Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Intervalo de año de publicación
1.
Soc Work Public Health ; : 1-10, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38651536

RESUMEN

The study aimed to determine the application of the health belief model (HBM) in the acceptance of COVID-19 vaccination among health workers in 2021. The cross-sectional study was conducted on 3600 health workers from February to March 2021. Data was collected using a researcher-made questionnaire that included the intention to receive vaccines based on the health belief model constructs. Data were analyzed using descriptive statistics indicators, Chi-square, ANOVA test, and logistic regression model at a 95% confidence level. More than 62% of the participants intended to receive the vaccine. The odds of intention to receive the vaccine among people who worked in the health center and did not have a history of hospitalization due to COVID-19 disease were 1.50 and 2.10 units more than the others. Intention to receive the vaccine in individuals with high perceived sensitivity was 1.10 units. Furthermore, in terms of perceived benefits, self-efficacy, and cue-to-action constructs were 1.15, 1.34, and 1.65 units respectively. The rate of vaccine acceptance among Iranian health care workers was relatively good and the constructs of HBM in predicting the rate of intention to receive the vaccine had good applicability.

2.
Inquiry ; 60: 469580231168494, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37246730

RESUMEN

Acceptance of the SARS-CoV-2) COVID-19( vaccine is a very important factor to keep health workers safe. The study aimed to evaluate the psychometric properties of intention to receive the COVID-19 vaccine using a health belief model among health workers in Iran The study was a tools design study that was conducted in the period from February to March 2020, Iran Questionnaire items were designed using text review. The sampling method was multi-stage. Data were analyzed using descriptive statistics, confirmatory and exploratory factor analysis at a 95% confidence level using SPSS software version 16. The designed questionnaire had an appropriate content validity and internal consistency. Also, the exploratory factor analysis showed that a 5-factor structure was extracted and confirmatory factor analyses revealed that the conceptual five-factor structure of the measure had good fit indices. Reliability was evaluated using internal consistency. Cronbach Alpha coefficient was .82 and the intra-class correlation coefficient (ICC) was .9. It can be concluded that the instrument designed in the preliminary stage of psychometrics properties had good validity and reliability indicators. Also, the constructs of the health belief model well explain the determinants of the intention to receive the COVID-19 vaccine at the individual level.


Asunto(s)
COVID-19 , Intención , Humanos , COVID-19/prevención & control , Vacunas contra la COVID-19/administración & dosificación , Análisis Factorial , Modelo de Creencias sobre la Salud , Psicometría/métodos , Reproducibilidad de los Resultados , SARS-CoV-2 , Encuestas y Cuestionarios , Vacilación a la Vacunación
3.
Biochem Genet ; 61(5): 2149-2158, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36966459

RESUMEN

Hypertension (HTN) is a global health challenge and increase the risk of cardiovascular disease. Hypertension has a multifactorial course of evolution, with both genetic and environmental factors playing an important role. To date, a number of genes and pathways have been proposed to be associated with HTN, among which is Nitric Oxide pathway. NO levels can be regulated by reactive oxygen species (ROS), superoxide and post-transcriptional mechanisms, including sense-anti sense interactions. NOS3AS gene encodes an antisense RNA (sONE) which is complementary to NOS3 transcript in 662 nucleotides and may regulate NOS3 in a post-transcriptional manner. In this study, we sought to define the role of NOS3AS in the pathophysiology of essential HTN. A total of 131 cases with hypertension and 115 controls were enrolled in the study. Peripheral blood was drawn from all study participants after signing the informed consent form. Three variants (rs71539868, rs12666075 and rs7830) were investigated by Tetra-ARMS PCR method. The results were then statistically analyzed. We found statistically significant association between rs7830 TT genotype, rs12666075 GT and TT genotypes with susceptibility to HTN. We failed to observe association between rs71539868 and susceptibility to HTN. The present study showed a strong association between NOS3AS variants and susceptibility to hypertension in the population of Kermanshah province. Our results may shed more light on the mechanisms of disease development and may also help to better identify genetic predispositions and individuals at risk.


Asunto(s)
Hipertensión , Óxido Nítrico Sintasa de Tipo III , Humanos , Irán , Óxido Nítrico Sintasa de Tipo III/genética , Hipertensión Esencial/genética , Hipertensión/genética , Predisposición Genética a la Enfermedad
4.
Rev. bras. cir. cardiovasc ; 37(5): 674-679, Sept.-Oct. 2022. tab
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1407286

RESUMEN

ABSTRACT Introduction: Prosthetic valve dysfunction is a potentially critical complication of heart valve replacement. An easy and quickly applicable diagnostic procedure is required for recognizing the prosthetic valve dysfunction. The purpose of this study was to prospectively define the diagnostic value of D-dimer and INR level in predicting prosthetic valve dysfunction. Methods: This cross-sectional study was performed in 70 patients suspected to have prosthetic valve dysfunction admitted to Imam Ali Hospital, affiliated with Kermanshah University of Medical Sciences (KUMS), Kermanshah Province, Iran. Cinefluoroscopy, as the gold standard diagnostic test, was used for the diagnosis of prosthetic valve dysfunction in enrolled patients. Two milliliters of blood from each patient were taken into a tube containing sodium citrate anticoagulant. To evaluate D-dimer, the cutoff value was set at 500 ng/ml. Also, to evaluate international normalized ratio (INR), the cutoff value was set at 2. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of the serum markers were used to describe predictive properties. Results: Of 70 patients, 27 (38.6%) were male and 43 (61.4%) were female, and the mean age was 54.67±15.11 years (range, 18 to 80 years). Of 70 patients, 27 (38.6%) had prosthetic heart valve malfunction demonstrable by fluoroscopy, and 19 patients (27.1%) had D-dimer levels >500 ng/ml. Elevated D-dimer levels (>500 ng/ml) have been indicated to have sensitivity of 70.4%, and hence an NPV of 84.3%, specificity of 100%, PPV of 100%, NLR of 0.3, and the infinity value of PLR for predicting prosthetic valve dysfunction. There was a significant relationship between fluoroscopy and D-dimer test (P=0.001). A kappa coefficient value of 0.745 indicated a substantial agreement between D-dimer and fluoroscopy testing. Mixing test (combination of D-dimer and INR) showed to have 100% sensitivity, and hence a NPV of 69.8%, specificity of 69.8%, PPV of 51.8%, NLR of 1.41, and PLR of 1.44 for predicting prosthetic valve dysfunction. Conclusion: D-dimer with moderate sensitivity and high specificity is an ideal marker for the diagnosis of prosthetic valve dysfunction in suspected patients. Enhanced plasma D-dimer level is not by itself diagnostic of a prosthetic valve dysfunction but may alert physicians to refer the patient for more detailed examination, preferably by fluoroscopy. Mixing test with 100% sensitivity can apply as a rule-out test.

5.
Braz J Cardiovasc Surg ; 37(5): 674-679, 2022 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-35244382

RESUMEN

INTRODUCTION: Prosthetic valve dysfunction is a potentially critical complication of heart valve replacement. An easy and quickly applicable diagnostic procedure is required for recognizing the prosthetic valve dysfunction. The purpose of this study was to prospectively define the diagnostic value of D-dimer and INR level in predicting prosthetic valve dysfunction. METHODS: This cross-sectional study was performed in 70 patients suspected to have prosthetic valve dysfunction admitted to Imam Ali Hospital, affiliated with Kermanshah University of Medical Sciences (KUMS), Kermanshah Province, Iran. Cinefluoroscopy, as the gold standard diagnostic test, was used for the diagnosis of prosthetic valve dysfunction in enrolled patients. Two milliliters of blood from each patient were taken into a tube containing sodium citrate anticoagulant. To evaluate D-dimer, the cutoff value was set at 500 ng/ml. Also, to evaluate international normalized ratio (INR), the cutoff value was set at 2. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of the serum markers were used to describe predictive properties. RESULTS: Of 70 patients, 27 (38.6%) were male and 43 (61.4%) were female, and the mean age was 54.67±15.11 years (range, 18 to 80 years). Of 70 patients, 27 (38.6%) had prosthetic heart valve malfunction demonstrable by fluoroscopy, and 19 patients (27.1%) had D-dimer levels >500 ng/ml. Elevated D-dimer levels (>500 ng/ml) have been indicated to have sensitivity of 70.4%, and hence an NPV of 84.3%, specificity of 100%, PPV of 100%, NLR of 0.3, and the infinity value of PLR for predicting prosthetic valve dysfunction. There was a significant relationship between fluoroscopy and D-dimer test (P=0.001). A kappa coefficient value of 0.745 indicated a substantial agreement between D-dimer and fluoroscopy testing. Mixing test (combination of D-dimer and INR) showed to have 100% sensitivity, and hence a NPV of 69.8%, specificity of 69.8%, PPV of 51.8%, NLR of 1.41, and PLR of 1.44 for predicting prosthetic valve dysfunction. CONCLUSION: D-dimer with moderate sensitivity and high specificity is an ideal marker for the diagnosis of prosthetic valve dysfunction in suspected patients. Enhanced plasma D-dimer level is not by itself diagnostic of a prosthetic valve dysfunction but may alert physicians to refer the patient for more detailed examination, preferably by fluoroscopy. Mixing test with 100% sensitivity can apply as a rule-out test.


Asunto(s)
Prótesis Valvulares Cardíacas , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Transversales , Productos de Degradación de Fibrina-Fibrinógeno , Prótesis Valvulares Cardíacas/efectos adversos , Relación Normalizada Internacional , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Adolescente , Adulto Joven , Anciano de 80 o más Años
6.
ARYA Atheroscler ; 16(6): 284-289, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34122582

RESUMEN

BACKGROUND: Circadian variation is known as an important factor in acute myocardial infarction (AMI). Moreover, the circadian pattern may help in disease prevention and better medication prescription. Therefore, the aim of our study was to investigate the circadian pattern of symptom onset in patients with ST-segment elevation myocardial infarction (STEMI). METHODS: This cross-sectional study was conducted on 777 patients admitted to the Imam Ali Cardiovascular Center, Kermanshah, Iran, with a diagnosis of STEMI from March 2018 to February 2019. Data were collected using a checklist developed based on the study's objectives. Differences between subgroups were assessed using one-way analysis of variance (ANOVA) with post-hoc testing and chi-square test (or Fisher's exact test). RESULTS: Out of the 777 patients, 616 (79.3%) were men. The mean and standard deviation (SD) of age of the patients was 60.93 ± 12.86 years. 380 patients (48.9%) were current smoker, 40.3% were hypertensive, 21.1% had hypercholesterolemia, 18.3% had diabetes mellitus (DM), 25.2% had history of angina, and about 15.0% had history of myocardial infarction (MI). The occurrence of STEMI was most common during hours between 06:01-12:00 (27.7%), followed by 12:01-18:00 (27.3%), 00:00-06:00 (24.3%), and 18:01-24:00 (20.7%), respectively. Gender was significantly associated with circadian pattern of STEMI. Women showed a double peak of symptom onset in 06:01-12:00 and 12:01-18:00. CONCLUSION: The present study of Iranian patients displayed circadian pattern of STEMI with 2 peaks in the morning and afternoon, and the both peaks were dominated by women.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...