Resultados 1 - 20 de 39
Filtrar
1.
Heart Rhythm ; 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38493989

RESUMEN

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.

2.
Front Cardiovasc Med ; 10: 1169037, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37476572

RESUMEN

Background: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have the potential to act as a reliable predictor of the durability of the lesions created. Objective: We aimed to collect data on the procedural parameters affecting LI-guided ablation in a large multicenter registry. Methods: A total of 212 consecutive patients enrolled in the CHARISMA registry and undergoing their first pulmonary vein (PV) isolation for paroxysmal and persistent AF were included. Results: In all, 13,891 radiofrequency (RF) applications of ≥3 s duration were assessed. The first-pass PV isolation rate was 93.3%. A total of 80 PV gaps were detected. At successful ablation spots, baseline LI and absolute LI drop were larger than at PV gap spots (161.4 ± 19â€…Ω vs. 153.0 ± 13 Ω, p < 0.0001 for baseline LI; 22.1 ± 9â€…Ω vs. 14.4 ± 5 Ω, p < 0.0001 for LI drop). On the basis of Receiver operating characteristic curve analysis, the ideal LI drop, which predicted successful ablation, was >21â€…Ω at anterior sites and >18â€…Ω at posterior sites. There was a non-linear association between the magnitude of LI drop and contact-force (CF) (r = 0.14, 95% CI: 0.13-0.16, p < 0.0001) whereas both CF and LI drop were inversely related with delivery time (DT) (-0.22, -0.23 to -0.20, p < 0.0001 for CF; -0.27, -0.29 to -0.26, p < 0.0001 for LI drop). Conclusion: An LI drop >21â€…Ω at anterior sites and >18â€…Ω at posterior sites predicts successful ablation. A higher CF was associated with an increased likelihood of ideal LI drop. The combination of good CF and adequate LI drop allows a significant reduction in RF DT. Clinical trial registration: http://clinicaltrials.gov/, identifier: NCT03793998.

3.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37038759

RESUMEN

AIMS: To allow timely initiation of anticoagulation therapy for the prevention of stroke, the European guidelines on atrial fibrillation (AF) recommend remote monitoring (RM) of device-detected atrial high-rate episodes (AHREs) and progression of arrhythmia duration along pre-specified strata (6 min…<1 h, 1 h…<24 h, ≥ 24 h). We used the MATRIX registry data to assess the capability of a single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (DX ICD system) to follow this recommendation in patients with standard indication for single-chamber ICD. METHODS AND RESULTS: In 1841 DX ICD patients with daily automatic RM transmissions, electrograms of first device-detected AHREs per patient in each duration stratum were adjudicated, and the corresponding positive predictive values (PPVs) for the detections to be true atrial arrhythmia were calculated. Moreover, the incidence and progression of new-onset AF was assessed in 1451 patients with no AF history. A total of 610 AHREs ≥6 min were adjudicated. The PPV was 95.1% (271 of 285) for episodes 6min…<1 h, 99.6% (253/254) for episodes 1 h…<24 h, 100% (71/71) for episodes ≥24 h, or 97.5% for all episodes (595/610). The incidence of new-onset AF was 8.2% (119/1451), and in 31.1% of them (37/119), new-onset AF progressed to a higher duration stratum. Nearly 80% of new-onset AF patients had high CHA2DS2-VASc stroke risk, and 70% were not on anticoagulation therapy. Age was the only significant predictor of new-onset AF. CONCLUSION: A 99.7% detection accuracy for AHRE ≥1 h in patients with DX ICD systems in combination with daily RM allows a reliable guideline-recommended screening for subclinical AF and monitoring of AF-duration progression.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/epidemiología , Desfibriladores Implantables/efectos adversos , Atrios Cardíacos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Anticoagulantes
4.
J Interv Card Electrophysiol ; 66(7): 1749-1757, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36869990

RESUMEN

BACKGROUND: A novel ablation catheter has been released to map and ablate the cavo-tricuspid isthmus (CTI) in patients with atrial flutter (AFL), improving ablation efficiency. METHODS: We evaluated the acute and long-term outcome of CTI ablation aiming at bidirectional conduction block (BDB) in a prospective, multicenter cohort study enrolling 500 patients indicated for typical AFL ablation. Patients were grouped on the basis of the AFL ablation method (linear anatomical approach, Conv group n = 425, or maximum voltage guided, MVG group, n = 75) and ablation catheter (mini-electrodes technology, MiFi group, n = 254, or a standard 8-mm ablation catheter, BLZ group, n = 246). RESULTS: Complete BDB according to both validation criteria (sequential detailed activation mapping or mapping only the ablation site) was achieved in 443 patients (88.6%). The number of RF applications needed to achieve BDB was lower in the MiFi MVG group vs both the MiFi Conv group and the BLZ Conv group (3.2 ± 2 vs 5.2 ± 4 vs 9.3 ± 5, p < 0.0001 for all comparisons). Fluoroscopy time was similar among groups, whereas we observed a reduction in the procedure duration from the BLZ Conv group (61.9 ± 26min) to the MiFi MVG group (50.6 ± 17min, p = 0.048). During a mean follow-up of 548 ± 304 days, 32 (6.2%) patients suffered an AFL recurrence. No differences were found according to BDB achieved by both validation criteria. CONCLUSIONS: Ablation was highly effective in achieving acute CTI BDB and long-term arrhythmia freedom irrespective of the ablation strategy or the validation criteria for CTI chosen by the operator. The use of an ablation catheter equipped with mini-electrodes technology seems to improve ablation efficiency. CLINICAL TRIAL REGISTRATION: Atrial Flutter Ablation in a Real World Population. (LEONARDO). CLINICALTRIALS: gov Identifier: NCT02591875.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Humanos , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Estudios de Cohortes , Estudios Multicéntricos como Asunto , Estudios Prospectivos , Resultado del Tratamiento , Estudios Clínicos como Asunto
5.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36709469

RESUMEN

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Asunto(s)
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedancia Eléctrica , Estudios Retrospectivos , Fibrilación Ventricular , Desfibriladores Implantables
6.
JACC Clin Electrophysiol ; 8(12): 1553-1562, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36543505

RESUMEN

BACKGROUND: Causes of sex differences in incidence of sustained ventricular arrhythmias (SVAs) are poorly understood. OBJECTIVES: This study aims to investigate sex-specific risk of SVAs and device therapies by balancing sex groups in relation to several baseline characteristics with the propensity score (PS). METHODS: We used a large remote monitoring dataset from implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds). Study endpoints were time to the first appropriate SVA, time to the first device therapy for SVA, and time to the first ICD shock. Results were compared between females and a PS-matched male subgroup. RESULTS: In a cohort of 2,532 patients with an ICD or CRT-D (median age, 70 years), 488 patients (19.3%) were women. After selecting 488 men PS-matched for 19 variables relative to baseline demographics, implant indications, principal comorbidities, and concomitant therapy, yet the SVA rate at the 2.1-year median follow-up was significantly lower in women than in man (adjusted HR: 0.65; 95% CI: 0.51-0.81; P < 0.001). Women also showed a reduced risk of any device therapy (HR: 0.59; 95% CI: 0.45-0.76; P < 0.001) and shocks (HR: 0.66; 95% CI: 0.47-0.94; P = 0.021). Differences in sex-specific SVA risk profile were not confirmed in CRT-D patients (HR: 0.78; 95% CI: 0.55-1.09; P = 0.14) nor in those with an ejection fraction <30% (HR: 0.80; 95% CI: 0.52-1.23; P = 0.31). CONCLUSIONS: After matching demographics, indications, principal comorbidities, and concomitant therapy, women still exhibited a lower SVA risk profile than men, except in the subgroups of CRT-D or/and ejection fraction <30%.


Asunto(s)
Desfibriladores Implantables , Humanos , Masculino , Femenino , Anciano , Desfibriladores Implantables/efectos adversos , Puntaje de Propensión , Resultado del Tratamiento , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Cardioversión Eléctrica
7.
Pacing Clin Electrophysiol ; 45(5): 612-618, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35383979

RESUMEN

BACKGROUND: Although radiofrequency (RF) catheter ablation of cavo-tricuspid isthmus (CTI) is an established treatment for typical right atrial flutter (RAFL), it remains to be established whether local tissue impedance (LI) is able to predict effective CTI ablation and what LI drop values during ablation should be used to judge a lesion as effective. We aimed to investigate the ability of LI to predict ablation efficacy in patients with RAFL. METHODS: RF delivery was guided by the DirectSense™ algorithm. Successful single RF application was defined according to a defragmentation of atrial potentials (DAP), reduction of voltage (RedV) by at least 80% or changes on unipolar electrogram (UPC). The ablation endpoint was the creation of bidirectional conduction block (BDB) across the isthmus. RESULTS: 392 point-by-point RF applications were analyzed in 48 consecutive RAFL patients. The mean baseline LI was 105.4 ± 12Ω prior to ablation and 92.0 ± 11Ω after ablation (p < 0.0001). According to validation criteria, absolute drops in impedance were larger at successful ablation sites than at ineffective ablation sites (DAP: 17.8 ± 6Ω vs. 8.7 ± 4Ω; RedV: 17.2 ± 6Ω vs. 7.8 ± 5Ω; UPC: 19.6 ± 6Ω vs. 10.1 ± 5Ω, all p < 0.0001). LI drop values significantly increased according to the number of criteria satisfied (ranging from 7.5Ω to 19.9). BDB was obtained in all cases. No procedure-related adverse events were reported. CONCLUSIONS: A LI-guided approach to CTI ablation was safe and effective in treating RAFL. The magnitude of LI drop was associated with effective lesion formation and BDB and could be used as a marker of ablation efficacy. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Ablación por Catéter/efectos adversos , Impedancia Eléctrica , Bloqueo Cardíaco/etiología , Humanos , Resultado del Tratamiento
8.
J Interv Card Electrophysiol ; 63(3): 749-758, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35322330

RESUMEN

PURPOSE: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have emerged as a viable real-time indicator of tissue characteristics and the consequent durability of the lesions created. We investigated the impact of catheter-tissue contact force (CF) on LI behavior during pulmonary vein isolation (PVI). METHODS: Forty-five consecutive patients of the CHARISMA registry undergoing de novo AF radiofrequency (RF) catheter ablation with a novel open-irrigated-tip catheter endowed with CF and LI measurement capabilities (Stablepoint™ catheter, Boston Scientific) were included. RESULTS: A total of 2895 point-by-point RF applications were analyzed (RF delivery time (DT) = 8.7±4s, CF = 13 ±±8 g, LI drop = 23 ±±7 Ω). All PVs were successfully isolated in an overall procedure time of 118 ±±34 min (fluoroscopy time = 13 ±±8 min). The magnitude of LI drop weakly correlated with CF (r = 0.13, 95% confidence interval (CI): 0.09 to 0.16, p < 0.0001), whereas both CF and LI drop inversely correlated with DT (r = -0.26, 95%CI: -0.29 to -0.22, p < 0.0001 for CF; r = -0.36, 95%CI: -0.39 to -0.33, p < 0.0001 for LI). For each 10 g of CF, LI drop markedly increased from 22.4 ± 7 Ω to 24.0 ± 8 Ω at 5 to 25 g CF intervals (5-14 g of CF vs 15-24 g of CF, p < 0.0001), whereas it showed smooth transition over 25 g (24.8 ± 7Ω at ≥ 25 g CF intervals, p = 0.0606 vs 15-24 g of CF). No major complications occurred during the procedures or within 30 days. CONCLUSIONS: CF significantly affects LI drop and probable consequent lesion formation during RF PVI. The benefit of higher contact (> 25 g) between the catheter and the tissue appears to have less impact on LI drop. TRIAL REGISTRATION: Catheter Ablation of Arrhythmias With High Density Mapping System in the Real World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Impedancia Eléctrica , Humanos , Venas Pulmonares/cirugía , Sistema de Registros , Resultado del Tratamiento
9.
J Interv Card Electrophysiol ; 64(3): 607-619, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34709504

RESUMEN

PURPOSE: The purpose of this study was to assess the available mortality risk stratification models for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRT-D) patients. METHODS: We conducted a review of mortality risk stratification models and tested their ability to improve prediction of 1-year survival after implant in a database of patients who received a remotely controlled ICD/CRT-D device during routine care and included in the independent Home Monitoring Expert Alliance registry. RESULTS: We identified ten predicting models published in peer-reviewed journals between 2000 and 2021 (Parkash, PACE, MADIT, aCCI, CHA2DS2-VASc quartiles, CIDS, FADES, Sjoblom, AAACC, and MADIT-ICD non-arrhythmic mortality score) that could be tested in our database as based on common demographic, clinical, echocardiographic, electrocardiographic, and laboratory variables. Our cohort included 1,911 patients with left ventricular dysfunction (median age 71, 18.3% female) from sites not using any risk stratification score for systematic patient screening. Patients received an ICD (53.8%) or CRT-D (46.2%) between 2011 and 2017, after standard physician evaluation. There were 56 deaths within 1-year post-implant, with an all-cause mortality rate of 2.9% (95% confidence interval [CI], 2.3-3.8%). Four predicting models (Parkash, MADIT, AAACC, and MADIT-ICD non-arrhythmic mortality score) were significantly associated with increased risk of 1-year mortality with hazard ratios ranging from 3.75 (CI, 1.31-10.7) to 6.53 (CI 1.52-28.0, p ≤ 0.014 for all four). Positive predictive values of 1-year mortality were below 25% for all models. CONCLUSION: In our analysis, the models we tested conferred modest incremental predicting power to ordinary screening methods.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Femenino , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
10.
ESC Heart Fail ; 8(6): 5204-5212, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34514741

RESUMEN

AIMS: There are conflicting data on the benefit of cardiac resynchronization therapy (CRT) in heart failure (HF) patients with permanent atrial fibrillation (AF). We aimed to compare patient outcomes according to the presence or absence of permanent AF at device implantation. METHODS AND RESULTS: We retrospectively analysed remote monitoring data from 1141 CRT defibrillators. Propensity score with inverse-probability weighting method was used to balance AF and sinus rhythm (SR) groups. Analysis endpoints included total mortality, appropriate defibrillation shocks, and CRT percentage. There were 229 patients (20.1%) in the AF group and 912 patients (79.9%) in the SR group. Compared with SR patients, AF patients were older (median age, 77 vs. 72 years, P < 0.001), more frequently male (82.5% vs. 75.5%, P = 0.02), and had higher heart rate (75.7 vs. 71.0 b.p.m., P < 0.001). Of the 229 AF patients, 162 (70.7%) received suboptimal CRT (<98%) and 67 (29.3%) had adequate CRT (≥98%). During a median follow-up of 24 months, total mortality did not differ between AF and SR groups (propensity-score-weighted hazard ratio, HR 1.32 [95% confidence interval, 0.82-2.15], P = 0.25). The risk of appropriate shocks was significantly higher in the AF group with <98% CRT than in the SR group (weighted-HR, 1.99 [1.21-3.26], P = 0.006) and was similar in the AF group with ≥98% CRT versus the SR group (1.29 [0.66-2.53], P = 0.45). During follow-up, sinus rhythm was recovered in 23 patients in the AF group (10%) after a median time of 106 (42-256) days. The rate of sinus rhythm recovery in the AF group was 4.5 (95% CI, 2.8-6.7) per 100 patient-years; the rate of permanent AF occurrence in the SR group was 2.5 (95% CI, 1.9-3.3) per 100 patient-years. CONCLUSIONS: Although mortality was similar across patient groups, patients with permanent AF and suboptimal CRT had twofold higher risk of appropriate shocks than SR patients or AF patients with CRT ≥ 98%.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Anciano , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Terapia de Resincronización Cardíaca/métodos , Desfibriladores , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
11.
Eur J Clin Pharmacol ; 77(12): 1835-1842, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34279677

RESUMEN

PURPOSE: Sacubitril/valsartan has been associated with a positive reverse left ventricular remodelling in patients with heart failure with reduced ejection fraction (HFrEF). These patients may also benefit from an ICD implant. We aimed to assess EF improvement after 6 months of treatment with sacubitril/valsartan, evaluating when ICD as primary prevention was no longer indicated. METHODS: Multicentre, observational, prospective study enrolling all consecutive patients with HFrEF and EF ≤ 35% with an ICD as primary prevention and starting treatment with sacubitril/valsartan (NCT03935087). Resynchronization therapy and patients experiencing appropriate ICD therapies before sacubitril/valsartan were excluded. RESULTS: Two-hundred-and-thirty patients were enrolled (73.9% males, mean age 64.3 ± 12.1 years) After 6 months of treatment, a reduction in left ventricular end-diastolic and end-systolic volumes was noted and LVEF increased from 28.3 ± 5.6% to 32.2 ± 6.5% (p < 0.001). At 6 months, a non-ischemic aetiology of cardiomyopathy and a final dose of sacubitril/valsartan > 24/26 mg twice daily were associated with a higher probability of an absolute increase of > 5% in LVEF. A total of 5.3% of primary prevention patients still had an arrhythmic event in the first 6 months after treatment with sacubitril/valsartan started. CONCLUSIONS: Sacubitril/valsartan improves systolic function in HFrEF, mainly due to reverse left ventricular remodelling. Improvement in EF after 6 months of treatment could help prevent ICD implantation in nearly one out of four patients, with important clinical and economic implications. However, the risk of sudden cardiac death in this recovered HFrEF population has not been thoroughly studied, and the present data should be interpreted only as hypothesis-generating.


Asunto(s)
Aminobutiratos/uso terapéutico , Compuestos de Bifenilo/uso terapéutico , Desfibriladores Implantables , Insuficiencia Cardíaca/tratamiento farmacológico , Valsartán/uso terapéutico , Función Ventricular Izquierda/efectos de los fármacos , Anciano , Comorbilidad , Combinación de Medicamentos , Femenino , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
12.
J Cardiovasc Electrophysiol ; 32(9): 2528-2535, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34252991

RESUMEN

INTRODUCTION: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D). METHODS: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated. Episodes were grouped in six 4-h timeslots from 00:00 to 24:00. Circadian distributions and adjusted marginal odds ratios (ORs), with 95% confidence interval (CI), were analyzed using mixed-effect models and logit generalized estimating equations, respectively, to account for within-subject correlation of multiple episodes. RESULTS: Among 1303 VA episodes from 446 patients (63% ICD and 37% CRT-D), 120 (9%) self-extinguished, and 842 (65%) were terminated by ATP, 343 (26%) by shock. VAs clustered from 08:00 to 16:00 with 44% of episodes, as compared with 22% from 00:00 to 08:00 (p < .001) and 34% from 16:00 to 24:00 (p = .005). Episodes were more likely to be polymorphic at night with an adjusted marginal OR of 1.66 (CI, 1.15-2.40; p = .007) at 00:00-04:00 versus other timeslots. Episodes were less likely to be terminated by ATP in the 00:00-04:00 (success-to-failure ratio, 0.67; CI, 0.46-0.98; p = .039) and 08:00-12:00 (0.70; CI, 0.51-0.96; p = .02) timeslots, and most likely to be terminated by ATP between 12:00 and 16:00 (success-to-failure ratio 1.42; CI, 1.06-1.91; p = .02). CONCLUSION: VAs did not distribute uniformly over the 24 h, with a majority of episodes occurring from 08:00 to 16:00. Nocturnal episodes were more likely to be polymorphic. The efficacy of ATP depended on the time of delivery.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado del Tratamiento
13.
Curr Probl Cardiol ; 46(3): 100454, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31522883

RESUMEN

Brugada syndrome (BrS) was first described in 1992 as an aberrant pattern of ST segment elevation in right precordial leads with a high incidence of sudden cardiac death (SCD) in patients with structurally normal heart. It represents 4% ∼ 12% of all SCD and 20% of SCD in patients with structurally normal heart. The extremely wide genetic heterogeneity of BrS and other inherited cardiac disorders makes this new area of genetic arrhytmology a fascinating one. This review shows the state of art in diagnosis, management, and treatment of BrS focusing all the aspects regarding genetics and Preimplant Genetic Diagnosis (PGD) of embryos, overlapping syndromes, risk stratification, familial screening, and future perspectives. Moreover the review analyzes key points like electrocardiogram (ECG) criteria, the role of electrophysiological study (the role of ventricular programmed stimulation and the need of universal accepted protocol) and the importance of a correct risk stratification to clarify when implantable cardioverter defibrillator or a close follow-up is needed. In recent years, cardiovascular studies have been focused on personalized risk assessment and to determine the most optimal therapy for an individual. The BrS syndrome has also benefited of these advances although there remain several key points to be elucidated. We will review the present knowledge, progress made, and future research directions on BrS.


Asunto(s)
Síndrome de Brugada , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/terapia , Desfibriladores Implantables , Electrocardiografía , Humanos , Medición de Riesgo
14.
Eur Heart J ; 42(5): 508-516, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33279955

RESUMEN

AIM: The benefit of cardiac pacing in patients with severe recurrent reflex syncope and asystole induced by tilt testing has not been established. The usefulness of tilt-table test to select candidates for cardiac pacing is controversial. METHODS AND RESULTS: We randomly assigned patients aged 40 years or older who had at least two episodes of unpredictable severe reflex syncope during the last year and a tilt-induced syncope with an asystolic pause longer than 3 s, to receive either an active (pacing ON; 63 patients) or an inactive (pacing OFF; 64 patients) dual-chamber pacemaker with closed loop stimulation (CLS). The primary endpoint was the time to first recurrence of syncope. Patients and independent outcome assessors were blinded to the assigned treatment. After a median follow-up of 11.2 months, syncope occurred in significantly fewer patients in the pacing group than in the control group [10 (16%) vs. 34 (53%); hazard ratio, 0.23; P = 0.00005]. The estimated syncope recurrence rate at 1 year was 19% (pacing) and 53% (control) and at 2 years, 22% (pacing) and 68% (control). A combined endpoint of syncope or presyncope occurred in significantly fewer patients in the pacing group [23 (37%) vs. 40 (63%); hazard ratio, 0.44; P = 0.002]. Minor device-related adverse events were reported in five patients (4%). CONCLUSION: In patients aged 40 years or older, affected by severe recurrent reflex syncope and tilt-induced asystole, dual-chamber pacemaker with CLS is highly effective in reducing the recurrences of syncope. Our findings support the inclusion of tilt testing as a useful method to select candidates for cardiac pacing. STUDY REGISTRATION: ClinicalTrials.gov identifier NCT02324920, Eudamed number CIV-05-013546.


Asunto(s)
Estimulación Cardíaca Artificial , Paro Cardíaco , Adulto , Paro Cardíaco/etiología , Paro Cardíaco/terapia , Humanos , Reflejo , Síncope/etiología , Síncope/terapia , Pruebas de Mesa Inclinada , Resultado del Tratamiento
15.
J Arrhythm ; 36(2): 353-362, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32256887

RESUMEN

BACKGROUND: Parameters measured during implantable cardioverter defibrillator (ICD) implant also depend on bioelectrical properties of the myocardium. We aimed to explore their potential association with clinical outcomes in patients with single/dual-chamber ICD and cardiac resynchronization therapy defibrillator (CRT-D). METHODS: In the framework of the Home Monitoring Expert Alliance, baseline electrical parameters for all implanted leads were compared by the occurrence of all-cause mortality, adjudicated ventricular arrhythmia (VA), and atrial high-rate episode lasting ≥24 hours (24 h AHRE). RESULTS: In a cohort of 2976 patients (58.1% ICD) with a median follow-up of 25 months, event rates were 3.1/100 patient-years for all-cause mortality, 18.1/100 patient-years for VA, and 9.3/100 patient-years for 24 h AHRE. At univariate analysis, baseline shock impedance was consistently lower in groups with events than without, with a 40 Ω cutoff that better identified high-risk patients. However, at multivariable analysis, the adjusted-hazard ratios (HRs) lost statistical significance for any endpoint. Baseline atrial sensing amplitude during sinus rhythm was lower in patients with 24 h AHRE than in those without (2.45 [IQR: 1.65-3.85] vs 3.51 [IQR: 2.37-4.67] mV, P < .01). The adjusted HR for 24 h AHRE in patients with atrial sensing >1.5 mV vs those with values ≤1.5 mV was 0.52 (95% CI: 0.33-0.83), P = .006. CONCLUSIONS: Although lower baseline shock impedance was observed in patients with events, the association lost statistical significance at multivariable analysis. Conversely, low sinus rhythm atrial sensing (≤1.5 mV) measured with standard transvenous leads could identify subjects at high risk of atrial arrhythmia.

16.
Europace ; 22(6): 888-896, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32219388

RESUMEN

AIMS: The GOLD AF Registry has been designed to prospectively assess the population, indications, and outcomes using second-generation phased radiofrequency (RF) ablation (pulmonary vein ablation catheter GOLD) in a global examination of standard-of-care use for the treatment of paroxysmal and persistent atrial fibrillation (AF). METHODS AND RESULTS: GOLD AF (NCT02433613) is a prospective, observational, multi-centre registry designed to characterize efficacy and safety of phased RF ablation in patients with AF. The primary endpoint was freedom from AF recurrence at 12-month follow-up after a 90-day blanking period. Ancillary objectives include safety, procedural efficiency, and quality of life (QoL). The QoL assessment using the Atrial Fibrillation Effect on QualiTy-of-Life (AFEQT) and the European Heart Rhythm Association (EHRA) Score of AF-related symptoms was collected at baseline and 12 months. In total, 1054 patients were included in this analysis (age 60.6, 67.6% male, 26.5% PersAF). Kaplan-Meier estimate of freedom from AF recurrence was 77.7% at 12 months. Peri-procedural device or procedure-related complications were observed in 26 (2.5%) patients, with a low stroke rate of 0.3%. One-year post-ablation, the EHRA AF Symptom score decreased in 68% of patients. The AFEQT score improvement was observed in 88.4% and 90.4% of patients who completed the questionnaire in-person or interviewed by phone at 12 month follow-up, respectively. CONCLUSION: Phased RF ablation for the treatment of paroxysmal and persistent AF demonstrated a 77.7% freedom from AF recurrence at 12 months in addition to a significant reduction in arrhythmia symptoms and clinically meaningful improved QoL. Low peri-procedural complication rate of <3% was reported.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Catéteres , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/cirugía , Calidad de Vida , Recurrencia , Sistema de Registros , Resultado del Tratamiento
17.
JACC Clin Electrophysiol ; 5(10): 1197-1208, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31648745

RESUMEN

OBJECTIVES: This study evaluated the temporal association between atrial high-rate episodes (AHREs) and sustained ventricular arrhythmias (VAs) in a remotely monitored cohort with implantable cardioverter-defibrillators (ICD) with and/or without cardiac resynchronization therapy with a defibrillator (CRT-D). BACKGROUND: Clinical relevance of AHREs in terms of VA rate and survival has not been outlined yet. METHODS: This study analyzed data of patients with ICDs and CRT-Ds from the nationwide Home Monitoring Expert Alliance network. The cohort included 2,435 patients with a median follow-up of 25 months (interquartile range: 13 to 42 months) and age 70 years (range 61 to 77 years); 19.7% were women, 51.4% had coronary artery disease, and 45.2% had a CRT-D. There were 3,410 appropriate VA episodes; 498 (14.6%) were preceded by AHREs within 48 h; in 85.5% of this group, AHREs were still ongoing at episode onset. RESULTS: In a longitudinal analysis, the odds ratios (ORs) of experiencing any VA in a 30-day interval with AHREs versus intervals without AHREs were 2.35 (95% confidence interval [CI]: 1.86 to 2.97; p < 0.001) for ventricular tachycardia (VT), 3.06 (95% CI: 2.35 to 3.99; p < 0.001) for fast VT, 1.84 (95% CI: 1.36 to 2.48; p < 0.001) for self-extinguishing ventricular fibrillation (VF), and 2.31 (95% CI: 1.17 to 4.57; p = 0.01) for VF. ORs decreased with increasing AHRE burden. Patients with AHREs 48 h before VAs were more likely to experience VA recurrences (adjusted hazard ratio [HR]: 1.78; 95% CI: 1.41 to 2.24; p < 0.001) and had higher overall mortality (HR: 2.67; 95% CI: 1.68 to 4.23; p < 0.001). CONCLUSIONS: AHREs were not uncommon 48 h before VAs, which tended to be distributed around intervals with AHREs. Temporal connection between AHREs and VAs was a marker of increased risk of VA recurrence and a poorer prognosis.


Asunto(s)
Fibrilación Atrial/epidemiología , Aleteo Atrial/epidemiología , Mortalidad , Taquicardia Supraventricular/epidemiología , Taquicardia Ventricular/epidemiología , Fibrilación Ventricular/epidemiología , Anciano , Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Tecnología de Sensores Remotos , Riesgo , Factores de Tiempo
18.
Clin Cardiol ; 42(9): 820-828, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31282000

RESUMEN

BACKGROUND: The role of atrial rate-responsive (RR) pacing in cardiac resynchronization therapy (CRT) is unclear due to the favorable effect of rate lowering in systolic heart failure. Atrial high rate episodes (AHREs) in CRT recipients are particularly worrisome since they cause loss of CRT, beyond representing a stroke risk factor. HYPOTHESIS: The presence of an association between RR and the incidence of AHREs. METHODS: Daily remote transmissions from 836 CRT recipients were analyzed. AHREs were classified by duration: ≥15 minutes, ≥5 hours, and ≥ 24 hours. Variables possibly associated to AHREs were included in time-dependent proportional-hazard models, averaging over 30-day periods and adjusting for main baseline variables. RESULTS: After a median follow-up of 23.9 (12.2-36.0) months, 507 (60.6%) patients experienced at least one 15-minute AHRE. RR function was programmed in 166 (19.8%) patients and was associated with an increased AHRE occurrence rate with hazard ratio (HR) ranging from 1.45 to 1.78 for the 3 cutoffs of episode duration. The negative effect of RR function was not observed in the subset of patients with low mean heart rate (<68 bpm). Higher mean heart rates increased AHRE risk (HR:1.02, P = .01), while CRT amount decreased it (HR:0.98, P < .01). The extent of atrial pacing did not predict AHRE occurrence. CONCLUSIONS: RR pacing in CRT recipients is associated with increased AHRE occurrence, especially when an average heart rate > 68 bpm is attained.

19.
Clin Cardiol ; 42(10): 919-924, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31301152

RESUMEN

OBJECTIVES: The aim of the study was to confirm the value of the VALID-cardiac resynchronization therapy (CRT) risk score in predicting outcome and to assess its association with clinical response (CR) in an unselected real-world CRT population. METHODS AND RESULTS: The present analysis comprised all consecutive CRT patients (pts) enrolled in the CRT-MORE registry from 2011 to 2013. Pts were stratified into five groups (quintiles 1-5) according to the VALID-CRT risk predictor index applied to the CRT-MORE population. In the analysis of clinical outcome, adverse events comprised death from any cause and non-fatal heart failure (HF) events requiring hospitalization. CR at 12-month follow-up was also assessed. We enrolled 905 pts. During a median follow-up of 1005 [627-1361] days, 134 patients died, and 79 had at least one HF hospitalization. At 12 months, 69% of pts displayed an improvement in their CR. The mean VALID-CRT risk score derived from the CRT-MOdular Registry (MORE) population was 0.317, ranging from -0.419 in Q1 to 2.59 in Q5. The risk-stratification algorithm was able to predict total mortality after CRT (survival ranging from 93%-Q1 to 77%-Q5; hazards ratio [HR] = 1.42, 95% confidence interval [CI]: 1.25-1.61, P < .0001), and HF hospitalization (ranging from 95% to 90%; HR = 1.24, 95% CI: 1.06-1.45, P = .009). CR was significantly lower in pts with a high-to-very high risk profile (Q4-5) than in pts with a low-to-intermediate risk profile (Q1-2-3) (55% vs 79%, P < .0001). CONCLUSION: The VALID-CRT risk-stratification algorithm reliably predicts outcome and CRT response after CRT in an unselected, real-world population.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Sistema de Registros , Medición de Riesgo/métodos , Función Ventricular Izquierda/fisiología , Remodelación Ventricular/fisiología , Anciano , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Factores de Tiempo
20.
J Cardiovasc Electrophysiol ; 30(9): 1626-1635, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31165517

RESUMEN

INTRODUCTION: Clinical trials did not provide conclusive evidence concerning the benefit of prophylactic implantable cardioverter-defibrillators (ICDs) in patients with severe nonischemic cardiomyopathy (NICM). We aimed to compare incidence of appropriate sustained ventricular arrhythmia (SVA) and device therapy in ischemic cardiomyopathy (ICM) vs NICM ICD and/or cardiac resynchronization therapy (CRT-D) patients. METHODS AND RESULTS: We analyzed remote-monitoring data from devices of the Home Monitoring Expert Alliance network. SVA recordings were adjudicated by three independent electrophysiologists. Our cohort included 1,946 patients who received either an ICD (55%) or a CRT-D (45%) for primary prevention of sudden cardiac death. Median (interquartile range) age was 70 (62-77) years, 81% were male, and 52% were in the ICM group. Patients were remotely monitored for a maximum follow-up of 5 years. The 5-year product-limit estimate of SVA incidence in patients with an ICD was 47.3% (95% confidence interval [CI], 41.0%-53.9%) in the ICM group and 44.7% (36.9%-53.3%) in the NICM group. In patients with a CRT-D, SVA incidence was 45.7% (37.3%-55.0%) in ICM patients and 49.2% (40.4%-58.7%) in NICM patients. The adjusted hazard ratio for SVA in the ICM vs NICM group was 0.96 (95% CI: 0.70-1.30, P = .77) in ICD patients and 0.85 (95% CI: 0.61-1.18, P = .34) in CRT-D patients. SVAs triggered appropriate device therapies with similar incidence in all groups. CONCLUSION: In a large cohort of remotely monitored ICD and CRT-D recipients, SVA incidence did not significantly differ in ICM and NICM patients.


Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Cardiomiopatías/fisiopatología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Prevención Primaria/instrumentación , Tecnología de Sensores Remotos , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Cardiomiopatías/diagnóstico , Cardiomiopatías/mortalidad , Causas de Muerte , Bases de Datos Factuales , Muerte Súbita Cardíaca/epidemiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/fisiopatología , Valor Predictivo de las Pruebas , Falla de Prótesis , Factores de Riesgo , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Resultado del Tratamiento