Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
J Clin Med ; 13(8)2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38673588

RESUMEN

Background: The anatomical reconstruction of the wrist is the aim when treating distal radius fractures. Current literature on the importance of preoperative reduction in fractures that are treated operatively is limited. Methods: This study investigated the effect of the preoperative closed reduction of distal radius fractures on the day of trauma and the time to surgery on postoperative palmar inclination. A total of eighty patients (48 females and 32 males, mean age 55.6 years) were studied retrospectively. All patients were treated with an open reduction and internal fixation. The palmar inclination angle was measured using X-rays by two investigators, and the interobservers and pre- and post-reduction parameters were compared. Results: When the surgical management of closed distal radius fractures is required, neither initial repositioning nor a delay of up to 14 days to the surgical treatment influences postoperative palmar inclination. Conclusions: The significance of preoperative reduction of distal radius fractures without neurovascular or extensive soft tissue damage is limited and is not leading to improved outcomes. When surgery is about to be performed, surgeons should carefully consider if reduction is really vital preoperatively. Level of evidence: III.

2.
Injury ; 55(4): 111486, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38447478

RESUMEN

OBJECTIVE: The trochlea is of great importance for the stability of the elbow and its fixation in low transcondylar fractures of the distal humerus is especially challenging. The aim of this study was to determine the optimal trochlea fixation in double plate osteosynthesis of intraarticular distal humerus fractures. METHODS: A low transcondylar, C3-type distal humerus fracture was created in 20 fresh-frozen human cadaveric humeri. The samples were then randomly divided into two groups of 10 specimens each. Double plate osteosynthesis was performed in both groups. In group A, the two most distal screws of the lateral plate were inserted into the trochlea fragment. In group B, these screws did not extend into the trochlea. Displacement under cyclic loading and ultimate failure loads were determined for all specimens. RESULTS: Group A showed significantly less displacement under cyclic loading in each measurement interval (0.92 mm vs. 1.53 mm after 100 cycles, p = 0 0.006; 1.10 mm vs. 1.84 mm after 1000 cycles, p = 0.007; 1.18 mm vs. 1.98 mm after 2000 cycles, p = 0.008). The ultimate failure load was significantly higher in group A than in group B (345.61 ± 120.389 N vs. 238.42 ± 131.61 N, p = 0.037). CONCLUSIONS: Fixation of the trochlea with interdigitating screws in double plate osteosynthesis of low-condylar type C distal humerus fractures results in superior construct stability. LEVEL OF EVIDENCE: not applicable (biomechanical).


Asunto(s)
Fracturas Humerales Distales , Fracturas del Húmero , Humanos , Fracturas del Húmero/cirugía , Fenómenos Biomecánicos , Fijación Interna de Fracturas/métodos , Húmero/cirugía , Placas Óseas , Tornillos Óseos , Cadáver
3.
Surg Radiol Anat ; 46(4): 473-482, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38329521

RESUMEN

PURPOSE: Anatomical variations of the concave shaped retrocondylar ulnar groove (RUG) can contribute to ulnar nerve instability. However, there are currently limited available standardized data describing the anatomy of the RUG based on radiologic imaging, such as computed tomography (CT). This study aims to provide a comprehensive description and classification of RUG anatomy based on RUG angle measurements. METHODS: 400 CT scans of the elbows of adults showing no signs of osseous damage were evaluated. RUG angles were measured in four anatomically defined axial planes that spanned from the proximal to the distal end of the RUG. Furthermore, distance measurements at the medial epicondyle were conducted. A classification system for the RUG is proposed based on the acquired RUG angles, aiming to categorize the individual angles according to the 25th and 75th percentiles. RESULTS: RUG angles were significantly larger in males compared to females (p < 0.001) accompanied by larger distances including the off-set and height of the medial epicondyle (p < 0.001). RUG angles decreased from proximal to distal locations (p < 0.05). CONCLUSION: This study revealed that men exhibited larger RUG angles compared to women, indicating a less-concave shape of the RUG in men. Introducing an objective RUG classification system can improve our understanding of anatomical variations and potentially find application in diagnostics and preoperative planning.


Asunto(s)
Articulación del Codo , Nervio Cubital , Masculino , Adulto , Humanos , Femenino , Nervio Cubital/anatomía & histología , Articulación del Codo/anatomía & histología , Codo/inervación , Tomografía Computarizada por Rayos X
4.
Arthrosc Tech ; 13(1): 102834, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38312892

RESUMEN

Stiffness and pain secondary to end-stage dysfunctional osteoarthritis of the elbow can pose a therapeutic dilemma. Although total elbow arthroplasty is successful in older patients with low functional demand, alternatives to joint replacement must be found in the younger, more active individual. Interposition arthroplasty provides a salvage option for young, high-demand patients who hope to minimize functional restrictions of the affected extremity. The procedure traditionally involves release of both collateral ligaments and the joint capsule, resulting in a higher risk for postoperative instability and complications. The present unilateral technique demonstrates an approach maintaining the integrity of the medial or lateral collateral ligament while still allowing secure graft fixation. Stability can usually be preserved without ligament reconstruction or hinged external fixation if the elbow was stable before surgery.

5.
J Hand Surg Am ; 49(1): 8-14, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37978963

RESUMEN

PURPOSE: The purpose of the study was to determine if the sphericity of the thumb metacarpophalangeal (MCP) joint influences the joint's rotational axis (RA) and elongation patterns of the ulnar collateral ligament (UCL). METHODS: Ulnar collateral ligament origins and attachments of 28 fresh-frozen cadaveric thumbs were marked with a radiopaque marker. Lateral radiographs were obtained in neutral and 20°, 40°, and 60° of flexion. The dorsal and palmar joint gap and the length of four different UCL portions were digitally measured in all flexion states. The RA was determined by the intersection of the midshaft axis of the proximal phalanx in neutral and flexion states. Sphericity of the MCP joint was assessed using morphometric parameters. Joints were grouped as round or flat. Differences in all measured parameters between groups were analyzed. RESULTS: During flexion, the dorsal joint gap increased by 322% in flat joints and 163% in round joints. The palmar joint gap decreased to 45% in flat joints and to 87% in round joints. The RA was at 29% of metacarpal height and 96% of metacarpal length in flat joints and at 40% of height and 86% of length in round joints. Maximum UCL elongation (111%) was noted at 40° flexion in the dorsal proper UCL in flat joints and at 60° flexion in the accessory UCL (117%) in round joints. CONCLUSIONS: In flat MCP joints, the RA is more dorsal and distal in the metacarpal head compared to round joints, resulting in a hinged flexion motion. Elongation of the UCL is highest at end flexion in round joints and highest at midflexion in flat joints. CLINICAL RELEVANCE: The different kinematics of flat and round MCP joints may contribute to the understanding of the pathophysiology of UCL ruptures. The propensity of this injury and the position in which they occur may be affected by the MCP joint morphology.


Asunto(s)
Ligamento Colateral Cubital , Ligamentos Colaterales , Humanos , Pulgar , Ligamento Colateral Cubital/diagnóstico por imagen , Ligamento Colateral Cubital/lesiones , Ligamentos Colaterales/lesiones , Fenómenos Biomecánicos , Articulación Metacarpofalángica
6.
Surg Radiol Anat ; 45(12): 1587-1592, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37837464

RESUMEN

PURPOSE: A comprehensive analysis of the morphology of fractures of the coronoid process (CP) can aid diagnosis and guide treatment. The involvement of the radial notch of the ulna (RN)-e.g., in anterolateral facet fractures and transverse fractures of the CP-may influence the biomechanical conditions of the proximal radioulnar joint. However, the morphometric relation between the CP and the RN and the extent to what the proximal radioulnar joint can be affected in these types of fractures is unknown. METHODS: A total of 113 embalmed, cadaveric ulnae were dissected. All soft tissue was removed. Strictly lateral, high-resolution photographs were taken and digitally analyzed. The height of the CP and its relation to the RN was measured. Sex differences and correlations between measured parameters were calculated. RESULTS: Mean height of the CP was 16 mm (range: 12-23 mm; SD: 2). Mean height of the RN was 16 mm (11-25 mm; 2.2). The 50% mark of the CP corresponded to 18% (0-56%; 11.2) of the height of the RN. No significant differences were found between male and female specimens. CONCLUSION: The RN of the ulna extends only to a small part to the CP. Transverse or anterolateral fractures of less than 50% of the coronoid process may involve only a small portion of the proximal radioulnar joint.


Asunto(s)
Articulación del Codo , Fracturas del Radio , Fracturas del Cúbito , Humanos , Masculino , Femenino , Cúbito/anatomía & histología , Articulación del Codo/anatomía & histología , Extremidad Superior
7.
J Biomech ; 158: 111766, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37633217

RESUMEN

Elbow trauma is often accompanied by a loss of independence in daily self-care activities, negatively affecting patients' quality of life. Finite element models can help gaining profound knowledge about native human joint mechanics, which is crucial to adequately restore joint functionality after severe injuries. Therefore, a finite element model of the elbow is required that includes both the radio-capitellar and ulno-trochlear joint and is subjected to loads realistic for activities of daily living. Since no such model has been published, we aim to fill this gap. For comparison, 8 intact cadaveric elbows were subjected to loads of up to 1000 N, after they were placed in an extended position. At each load step, the displacement of the proximal humerus relative to the distal base plate was measured with optical tracking markers and the joint pressure was measured with a pressure mapping sensor. Analogously, eight finite element models were created based on subject-specific CT scans of the corresponding elbow specimens. The CT scans were registered to the positions of tantalum beads in the experiment. The optically measured displacements were applied as boundary conditions. We demonstrated that the workflow can predict the experimental contact pressure distribution with a moderate correlation, the experimental peak pressures in the correct joints and the experimental stiffness with moderate to excellent correlation. The predictions of peak pressure magnitude, contact area and load share on the radius require improvement by precise representation of the cartilage geometry and soft tissues in the model, and proper initial contact in the experiment.


Asunto(s)
Actividades Cotidianas , Codo , Humanos , Análisis de Elementos Finitos , Calidad de Vida , Fenómenos Biomecánicos
9.
Unfallchirurgie (Heidelb) ; 126(9): 694-699, 2023 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-37278730

RESUMEN

So far there are no clear recommendations for postoperative follow-up treatment of elbow injuries and individual concepts are often chosen. Due to the susceptibility for posttraumatic or postoperative impaired movement up to stiffness of the elbow joint, early mobilization plays a crucial role. Therefore, mid-term to long-term immobilization should be avoided. In addition to the necessary cryotherapy and compression therapy for swelling and pain control in the initial period, early actively assisted mobilization now has an important role. Additionally, active flexion and extension in an overhead position, so-called overhead motion, was recently established. After a short initial immobilization in a cast, mostly 3-5 days, the cast is changed to a dynamic movement orthosis, which when possible enables a free range of motion. Care is taken that varus and valgus loading is avoided. In general loading is avoided for the first 6 weeks, followed by a stepwise increase of loading up to maximum loading. In most cases return to sport is possible after 3 months. After implantation of an elbow prosthesis a maximum loading of 5 kg for single loading and 1 kg for repetitive loading are recommended.


Asunto(s)
Traumatismos del Brazo , Lesiones de Codo , Articulación del Codo , Humanos , Estudios de Seguimiento , Articulación del Codo/cirugía , Movimiento
10.
Unfallchirurgie (Heidelb) ; 126(9): 687-693, 2023 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-37278731

RESUMEN

The term Monteggia-like lesions or Monteggia equivalent injuries includes fractures of the proximal ulna with dislocation and dislocation fractures of the radial head from the proximal radio-ulnar joint. The complexity of the injury requires a dedicated understanding of the anatomical structures and their biomechanical properties. Particularly due to the rarity, the complication and revision rates are high. A conservative treatment is not usually effective. Three-dimensional imaging by computed tomography is part of the surgical preparation. The goal of surgical treatment is osteosynthetic reconstruction of the fractures and restoration of joint congruency. In cases of nonreconstructable radial head fractures, radial head arthroplasty may be necessary. In addition to reconstruction of the bony stabilizers, refixation of the ligamentous structures is essential for treatment success. The combination of complex fracture patterns and possible dislocation positions in the ulnohumeral, radiohumeral and proximal radio-ulnar joints poses a great challenge to the surgeon. The most frequent complications are peri-implant infections, implant failure, loss of reduction, stiffness or instability. Especially the anatomical configuration of the proximal ulna is complex and requires accurate reconstruction. Therefore, reconstruction of the proximal ulna in length and rotation, including the coronoid process, is considered to be a key factor in the surgical treatment of Monteggia-like injuries.


Asunto(s)
Lesiones de Codo , Articulación del Codo , Luxaciones Articulares , Fracturas del Radio , Humanos , Luxaciones Articulares/diagnóstico por imagen , Articulación del Codo/cirugía , Fracturas del Radio/cirugía , Radio (Anatomía)/lesiones
11.
Unfallchirurgie (Heidelb) ; 126(9): 700-705, 2023 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-37270731

RESUMEN

BACKGROUND: Monteggia-like fractures (MLF) are complex injuries with high complication rates and frequently unsatisfying clinical results. Total elbow arthroplasty (TEA) represents the only option to salvage the functional requirements in some patients with pronounced posttraumatic arthropathy. This case series provides clinical results of TEA following failed treatment of MLF. METHODS: All patients who underwent TEA from 2017 to 2022 for failed treatment of MLF were retrospectively included in this study. Complications and revisions before and after TEA and functional results, measured by the Broberg/Morrey score, were evaluated. RESULTS: In this study 9 patients with a mean age of 68 (±7; 54-79) years were included. The mean follow-up was 12 (±9; 2-27) months. The main reasons leading to posttraumatic arthropathy were chronic infections (44.4%), bony instability due to coronoid deficiency (33.3%) or a combined coronoid and radial head deficiency (22.2%) and non-union of the proximal ulna with radial head necrosis (11.1%). The mean number of surgical revisions between primary fixation and TEA was 2.7 (±1.8; 0-6). The revision rate following TEA was 44%. The mean Broberg/Morrey score at the time of the latest follow-up was 83 (±10; 71-97) points. CONCLUSION: Chronic infection and coronoid deficiency are the main reasons for posttraumatic arthropathy after MLF leading to TEA. While the overall clinical results are satisfying, the indications should be reserved for selected cases due to high revision rates.


Asunto(s)
Artritis , Artroplastia de Reemplazo de Codo , Fractura de Monteggia , Anciano , Humanos , Artritis/etiología , Artroplastia de Reemplazo de Codo/efectos adversos , Codo/cirugía , Fijación Interna de Fracturas/efectos adversos , Fractura de Monteggia/diagnóstico por imagen , Estudios Retrospectivos , Insuficiencia del Tratamiento , Resultado del Tratamiento , Persona de Mediana Edad
12.
Arch Orthop Trauma Surg ; 143(10): 6201-6208, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37341804

RESUMEN

INTRODUCTION: The SARS-CoV-2 pandemic and its associated lockdowns had a profound effect on orthopedic trauma emergencies. This study aimed to investigate the patient volume and injury patterns at a level-one trauma center during the SARS-CoV-2 pandemic and compare them to the pre-pandemic conditions. MATERIALS AND METHODS: A retrospective chart review of all patients who presented to the orthopedic trauma emergency department of a level-one trauma center in Cologne, Germany within a 2 year period from March 16th, 2019 to March 15th, 2020 (pre-pandemic control) and from March 16th, 2020 and March 15th, 2021 (pandemic) was performed. The pandemic year was separated into three periods: (1) first lockdown, (2) between lockdowns and (3) second lockdown. The absolute numbers of patient presentations, the Manchester triage score (MTS) and the relative proportion of patients with structural organ injuries, fractures and dislocations, of polytraumatized patients, of hospital admissions, of subsequent emergency or semi-elective surgeries and of work-related accidents were evaluated in comparison to the pre-pandemic control. RESULTS: A total of 21,642 patient presentations were included in this study. Significantly less weekly orthopedic trauma emergency patient presentations were recorded during the pandemic (p < 0.01). The MTS was significantly lower during the first lockdown and between lockdowns (p < 0.01). The proportional incidence of overall structural organ injuries, fractures and dislocations, of upper limb fractures/dislocations, of hospital admissions and of patients requiring surgery was significantly increased during the pandemic (p ≤ 0.03). The proportional incidence of work-related injuries was significantly decreased during the pandemic (p < 0.01). CONCLUSIONS: Orthopedic trauma emergency presentations were reduced during the SARS-CoV-2 pandemic. Due to the reluctancy of patients to visit the emergency department during the pandemic, the proportions of relevant injuries in general and of upper limb injuries in particular as well as of patients requiring hospital admission and trauma-related surgery were significantly increased.


Asunto(s)
COVID-19 , Fracturas Óseas , Luxaciones Articulares , Humanos , SARS-CoV-2 , Centros Traumatológicos , COVID-19/epidemiología , Pandemias/prevención & control , Estudios Retrospectivos , Urgencias Médicas , Control de Enfermedades Transmisibles , Servicio de Urgencia en Hospital , Fracturas Óseas/epidemiología , Fracturas Óseas/cirugía , Luxaciones Articulares/epidemiología
13.
J Hand Surg Eur Vol ; 48(8): 768-772, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37005740

RESUMEN

Studies on graft reconstruction techniques for ruptured thumb metacarpophalangeal (MCP) ulnar collateral ligaments (UCL) do not consider the variety of MCP joint morphology. Optimal reconstruction method for flat MCP joints is therefore unclear. Twenty-four fresh-frozen, human thumbs were tested for flexion, extension and valgus stability of the MCP joint. After resection of the UCL, four reconstruction methods, differing in the metacarpal origin and phalangeal attachment, were performed on each specimen, which were then tested again in the same way. Specimens were grouped as 'round' or 'flat' depending on morphometric parameters and group differences were analysed. In flat joints, only the non-anatomical Glickel reconstruction and a modified Fairhurst reconstruction maintained normal mobility and stability. In round joints, only the Glickel reconstruction maintained normal mobility and stability. The original Fairhurst method and a modification with the origin palmar in the metacarpus were disadvantageous in both flat and round joints.


Asunto(s)
Ligamento Colateral Cubital , Ligamentos Colaterales , Humanos , Ligamento Colateral Cubital/cirugía , Pulgar/cirugía , Ligamentos Colaterales/cirugía , Rango del Movimiento Articular , Articulación Metacarpofalángica/cirugía
14.
Surg Radiol Anat ; 45(5): 571-580, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36892617

RESUMEN

The radiologic evaluation of the sagittal angulation of the distal humerus is commonly based on standard lateral radiographs. However, lateral radiographs do not allow to examine the lateral angulation of the capitulum and the trochlea, separately. Although this problem could be approached via computed tomography, there are no data available describing the difference between the angulation of the capitulum and trochlea. Therefore, we aimed to assess sagittal angles of the capitulum and trochlea in relation to the humeral shaft based on 400 CT-scans of the elbow in healthy adults. Angles were measured in sagittal planes at the capitulum center and three anatomically defined trochlea locations and were spanned between the axis of the joint component and the humerus shaft. Angles were tested for differences between measurement locations and correlation with patient characteristics (age, sex, trans-epicondylar distance). Angles increased from lateral to medial measurement locations (107.4 ± 9.6°, 167.4 ± 8.2°, 171.8 ± 7.3°, 179.1 ± 7.0°; p < 0.05). Largest angle differences were detected between the capitulum and trochlea with smallest angles measured at the capitulum. Patient characteristics did not correlate with angles (p > 0.05). Intra-rater-reliability was r = 0.79-0.86. As CT-imaging allows to distinguish between sagittal capitulum and trochlea locations, it might benefit the radiologic diagnostic of sagittal malalignments of the distal humerus at the capitulum and trochlea, separately.


Asunto(s)
Articulación del Codo , Húmero , Adulto , Humanos , Reproducibilidad de los Resultados , Húmero/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Articulación del Codo/diagnóstico por imagen , Radiografía
15.
Clin Biomech (Bristol, Avon) ; 101: 105867, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36584578

RESUMEN

BACKGROUND: Knee Spacers are required in two-stage revision surgery of periprosthetic joint infection of the knee. Extended bone and ligamentous defects are often temporarily arthrodised via a static spacer. Regarding their weight-bearing potential and construction, there is no current consent. Our aim was to evaluate three individual static spacer variants with regard to their axial loading capacity. METHODS: The static spacer variants were tested in a cadaver model. One after the other, a spacer with metal-reinforced rods, a spacer without metal reinforcement and a rod-less spacer were implanted and tested up to an axial loading of 1000 Newton. Target parameters were plastic deformation, stiffness and spacer movement at both the femoral and tibial surface. Loading was applied up to 1000 Newton. Radiological controls of the bone substance were performed. FINDINGS: The spacer variants did not differ regarding deformation, stiffness or spacer movement. However, deformation increased significantly with the axial load in all spacer variants. Radiographs showed no fracture or spacer-dislocation resulting from testing. INTERPRETATION: While the spacer reinforcement or the sheer presence of a rod did not influence the axial loading capacity in this in vitro study, weightbearing should be discouraged to limit further bone erosion.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Articulación de la Rodilla/cirugía , Tibia/cirugía , Fémur/cirugía , Artritis Infecciosa/cirugía , Reoperación/métodos
16.
Arch Orthop Trauma Surg ; 143(5): 2519-2527, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35731264

RESUMEN

INTRODUCTION: Open reduction and internal fixation (ORIF) of comminuted coronal shear fractures of the distal humerus is challenging. When a concomitant lateral condyle fracture is present, it may be used for a trans-fracture approach to facilitate exposure and fracture reduction. This study aimed to investigate the frequency of lateral condyle fractures in coronal shear fractures of the distal humerus and analyze fracture reduction, fracture union and clinical results following ORIF through a trans-fracture approach. MATERIALS AND METHODS: All adult patients who underwent treatment for an acute distal humerus fracture during a three-year period in our level-one trauma center were identified. All fractures were classified according to the Orthopaedic Trauma Association (OTA/AO) fracture classification system and all B3 fractures were classified according to the Dubberley classification. B3 fractures with a concomitant radial condyle fracture were identified. The clinical and radiological results, (Mayo Elbow Performance Score = MEPS, Visual Analogue Scale = VAS, range of motion), complications and revision surgeries were analyzed. RESULTS: 53 patients (mean age 52 ± 19 years) were identified. 13 fractures (24.5%) were B3 fractures. Four of them (30.8%) had a concomitant radial condyle fracture. All of these patients underwent ORIF with headless cannulated compression screws and a (postero-)lateral locking plate through a trans-fracture approach. At a minimum follow-up of 24 months, the MEPS was 88 ± 12 points, the VAS was 2 ± 1 and the range of motion was 118° ± 12°. All fractures showed anatomic reduction. One patient developed partial avascular necrosis and underwent arthrolysis at 6 months. One patient underwent partial hardware removal and lateral collateral ligament bracing at 6 months. CONCLUSIONS: Lateral condyle fractures are present in about one third of coronal shear fractures of the distal humerus. This injury can be used for a trans-fracture approach to facilitate exposure and to reliably achieve anatomic fracture reduction.


Asunto(s)
Articulación del Codo , Fracturas Conminutas , Fracturas del Húmero , Adulto , Humanos , Persona de Mediana Edad , Anciano , Fracturas del Húmero/cirugía , Fijación Interna de Fracturas/métodos , Húmero , Reducción Abierta/métodos , Articulación del Codo/cirugía , Fracturas Conminutas/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Rango del Movimiento Articular
17.
Arch Orthop Trauma Surg ; 143(2): 857-863, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35064826

RESUMEN

BACKGROUND: Lateral collateral ligament (LCL) tears are frequently observed in fractures and dislocations of the elbow. Recent biomechanical evidence suggests that additional ligament augmentation may improve repair stability. The aim of this biomechanical in-vitro study was to compare the resistance of a locking suture repair of the LCL with a ligament augmentation technique. MATERIAL AND METHODS: Eight fresh frozen cadaveric elbows were evaluated for stability against varus/posterolateral rotatory forces (3 Nm). A strain gauge (µm/m; negative values) was placed at the origin and insertion of the lateral ulnar collateral ligament (LUCL) and cyclic loading was performed for 1000 cycles. We analyzed three distinct scenarios: (A) native LCL, (B) locking transosseou suture repair of the LCL, (C) simple LCL repair with additional ligament augmentation of the LUCL. RESULTS: The mean measured strain was - 416.1 µm/m (A), - 618 µm/m (B) and - 288.5 µm/m (C) with the elbow flexion at 90°; the strain was significantly higher in scenario B compared to C (p = .01). During the cyclic load (1000) the mean measured strain was - 523.1 µm/m (B) and - 226.3 µm/m (C) with the elbow flexion at 60°; the strain was significantly higher in scenario B compared to C (p = .01). No significant difference between the first and the last cycles was observed (p = .09; p = .07). One failure of the LCL repair was observed after 1000 cycles; none of the ligament augmentations failed. CONCLUSION: Ligament augmentation (C) provides higher resistance compared to the native LCL (A) and to the locking suture repair technique (B). Both techniques, however, hold up during 1000 cycles. While ligament augmentation might enhance the primary stability of the repair, future clinical studies have to show whether this increase in resistance leads to negative effects like higher rates of posttraumatic elbow stiffness. LEVEL OF EVIDENCE: Basic science study, biomechanics.


Asunto(s)
Ligamentos Colaterales , Articulación del Codo , Inestabilidad de la Articulación , Ligamentos Laterales del Tobillo , Humanos , Codo , Inestabilidad de la Articulación/cirugía , Articulación del Codo/cirugía , Rango del Movimiento Articular , Fenómenos Biomecánicos , Cadáver , Suturas , Ligamentos Colaterales/cirugía , Ligamentos Colaterales/lesiones
18.
Arch Orthop Trauma Surg ; 143(5): 2467-2474, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35579703

RESUMEN

INTRODUCTION: In regard of surgical training, the reproducible simulation of life-like proximal humerus fractures in human cadaveric specimens is desirable. The aim of the present study was to develop a technique that allows simulation of realistic proximal humerus fractures and to analyse the influence of rotator cuff preload on the generated lesions in regards of fracture configuration. MATERIALS AND METHODS: Ten cadaveric specimens (6 left, 4 right) were fractured using a custom-made drop-test bench, in two groups. Five specimens were fractured without rotator cuff preload, while the other five were fractured with the tendons of the rotator cuff preloaded with 2 kg each. The humeral shaft and the shortened scapula were potted. The humerus was positioned at 90° of abduction and 10° of internal rotation to simulate a fall on the elevated arm. In two specimens of each group, the emergence of the fractures was documented with high-speed video imaging. Pre-fracture radiographs were taken to evaluate the deltoid-tuberosity index as a measure of bone density. Post-fracture X-rays and CT scans were performed to define the exact fracture configurations. Neer's classification was used to analyse the fractures. RESULTS: In all ten cadaveric specimens life-like proximal humerus fractures were achieved. Two III-part and three IV-part fractures resulted in each group. The preloading of the rotator cuff muscles had no further influence on the fracture configuration. High-speed videos of the fracture simulation revealed identical fracture mechanisms for both groups. We observed a two-step fracture mechanism, with initial impaction of the head segment against the glenoid followed by fracturing of the head and the tuberosities and then with further impaction of the shaft against the acromion, which lead to separation of the tuberosities. CONCLUSION: A high energetic axial impulse can reliably induce realistic proximal humerus fractures in cadaveric specimens. The preload of the rotator cuff muscles had no influence on initial fracture configuration. Therefore, fracture simulation in the proximal humerus is less elaborate. Using the presented technique, pre-fractured specimens are available for real-life surgical education. LEVEL OF EVIDENCE: III.


Asunto(s)
Fracturas del Húmero , Fracturas del Hombro , Humanos , Manguito de los Rotadores/cirugía , Fracturas del Hombro/cirugía , Hombro , Húmero , Cadáver
19.
Arch Orthop Trauma Surg ; 143(5): 2485-2491, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35635575

RESUMEN

BACKGROUND: Complex proximal humeral fracture ranks among the most common fracture types, especially in elderly patients. In locked plate fixation of proximal humerus fractures, the calcar is deciding for screws providing further medial column support. To date, the biomechanical effect of the length of these calcar screws is not well known. The purpose of this study was to analyze the effect of long calcar screws on fresh frozen prefractured cadaveric specimens. METHODS: In the present biomechanical study, 8 pairs of cadaveric proximal humeri were fractured identically using a custom-made fracture simulator. ORIF was performed using a locking plate (PHILOS; Fa. Synthes). The specimens were tested in a biomechanical setup under increased axial load without any calcar screws installed, with short calcar screws and long calcar screws installed. Strain gages (4-wire-120 Ohm, Fa. Vishay) mounted on the locking plate were used to evaluate the fixation strain and to give an estimate for primary stability.. RESULTS: The measured strain of the locking plate without calcar screws (804,64 µm/m) at maximum load (200 N) was significantly higher than with short (619,07 µm/m; p = 0.02) or long calcar screws (527,31 µm/m; p = 0.007). Additionally, strain with short calcar screws was noticeably higher in comparison to long calcar screws (619,07 µm/m vs. 527,31 µm/m; p = 0.03). CONCLUSION: Use of calcar screws improves the stability of realistically impacted 3-part varus humeral fractures. Long calcar screws that are positioned as close as possible to the joint provide further primary stability compared to short calcar screws. LEVEL OF EVIDENCE: Basic science study.


Asunto(s)
Fijación Interna de Fracturas , Fracturas del Hombro , Humanos , Anciano , Tornillos Óseos , Fracturas del Hombro/cirugía , Húmero/cirugía , Placas Óseas , Cadáver , Fenómenos Biomecánicos
20.
OTA Int ; 5(2 Suppl): e188, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35949265

RESUMEN

Objectives: In view of the increased attention to reverse shoulder arthroplasty (rTSA) as a treatment for complex proximal humeral fractures in the elderly, the present study analyzes in-hospital complications and the postoperative management of rTSA versus open reduction and internal fixation (ORIF). Methods: We retrospectively reviewed patients hospitalized from 2016 to 2018 for proximal humeral fractures (ICD-9 codes: S42.21), III- and IV-part, who underwent an ORIF with locking plates, rTSA or nonoperative treatment. In-hospital complications and postoperative management in both groups were included in the analysis. Results: We included n 190 patients (ORIF 90, rTSA 71, nonoperative 29), more likely to be female (82.1% vs 17.9%; P < .01) with an average age of 82years (min. 72, max. 99; SD 6.4). The ORIF and the rTSA groups showed comparable complication rates (15.6% vs 15%, P = .87) but with a significantly shorter hospital stay (8.6 vs 11.5days; P = .01) and shorter duration of surgery (72.9 vs 87.2 minutes; P = .01) in the ORIF group. Significantly more patients after ORIF achieved an independent life postoperatively (53.3% vs 40.8%; P = .013). Conclusions: In this retrospective analysis, ORIF is related to a shorter duration of surgery, a shorter hospital stay and a higher likelihood of independence. Despite the popularity of the rTSA, ORIF remains a reliable treatment option for proximal humeral fractures in the elderly.Level of evidence: III.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...