Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Res Notes ; 17(1): 62, 2024 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-38433186

RESUMEN

OBJECTIVE: Data from DNA genotyping via a 96-SNP panel in a study of 25,015 clinical samples were utilized for quality control and tracking of sample identity in a clinical sequencing network. The study aimed to demonstrate the value of both the precise SNP tracking and the utility of the panel for predicting the sex-by-genotype of the participants, to identify possible sample mix-ups. RESULTS: Precise SNP tracking showed no sample swap errors within the clinical testing laboratories. In contrast, when comparing predicted sex-by-genotype to the provided sex on the test requisition, we identified 110 inconsistencies from 25,015 clinical samples (0.44%), that had occurred during sample collection or accessioning. The genetic sex predictions were confirmed using additional SNP sites in the sequencing data or high-density genotyping arrays. It was determined that discrepancies resulted from clerical errors (49.09%), samples from transgender participants (3.64%) and stem cell or bone marrow transplant patients (7.27%) along with undetermined sample mix-ups (40%) for which sample swaps occurred prior to arrival at genome centers, however the exact cause of the events at the sampling sites resulting in the mix-ups were not able to be determined.


Asunto(s)
Servicios de Laboratorio Clínico , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Trasplante de Médula Ósea , Genotipo , Laboratorios
2.
Res Sq ; 2023 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-37790445

RESUMEN

Objective: Data from DNA genotyping via a 96-SNP panel in a study of 25,015 clinical samples were utilized for quality control and tracking of sample identity in a clinical sequencing network. The study aimed to demonstrate the value of both the precise SNP tracking and the utility of the panel for predicting the sex-by-genotype of the participants, to identify possible sample mix-ups. Results: Precise SNP tracking showed no sample swap errors within the clinical testing laboratories. In contrast, when comparing predicted sex-by-genotype to the provided sex on the test requisition, we identified 110 inconsistencies from 25,015 clinical samples (0.44%), that had occurred during sample collection or accessioning. The genetic sex predictions were confirmed using additional SNP sites in the sequencing data or high-density genotyping arrays. It was determined that discrepancies resulted from clerical errors, samples from transgender participants and stem cell or bone marrow transplant patients along with undetermined sample mix-ups.

3.
Nat Methods ; 15(7): 531-534, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29941871

RESUMEN

Comparison of sequencing data from a tumor sample with data from a matched germline control is a key step for accurate detection of somatic mutations. Detection sensitivity for somatic variants is greatly reduced when the matched normal sample is contaminated with tumor cells. To overcome this limitation, we developed deTiN, a method that estimates the tumor-in-normal (TiN) contamination level and, in cases affected by contamination, improves sensitivity by reclassifying initially discarded variants as somatic.


Asunto(s)
Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Neoplasias/diagnóstico , Neoplasias/genética , Análisis de Secuencia de ADN/métodos , Simulación por Computador , Humanos , Mutación
4.
Nat Commun ; 4: 2672, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24157732

RESUMEN

The recent development of a semiconductor-based, non-optical DNA sequencing technology promises scalable, low-cost and rapid sequence data production. The technology has previously been applied mainly to genomic sequencing and targeted re-sequencing. Here we demonstrate the utility of Ion Torrent semiconductor-based sequencing for sensitive, efficient and rapid chromatin immunoprecipitation followed by sequencing (ChIP-seq) through the application of sample preparation methods that are optimized for ChIP-seq on the Ion Torrent platform. We leverage this method for epigenetic profiling of tumour tissues.


Asunto(s)
Genoma Humano , Histonas/metabolismo , Melanoma/química , Procesamiento Proteico-Postraduccional , Análisis de Secuencia de ADN/instrumentación , Neoplasias Cutáneas/química , Animales , Cromatina/metabolismo , Inmunoprecipitación de Cromatina , Células Dendríticas/citología , Células Dendríticas/metabolismo , Epigénesis Genética , Femenino , Histonas/genética , Humanos , Melanoma/genética , Melanoma/metabolismo , Ratones , Ratones Endogámicos C57BL , Semiconductores , Análisis de Secuencia de ADN/métodos , Neoplasias Cutáneas/genética , Neoplasias Cutáneas/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...