Artículo en Inglés | MEDLINE | ID: mdl-38662577

RESUMEN

PURPOSE: To investigate the long-term astigmatism after combined non-penetrating glaucoma surgery (NPGS) and implantation of the first miniaturized suprachoroidal intraocular pressure (IOP) sensor EYEMATE-SC. SETTING: The study was conducted in five medical centers in two different countries. DESIGN: Retrospective multicenter clinical study. METHODS: Astigmatism of patients instrumented with the EYEMATE-SC IOP sensor was assessed over a follow-up period of three years. Refraction and corrected distance visual acuity (CDVA) were obtained preoperatively, after 6 months, 1, 2, and 3 years. A canaloplasty-operated patient cohort served as control. Astigmatism was evaluated using 3-dimensional power vector analysis involving the spherical equivalent M, and the Jackson crossed cylinder projections J0 and J45. Exclusion criteria included neovascular and angle-closure glaucoma, myopia, axial length outside 22 to 26 mm, other ocular diseases, prior glaucoma surgery, other ocular surgery within 6 months (cataract surgery within 3 months) prior to NPGS, serious generalized conditions, and other active medical head/neck implants. RESULTS: Multivariate analysis indicated no changes in astigmatism along the observation period in both the EYEMATE-SC (n = 24) and the canaloplasty (n = 24) group (P > 0.05 or nonsignificant after Bonferroni correction). Astigmatism was unchanged between the EYEMATE-SC and the canaloplasty group at all time points (P > 0.05). CDVA didn't change along the observation period of three years in each of both groups (P > 0.05). CONCLUSIONS: Despite its suprachoroidal localization, the present study indicates that the miniaturized EYEMATE-SC IOP sensor doesn't negatively affect the long-term astigmatism after combined implantation with NPGS.

2.
Am J Ophthalmol ; 260: 172-181, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38109951

RESUMEN

PURPOSE: To evaluate the performance and safety of minimally invasive glaucoma surgery with a supraciliary drainage device (MINIject; iSTAR Medical, Wavre, Belgium) in primary open-angle glaucoma (POAG) as a stand-alone procedure. DESIGN: Meta-analysis. METHODS: At 11 sites in Colombia, France, Germany, India, Panama, and Spain, 82 patients were treated in 3 prospective, multicenter, interventional, nonrandomized trials (STAR-I, II, III). Data were pooled in a meta-analysis of up to 2 years of follow-up postimplantation. The main outcome measures were mean relative and absolute reduction in diurnal intraocular pressure (IOP) compared to baseline. Secondary outcomes included patients with IOP ≤18 mmHg, patients with IOP reduction ≥20%, number of IOP-lowering medications, adverse events, and endothelial cell density loss. RESULTS: At the 2-year follow-up (n = 66), mean IOP was reduced from 23.8 ± 3.3 mmHg at baseline to 14.4 ± 4.5 mmHg (-39.3%; P < 0.0001). An IOP reduction of ≥20% was achieved in 89.4% of patients, with 84.8% having an IOP ≤18 mmHg. IOP-lowering medications were reduced from a mean of 2.4 ± 1.1 to 1.4 ± 1.4 (P < 0.0001), with 37.9% of patients being medication-free at 2 years. Mean endothelial cell density loss at 2 years was 6.2 ± 9.1% compared to baseline and no patient had a loss >30%. CONCLUSIONS: This meta-analysis demonstrates the favorable safety and efficacy profile of a supraciliary device implanted in a stand-alone, ab-interno procedure in patients with mild-to-moderate POAG. The data demonstrate that MINIject is a safe and effective, bleb-free treatment option for patients requiring low target IOP up to 2 years.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma de Ángulo Abierto , Humanos , Estudios Prospectivos , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Presión Intraocular , Tonometría Ocular , Resultado del Tratamiento , Estudios Multicéntricos como Asunto
3.
Artículo en Inglés | MEDLINE | ID: mdl-37673088

RESUMEN

PURPOSE: To compare two glaucoma drainage devices with subconjunctival filtration (MicroShunt and XEN) for open-angle glaucoma (OAG), with respect to effectiveness and safety. PATIENTS AND METHODS: This is a single center, retrospective, interventional study. In total, 106 eyes of 95 patients with OAG underwent surgery. Of these patients, 51 eyes of 45 patients received a MicroShunt implantation and 55 eyes of 50 patients received an XEN implantation. Failure was defined as an intraocular pressure (IOP) lower than 5 or higher than 17 mmHg at the end of follow-up after 2 years, the need for surgical revision, secondary glaucoma surgery, or loss of light perception. Outcome was rated as complete success or qualified success, depending on whether it was achieved with or without anti-glaucomatous medications. Postoperative complications and interventions were also documented for both groups. RESULTS: In the MicroShunt group, mean IOP decreased from 20.6 ± 7.5 mmHg at baseline to 13.0 ± 3.9 mmHg (p < 0.0001) after 2 years. In the XEN group, mean IOP was lowered from 22.5 ± 7.9 mmHg to 13.5 ± 4.2 mmHg (p < 0.0001). In both groups, the mean number of medications was significantly reduced (MicroShunt 2.7 ± 1.2 to 0.9 ± 2.5; p < 0.0001 vs. XEN 3.2 ± 0.9 to 1.1 ± 1.5; p < 0.0001). In regard to success rates, 37% of MicroShunt patients achieved complete success and 57% qualified success at the end of follow-up. In the XEN group, rates were 25 and 45%, respectively. Patient demographics differed between the two groups with respect to age (MicroShunt 72.8 ± 8.7 vs. XEN 67.7 ± 9.0 years; p = 0.002). Postoperative complications were comparable between the two groups. CONCLUSION: Both MicroShunt and XEN are effective in significantly reducing IOP and glaucoma medications in OAG, and with a good safety profile.

4.
Int Ophthalmol ; 43(11): 4067-4078, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37658170

RESUMEN

PURPOSE: To evaluate the impact of the iridocorneal angle size (ICAS) on the diurnal intraocular pressure (IOP) in patients with suspected glaucoma (SG). METHOD: Patients with any eye-pressure lowering medication or previous ocular surgery were excluded. In a retrospective study set, diurnal IOP profiles of 120 patients (205 eyes) within a 48-h period were analysed by regression analysis. Of those eyes, 44 were diagnosed to have glaucoma. The remaining eyes were used as healthy control group (HCG). RESULTS: The overall mean IOP was 15.63 mmHg ± 2.72 mmHg and mean ICAS was 23.92° ± 4.74°. In the glaucoma cohort, mean IOP was 18.77 ± 1.86 mmHg and mean ICAS was 25.02° ± 4.96°. In the HCG, mean IOP was 14.77 ± 2.25 mmHg and mean ICAS was 23.62° ± 4.64°. In the total cohort, as well as in the subgroups (HCG or glaucoma), regression analysis showed no significant impact even of the minimum ICAS, which was larger than 10°, on average (P = 0.89), maximum (P = 0.88), and range of IOP (P = 0.49) within 48 h. The difference between glaucoma cohort and HCG cohort was significant in terms of IOP (P < 0.001), but not for minimum ICAS (P = 0.07). Chi-square test showed no increase in prevalence of IOP peaks of  > 21 mmHg within 48 h in eyes with an angle between 10° and 20° (P = 0.18). CONCLUSION: An ICAS of larger than 10° in HCG or glaucoma patients with an open-angle does not influence the minimum, average, maximum or range of IOP. Additionally, an angle size larger than 10° does not allow the prediction of IOP changes in these two cohorts.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Hipertensión Ocular , Humanos , Estudios Retrospectivos , Glaucoma de Ángulo Abierto/cirugía , Glaucoma/diagnóstico , Hipertensión Ocular/diagnóstico , Presión Intraocular , Tonometría Ocular
5.
J Clin Med ; 12(8)2023 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-37109334

RESUMEN

This retrospective, single-center study evaluates the safety and efficacy of PreserfloTM MicroShunt (MicroShunt) implantations compared to trabeculectomies (TETs) in patients diagnosed with pseudoexfoliation glaucoma (PEXG). A total of 31 eyes from 28 patients received a MicroShunt implantation, and 29 eyes from 26 patients received a TET. Surgical success was defined as an intraocular pressure (IOP) between 5 mmHg and 17 mmHg at the end of the follow-up period, no need for surgical revisions or secondary glaucoma surgery, and no loss of light perception. In the MicroShunt group, the mean IOP dropped from 20.8 ± 5.9 mmHg at baseline to 12.4 ± 2.8 mmHg (p < 0.0001) after one year. In the TET group, the mean IOP dropped from 22.3 ± 6.5 mmHg to 11.1 ± 3.7 mmHg (p < 0.0001) after 12 months. In both of the groups, the mean number of medications was reduced significantly (MicroShunt from 2.7 ± 1.2 to 0.2 ± 0.7; p < 0.0001 vs. TET from 2.9 ± 1.2 to 0.3 ± 0.9; p < 0.0001). Considering the success rates, 83.9% of the MicroShunt eyes achieved complete success, and 90.3% qualified for success at the end of the follow-up period. In the TET group, the rates were 82.8% and 93.1%, respectively. The postoperative complications were comparable between both groups. In conclusion, the MicroShunt implantation demonstrated non-inferiority regarding its efficacy and safety profile compared to TET in PEXG at a follow-up of one year.

6.
Br J Ophthalmol ; 107(4): 518-524, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-34772665

RESUMEN

AIM: To investigate the safety and performance of a telemetric suprachoroidal intraocular pressure (IOP) sensor (EYEMATE-SC) and the accuracy of its IOP measurements in open angle glaucoma (OAG) patients undergoing simultaneous non-penetrating glaucoma surgery (NPGS). METHODS: Prospective, multicentre, open-label, single-arm, interventional clinical trial. Twenty-four eyes of 24 patients with OAG regularly scheduled for NPGS (canaloplasty or deep sclerectomy) were simultaneously implanted with an EYEMATE-SC sensor. Six-month follow-up on the sensor's safety and performance as well as on the level of agreement between the EYEMATE-SC measurements and IOP measurements with Goldmann applanation tonometry (GAT). RESULTS: The eyes underwent canaloplasty (n=15) or deep sclerectomy (n=9) and achieved successful implantation of the sensor. No device migration, dislocation or serious device-related complications occurred. A total of 367 comparisons were included in the IOP agreement analysis. The overall mean difference between GAT and EYEMATE-SC measurements was 1.31 mm Hg (lower limit of agreement (LoA) 7.55 mm Hg; upper LoA -4.92 mm Hg). The maximum difference of 2.5 mm Hg ±3.96 (LoA 0.30-2.29) was reached on day 10 and continuously improved to an agreement of -0.15 mm Hg ±2.28 (LoA -1.24 to 0.89) after 6 months. Accordingly, the percentage of eyes within an IOP difference of ±5 mm Hg improved from 78% (day 3) to 100% (6 months). CONCLUSIONS: After 6 months, the EYEMATE-SC sensor was safe and well tolerated, and allowed continual IOP monitoring. TRIAL REGISTRATION NUMBER: NCT03756662.


Asunto(s)
Glaucoma de Ángulo Abierto , Presión Intraocular , Humanos , Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Ángulo Abierto/cirugía , Estudios Prospectivos , Tonometría Ocular
7.
Ophthalmology ; 130(3): 304-312, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36202141

RESUMEN

PURPOSE: Measuring and controlling intraocular pressure (IOP) provide the foundation for glaucoma treatment. Self-tonometry has been proposed as an alternative to measure IOP throughout the entire day better. The novel EYEMATE-SC sensor (Implandata) is implanted in the suprachoroidal space to enable contactless continual IOP monitoring. The aim of the present study was to investigate the 1-year safety, performance, and accuracy of the EYEMATE-SC in patients with primary open-angle glaucoma undergoing simultaneous nonpenetrating glaucoma surgery (NPGS). DESIGN: Prospective, multicenter, open-label, single-arm, interventional clinical trial. PARTICIPANTS: Twenty-four eyes of 24 patients with primary open-angle glaucoma who were due to undergo NPGS (canaloplasty or deep sclerectomy). METHODS: An EYEMATE-SC sensor was implanted during NPGS. Goldmann applanation tonometry (GAT) measurements were compared with the sensors' IOP measurements at all postoperative visits through 12 months. MAIN OUTCOME MEASURES: Device position and adverse events. RESULTS: Fifteen eyes underwent canaloplasty, and 9 underwent deep sclerectomy. Successful implantation of the sensor was achieved in all eyes with no reported intraoperative difficulties. Through the 12-month follow-up, no device migration, dislocation, or serious device-related complications were recorded. A total of 536 EYEMATE-SC measurements were pairwise included in the IOP agreement analysis. The overall mean difference between GAT and EYEMATE-SC measurements was 0.8 mmHg (95% confidence interval [CI] of the limits of agreement [LoA], -5.1 to 6.7 mmHg). The agreement gradually improved, and from 3 months after surgery until the end of the follow-up, the mean difference was -0.2 mmHg (95% CI of LoA, -4.6 to 4.2 mmHg) over a total of 264 EYEMATE-SC measurements, and 100% of measurements were within ±5 mmHg of GAT. CONCLUSIONS: The EYEMATE-SC sensor was safe and well tolerated through 12 months. Moreover, it allowed accurate, continuous IOP monitoring. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Asunto(s)
Glaucoma de Ángulo Abierto , Presión Intraocular , Humanos , Estudios Prospectivos , Reproducibilidad de los Resultados , Tonometría Ocular
8.
Life (Basel) ; 12(8)2022 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-36013458

RESUMEN

Background: Treatment of non-arteritic central retinal artery occlusion is still inconsistent. Therefore, the current study aimed to evaluate the efficacy of intravenous thrombolysis (IVT) and describe the prevalence of co-occurring ischemic brain lesions in patients with acute visual loss due to ischemia. Methods: We analysed 38 consecutive patients with acute visual loss between January 2015 and June 2020. Patients presenting within 4.5 h of symptom onset without any contraindication were treated with IVT. Patients underwent neurologic and ophthalmologic examination and diagnostic workup for the underlying aetiology. Follow-up was performed after 3 and 12 months. Results: Patients treated with IVT had a significantly better functional outcome at discharge compared to patients treated conservatively. No additional ischemic brain lesions were detected (0 of 38). Three patients had extracranial carotid artery stenosis ≥50%. Atrial fibrillation was present in four patients, three of whom already received oral anticoagulation. In the remaining 31 patients no embolic source was detected. However, the number of plaques were rated mild to moderate. Within three months, one patient developed transient visual loss while another suffered a contralateral transient ischemic attack. Conclusions: IVT may represent a safe and effective treatment option in patients with isolated visual loss due to ischemia. The aetiology was atherosclerotic burden rather than embolism caused by carotid stenosis or atrial fibrillation, bringing the current diagnostic procedure and therapy into question. Randomized trials are necessary to evaluate the efficacy and safety of IV thrombolysis and clarify the aetiology of isolated visual loss due to ischemia.

9.
RMD Open ; 7(3)2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34544823

RESUMEN

OBJECTIVE: To determine the association of arteriosclerosis, characterised by hyperechogenic intimal lesions (HIL), with wall thickness of the temporal and facial arteries in elderly patients with ocular arterial occlusions. METHODS: Patients suffering from non-arteritic ocular perfusion disorders were included. High-resolution compression sonography (18 MHz) images of the temporal arteries (frontal and parietal branch at the upper margin of the auricle) and facial arteries (at the crossing point of the artery over the mandible) were analysed for the presence of HIL (grade 0: absent; grade 1: moderate; grade 2: severe). Characteristics of patients with and without evidence of HIL >grade 1 were compared. RESULTS: In total, 330 cranial artery segments of 55 patients were analysed. HIL ≥grade 1 was present in 13.0% of all artery segments and in 38.1% of all patients. Patients with HIL ≥grade 1 in at least one arterial segment displayed significantly increased maximum wall thickness of the temporal arteries (0.62±0.23 mm vs 0.50±0.13 mm; p<0.01) and facial arteries (0.71±0.20 mm vs 0.54±0.19 mm; p=0.01). Patients with at least one temporal or facial artery segment with HIL were older, more often male and more frequently suffered from diabetes mellitus. CONCLUSION: The presence of HIL goes along with a significantly increased wall thickness of the temporal and facial arteries. These findings should be considered when interpreting the results of sonography of the cranial arteries in the diagnostic workup of suspected giant cell arteritis.


Asunto(s)
Arteritis de Células Gigantes , Arterias Temporales , Anciano , Arterias/diagnóstico por imagen , Arteritis de Células Gigantes/diagnóstico por imagen , Humanos , Masculino , Arterias Temporales/diagnóstico por imagen , Ultrasonografía
11.
PLoS One ; 16(8): e0256670, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34449795

RESUMEN

PURPOSE: To compare the safety and efficacy of microshunt implantation augmented with Mitomycin C in patients with pseudoexfoliation glaucoma (PEXG) and primary open-angle glaucoma (POAG). METHODS: In this retrospective, single centre, interventional study, 46 eyes of 41 patients with PEXG (20 eyes) and POAG (26 eyes) underwent microshunt implantation. Definition of failure was an intraocular pressure (IOP) lower than 5 or higher than 17mmHg on two consecutive visits, an IOP reduction lower than 20% on two consecutive visits, the need of surgical revisions or reoperations or loss of light perception. Outcome was rated as complete success if achieved without medication, otherwise as qualified success. Furthermore, postoperative complications and interventions were compared between the two groups. RESULTS: Patient demographics were similar, except for older age in the PEXG group (70.9±8.6 versus 77.6±8; p = 0.02). Mean IOP dropped from 21.5±5.8mmHg (PEXG) and 18.2±4.5mmHg (POAG) at baseline to 12.8±3.0mmHg (p<0.0001) and 12.9±4.2mmHg (p<0.0001), respectively, at one year. Mean number of medications were reduced from 2.8±1.3 to 0.3±0.8 for PEXG patients (p<0.0001) and from 2.7±1.3 to 0.3±0.8 for POAG patients (p<0.0001). At one year of follow-up 75.0% of PEXG patients achieved complete success and 80.0% qualified success. In the POAG group rates were 73.1% and 76.9%, respectively. Postoperative complications were comparable between both groups, except for higher rates of hypotony (p = 0.04) and choroidal detachment (p = 0.03) in the PEXG group. CONCLUSION: Microshunt implantation demonstrated similar efficacy results in PEXG and POAG eyes at a follow-up of 12 months. Higher rates of transient hypotony and choroidal detachment were observed in PEXG eyes.


Asunto(s)
Síndrome de Exfoliación/cirugía , Implantes de Drenaje de Glaucoma/efectos adversos , Glaucoma de Ángulo Abierto/cirugía , Complicaciones Posoperatorias/cirugía , Anciano , Anciano de 80 o más Años , Córnea/diagnóstico por imagen , Córnea/cirugía , Síndrome de Exfoliación/diagnóstico por imagen , Síndrome de Exfoliación/fisiopatología , Femenino , Glaucoma de Ángulo Abierto/diagnóstico por imagen , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/fisiopatología , Tonometría Ocular , Trabeculectomía/métodos , Resultado del Tratamiento
13.
J Refract Surg ; 37(5): 312-317, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-34044696

RESUMEN

PURPOSE: To compare different new-generation biometric formulas and ray-tracing for small-aperture intraocular lens (IOL) (IC-8; Acufocus, Inc) implantation in patients undergoing cataract and refractive lens exchange surgery with highly irregular corneas. METHODS: This monocenter study included 17 eyes of 17 patients with highly irregular corneas of different genesis. Biometric and topographic corneal data were assessed using the IOLMaster 700 (Carl Zeiss Meditec) and Pentacam (Oculus Optkigeräte GmbH). Prediction and absolute error were compared after 3 months based on manifest refraction. Furthermore, change of total corneal refractive power in different corneal pathologies was also evaluated. For IOL power calculation, three fourth-generation IOL formulas were compared (Haigis, SRK-T, and Barrett Universal II). The dataset was then checked against ray-tracing and analyzed to improve prediction error in these highly irregular corneas. RESULTS: All patients showed an improvement in visual acuity postoperatively with a mean spherical equivalent of -1.22 ± 0.49 diopters (D). Overall comparison of the three formulas showed the Haigis formula to be superior in terms of the smallest deviation of predictive and absolute error. IOL calculations with ray-tracing were possible in all eyes, but showed inaccurate results with keratometric values of 48.00 D and greater. CONCLUSIONS: The IC-8 IOL is well suited for patients with lens exchange in highly irregular corneas. The Haigis formula seemed to be the most accurate in the patient group. Ray-tracing confirmed the results of biometric formulas up to a keratometric value of 48.00 D and should be compared with standard biometric formulas to address corneal irregularities and to minimize refractive surprises after surgery. A comparison with ray-tracing in eyes with a keratometric value of greater than 48.00 D should not be considered due to the inaccurate results. [J Refract Surg. 2021;37(5):312-317.].


Asunto(s)
Astigmatismo , Lentes Intraoculares , Facoemulsificación , Astigmatismo/cirugía , Biometría , Córnea , Humanos , Implantación de Lentes Intraoculares , Óptica y Fotónica , Refracción Ocular , Estudios Retrospectivos
14.
J Clin Med ; 10(6)2021 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-33802092

RESUMEN

BACKGROUND: Risk stratification based on pre-test probability may improve the diagnostic accuracy of temporal artery high-resolution compression sonography (hrTCS) in the diagnostic workup of cranial giant cell arteritis (cGCA). METHODS: A logistic regression model with candidate items was derived from a cohort of patients with suspected cGCA (n = 87). The diagnostic accuracy of the model was tested in the derivation cohort and in an independent validation cohort (n = 114) by receiver operator characteristics (ROC) analysis. The clinical items were composed of a clinical prediction rule, integrated into a stepwise diagnostic algorithm together with C-reactive protein (CRP) values and hrTCS values. RESULTS: The model consisted of four clinical variables (age > 70, headache, jaw claudication, and anterior ischemic optic neuropathy). The diagnostic accuracy of the model for discrimination of patients with and without a final clinical diagnosis of cGCA was excellent in both cohorts (area under the curve (AUC) 0.96 and AUC 0.92, respectively). The diagnostic algorithm improved the positive predictive value of hrCTS substantially. Within the algorithm, 32.8% of patients (derivation cohort) and 49.1% (validation cohort) would not have been tested by hrTCS. None of these patients had a final diagnosis of cGCA. CONCLUSION: A diagnostic algorithm based on a clinical prediction rule improves the diagnostic accuracy of hrTCS.

15.
Artículo en Alemán | MEDLINE | ID: mdl-33873208

RESUMEN

Pigment dispersion syndrome (PDS) is a disorder predominantly affecting young, myopic adults. It is characterised by the liberation of pigment of the iris and deposition of it on various structures of the anterior segment leading to multiple specific findings in slit lamp examination. Typical alterations are a deposition of pigment on the central corneal endothelium, circular iris transillumination defects in the mid periphery, a posterior bowing of the iris and increased pigmentation of the trabecular meshwork. Findings are usually bilateral symmetric. Posterior bowing of the iris causes rubbing of the pigmented iris epithelium against lens structures like zonular fibres with a consecutive liberation of pigment. Trabecular meshwork changes because of pigment deposition reduce aqueous outflow facility with the risk of elevated intraocular pressure and glaucoma. Pigmentary glaucoma (PG) is a secondary open angle glaucoma. Treatment of PG is similar to primary open angle glaucoma, including medical therapy, laser therapy and surgery. Peripheral laser iridotomy was shown to change iris configuration but its efficacy in the prevention of PG has not been confirmed in the literature. The purpose of this paper is to summarize information regarding ocular manifestations of PDS to facilitate an early diagnosis and to present a general view of the treatment of PG.

16.
BMJ Open Ophthalmol ; 6(1): e000589, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33634210

RESUMEN

OBJECTIVE: Intraocular lens (IOL) opacification may cause severe visual impairment. The pathogenesis remains unclear. The aim of this study was to analyse opacification patterns in different IOLs. Therefore, this multicentre, retrospective, observational study was conducted at Ludwig-Maximilians-University, Munich, Germany and University-Hospital Basel, Switzerland. METHODS AND ANALYSIS: In this study, 75 opacified IOLs were identified and classified after extraction. Macroscopical photo documentation, light and electron microscopic analysis were done. RESULTS: 68 acrylic-hydrophilic single-piece-IOLs, 1 acrylic-hydrophilic 3-piece-IOL, 6 acrylic-hydrophobic 3-piece-IOLs were extracted. The dataset comprised IOLs known for opacification and IOLs not having been reported yet. 67 IOLs showed a fine-granular and 8 IOLs a crust-like opacification pattern. According to literature, 62 of the fine-granular opacified IOLs were graded into type 1 (processing/packaging-induced primary opacification) and 13 into type 2 (secondary opacification of unknown aetiology). The anterior surface of the IOLs was affected in all 75 IOLs, the posterior surface only in 23 cases. Of all 67 fine-granular IOLs, 43 had a central defect and 21 had a zone without opacification (clear islet). CONCLUSION: In our series, the morphology of IOL opacification did not follow the existing pathogenetic classification that strictly discriminates between primary and secondary causes. Fine-granular IOL opacification occurs with similar patterns in both type 1 and type 2 IOL opacification, while a crust-like pattern was only detected in type 2 IOL opacifications. Consequently, susceptibility of an IOL to opacification is caused by a multifactorial combination of material and processing properties as well as individual (pathological) conditions of the patient.

17.
PLoS One ; 16(2): e0247072, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33577572

RESUMEN

PURPOSE: To characterize the diagnostic yield of the spot sign in the diagnostic workup of acute arterial occlusions of the eye in elderly patients. METHODS: Clinical characteristics of consecutive patients aged ≥ 50 years with acute central retinal artery occlusion (CRAO), branch retinal artery occlusion (BRAO) or anterior ischemic optic neuropathy (AION) were recorded. Videos of transocular sonography were assessed for the presence of the spot sign by two blinded readers. Group comparisons were made between CRAO-patients with and without the spot sign. Two experienced cardiovascular physicians allocated CRAO-cases to a presumed aetiology, without and with knowledge on the presence/absence of the spot sign. RESULTS: One-hundred-twenty-three patients were included, 46 of whom suffered from CRAO. A spot sign was seen in 32 of 46 of patients with CRAO and in 7 of 23 patients with BRAO. Interobserver agreement was excellent (Cohen`s kappa 0.98). CRAO-patients with the spot sign significantly more frequently had a medical history of cardiovascular disease (62.8 vs. 21.4%, p = 0.03) and left heart valve pathologies (51.9 vs. 10%, p = 0.03). The spot sign was not found in any of the three patients with CRAO secondary to cranial giant cell arteritis. The assumed CRAO aetiology differed in 37% of cases between two cardiovascular physicians, regardless whether transocular sonography findings were known or not. CONCLUSION: The spot sign is a simple sonographic finding with excellent interobserver agreement, which proofs the embolic nature of CRAO, but does not allow exact attribution of the underlying aetiology.


Asunto(s)
Enfermedades del Nervio Óptico/diagnóstico por imagen , Oclusión de la Arteria Retiniana/diagnóstico por imagen , Ultrasonografía/normas , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Ultrasonografía/métodos
19.
Ophthalmologe ; 118(7): 724-727, 2021 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-32681299

RESUMEN

A visual deterioration due to opacification of the intraocular lens was observed 3 weeks after uncomplicated combined minimally invasive glaucoma and cataract surgery. Due to the patient's failure to apply the prescribed postoperative local anti-inflammatory eyedrops, homogeneous fibrin coating on the anterior surface of the lens occurred, as well as early scarring of the filtering bleb. We performed needling with 5­fluorouracil and lens polishing with the Nd:YAG laser to achieve sufficient pressure control and vision improvement.


Asunto(s)
Extracción de Catarata , Catarata , Glaucoma , Terapia por Láser , Lentes Intraoculares , Glaucoma/cirugía , Humanos , Complicaciones Posoperatorias/etiología
20.
J Neuroophthalmol ; 41(1): e105-e106, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-32282511

RESUMEN

ABSTRACT: A 78-year-old man suffered sudden visual loss of his right eye. Five years earlier, he had experienced vision loss of his left eye due to central retinal artery occlusion (CRAO); back then, the etiology for the CRAO was not established. Current ocular ultrasound depicted a hyperechoic spot within the optic nerve in both eyes. Echocardiography identified a calcified mass adherent to the mitral valve as the embolic source of the CRAO. This case shows the value of ocular B-mode ultrasound in demonstration and proof of the etiology for CRAO.


Asunto(s)
Embolia/diagnóstico por imagen , Nervio Óptico/diagnóstico por imagen , Oclusión de la Arteria Retiniana/diagnóstico por imagen , Anciano , Humanos , Masculino , Ultrasonografía