficiency of Unifile and Flexofile. The decrease in cutting efficiency was independent of frequency and duration of treatment procedures.


Asunto(s)
Instrumentos Dentales , Control de Infección Dental , Preparación del Conducto Radicular/instrumentación , Amoníaco , Eficiencia , Ensayo de Materiales , Metilmetacrilato , Metilmetacrilatos , Modelos Estructurales , Hipoclorito de Sodio , Esterilización , Ultrasonido