Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Res Sq ; 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38645075

RESUMEN

Chronic interstitial lung diseases (ILDs) require frequent point-of-care monitoring. X-ray-based methods lack resolution and are ionizing. Chest computerized tomographic (CT) scans are expensive and provide more radiation. Conventional ultrasound can detect severe lung damage via vertical artifacts (B-lines). However, this information is not quantitative, and the appearance of B-lines is operator- and system-dependent. Here we demonstrate novel ultrasound-based biomarkers to assess severity of ILDs. Lung alveoli scatter ultrasound waves, leading to a complex acoustic signature, which is affected by changes in alveolar density due to ILDs. We exploit ultrasound scattering in the lung and combine Quantitative Ultrasound (QUS) parameters, to develop ultrasound-based biomarkers that significantly correlate to the severity of pulmonary fibrosis and edema in rodent lungs. These innovative QUS biomarkers will be very significant for monitoring severity of chronic ILDs and response to treatment, especially in this new era of miniaturized and highly portable ultrasound devices.

2.
Front Endocrinol (Lausanne) ; 15: 1326188, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38370358

RESUMEN

Objective: Gray-scale ultrasound (US) is the standard-of-care for evaluating thyroid nodules (TNs). However, the performance is better for the identification of hypoechoic malignant TNs (such as classic papillary thyroid cancer) than isoechoic malignant TNs. Quantitative ultrasound (QUS) utilizes information from raw ultrasonic radiofrequency (RF) echo signal to assess properties of tissue microarchitecture. The purpose of this study is to determine if QUS can improve the cancer risk stratification of isoechoic TNs. Methods: Patients scheduled for TN fine needle biopsy (FNB) were recruited from the Thyroid Health Clinic at Boston Medical Center. B-mode US and RF data (to generate QUS parameters) were collected in 274 TNs (163 isoechoic, 111 hypoechoic). A linear combination of QUS parameters (CQP) was trained and tested for isoechoic [CQP(i)] and hypoechoic [CQP(h)] TNs separately and compared with the performance of conventional B-mode US risk stratification systems. Results: CQP(i) produced an ROC AUC value of 0.937+/- 0.043 compared to a value of 0.717 +/- 0.145 (p >0.05) for the American College of Radiology Thyroid Imaging, Reporting and Data System (ACR TI-RADS) and 0.589 +/- 0.173 (p >0.05) for the American Thyroid Association (ATA) risk stratification system. In this study, CQP(i) avoids unnecessary FNBs in 73% of TNs compared to 55.8% and 11.8% when using ACR TI-RADS and ATA classification system. Conclusion: This data supports that a unique QUS-based classifier may be superior to conventional US stratification systems to evaluate isoechoic TNs for cancer and should be explored further in larger studies.


Asunto(s)
Neoplasias de la Tiroides , Nódulo Tiroideo , Humanos , Estados Unidos , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Estudios Retrospectivos , Biopsia con Aguja Fina , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/patología , Medición de Riesgo
3.
IEEE J Biomed Health Inform ; 27(6): 2932-2943, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37023157

RESUMEN

Automatically identifying the structural substrates underlying cardiac abnormalities can potentially provide real-time guidance for interventional procedures. With the knowledge of cardiac tissue substrates, the treatment of complex arrhythmias such as atrial fibrillation and ventricular tachycardia can be further optimized by detecting arrhythmia substrates to target for treatment (i.e., adipose) and identifying critical structures to avoid. Optical coherence tomography (OCT) is a real-time imaging modality that aids in addressing this need. Existing approaches for cardiac image analysis mainly rely on fully supervised learning techniques, which suffer from the drawback of workload on labor-intensive annotation process of pixel-wise labeling. To lessen the need for pixel-wise labeling, we develop a two-stage deep learning framework for cardiac adipose tissue segmentation using image-level annotations on OCT images of human cardiac substrates. In particular, we integrate class activation mapping with superpixel segmentation to solve the sparse tissue seed challenge raised in cardiac tissue segmentation. Our study bridges the gap between the demand on automatic tissue analysis and the lack of high-quality pixel-wise annotations. To the best of our knowledge, this is the first study that attempts to address cardiac tissue segmentation on OCT images via weakly supervised learning techniques. Within an in-vitro human cardiac OCT dataset, we demonstrate that our weakly supervised approach on image-level annotations achieves comparable performance as fully supervised methods trained on pixel-wise annotations.


Asunto(s)
Fibrilación Atrial , Corazón , Humanos , Tejido Adiposo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Conocimiento
4.
Ultrasound Med Biol ; 48(12): 2430-2441, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36096896

RESUMEN

The aim of this study was to develop an eyewall curvature- and axial length (AxL)-based algorithm to automate detection (clinician-free) of staphyloma ridge and apex locations using ultrasound (US). Forty-six individuals (with emmetropia, high myopia or pathologic myopia) were enrolled in this study (AxL range: 22.3-39.3 mm), yielding 130 images in total. An intensity-based segmentation algorithm automatically tracked the posterior eyewall, calculating the posterior eyewall local curvature (K) and distance (L) to the transducer and the location of the staphyloma apex. By use of the area under the receiver operator characteristic (AUROC) curve to evaluate the diagnostic ability of eight local statistics derived from K, L and AxL, the algorithm successfully quantified non-uniformity of eye shape with an AUROC > 0.70 for most K-based parameters. The performance of binary classification (staphyloma absence vs. presence) was assessed with the best classifier (the combination of AxL, standard deviation of K and standard deviation of L) yielding a diagnostic validation performance of 0.897, which was comparable to the diagnostic performance of junior clinicians. The staphyloma apex was localized with an average error of 1.35 ± 1.34 mm. Combined with the real-time data acquisition capabilities of US, this method can be employed as a screening tool for clinician-free in vivo staphyloma detection.


Asunto(s)
Miopía Degenerativa , Enfermedades de la Esclerótica , Humanos , Miopía Degenerativa/diagnóstico , Miopía Degenerativa/patología , Tomografía de Coherencia Óptica , Enfermedades de la Esclerótica/diagnóstico , Ojo , Ultrasonografía
5.
Ultrasound Med Biol ; 48(8): 1429-1440, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35537895

RESUMEN

Quantitative ultrasound (QUS) assessment of osteoarthritis (OA) using high-frequency, research-grade single-element ultrasound systems has been reported. The objective of this ex vivo study was to assess the performance of QUS in detecting early OA using a high-frequency linear array transducer. Osteochondral plugs (n = 26) of human articular cartilage were scanned with ExactVu Micro-Ultrasound using an EV29L side-fire transducer. For comparison, the samples were also imaged with SAM200Ex, a custom 40-MHz scanning acoustic microscope with a single-element, focused transducer. Thirteen QUS parameters were derived from the ultrasound data. Magnetic resonance imaging (MRI) data, with T1 and T2 extracted as the quantitative parameters, were also acquired for comparison. Cartilage degeneration was graded from histology and correlated to all quantitative parameters. A maximum Spearman rank correlation coefficient (ρ) of 0.75 was achieved using a combination of ExactVu QUS parameters, while a maximum ρ of 0.62 was achieved using a combination of parameters from SAM200Ex. A maximum ρ of 0.75 was achieved using the T1 and T2 MRI parameters. This study illustrates the potential of a high-frequency linear array transducer to provide a convenient method for early OA screening with results comparable to those of research-grade single-element ultrasound and MRI.


Asunto(s)
Enfermedades de los Cartílagos , Cartílago Articular , Osteoartritis , Enfermedades de los Cartílagos/patología , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/patología , Humanos , Imagen por Resonancia Magnética , Osteoartritis/diagnóstico por imagen , Osteoartritis/patología , Transductores , Ultrasonografía/métodos
6.
J Acoust Soc Am ; 150(1): 183, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34340489

RESUMEN

Quantitative ultrasound methods based on the backscatter coefficient (BSC) and envelope statistics have been used to quantify disease in a wide variety of tissues, such as prostate, lymph nodes, breast, and thyroid. However, to date, these methods have not been investigated in the lung. In this study, lung properties were quantified by BSC and envelope statistical parameters in normal, fibrotic, and edematous rat lungs in vivo. The average and standard deviation of each parameter were calculated for each lung as well as the evolution of each parameter with acoustic propagation time within the lung. The transport mean free path and backscattered frequency shift, two parameters that have been successfully used to assess pulmonary fibrosis and edema in prior work, were evaluated in combination with the BSC and envelope statistical parameters. Multiple BSC and envelope statistical parameters were found to provide contrast between control and diseased lungs. BSC and envelope statistical parameters were also significantly correlated with fibrosis severity using the modified Ashcroft fibrosis score as the histological gold standard. These results demonstrate the potential for BSC and envelope statistical parameters to improve the diagnosis of pulmonary fibrosis and edema as well as monitor pulmonary fibrosis.


Asunto(s)
Fibrosis Pulmonar , Roedores , Animales , Edema , Pulmón/diagnóstico por imagen , Masculino , Fibrosis Pulmonar/diagnóstico por imagen , Ratas , Ultrasonografía
7.
Ultrasound Med Biol ; 46(12): 3426-3439, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32988673

RESUMEN

Diagnosing prostate cancer through standard transrectal ultrasound (TRUS)-guided biopsy is challenging because of the sensitivity and specificity limitations of B-mode imaging. We used a linear support vector machine (SVM) to combine standard TRUS imaging data with acoustic radiation force impulse (ARFI) imaging data, shear wave elasticity imaging (SWEI) data and quantitative ultrasound (QUS) midband fit data to enhance lesion contrast into a synthesized multiparametric ultrasound volume. This SVM was trained and validated using a subset of 20 patients and tested on a second subset of 10 patients. Multiparametric US led to a statistically significant improvements in contrast, contrast-to-noise ratio (CNR) and generalized CNR (gCNR) when compared with standard TRUS B-mode and SWEI; in contrast and CNR when compared with MF; and in CNR when compared with ARFI. ARFI, MF and SWEI also outperformed TRUS B-mode in contrast, with MF outperforming B-mode in CNR and gCNR as well. ARFI, although only yielding statistically significant differences in contrast compared with TRUS B-mode, captured critical qualitative features for lesion identification. Multiparametric US enhanced lesion visibility metrics and is a promising technique for targeted TRUS-guided prostate biopsy in the future.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Biopsia Guiada por Imagen/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Ultrasonografía Intervencional , Humanos , Aumento de la Imagen , Masculino , Estudios Retrospectivos , Máquina de Vectores de Soporte , Ultrasonografía/métodos
8.
Med Image Comput Comput Assist Interv ; 12261: 782-791, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34169298

RESUMEN

Identifying arrhythmia substrates and quantifying their heterogeneity has great potential to provide critical guidance for radio frequency ablation. However, quantitative analysis of heterogeneity on cardiac optical coherence tomography (OCT) images is lacking. In this paper, we conduct the first study on quantifying cardiac tissue heterogeneity from human OCT images. Our proposed method applies a dropout-based Monte Carlo sampling technique to measure the model uncertainty. The heterogeneity information is extracted by decoupling the intra/inter-tissue heterogeneity and tissue boundary uncertainty from the uncertainty measurement. We empirically demonstrate that our model can highlight the subtle features from OCT images, and the heterogeneity information extracted is positively correlated with the tissue heterogeneity information from corresponding histology images.

9.
J Cardiovasc Electrophysiol ; 30(12): 2950-2959, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31661178

RESUMEN

BACKGROUND: Optical coherence tomography (OCT) has the potential to provide real-time imaging guidance for atrial fibrillation ablation, with promising results for lesion monitoring. OCT can also offer high-resolution imaging of tissue composition, but there is insufficient cardiac OCT data to inform the use of OCT to reveal important tissue architecture of the human left atrium. Thus, the objective of this study was to define OCT imaging data throughout the human left atrium, focusing on the distribution of adipose tissue and fiber orientation as seen from the endocardium. METHODS AND RESULTS: Human hearts (n = 7) were acquired for imaging the left atrium with OCT. A spectral-domain OCT system with 1325 nm center wavelength, 6.5 µm axial resolution, 15 µm lateral resolution, and a maximum imaging depth of 2.51 mm in the air was used. Large-scale OCT image maps of human left atrial tissue were developed, with adipose thickness and fiber orientation extracted from the imaging data. OCT imaging showed scattered distributions of adipose tissue around the septal and pulmonary vein regions, up to a depth of about 0.43 mm from the endocardial surface. The total volume of adipose tissue detected by OCT over one left atrium ranged from 1.42 to 28.74 mm3 . Limited fiber orientation information primarily around the pulmonary veins and the septum could be identified. CONCLUSION: OCT imaging could provide adjunctive information on the distribution of subendocardial adipose tissue, particularly around thin areas around the pulmonary veins and septal regions. Variations in OCT-detected tissue composition could potentially assist ablation guidance.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Endocardio/diagnóstico por imagen , Atrios Cardíacos/diagnóstico por imagen , Miocitos Cardíacos/patología , Tomografía de Coherencia Óptica , Anciano , Endocardio/patología , Femenino , Atrios Cardíacos/patología , Tabiques Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Venas Pulmonares/diagnóstico por imagen
10.
J Biophotonics ; 12(12): e201900094, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31400074

RESUMEN

Imaging of cardiac tissue structure plays a critical role in the treatment and understanding of cardiovascular disease. Optical coherence tomography (OCT) offers the potential to provide valuable, high-resolution imaging of cardiac tissue. However, there is a lack of comprehensive OCT imaging data of the human heart, which could improve identification of structural substrates underlying cardiac abnormalities. The objective of this study was to provide qualitative and quantitative analysis of OCT image features throughout the human heart. Fifty human hearts were acquired, and tissues from all chambers were imaged with OCT. Histology was obtained to verify tissue composition. Statistical differences between OCT image features corresponding to different tissue types and chambers were estimated using analysis of variance. OCT imaging provided features that were able to distinguish structures such as thickened collagen, as well as adipose tissue and fibrotic myocardium. Statistically significant differences were found between atria and ventricles in attenuation coefficient, and between adipose and all other tissue types. This study provides an overview of OCT image features throughout the human heart, which can be used for guiding future applications such as OCT-integrated catheter-based treatments or ex vivo investigation of structural substrates.


Asunto(s)
Corazón/diagnóstico por imagen , Miocardio/citología , Tomografía de Coherencia Óptica , Anciano , Colágeno/metabolismo , Femenino , Fibrosis , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Miocardio/metabolismo , Miocardio/patología
11.
Quant Imaging Med Surg ; 9(5): 882-904, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31281782

RESUMEN

Cardiovascular disease is the leading cause of morbidity and mortality in the United States. Knowledge of a patient's heart structure will help to plan procedures, potentially identifying arrhythmia substrates, critical structures to avoid, detect transplant rejection, and reduce ambiguity when interpreting electrograms and functional measurements. Similarly, basic research of numerous cardiac diseases would greatly benefit from structural imaging at cellular scale. For both applications imaging on the scale of a myocyte is needed, which is approximately 100 µm × 10 µm. The use of optical coherence tomography (OCT) as a tool for characterizing cardiac tissue structure and function has been growing in the past two decades. We briefly review OCT principles and highlight important considerations when imaging cardiac muscle. In particular, image penetration, tissue birefringence, and light absorption by blood during in vivo imaging are important factors when imaging the heart with OCT. Within the article, we highlight applications of cardiac OCT imaging including imaging heart tissue structure in small animal models, quantification of myofiber organization, monitoring of radiofrequency ablation (RFA) lesion formation, structure-function analysis enabled by functional extensions of OCT and multimodal analysis and characterizing important substrates within the human heart. The review concludes with a summary and future outlook of OCT imaging the heart, which is promising with progress in optical catheter development, functional extensions of OCT, and real time image processing to enable dynamic imaging and real time tracking during therapeutic procedures.

12.
Opt Express ; 27(10): 14457-14471, 2019 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-31163895

RESUMEN

Quantifying collagen fiber architecture has clinical and scientific relevance across a variety of tissue types and adds functionality to otherwise largely qualitative imaging modalities. Optical coherence tomography (OCT) is uniquely suited for this task due to its ability to capture the collagen microstructure over larger fields of view than traditional microscopy. Existing image processing techniques for quantifying fiber architecture, while accurate and effective, are very slow for processing large datasets and tend to lack structural specificity. We describe here a computationally efficient method for quantifying and visualizing collagen fiber organization. The algorithm is demonstrated on swine atria, bovine anterior cruciate ligament, and human cervical tissue samples. Additionally, we show an improved performance for images with crimped fiber textures and low signal to noise when compared to similar methods.

13.
Biomed Opt Express ; 10(2): 434-448, 2019 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-30800491

RESUMEN

Imaging guidance provided by optical coherence tomography (OCT) could improve the outcomes of atrial fibrillation (AF) ablation by providing detailed structural information of the pulmonary veins, which are critical targets during ablation. In this study, stitched volumetric OCT images of venoatrial junctions from post-mortem human hearts were acquired and compared to histology. Image features corresponding to venous media and myocardial sleeves, as well as fiber orientation and fibrosis, were identified and found to vary between veins. Imaging of detailed tissue architecture could improve understanding of the AF structural substrate within the pulmonary veins and assist the guidance of ablation procedures.

14.
Biophys J ; 114(6): 1477-1489, 2018 03 27.
Artículo en Inglés | MEDLINE | ID: mdl-29590604

RESUMEN

Computational models and experimental optical mapping of cardiac electrophysiology serve as powerful tools to investigate the underlying mechanisms of arrhythmias. Modeling can also aid the interpretation of optical mapping signals, which may have different characteristics with respect to the underlying electrophysiological signals they represent. However, despite the prevalence of atrial arrhythmias such as atrial fibrillation, models of optical electrical mapping incorporating realistic structure of the atria are lacking. Therefore, we developed image-based models of atrial tissue using structural information extracted from optical coherence tomography (OCT), which can provide volumetric tissue characteristics in high resolution. OCT volumetric data of four swine atrial tissue samples were used to develop models incorporating tissue geometry, tissue-specific myofiber orientation, and ablation lesion regions. We demonstrated the use of these models through electrophysiology and photon scattering simulations. Changes in transmural electrical conduction were observed with the inclusion of OCT-derived, depth-resolved fiber orientation. Additionally, the amplitude of optical mapping signals were not found to correspond with lesion transmurality because of lesion geometry and electrical propagation occurring beyond excitation light penetration. This work established a framework for the development of tissue-specific models of atrial tissue derived from OCT imaging data, which can be useful in future investigations of electrophysiology and optical mapping signals with respect to realistic atrial tissue structure.


Asunto(s)
Atrios Cardíacos/diagnóstico por imagen , Tomografía de Coherencia Óptica , Imagen de Colorante Sensible al Voltaje/métodos , Animales , Análisis de Elementos Finitos , Atrios Cardíacos/citología , Método de Montecarlo , Especificidad de Órganos , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...