Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 87(5): 053501, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27250417

RESUMEN

A next-generation neutron temporal diagnostic (NTD) capable of recording high-quality data for the highest anticipated yield cryogenic deuterium-tritium (DT) implosion experiments was recently installed at the Omega Laser Facility. A high-quality measurement of the neutron production width is required to determine the hot-spot pressure achieved in inertial confinement fusion experiments-a key metric in assessing the quality of these implosions. The design of this NTD is based on a fast-rise-time plastic scintillator, which converts the neutron kinetic energy to 350- to 450-nm-wavelength light. The light from the scintillator inside the nose-cone assembly is relayed ∼16 m to a streak camera in a well-shielded location. An ∼200× reduction in neutron background was observed during the first high-yield DT cryogenic implosions compared to the current NTD installation on OMEGA. An impulse response of ∼40 ± 10 ps was measured in a dedicated experiment using hard x-rays from a planar target irradiated with a 10-ps short pulse from the OMEGA EP laser. The measured instrument response includes contributions from the scintillator rise time, optical relay, and streak camera.

2.
Rev Sci Instrum ; 86(1): 016105, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25638132

RESUMEN

An upgrade of the pulsed magnetic field generator magneto-inertial fusion electrical discharge system [O. Gotchev et al., Rev. Sci. Instrum. 80, 043504 (2009)] is described. The device is used to study magnetized high-energy-density plasma and is capable of producing a pulsed magnetic field of tens of tesla in a volume of a few cubic centimeters. The magnetic field is created by discharging a high-voltage capacitor through a small wire-wound coil. The coil current pulse has a duration of about 1 µs and a peak value of 40 kA. Compared to the original, the updated version has a larger energy storage and improved switching system. In addition, magnetic coils are fabricated using 3-D printing technology which allows for a greater variety of the magnetic field topology.

3.
Rev Sci Instrum ; 85(11): 11D901, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430279

RESUMEN

A magnetic particle time-of-flight (MagPTOF) diagnostic has been designed to measure shock- and compression-bang time using D(3)He-fusion protons and DD-fusion neutrons, respectively, at the National Ignition Facility (NIF). This capability, in combination with shock-burn weighted areal density measurements, will significantly constrain the modeling of the implosion dynamics. This design is an upgrade to the existing particle time-of-flight (pTOF) diagnostic, which records bang times using DD or DT neutrons with an accuracy better than ±70 ps [H. G. Rinderknecht et al., Rev. Sci. Instrum. 83, 10D902 (2012)]. The inclusion of a deflecting magnet will increase D(3)He-proton signal-to-background by a factor of 1000, allowing for the first time simultaneous measurements of shock- and compression-bang times in D(3)He-filled surrogate implosions at the NIF.

4.
Rev Sci Instrum ; 84(4): 043506, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23635195

RESUMEN

The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, ion-temperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

5.
Rev Sci Instrum ; 83(10): 10E119, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126941

RESUMEN

The south pole bang-time diagnostic views National Ignition Facility (NIF) implosions through the lower Hohlraum laser entrance hole to measure the time of peak x-ray emission (peak compression) in indirect-drive implosions. Five chemical-vapor-deposition diamond photoconductive detectors with different filtrations and sensitivities record the time-varying x rays emitted by the target. Wavelength selecting highly oriented pyrolytic graphite crystal mirror monochromators increase the x-ray signal-to-background ratio by filtering for 11-keV emission. Diagnostic timing and the in situ temporal instrument response function are determined from laser impulse shots on the NIF. After signal deconvolution and background removal, the bang time is determined to 45-ps accuracy. The x-ray "yield" (mJ∕sr∕keV at 11 keV) is determined from the time integral of the corrected peak signal.

6.
Rev Sci Instrum ; 83(10): 10E122, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126944

RESUMEN

The elliptically curved pentaerythritol (PET) crystals used in the Supersnout 2 x-ray spectrometer on the National Ignition Facility at Lawrence Livermore National Laboratory have been calibrated photometrically in the range of 5.5-16 keV. The elliptical geometry provides broad spectral coverage and minimizes the degradation of spectral resolution due to the finite source size. The reflectivity curve of the crystals was measured using a x-ray line source. The integrated reflectivity (R(I)) and width of its curve (ΔΘ) were the measurements of major interest. The former gives the spectrometer throughput, and the latter gives the spectrometer resolving power. Both parameters are found to vary considerably with the radius of curvature of the crystal and with spectral energy. The results are attributed to an enhanced mosaic effect due to the increase in curvature. There are also contributions from the crystal cleaving and gluing processes.

7.
Toxicon ; 31(1): 75-83, 1993 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8383366

RESUMEN

Liquid chromatography (LC)-linked protein phosphatase 1/2A (PP-1/PP2A) bioassay was used to quantitatively identify diarrhetic shellfish toxins in marine phytoplankton (cultured and natural assemblages) and commercially available mussels. Using this approach, multiple protein phosphatase inhibitor profiles of varying composition were found in diarrhetic mussels from Holland and Canada. Based on LC elution positions and relative activity versus PP-1 and PP-2A, at least six inhibitors distinct from known diarrhetic shellfish toxins were identified and termed mussel phosphatase inhibitor (MPI) 19,22,23,25,33 and 42. The levels of these inhibitors, in okadaic acid equivalent units, varied from 100 pg to 3350 ng per g shellfish tissue. The combined levels of PP-1/2A inhibitors in all instances superseded that of okadaic acid/dinophysistoxin-1 and may contribute to the diarrhetic shellfish toxin profile of the contaminated mussels. The efficacy of LC-protein phosphatase bioassay was established for cultured phytoplankton where picogram levels of okadaic acid could be detected from microgram extracts of Prorocentrum lima. Analyses of plankton net tows from estuarine mussel culture sites in Eastern Canada revealed a heterogeneous population of protein phosphatase inhibitors, with dinophysistoxin-1 being most prevalent. This toxin was predominant for at least 2 months in mussel populations in the immediate vicinity of plankton sampling sites. The results are consistent with a hypothetical model in which marine bacteria, cyanobacteria and dinoflagellates combine to produce a variety of protein phosphatase inhibitors effective against signal transduction pathways in higher eukaryotes.


Asunto(s)
Bivalvos/química , Diarrea/inducido químicamente , Toxinas Marinas/análisis , Fosfoproteínas Fosfatasas/antagonistas & inhibidores , Fitoplancton/química , Animales , Cromatografía Liquida , Éteres Cíclicos/análisis , Ácido Ocadaico , Proteína Fosfatasa 1 , Piranos/análisis , Conejos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...