Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Org Chem ; 70(17): 6944-7, 2005 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-16095322

RESUMEN

A novel high-yielding Zn/CuI-mediated coupling method of alkyl halides with vinyl sulfones, vinyl sulfonates, and vinyl sulfonamides is described. This protocol is applicable for primary, secondary, and tertiary alkyl iodides and bromides. Alkyl chlorides and aryl and vinyl halides were unreactive under the reaction conditions. Formamide was found to be a superior solvent for obtaining high yields.


Asunto(s)
Cobre/química , Halógenos/química , Sulfonamidas/química , Sulfonas/química , Ácidos Sulfónicos/química , Zinc/química , Espectroscopía de Resonancia Magnética
2.
J Pharm Sci ; 92(3): 529-35, 2003 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-12587114

RESUMEN

A simple and safe prototype apparatus was designed and adapted for the in situ determination of the moisture content of a cytotoxic compound (9-fluorenylmethyl-protected doxorubicin-peptide conjugate, or Fm-DPC) by near-infrared absorbance spectroscopy during optimization of the chemical isolation procedure. The cytotoxic nature of the compound restricts one's ability to safely sample such drying processes for more traditional means of moisture determination for fear of hazardous solids dusting, hence in situ sampling approaches are of great importance. These concerns also exist for the process development laboratory, where despite the smaller scale of operations, the volume of experiments (hence cytotoxic samples) required to define a chemical process is often more significant. In this application, partial least squares regression was used with Karl Fischer volumetric titration analysis to generate a calibration model. Although pronounced differences in cake density were observed as a function of the buffer selected for the isolation process, the model still achieved a standard error of calibration of 0.63% w/w and a standard error of prediction of 0.99% (w/w). These results demonstrated the versatility of the prototype apparatus/data processing approach to model Fm-DPC drying under extremely variable conditions, as inherently expected during the investigational laboratory development of a chemical process.


Asunto(s)
Doxorrubicina/análisis , Doxorrubicina/química , Tecnología Farmacéutica/métodos , Doxorrubicina/toxicidad , Preparaciones Farmacéuticas/análisis , Preparaciones Farmacéuticas/química , Espectroscopía Infrarroja Corta/instrumentación , Espectroscopía Infrarroja Corta/métodos , Tecnología Farmacéutica/instrumentación , Agua/análisis , Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...