Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Cardiovasc Diagn Ther ; 14(2): 304-310, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38716316

RESUMEN

The potential clinical usefulness of electron density (ED) imaging, that can be directly estimated using dual-layer spectral computed tomography (CT), has been poorly investigated. We explored whether ED imaging might improve thrombus identification compared to conventional imaging in vitro. We evaluated mechanical thrombectomy material obtained from patients with acute ischemic stroke (AIS) treated in a tertiary level stroke center and immediately fixed in 10% neutral buffered formalin and stored in polystyrene test tubes. The test tubes were immersed in a bucket of water for evaluation by spectral CT, along with scattered control tubes. All images were obtained using a dual-layer detector CT scanner. Each tube was assessed using multiparametric side-by-side view of conventional CT (120 kVp), low monoenergetic imaging (40 keV), and ED images. Fifty-eight polystyrene tubes were analyzed, comprising 52 tubes with thrombectomy material of at least 1 mm2 size obtained from 52 AIS patients, and six control tubes filled with formalin. ED imaging identified accurately the presence of material in all tubes, whereas 2 (3%) of the tubes containing thrombus were not identified by conventional CT, leading to a very good agreement between observers for the presence of material using conventional CT and ED imaging (kappa =0.84, P<0.001). Using ED imaging, thrombus material showed a mean density of 108.8±2.9 percent ED relative to water (%EDW), water had a mean density of 100.0±0.3 %EDW, and formalin a mean density of 103.5±1.2 %EDW. Compared to conventional imaging and 40 keV monoenergetic, ED imaging had a significantly higher signal-to-noise ratio (conventional 10.4±7.0, vs. 40 keV 11.5±8.4, vs. ED 490.0±304.5, P<0.001) and contrast-to-noise ratio (CNR) (conventional 4.3±4.3, vs. 40 keV 5.7±11.2, vs. ED 37.8±29.1, P<0.001). In this in-vitro study, we demonstrated improved visualization of thrombus with ED imaging compared to conventional imaging and low monoenergetic imaging, with a significant increase in CNR.

2.
Interv Neuroradiol ; : 15910199241231018, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38689478

RESUMEN

BACKGROUND: The PEDESTRIAN registry demonstrated high rates of complete long-term occlusion and good clinical outcomes among patients with intracranial aneurysms treated with the pipeline embolization device. The pipeline flex embolization device with shield technology was introduced to minimize thromboembolic complications. In this study, we investigated the safety and effectiveness of pipeline embolization device with shield technology among all patients treated for intracranial aneurysms at our center. METHODS: This was a single-arm retrospective study of prospectively collected data of patients treated with pipeline embolization device with shield technology at our high-volume center between January 2018-January 2021. The primary efficacy endpoint was complete occlusion as measured by a class 1 Raymond-Roy score at 1-year and 2-year follow-up. The primary safety endpoint was major morbidity and neurological mortality up to 1 year following intervention. RESULTS: A total of 328 patients (mean age 56.1 ± 14.7 years; 81.1% female), 80 of whom were previously included in PEDESTRIAN, with 396 aneurysms, were analyzed. A total of 378 devices were deployed, with 93.9% (372/396) of aneurysms requiring only one device. Follow-up angiography was available for 90.2% (296/328) of the procedures after a mean time of 14.0 ± 8.2 months. Complete occlusion was demonstrated for 78.5% (132/168) of aneurysms at 12 months and 90.7% (98/108) at 24 months. The overall rates of major morbidity and neurological mortality after 2 years were 1.5% (5/328) and 0.6% (2/328), respectively. CONCLUSION: Our results demonstrate high rates of complete long-term occlusion among patients treated with pipeline embolization device with shield technology. We also observed low rates of mortality and morbidity consistent with fewer thromboembolic complications with pipeline embolization devices with shield technology.

3.
J Thorac Imaging ; 39(3): 173-177, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37884390

RESUMEN

PURPOSE: Spectral computed tomography (CT) enables improved tissue characterization, although virtually all research has focused on contrast-enhanced examinations. We hypothesized that changes in myocardial tissue related to acute myocardial infarction (AMI) might potentially be identified without the need for contrast administration using electron density (ED) imaging. PATIENTS AND METHODS: This retrospective observational study involved a small series (n = 15) of patients admitted to our institution with a first AMI without signs of hemodynamic instability and identification of a culprit vessel with invasive coronary angiography during the same admission, who also underwent a noncontrast, low-dose chest CT using a dual-layer spectral CT scanner. Images were assessed in search of dark areas with low density on ED imaging, and the mean percentage ED relative to water (%EDW) was calculated. RESULTS: Using a qualitative approach, ED assessment enabled the identification of 11/15 (73%) affected coronary territories, with a sensitivity of 73% (95% CI: 45; 92%) and a specificity of 87% (95% CI: 69; 96%). AMI segments showed significantly lower ED values than the remote myocardium (103.8 ± 0.8 vs 104.3 ± 0.6 %EDW, P < 0.0001), and a threshold below 103.9 %EDW had a sensitivity of 66% and specificity of 79% for the identification of AMI. In a control group of patients without a history of cardiovascular disease, none had areas with focal reduction of ED following the shape of the myocardial wall. CONCLUSIONS: In our preliminary series, ED imaging showed the potential to enable the identification of myocardial tissue changes related to AMI without iodinated contrast requirement.

4.
J Neurointerv Surg ; 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38124177

RESUMEN

BACKGROUND: The aim of this study was to evaluate the overall rates of braid changes associated with flow diverter (FD) treatment for intracranial aneurysms (IAs). Additionally, we sought to provide an overview of the currently reported definitions related to these complications. METHODS: A systematic search was conducted from the inception of relevant literature up to April 2023, encompassing six databases. The included studies focused on patients with IAs treated with FDs. We considered four main outcome measures as FD braid changes: (1) fish-mouthing, (2) device braid narrowing, (3) device braid collapsing, and (4) device braid deformation. The data from these studies were pooled using a random-effects model. RESULTS: A total of 48 studies involving 3572 patients were included in the analysis. Among them, 14 studies (39%) provided definitions for fish-mouthing. However, none of the included studies offered specific definitions for device braid narrowing, collapsing, or deformation, despite reporting rates for these complications in six, five, and three studies, respectively. The pooled rates for braid changes were as follows: 3% (95% CI 2% to 4%, I2=27%) for fish-mouthing, 7% (95% CI 2% to 20%, I2=85%) for narrowing, 1% (95% CI 0% to 3%, I2=0%) for collapsing, and 1% (95% CI 1% to 4%, I2=0%) for deformation. CONCLUSION: The findings of this study suggest that FD treatment for IAs generally exhibits low rates of fish-mouthing, device braid narrowing, collapsing, and deformation. However, the lack of standardized definitions hinders the ability to compare device outcomes objectively, emphasizing the need for uniform definitions for FD braid changes in future prospective studies on FD.

5.
Medicina (B.Aires) ; 83(5): 705-718, dic. 2023. graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1534874

RESUMEN

Resumen Introducción : El inicio de la pandemia COVID-19, obligó a implementar cambios en el sistema de aten ción de los servicios de emergencia. Coincidentemente, en nuestra institución, implementamos el software de inteligencia artificial (IA), RAPID.AI, para el análisis de imágenes en el ataque cerebrovascular isquémico (ACVi). Nuestro objetivo fue evaluar el impacto del uso de la IA junto a los cambios en el triage durante la pandemia por COVID-19 en pacientes con ACVi por oclusión de gran vaso cerebral (OGVC). Métodos : Se crearon 2 grupos de pacientes con ACVi por OGVC tratados con terapia de reperfusión endovenosa más endovascular o terapia endovascu lar directa. Grupo 1: pacientes de enero 2019 a junio 2020; Grupo 2: pacientes de julio 2020 a diciembre de 2021, estudiados con RAPID.AI. Se analizaron datos clínicos, y métricas temporales. Se compararon según hora de arribo de 08:00 a 20:00 h (diurno) vs. 20:01 a 7:59 h (nocturno). Resultados : El grupo 1 comprendió 153 pacientes y el grupo 2 133. En el grupo 2 la métrica puerta-imagen y adquisición de la imagen fueron menores, con menor tiempo puerta-inicio de imagen y puerta-recanalización; los pacientes en horario nocturno presentaron mayor NIHSS y tiempos inicio-ingreso con menor proporción de independencia funcional a 90 días. Conclusiones : El uso de la IA para el análisis de imá genes junto a un menor tiempo puerta-fin de imagen, permitió acortar el intervalo hasta la punción inguinal. En el análisis por horarios durante la pandemia, los pacientes ingresados en horario diurno presentaron métricas puerta-imagen, tiempo de imagen y puerta-recanalización significativamente menores.


Abstract Introduction : The start of the COVID-19 pandemic forced the implementation of changes in the emergency services care system. Concomitantly, at our institution, we implemented the artificial intelligence (AI) software, RAPID.AI, for image analysis in ischemic stroke (IS). Our objective was to evaluate the impact of the use of AI together with the changes in the triage during the COVID-19 pandemic in patients with stroke due to large vessel occlusion (LVO). Methods : We included patients with IS due to LVO treated with intravenous reperfusion therapy plus en dovascular or direct endovascular therapy. Results : Two groups were created. Group 1: patients from January 2019 to June 2020; Group 2: patients from July 2020 to December 2021, studied with RAPID.AI. Clini cal data and temporal metrics were analyzed. They were compared according to arrival time from 08:00 to 20:00 (daytime) vs 20:01 to 7:59 (night). Results: We included 286 patients, 153 in group 1 and 133 in group 2. In group 2, door-image metric and image duration were lower, with shorter door-image onset and door-recanalization times; patients who arrived at night had higher NIHSS and longer time from onset-to-door with lower propor tion of functional independence at 90 days (mRS ≤ 2). Conclusions : The use of AI for image analysis along with a shorter door to end of image time allowed to reduce the interval to groin puncture. In the analysis by hours during the pandemic, patients admitted in daytime hours had significantly lower door to image, image time acquisition, and door to recanalization metrics.

6.
Medicina (B Aires) ; 83(5): 705-718, 2023.
Artículo en Español | MEDLINE | ID: mdl-37870328

RESUMEN

INTRODUCTION: The start of the COVID-19 pandemic forced the implementation of changes in the emergency services care system. Concomitantly, at our institution, we implemented the artificial intelligence (AI) software, RAPID.AI, for image analysis in ischemic stroke (IS). Our objective was to evaluate the impact of the use of AI together with the changes in the triage during the COVID-19 pandemic in patients with stroke due to large vessel occlusion (LVO). METHODS: We included patients with IS due to LVO treated with intravenous reperfusion therapy plus endovascular or direct endovascular therapy. RESULTS: Two groups were created. Group 1: patients from January 2019 to June 2020; Group 2: patients from July 2020 to December 2021, studied with RAPID.AI. Clinical data and temporal metrics were analyzed. They were compared according to arrival time from 08:00 to 20:00 (daytime) vs 20:01 to 7:59 (night). RESULTS: We included 286 patients, 153 in group 1 and 133 in group 2. In group 2, door-image metric and image duration were lower, with shorter door-image onset and door-recanalization times; patients who arrived at night had higher NIHSS and longer time from onset-to-door with lower proportion of functional independence at 90 days (mRS = 2). CONCLUSIONS: The use of AI for image analysis along with a shorter door to end of image time allowed to reduce the interval to groin puncture. In the analysis by hours during the pandemic, patients admitted in daytime hours had significantly lower door to image, image time acquisition, and door to recanalization metrics.


Introducción: El inicio de la pandemia COVID-19, obligó a implementar cambios en el sistema de atención de los servicios de emergencia. Coincidentemente, en nuestra institución, implementamos el software de inteligencia artificial (IA), RAPID.AI, para el análisis de imágenes en el ataque cerebrovascular isquémico (ACVi). Nuestro objetivo fue evaluar el impacto del uso de la IA junto a los cambios en el triage durante la pandemia por COVID-19 en pacientes con ACVi por oclusión de gran vaso cerebral (OGVC). Métodos: Se crearon 2 grupos de pacientes con ACVi por OGVC tratados con terapia de reperfusión endovenosa más endovascular o terapia endovascular directa. Grupo 1: pacientes de enero 2019 a junio 2020; Grupo 2: pacientes de julio 2020 a diciembre de 2021, estudiados con RAPID.AI. Se analizaron datos clínicos, y métricas temporales. Se compararon según hora de arribo de 08:00 a 20:00 h (diurno) vs. 20:01 a 7:59 h (nocturno). Resultados: El grupo 1 comprendió 153 pacientes y el grupo 2 133. En el grupo 2 la métrica puerta-imagen y adquisición de la imagen fueron menores, con menor tiempo puerta-inicio de imagen y puerta-recanalización; los pacientes en horario nocturno presentaron mayor NIHSS y tiempos inicio-ingreso con menor proporción de independencia funcional a 90 días. Conclusiones: El uso de la IA para el análisis de imágenes junto a un menor tiempo puerta-fin de imagen, permitió acortar el intervalo hasta la punción inguinal. En el análisis por horarios durante la pandemia, los pacientes ingresados en horario diurno presentaron métricas puerta-imagen, tiempo de imagen y puertarecanalización significativamente menores.


Asunto(s)
Isquemia Encefálica , COVID-19 , Accidente Cerebrovascular , Humanos , Pandemias , Trombectomía/métodos , Inteligencia Artificial , Accidente Cerebrovascular/terapia , Accidente Cerebrovascular/epidemiología , Resultado del Tratamiento , Tiempo de Tratamiento , Isquemia Encefálica/terapia , Estudios Retrospectivos
8.
Rev. argent. cir ; 115(2): 137-146, abr. 2023. graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1449389

RESUMEN

RESUMEN Antecedentes : los aneurismas de arterias viscerales (AAV) tienen una frecuencia baja (0,1 a 2%). Hasta un 25% puede presentarse como rotura, con una alta mortalidad (hasta 70%). La terapia endovascular ha ganado terreno y se recomienda como primera opción según las últimas guías. Hoy en día, es posible adaptarse a casi cualquier anatomía utilizando tecnología cerebral. Objetivo : describir la experiencia y enfoque en el manejo endovascular de AAV, con resultados a corto, mediano y largo plazo. Material y métodos : llevamos a cabo una evaluación retrospectiva de pacientes tratados por AAV verdaderos por vía endovascular en un solo centro entre 2010 y 2020, con un seguimiento mínimo de 6 meses. Resultados : analizamos 19 procedimientos en 18 pacientes (9 hombres y 9 mujeres). La edad promedio fue 61,9 años; el promedio de tiempo de internación fue 1,94 días y el promedio de seguimiento de 40 meses. La arteria más involucrada fue la esplénica (n = 9, 50%). El tamaño aneurismático promedio fue 30,1 mm. La estrategia terapéutica más utilizada fue colocación de diversor de flujo (n = 8, 42,1%). Dos pacientes fueron reintervenidos (11,1%). Las tasas de exclusión completa fueron del 47,4%, 68,4% y 94,7% a los 3, 6 y 12 meses, respectivamente. No hubo casos de mortalidad a 30 días ni mortalidad relacionada con el aneurisma durante el seguimiento. Conclusión : el tratamiento endovascular de los AAV es seguro y eficaz. Sin embargo, se debe contar con la tecnología adecuada, para la planificación preoperatoria y el tratamiento.


ABSTRACT Background : the prevalence of visceral artery aneurysms (VAAs) is low (0.1 to 2%). Up to 25% may present as rupture which is associated with high mortality (up to 70%). Endovascular treatment has gained ground and is even considered the first option according to the most recent recommendations. Nowadays, almost any anatomy can be approached with endovascular techniques used to treat intracranial aneurysms. Objective : the aim of our study was to describe the experience and approach for the endovascular management of VAAs with short-, mid-, and long-term results. Material and methods : we conducted a retrospective evaluation of patients with true VAAs undergoing endovascular treatment in a single center between 2010 and 2020 who were followed up for a minimum of 6 months. Results : we analyzed 19 procedures in 18 patients (9 men and 9 women). Mean age was 61.9 years; mean length of hospital stay was 1.94 days and mean follow-up was 40 months. The splenic artery was the vessel most affected (n = 9, 50%). Mean aneurysm size was 30.1 mm. Flow diversion was the strategy most used (n = 8, 42.1%). Two patients required reintervention (11%). Complete exclusion rate was 38.4%, 47.4%, 68.4% and 94.7% at 3, 6 and 12 months, respectively. There were no cases of mortality within the first 30 days and no aneurysm-related mortality during the follow-up period. Conclusion : endovascular treatment of VAAs is a safe and efficient strategy but requires adequate technology for preoperative planning and treatment.

11.
J Neurointerv Surg ; 15(9): 924-930, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35999050

RESUMEN

BACKGROUND: Embolization of the middle meningeal artery (MMA) is a promising minimally invasive technique that is gaining traction in the treatment of chronic subdural hematoma. Unfortunately, the human meninges and associated arteries are significantly larger than those of conventional laboratory animals, making the development of a clinically relevant animal model for testing of embolization agents elusive. OBJECTIVE: To introduce the posterior intercostal artery (PIA) model in swine and provide anatomical, angiographic, histological, and procedural data to validate its relevance in modeling the human MMA. METHODS: In human cadaveric specimens, 3D angiograms of the internal maxillary arteries (n=6) were obtained and the dura with MMA were harvested and histologically processed. Angiographic and histologic data of the human MMA were compared with the swine PIA (three animals). Then, embolization of the PIA (n=48 arteries) was conducted with liquid embolization agent (Onyx, Medtronic), and angiographic and histological results were assessed acutely (four animals) and after 30 days (two animals). RESULTS: The human MMA has equivalent diameter, length, branching pattern, 3D trajectory, and wall structure to those of swine PIAs. Each swine has 12 to 14 PIAs (6-7 per side) suitable for acute or chronic embolization, which can be performed with high fidelity using the same devices, agents, and techniques currently used to embolize the MMA. The arterial wall structure and the acute and chronic histological findings in PIAs after embolization are comparable to those of humans. CONCLUSIONS: This PIA model in swine could be used for research and development; objective benchmarking of agents, devices, and techniques; and in the training of neurointerventionalists.


Asunto(s)
Embolización Terapéutica , Hematoma Subdural Crónico , Humanos , Animales , Porcinos , Arterias Meníngeas/diagnóstico por imagen , Embolización Terapéutica/métodos , Arteria Maxilar , Angiografía , Duramadre , Hematoma Subdural Crónico/terapia
12.
Interv Neuroradiol ; : 15910199221123282, 2022 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-36168255

RESUMEN

BACKGROUND: Traditional endovascular treatments of giant intracranial aneurysms are associated with high rates of complications and retreatment. Our objective was to examine the safety and long-term efficacy of the Pipeline Embolization Device for treatment of these aneurysms. METHODS: This retrospective study using the IntrePED database included all patients with giant intracranial aneurysms treated with the Pipeline device between July 2008 and February 2013. Efficacy outcomes were stratified by using the Raymond-Roy Occlusion Classification. Predefined safety outcomes included spontaneous rupture of the target aneurysm; ipsilateral intracranial hemorrhage; ischemic stroke; parent artery stenosis; and sustained cranial neuropathy. RESULTS: Sixty-six embolizations were performed to treat 63 giant intracranial aneurysms (including 2 ruptured): 49 (77.8%) in the anterior and 14 (22.2%) in the posterior circulation. The median follow-up was 22.4 (0.1-60.5) months. Class I angiographic occlusion was achieved in 72.0% (36/50). The neurological morbidity/mortality rate was 23.8% (15/63), with higher rates in the posterior circulation than in the anterior circulation (22.4% vs. 28.6%). Among seven deaths, five had neurological causes. The procedure-related neurological morbidity and mortality rates were 22.7% (15/66) and 7.6% (5/66), respectively. The spontaneous rupture rate was 4.5% (3/66). Two spontaneous ruptures (1 death), 4/4 postprocedural intracranial hemorrhages, and 6/9 ischemic events occurred within 30 days. In-stent stenosis and new-onset cranial neuropathy were not observed during the angiographic follow-up period. CONCLUSIONS: Although procedure-related neurological morbidity/mortality rates were not insignificant, this study confirms the feasibility and long-term efficacy of the Pipeline Embolization Device to treat giant intracranial aneurysms.

13.
J Stroke Cerebrovasc Dis ; 31(8): 106595, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35716524

RESUMEN

OBJECTIVES: Mechanical thrombectomy (MT) after intravenous thrombolysis (IV-tPA) is an effective and cost-saving treatment for stroke due to large vessel occlusion. However, rates of MT use are low in Argentina. This study was designed to estimate the economic value and the budget impact of incorporating MT after thrombolysis, simulating scenarios from Argentinian compulsory social health insurance (Obras Sociales) and private insurances (Empresas de Medicina Prepaga). MATERIALS AND METHODS: We adapted a previously published cost-utility and budget-impact (CUA and BIA) model to the Argentinian setting. The CUA was carried out for a lifetime horizon with efficacy inputs from the SWIFT PRIME clinical trial. For seven possible health states, we identified local costs (Argentinian Pesos AR$), utility (QALY), and transition/distribution probabilities (5% discounted rate) and performed deterministic and probabilistic sensitivity analyses. The BIA was based on a six-step approach and a static model for a five-year horizon, and two scenarios (staggered growth and no growth). RESULTS: Despite higher incremental procedure costs, IV-tPA and MT was dominant over IV-tPA alone (AR$1,049,062 overall savings). Cost-effectiveness remained in the deterministic sensitivity analysis (100% probability of cost-effectiveness). Increased MT procedure volume resulted in savings in years three (0.96%), four (2.6%), and five (4.4%). By year five, 1,280 patients were treated with MT (versus 480) with overall savings of 1.8% (AR$817,244,417). CONCLUSIONS: MT after IV-tPA is cost-effective in Argentina. Savings offset the incremental hospitalization and long-term costs from the third year onwards. With increased, access the superior efficacy of MT mitigates future disability and comorbidity, reducing overall expenses.


Asunto(s)
Isquemia Encefálica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Argentina , Isquemia Encefálica/terapia , Análisis Costo-Beneficio , Humanos , Accidente Cerebrovascular/tratamiento farmacológico , Accidente Cerebrovascular/terapia , Trombectomía/métodos , Resultado del Tratamiento
14.
J Clin Med ; 11(11)2022 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-35683615

RESUMEN

During the past three decades, neuroendovascular therapy has evolved from a focus on new disease concepts to revised treatment strategies and, ultimately, to versatile new technologies [...].

15.
Rev Cardiovasc Med ; 23(3): 93, 2022 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-35345260

RESUMEN

BACKGROUND: Hyperacute cardiac imaging of patients with acute ischemic stroke (AIS), though desirable, is impractical. Using delayed-enhancement, low-dose, non-gated, chest spectral computed tomography scans (DESCT), we explored the prevalence and patterns of incidental myocardial late iodine enhancement (LIE) and embolic sources, and their relationship with stroke etiology. METHODS: Since July 2020, DESCT was performed after cerebrovascular CT angiography (CTA) among patients with suspected AIS undergoing CT using a dual-layer spectral scanner, without additional contrast administration. Images were analyzed using monoenergetic reconstructions and iodine density maps, and the myocardial extracellular volume fraction (ECV, %) was calculated. RESULTS: Eighty patients with AIS were included. DESCT identified a cardiac thrombi in 6 patients (7.5%), and a complex aortic plaque in 4 (5%) cases; reclassifying 5 embolic strokes of uncertain source (28% of ESUS) to cardioembolic (CE, n = 3) and non-CE (n = 2) etiologies. LIE was identified in 38 (48%) patients, most commonly (82%) of ischemic pattern. We did not identify significant relationships between AIS etiology and the presence, pattern, and extent of LIE (p > 0.05); ECV (p = 0.56), severe aortic (p = 0.25) or valvular (p = 0.26) disease, or the extent of coronary calcification (p = 0.39). Patients with evidence of major cardiovascular DESCT findings had higher rates of all-cause death at 90 days (42% vs. 19%, p = 0.037). CONCLUSIONS: In this study, hyperacute cardiac imaging of AIS with DESCT identified a high prevalence of incidental cardiac disease predominantly involving LIE of ischemic etiology and mostly not related to the stroke etiology.


Asunto(s)
Yodo , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Miocardio , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/epidemiología , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/métodos
17.
J Neurosurg ; : 1-8, 2022 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-35120326

RESUMEN

OBJECTIVE: Transradial access (TRA) is commonly utilized in neurointerventional procedures. This study compared the technical and clinical outcomes of the use of TRA versus those of transfemoral access (TFA) for intracranial aneurysm embolization with the Woven EndoBridge (WEB) device. METHODS: This is a secondary analysis of the Worldwide WEB Consortium, which comprises multicenter data related to adult patients with intracranial aneurysms who were managed with the WEB device. These aneurysms were categorized into two groups: those who were treated with TRA or TFA. Patient and aneurysm characteristics and technical and clinical outcomes were compared between groups. Propensity score matching (PSM) was used to match groups according to the following baseline characteristics: age, sex, subarachnoid hemorrhage, aneurysm location, bifurcation aneurysm, aneurysm with incorporated branch, neck width, aspect ratio, dome width, and elapsed time since the last follow-up imaging evaluation. RESULTS: This study included 682 intracranial aneurysms (median [interquartile range] age 61.3 [53.0-68.0] years), of which 561 were treated with TFA and 121 with TRA. PSM resulted in 65 matched pairs. After PSM, both groups had similar characteristics, angiographic and functional outcomes, and rates of retreatment, thromboembolic and hemorrhagic complications, and death. TFA was associated with longer procedure length (median 96.5 minutes vs 72.0 minutes, p = 0.006) and fluoroscopy time (28.2 minutes vs 24.8 minutes, p = 0.037) as compared with TRA. On the other hand, deployment issues were more common in those treated with TRA, but none resulted in permanent complications. CONCLUSIONS: TRA has comparable outcomes, with shorter procedure and fluoroscopy time, to TFA for aneurysm embolization with the WEB device.

18.
J Clin Med ; 11(3)2022 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-35160333

RESUMEN

Coil embolization has become a well-established option for the treatment of intracranial aneurysms. Yet, wide-neck bifurcation aneurysms (WNBAs) remain a challenge. The pCONUS is the first generation of a stent-like implant for the bridging of WNBAs to enable coiling. The pToWin study was a prospective, single-arm, multicenter study conducted to analyze the safety and efficacy of the pCONUS in the treatment of WNBAs. The primary effectiveness endpoint was the rate of adequate occlusion of the aneurysm at 3-6 and 7-12 months. The primary safety endpoint was the occurrence of major ipsilateral stroke or neurological death during the follow-up. A total of 115 patients were included. Aneurysm locations were the middle cerebral artery in 52 (45.2%), the anterior communicating artery in 35 (30.4%), the basilar artery in 23 (20%), the internal carotid artery terminus in three (2.6%), and the pericallosal artery in two (1.7%) patients. Treatment was successfully performed in all but one patient. The morbi-mortality rate was 1.9% and 2.3% at 3-6 and 7-12 months, respectively. Of the aneurysms, 75.0% and 65.6% showed adequate occlusion at 3-6 and 7-12 months, respectively. pCONUS offers a safe and reasonably effective treatment of WNBAs, demonstrated by acceptable adequate aneurysm occlusion and low rates of adverse neurologic events.

19.
J Neurointerv Surg ; 14(10): 968-972, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34987072

RESUMEN

BACKGROUND: There is considerable overlap of contributors to cardiovascular disease and the development of age-related macular degeneration (AMD). Compromised ocular microcirculation due to aging and vascular disease contribute to retinal dysfunction and vision loss. Decreased choroidal perfusion is evident in eyes with dry AMD and is thought to play a role in retinal pigment epithelial dysfunction, the rate of development of geographic atrophy, and the development of neovascularization. The aim of the study was to demonstrate that AMD is correlated with a compromised blood flow in the ocular pathway and show OA angioplasty as a potential treatment of late-stage AMD. METHODS: Based on the potential for the ophthalmic artery (OA) to be an anatomical target for the treatment of AMD as outlined above, five patients were found to be eligible for compassionate use treatment, presenting clinically significant late-stage AMD with profound vision loss in one or both eyes, and are included in this retrospective study. RESULTS: OA narrowing, or significant calcium burden at the ophthalmic segment of the internal carotid artery compromising the origin of the OA was confirmed in all cases. Subsequent OA cannulation was achieved in all patients with some difficulty. Subjective patient reports indicated that all patients perceived a benefit following the procedure; however, improved postoperative visual acuity did not confirm that perceived benefit for one of the patients. CONCLUSIONS: Feasibility and safety of the OA angioplasty were demonstrated, and a benefit perceived in five patients with profound vision loss and a desire to achieve improved quality of life. A clinical trial with controlled schedule, imaging, and methodologies is needed to confirm these results.


Asunto(s)
Degeneración Macular , Arteria Oftálmica , Angioplastia , Humanos , Degeneración Macular/tratamiento farmacológico , Degeneración Macular/terapia , Arteria Oftálmica/diagnóstico por imagen , Arteria Oftálmica/cirugía , Calidad de Vida , Estudios Retrospectivos
20.
Minerva Med ; 113(6): 950-958, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34309338

RESUMEN

BACKGROUND: Collective risk factors such as climate and pollution impact on the risk of acute cardiovascular events, including ST-elevation myocardial infarction (STEMI). There is limited data however on the precise temporal and independent association between these factors and STEMI, and the potentially interacting role of government policies against Coronavirus disease 2019 (COVID-19), especially for Latin America. METHODS: We retrospectively collected aggregate data on daily STEMI admissions at 10 tertiary care centers in the Buenos Aires metropolitan area, Argentina, from January 1, 2017 to November 30, 2020. Daily measurements for temperature, humidity, atmospheric pressure, wind direction, wind speed, and rainfall, as well as carbon monoxide (CO), nitrogen dioxide, and particulate matter <10 µm (PM10), were retrieved. Exploratory analyses focused on key COVID-19-related periods (e.g. first case, first lockdown), and Stringency Index quantifying the intensity of government policy response against COVID-19. RESULTS: A total of 1498 STEMI occurred over 1430 days, for an average of 0.12 STEMI per center (decreasing from 0.130 in 2018 to 0.102 in 2020, P=0.016). Time series analysis showed that lower temperature and higher concentration of CO and PM10 were all significantly associated with an increased rate of STEMI (all P<0.05), whereas COVID-19 outbreak, lockdown, and stringency of government policies were all inversely associated with STEMI (all P<0.05). Notably, environmental features impacted as early as 28 days before the event (all P<0.05), even if same or prior day associations proved stronger (all P<0.05). Multivariable analysis suggested that maximum temperature (P=0.001) and PM10 (P=0.033) were the strongest predictor of STEMI, even after accounting for COVID-19-related countermeasures (P=0.043). CONCLUSIONS: Lower temperature and higher concentrations of CO and PM10 are associated with significant increases in the rate of STEMI in a large Latin American metropolitan area. The reduction in STEMI cases seen during the COVID-19 pandemic is at least in part mediated by improvements in pollution, especially reductions in PM10.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , COVID-19 , Infarto del Miocardio con Elevación del ST , Humanos , Contaminantes Atmosféricos/efectos adversos , Contaminantes Atmosféricos/análisis , Contaminación del Aire/efectos adversos , COVID-19/epidemiología , Infarto del Miocardio con Elevación del ST/epidemiología , Infarto del Miocardio con Elevación del ST/terapia , Infarto del Miocardio con Elevación del ST/inducido químicamente , Estudios Retrospectivos , Pandemias , Control de Enfermedades Transmisibles , Material Particulado
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...