Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
IEEE Trans Med Imaging ; 33(4): 875-81, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24710156

RESUMEN

Proton radiography has applications in patient alignment and verification procedures for proton beam radiation therapy. In this paper, we report an experiment which used 200 MeV protons to generate proton energy-loss and scattering radiographs of a hand phantom. The experiment used the first-generation proton computed tomography (CT) scanner prototype, which was installed on the research beam line of the clinical proton synchrotron at Loma Linda University Medical Center. It was found that while both radiographs displayed anatomical details of the hand phantom, the energy-loss radiograph had a noticeably higher resolution. Nonetheless, scattering radiography may yield more contrast between soft and bone tissue than energy-loss radiography, however, this requires further study. This study contributes to the optimization of the performance of the next-generation of clinical proton CT scanners. Furthermore, it demonstrates the potential of proton imaging (proton radiography and CT), which is now within reach of becoming available as a new, potentially low-dose medical imaging modality.


Asunto(s)
Mano/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Protones , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/instrumentación
2.
J Hum Nutr Diet ; 26(4): 315-28, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23731266

RESUMEN

BACKGROUND: Existing nutritional guidelines suggest that protein requirements of adults with stage five chronic kidney disease undergoing haemodialysis (HD) or peritoneal dialysis (PD) are increased as a result of protein losses during dialysis. The present review aimed to update previous guidance and develop evidence-based practice guidelines on the protein requirements of adults undergoing maintenance dialysis. METHODS: Following a PICO approach (Participants or Population, Intervention or Exposure, Comparison and Outcome), four research questions were formulated to investigate the total protein requirement and protein quality required by adults undergoing HD and PD. A comprehensive, systematic review was undertaken using the databases Medline, EMBASE and the Cochrane Library from 2005 to September 2009 for HD studies and from 1997 to September 2009 for PD studies. RESULTS: The literature search yielded 2931 studies, which were assessed for inclusion. Following appraisal, 19 studies in HD and 18 studies in PD met the inclusion criteria and were systematically reviewed. Limited good quality evidence supports the recommendations that: (i) adults undergoing maintenance HD require a minimum protein intake of 1.1 g kg(-1) ideal body weight (IBW) per day; and (ii) adults undergoing maintenance PD require a minimum protein intake of 1.0-1.2 kg(-1) IBW per day, in conjunction with an adequate energy intake. There were no studies that addressed the quality of protein for either HD or PD. CONCLUSIONS: Evidence suggests that nutritional status may be maintained with lower protein intakes than previously recommended. However, the evidence base is limited and further randomised controlled trials are required to establish the optimal protein intake for dialysis patients.


Asunto(s)
Dieta , Proteínas en la Dieta/administración & dosificación , Fallo Renal Crónico/terapia , Necesidades Nutricionales , Diálisis Peritoneal , Diálisis Renal , Dietética , Ingestión de Energía , Medicina Basada en la Evidencia , Humanos , Estado Nutricional , Guías de Práctica Clínica como Asunto , Reino Unido
3.
Nucl Instrum Methods Phys Res A ; 699: 205-210, 2013 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-23264711

RESUMEN

We describe a new head scanner developed for Proton Computed Tomography (pCT) in support of proton therapy treatment planning, aiming at reconstructing an accurate map of the stopping power (S.P.) in a phantom and, in the future, in patients. The system consists of two silicon telescopes which track the proton before and after the phantom/patient, and an energy detector which measures the residual energy or range of the proton to reconstruct the Water Equivalent Path Length (WEPL) in the phantom. Based on the experience of the existing prototype and extensive Geant4 simulations and CT reconstructions, the new pCT scanner will support clinically useful proton fluxes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA