Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Neurol Neuroimmunol Neuroinflamm ; 11(3): e200217, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38547427

RESUMEN

BACKGROUND AND OBJECTIVES: Epstein-Barr virus (EBV) has been strongly implicated in the pathogenesis of multiple sclerosis (MS). Despite this, there are no routinely used tests to measure cellular response to EBV. In this study, we analyzed the cellular response to EBV nuclear antigen-1 (EBNA-1) in people with MS (pwMS) using a whole blood assay. METHODS: This cross-sectional study took place in a dedicated MS clinic in a university hospital. We recruited healthy controls, people with epilepsy (PWE), and pwMS taking a range of disease-modifying treatments (DMTs) including natalizumab, anti-CD20 monoclonal antibodies (mAbs), dimethyl fumarate (DMF), and also treatment naïve. Whole blood samples were stimulated with commercially available PepTivator EBNA1 peptides and a control virus-cytomegalovirus (CMV) peptide. We recorded the cellular response to stimulation with both interferon gamma (IFN-γ) and interleukin-2 (IL-2). We also compared the cellular responses to EBNA1 with IgG responses to EBNA1, viral capsid antigen (VCA), and EBV viral load. RESULTS: We recruited 86 pwMS, with relapsing remitting MS, in this group, and we observed a higher level of cellular response recorded with IFN-γ (0.79 IU/mL ± 1.36) vs healthy controls (0.29 IU/mL ± 0.90, p = 0.0048) and PWE (0.17 IU/mL ± 0.33, p = 0.0088). Treatment with either anti-CD20 mAbs (0.28 IU/mL ± 0.57) or DMF (0.07 IU/mL ± 0.15) resulted in a cellular response equivalent to control levels or in PWE (p = 0.26). The results of recording IL-2 response were concordant with IFN-γ: with suppression also seen with anti-CD20 mAbs and DMF. By contrast, we did not record any differential effect of DMTs on the levels of IgG to either EBNA-1 or VCA. Nor did we observe differences in cellular response to cytomegalovirus between groups. DISCUSSION: This study demonstrates how testing and recording the cellular response to EBNA-1 in pwMS may be beneficial. EBNA-1 stimulation of whole blood samples produced higher levels of IFN-γ and IL-2 in pwMS compared with controls and PWE. In addition, we show a differential effect of currently available DMTs on this response. The functional assay deployed uses whole blood samples with minimal preprocessing suggesting that employment as a treatment response measure in clinical trials targeting EBV may be possible.


Asunto(s)
Antígenos Nucleares del Virus de Epstein-Barr , Herpesvirus Humano 4 , Esclerosis Múltiple , Humanos , Anticuerpos Antivirales , Antígenos Virales , Proteínas de la Cápside , Estudios Transversales , Infecciones por Virus de Epstein-Barr/complicaciones , Infecciones por Virus de Epstein-Barr/inmunología , Antígenos Nucleares del Virus de Epstein-Barr/inmunología , Herpesvirus Humano 4/inmunología , Inmunidad Celular , Inmunoglobulina G , Interferón gamma , Interleucina-2 , Esclerosis Múltiple/tratamiento farmacológico , Esclerosis Múltiple/virología
2.
Ir J Med Sci ; 191(3): 1089-1092, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34235708

RESUMEN

INTRODUCTION: Serological SARS-CoV-2 assays have an important role in guiding the pandemic response. This research aimed to compare the performance of 2 antinucleocapsid assays. METHODS: Serum from 49 HCWs was analysed at baseline and 6 months using the Abbott diagnostics SARS-CoV-2 IgG assay and the Roche Diagnostics Elecsys Anti-SARS-CoV-2 total antibody assay. RESULTS: At baseline, 14/49 participants (29%) demonstrated antibody reactivity using the Abbott assay. At 6 months, 4/14 participants (29%) continued to demonstrate reactivity. A total of 14/49 (29%) participants had detectable antibodies at baseline using the Roche assay. In total, 13/14 (93%) of participants demonstrated antibody reactivity at 6 months. The Abbott assay showed a statistically significant difference in the signal-to-threshold values of baseline reactive samples when repeated at 6 months (p = 0.001). This was not seen with the Roche assay (p = 0.51). CONCLUSION: In this small study, the Roche Diagnostics Elecsys Anti-SARS-CoV-2 total antibody assay appears superior in performance to the Abbott diagnostics SARS-CoV-2 IgG assay in accurately detecting participants with a history of confirmed COVID-19 disease at 6 months follow-up. This finding should be born in mind in the planning of future seroprevalence studies, especially when considering the use of anti-nucleocapsid assays.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Antivirales , COVID-19/diagnóstico , Personal de Salud , Humanos , Inmunoglobulina G , Sensibilidad y Especificidad , Estudios Seroepidemiológicos
3.
Microbiol Spectr ; 9(2): e0039121, 2021 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-34585976

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies are an excellent indicator of past COVID-19 infection. As the COVID-19 pandemic progresses, retained sensitivity over time is an important quality in an antibody assay that is to be used for the purpose of population seroprevalence studies. We compared 5,788 health care worker (HCW) serum samples by using two serological assays (Abbott SARS-CoV-2 anti-nucleocapsid immunoglobulin G (IgG) and Roche anti-SARS-CoV-2 anti-nucleocapsid total antibody) and a subset of samples (all Abbott assay positive or grayzone, n = 485) on Wantai SARS-CoV-2 anti-spike antibody enzyme-linked immunosorbent assay (ELISA). For 367 samples from HCW with a previous PCR-confirmed SARS-CoV-2 infection, we correlated the timing of infection with assay results. Overall, seroprevalence was 4.2% on Abbott and 9.5% on Roche. Of those with previously confirmed infection, 41% (150/367) and 95% (348/367) tested positive on Abbott and Roche, respectively. At 21 weeks (150 days) after confirmed infection, positivity on Abbott started to decline. Roche positivity was retained for the entire study period (33 weeks). Factors associated (P ≤ 0.050) with Abbott seronegativity in those with previous PCR-confirmed infection included sex (odds ratio [OR], 0.30 male ; 95% confidence interval [CI], 0.15 to 0.60), symptom severity (OR 0.19 severe symptoms; 95% CI, 0.05 to 0.61), ethnicity (OR, 0.28 Asian ethnicity; 95% CI, 0.12 to 0.60), and time since PCR diagnosis (OR, 2.06 for infection 6 months previously; 95% CI, 1.01 to 4.30). Wantai detected all previously confirmed infections. In our population, Roche detected antibodies up to at least 7 months after natural infection with SARS-CoV-2. This finding indicates that the Roche total antibody assay is better suited than Abbott IgG assay to population-based studies. Wantai demonstrated high sensitivity, but sample selection was biased. The relationship between serological response and functional immunity to SARS-CoV-2 infection needs to be delineated. IMPORTANCE As the COVID-19 pandemic progresses, retained sensitivity over time is an important quality in an antibody assay that is to be used for the purpose of population seroprevalence studies. There is a relative paucity of published literature in this field to help guide public health specialists when planning seroprevalence studies. In this study, we compared results of 5,788 health care worker blood samples tested by using two assays (Roche and Elecsys, anti-nucleocapsid antibody) and by testing a subset on a third assay (Wantai enzyme-linked immunosorbent assay [ELISA] anti-spike antibody). We found significant differences in the performance of these assays, especially with distance in time from PCR-confirmed COVID-19 infection, and we feel these results may significantly impact the choice of assay for others conducting similar studies.


Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Proteínas de la Nucleocápside de Coronavirus/inmunología , SARS-CoV-2/inmunología , Glicoproteína de la Espiga del Coronavirus/inmunología , Adulto , Estudios Transversales , Ensayo de Inmunoadsorción Enzimática , Femenino , Personal de Salud/estadística & datos numéricos , Humanos , Inmunoglobulina G/sangre , Masculino , Persona de Mediana Edad , Fosfoproteínas/inmunología , Sensibilidad y Especificidad , Estudios Seroepidemiológicos , Adulto Joven
4.
Sex Transm Dis ; 46(4): e35-e37, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30676483

RESUMEN

This is the first prevalence study of Mycoplasma genitalium and antimicrobial resistance study in Ireland. In urine samples from men who have sex with men (n = 400) attending a sexually transmitted disease clinic in Dublin, the prevalence of M. genitalium was 3% (12 of 400 specimens; 95% confidence interval, 1.3-4.7%), and the prevalences of macrolide resistance (75%), fluoroquinolone resistance (33.3%), and multidrug resistance (33.3%) were very high.


Asunto(s)
Antibacterianos/farmacología , Farmacorresistencia Bacteriana Múltiple/genética , Infecciones por Mycoplasma/epidemiología , Mycoplasma genitalium/efectos de los fármacos , Adulto , Estudios Transversales , ADN Bacteriano , Fluoroquinolonas/farmacología , Homosexualidad Masculina , Humanos , Irlanda/epidemiología , Macrólidos/farmacología , Masculino , Persona de Mediana Edad , Mutación , Infecciones por Mycoplasma/microbiología , Infecciones por Mycoplasma/orina , Mycoplasma genitalium/genética , Prevalencia , ARN Ribosómico 23S/genética , Adulto Joven
5.
Genome Announc ; 5(23)2017 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-28596392

RESUMEN

Here, we report the draft genome assemblies of 14 azithromycin-resistant Neisseria gonorrhoeae clinical isolates, representing the first such strains identified in Ireland. Among these isolates are the first reported highly resistant strains (MIC >256 mg/liter), which both belonged to the ST1580 sequence type.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA