Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Acta Physiol (Oxf) ; 213(3): 653-63, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25515791

RESUMEN

AIM: Mild hypothermia (MH) decreases left ventricular (LV) end-diastolic capacitance. We sought to clarify whether this results from incomplete relaxation. METHODS: Ten anaesthetized pigs were cooled from normothermia (NT, 38 °C) to MH (33 °C). LV end-diastolic pressure (LVPed), volume (LVVed) and pressure-volume relationships (EDPVRs) were determined during stepwise right atrial pacing. LV capacitance (i.e. LVVed at LVPed of 10 mmHg, LV VPed10) was derived from the EDPVR. Pacing-induced changes of diastolic indices (LVPed, LVVed and LV VPed10) were analysed as a function of (i) heart rate and (ii) the ratio between diastolic time interval (t-dia) and LV isovolumic relaxation constant τ, which was calculated using a logistic fit (τL ) and monoexponential fit with zero asymptote (τZ ) and nonzero asymptote (τNZ ). RESULTS: Mild hypothermia decreased heart rate (85 ± 4 to 68 ± 3 bpm), increased τL (22 ± 1 to 57 ± 4 ms), τZ (26 ± 2 to 56 ± 5 ms) and τNZ (41 ± 1 to 96 ± 5 ms), decreased t-dia/τ ratios, and shifted the EDPVR leftwards compared to NT (all P < 0.05). During NT, pacing at ≥140 bpm shifted the EDPVR progressively leftwards. During MH, relationships between diastolic indices and heart rate were shifted towards lower heart rates compared to NT. However, relationships between diastolic indices and t-dia/τ during NT and MH were superimposable. CONCLUSION: We conclude that the loss of LV end-diastolic capacitance during MH can be explained at least in part by slowed LV relaxation. MH thereby is an example of incomplete LV relaxation at a spontaneous low heart rate. Caution may be advised, when heart rate is increased in patients treated with MH.


Asunto(s)
Bradicardia/etiología , Diástole , Frecuencia Cardíaca , Hipotermia Inducida/efectos adversos , Disfunción Ventricular Izquierda/etiología , Función Ventricular Izquierda , Animales , Bradicardia/diagnóstico , Bradicardia/fisiopatología , Estimulación Cardíaca Artificial , Volumen Sistólico , Porcinos , Factores de Tiempo , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/fisiopatología , Presión Ventricular
2.
Acta Physiol (Oxf) ; 203(4): 409-18, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21658179

RESUMEN

AIM: Mild hypothermia (MH) after cardiac arrest attenuates hypoxic brain injury and improves survival. As MH increases contractility in normal hearts, we hypothesized that MH improves cardiovascular function after cardiac arrest. METHODS: In 16 anaesthetized pigs (64 ± 2 kg), ventricular fibrillation was induced electrically for 5 min. At 10 min after resuscitation and return of spontaneous circulation (ROSC), pigs were assigned to normothermia (NT, 38°C, n = 8) or MH (33°C, n = 8, intravascular cooling). RESULTS: At ROSC 6 h vs. baseline, heart rate (HR) was unchanged in NT, but decreased in MH. Cardiac output (CO, l min(-1)) decreased in MH (3.5 ± 0.2 vs. 5.5 ± 0.4, P < 0.05) more than in NT (4.8 ± 0.4 vs. 5.7 ± 0.4, P = ns). Mixed venous oxygen saturation decreased in NT (56 ± 2 vs. 66 ± 3%, P < 0.05), but remained constant in MH (64 ± 2 vs. 65 ± 2%) due to a 35% decrease of whole body oxygen consumption. Left ventricular (LV) dP/dt(max) (mmHg s(-1)) decreased in NT (1163 ± 97 vs. 1665 ± 134, P < 0.05), but was preserved in MH (1602 ± 102 vs. 1603 ± 96), whereas LV relaxation was profoundly slowed during MH. Pressure-volume analysis confirmed improved LV systolic function during MH, but also demonstrated decreased LV end-diastolic distensibility, which was further potentiated by right atrial pacing at baseline HR. MH did not increase plasma catecholamine levels. Spectral analysis of heart rate variability revealed reduced sympathetic activation during MH. CONCLUSION: The induction of MH after cardiac resuscitation improves systolic myocardial function without further sympathetic activation. A reduced metabolism during MH outweighs a decreased CO and thereby acts favourably on systemic oxygen supply/demand balance.


Asunto(s)
Paro Cardíaco/terapia , Hipotermia Inducida , Animales , Gasto Cardíaco , Volumen Cardíaco , Catecolaminas/sangre , Diástole , Femenino , Paro Cardíaco/sangre , Frecuencia Cardíaca , Consumo de Oxígeno , Porcinos , Sístole
3.
Thorac Cardiovasc Surg ; 51(4): 204-10, 2003 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-14502457

RESUMEN

BACKGROUND: The identification of the ideal anastomosis site and the proper port placement are critical for the success of closed-chest robotic surgery. We investigated a new systematic procedure for precise port placement for TECABs. METHODS: We used trigonometry and a human thoracic model to determine the optimal working angles between anastomotic plane, instruments, and endoscope. We then applied the results to seven human subjects as follows: 1. A navigation grid was located extrathoracically before cardiac MR examination. 2. The ideal anastomosis site was defined with the MR. Intrathoracic distances and angles were computed with cardiac MR software and projected onto the thorax. 3. The ideal port placement points were marked on the thorax. RESULTS: The optimal working angle between endoscope and instruments was 35 degrees. 0 degrees and 90 degrees angles were associated with a significant reduction in visualization, technical ease, quality and anastomosis time. The course of the LAD was identified in all seven volunteers with MR. Mean deviation of the endoscope port from the medioclavicular line was 4.3+/-2.1 cm and of the instrument ports from the anterior axillary line 8.4+/-2.4 cm. CONCLUSIONS: Cardiac MR in combination with the navigation grid proved suitable for the visualization of coronary vessels for individually calculating port placement points on the thorax.


Asunto(s)
Puente de Arteria Coronaria , Vasos Coronarios/anatomía & histología , Endoscopía , Corazón/anatomía & histología , Imagen por Resonancia Magnética , Robótica , Adulto , Simulación por Computador , Humanos , Imagenología Tridimensional , Masculino , Modelos Estructurales , Fantasmas de Imagen
4.
Anesth Analg ; 84(3): 484-90, 1997 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-9052287

RESUMEN

Atrial electrical activities during hypothermic, K(+)-induced cardioplegic arrest correlate with an increased incidence of postoperative supraventricular dysrhythmias in coronary artery bypass graft patients. Surface electrocardiogram (ECG) (S-ECG) may be insufficiently sensitive to detect such activity intraoperatively, and invasive methods are impractical and traumatic. From induction of anesthesia until the end of surgery, esophageal ECG signals were detected with a new bipolar esophageal probe and a new high-resolution preamplifier (frequency range 0.01-2000 Hz). The S-ECG and the esophageal ECG (E-ECG) were evaluated independently in 18 patients. Eight of 18 patients presented during cardioplegic arrest a mean of 483 +/- 119 high-amplitude, biphasic P components (mean amplitude 0.7 +/- 0.1 mV, range 0.35-1.15 mV) per patient (mean 36 +/- 6 [5-59] potentials/min) similar to those coinciding with the surface ECG P-waves during sinus rhythm. Six of these eight patients presented a mean of 29 +/- 11 low atrial activities (mean amplitude 0.14 +/- 0.023 mV; range 0.1-0.25 mV) per patient (mean 8.4 +/- 5.6 [2.3-48] potentials/min) in the E-ECG. In the S-ECG, one patient of these eight presented 26 P waves during cardioplegic arrest simultaneously with activities in the E-ECG. During the first 5 days, seven of eight (88%) patients with atrial activities in the E-ECG versus 3 of 10 (30%) patients without atrial activities developed supraventricular tachyarrhythmias postoperatively (P < 0.05). This new high-resolution E-ECG device detected in a beat-to-beat technique more atrial activity during cardioplegic arrest than a S-ECG and offered the advantages of artifact exclusion and better prediction of postoperative supraventricular dysrhythmias.


Asunto(s)
Función Atrial , Electrocardiografía/métodos , Paro Cardíaco , Anciano , Frío , Electrofisiología , Esófago , Femenino , Sistema de Conducción Cardíaco/fisiología , Humanos , Masculino , Persona de Mediana Edad , Potasio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA