Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Healthc Eng ; 2021: 1342316, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33628401

RESUMEN

[This corrects the article DOI: 10.1155/2020/2707560.].

2.
Polymers (Basel) ; 12(8)2020 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-32824363

RESUMEN

The aim of the current work was to analyze the influence of the ferrule effect for hybrid composite endodontic post designs consisting of carbon (C) and glass (G) fiber-reinforced polyetherimide (PEI), in upper canine teeth. Starting from theoretical designs of C-G/PEI hybrid composite posts with different Young's moduli (Post A-57.7 GPa, Post B-31.6 GPa, Post C-graduated from 57.7 to 9.0 GPa in the coronal-apical direction) in endodontically treated anterior teeth, the influence of the ferrule effect was determined through finite element analysis (FEA). On the surface of the crown, a load of 50 N was applied at 45° to the longitudinal axis of the tooth. Maximum principal stresses were evaluated along the C-G/PEI post as well as at the interface between the surrounding tooth structure and the post. Maximum stress values were lower than those obtained for the corresponding models without a ferrule. The presence of a ferrule led to a marked decrease of stress and gradients especially for posts A and B. A less marked effect was globally found for Post C, except in a cervical margin section along a specific direction, where a significant decrease of the stress was probably due to local geometric features, compared to the model without a ferrule. The presence of a ferrule did not generally provide a marked benefit in the case of the graduated Post C, in comparison to other C-G/PEI posts. The outcomes suggest how such a hybrid composite post alone should be sufficient to optimize the stress distribution, dissipating stress from the coronal to the apical end.

3.
J Healthc Eng ; 2019: 3212594, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31662833

RESUMEN

Mechanical and architectural features play an important role in designing biomedical devices. The use of materials (i.e., Ti6Al4V) with Young's modulus higher than those of natural tissues generally cause stress shielding effects, bone atrophy, and implant loosening. However, porous devices may be designed to reduce the implant stiffness and, consequently, to improve its stability by promoting tissue ingrowth. If porosity increases, mass transport properties, which are crucial for cell behavior and tissue ingrowth, increase, whereas mechanical properties decrease. As reported in the literature, it is always possible to tailor mass transport and mechanical properties of additively manufactured structures by varying the architectural features, as well as pore shape and size. Even though many studies have already been made on different porous structures with controlled morphology, the aim of current study was to provide only a further analysis on Ti6Al4V lattice structures manufactured by selective laser melting. Experimental and theoretical analyses also demonstrated the possibility to vary the architectural features, pore size, and geometry, without dramatically altering the mechanical performance of the structure.


Asunto(s)
Materiales Biocompatibles/química , Titanio/química , Aleaciones , Simulación por Computador , Módulo de Elasticidad , Rayos Láser , Ensayo de Materiales , Porosidad
4.
BMC Surg ; 18(Suppl 1): 21, 2019 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-31074383

RESUMEN

BACKGROUND: The combination of breast conserving surgery (BCS) with plastic surgery techniques has provided a useful surgical tool matching the radicality of the oncological excision with the preservation of breast cosmesis. Even though BCS represents a good option for surgical treatment of tumors located in these quadrants, wide excisions often necessitate breast reshaping in order to avoid nipple areola complex (NAC) displacement and skin retraction. We present a new surgical technique to repair upper-outer quadrants' defects following breast cancer excision using dermo-glandular flaps and an axillary adipo-fascial flap. METHODS: During the period from January 2014 to December 2015, 168 patients with an upper-outer quadrant's breast cancer have been treated in our Department. 83 women have been treated with the described oncoplastic technique and immediate contra-lateral symmetrisation and 85 women underwent standard BCS. We present surgical, oncological and cosmetic outcomes comparing our results with standard BCS. RESULTS: At a mean follow-up of 27 months loco-regional recurrences in the two groups were comparable. Short-term complication rates were comparable between the two groups. Re-intervention rates for positive margins were significantly higher in the standard BCS group. The overall satisfaction with cosmetic outcome both assessed by the patient and the surgeon was significantly higher in the oncoplastic group. CONCLUSIONS: The proposed oncoplastic technique represents a safe and effective solution for reshaping that follows upper-outer breast cancer wide excision, achieving comparable complication rates, lower re-intervention rates for positive margins and better cosmetic results when compared with standard BCS.


Asunto(s)
Neoplasias de la Mama/cirugía , Mamoplastia/métodos , Mastectomía Segmentaria/métodos , Colgajos Quirúrgicos , Adulto , Anciano , Axila , Femenino , Humanos , Márgenes de Escisión , Persona de Mediana Edad , Recurrencia Local de Neoplasia/cirugía , Estudios Retrospectivos
5.
J Mech Behav Biomed Mater ; 88: 41-47, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30125786

RESUMEN

Meniscectomy significantly change the kinematics of the knee joint by reducing the contact area between femoral condyles and the tibial plateau, but the shift in the contact area has been poorly described. The aim of our investigation was to measure the shift of the tibiofemoral contact area occurring after meniscectomy. We used laser scans combined to surface texturing for measuring the 3D position and area of the femoral and tibial surfaces involved in the joint. In particular, natural condyles (porcine model) were analysed and the reverse engineering approach was used for the interpretation of the results from compression tests and local force measurements in conjunction with staining techniques. The results suggested that laser scans combined to surface texturing may be considered as a powerful tool to investigate the stained contours of the contact area. Beside the largely documented reduction of contact area and local pressure increase, a shift of the centroid of the contact area toward the intercondylar notch was measured after meniscectomy. As a consequence of the contact area shift and pressure increase, cartilage degeneration close to the intercondylar notch may occur.


Asunto(s)
Fémur/cirugía , Rayos Láser , Fenómenos Mecánicos , Meniscectomía , Tibia/cirugía , Animales , Fenómenos Biomecánicos , Propiedades de Superficie
6.
Materials (Basel) ; 11(5)2018 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-29735896

RESUMEN

A computer-aided design (CAD)-based approach and sol-gel chemistry were used to design a multilayer dental post with a compositional gradient and a Young’s modulus varying from 12.4 to 2.3 GPa in the coronal-apical direction. Specifically, we propose a theoretical multilayer post design, consisting of titanium dioxide (TiO2) and TiO2/poly(ε-caprolactone) (PCL) hybrid materials containing PCL up to 24% by weight obtained using the sol-gel method. The current study aimed to analyze the effect of the designed multilayer dental post in endodontically treated anterior teeth. Stress distribution was investigated along and between the post and the surrounding structures. In comparison to a metal post, the most uniform distributions with lower stress values and no significant stress concentration were found when using the multilayer post.

7.
Eur J Orthod ; 40(6): 592-596, 2018 11 30.
Artículo en Inglés | MEDLINE | ID: mdl-29726936

RESUMEN

Objectives: To evaluate the association between maxillary dental arch transverse dimensions, palatal depths, palatal area and volume with buccally displaced canine (BDC) in mixed dentition subjects when compared to non-BDC subjects using laser scanner 3D technology. Materials and methods: Sixty Caucasian subjects, 8-11 years of age (mean, 9.26 ± 1.48 years), were included. In each group (BDC and non-BDC) 30 children were matched. Digital dental casts were obtained using a 3 Shape D700 laser scanner. Intercanine and intermolar widths (cusp and gingival levels), anterior and posterior palatal depth (cusp level), palatal surface area and volume were measured. An independent sample Student's t-test and an ANOVA were undertaken with significance level set as P < 0.05. Results: Intercanine widths at the cusp (1.76 mm; P = 0.020) and the gingival level (1.6 mm; P = 0.006), palatal area (133 mm2; P = 0.021) and volume (790 mm3; P = 0.046) were significantly lower in the BDC compared to the control group. Limitations: A smaller part of the subjects was in late mixed dentition phase. To overcome this limitation a matched control group was used. Some subjects did not have some teeth because of the transition phase which might have had an influence on the dental measurements. However, these subjects were not excluded to avoid introducing a bias. Conclusions: 3D evaluation of the maxillary arch and palate highlighted significant differences between BDC and non-BDC mixed dentition subjects. Maxillary dental arch dimensions and palate morphology may allow early identification and prevention of maxillary canine impaction.


Asunto(s)
Diente Canino/patología , Arco Dental/patología , Hueso Paladar/patología , Diente Impactado/patología , Estudios de Casos y Controles , Moldes Quirúrgicos , Niño , Diente Canino/diagnóstico por imagen , Arco Dental/diagnóstico por imagen , Dentición Mixta , Femenino , Humanos , Imagenología Tridimensional , Masculino , Maxilar/diagnóstico por imagen , Maxilar/patología , Odontometría/métodos , Hueso Paladar/diagnóstico por imagen , Diente Impactado/diagnóstico por imagen
8.
Dent Mater ; 34(7): 1063-1071, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29703402

RESUMEN

OBJECTIVES: To assess conceptual designs of dental posts consisting of polyetherimide (PEI) reinforced with carbon (C) and glass (G) glass fibers in endodontically treated anterior teeth. METHODS: 3D tessellated CAD and geometric models of endodontically treated anterior teeth were generated from Micro-CT scan images. Model C-G/PEI composite posts with different Young's moduli were analyzed by Finite Element (FE) methods post A (57.7GPa), post B (31.6GPa), post C (from 57.7 to 9.0GPa in the coronal-apical direction). A load of 50N was applied at 45° to the longitudinal axis of the tooth, acting on the palatal surface of the crown. The maximum principal stress distribution was determined along the post and at the interface between the post and the surrounding structure. RESULTS: Post C, with Young's modulus decreasing from 57.7 to 9.0GPa in the coronal-apical direction, reduced the maximum principal stress distribution in the restored tooth. Post C gave reduced stress and the most uniform stress distribution with no stress concentration, compared to the other C-G/PEI composite posts. SIGNIFICANCE: The FE analysis confirmed the ability of the functionally graded post to dissipate stress from the coronal to the apical end. Hence actual (physical) C-G/PEI posts could permit optimization of stress distributions in endodontically treated anterior teeth.


Asunto(s)
Resinas Compuestas/química , Polímeros/química , Técnica de Perno Muñón , Diente no Vital , Fibra de Carbono/química , Diseño Asistido por Computadora , Materiales Dentales/química , Diseño de Prótesis Dental , Análisis del Estrés Dental , Módulo de Elasticidad , Análisis de Elementos Finitos , Vidrio/química , Humanos , Imagenología Tridimensional , Técnicas In Vitro , Microtomografía por Rayos X
9.
Materials (Basel) ; 11(4)2018 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-29584683

RESUMEN

Over the last three decades, it has been frequently reported that the properties of dental restorative composites cured with argon laser are similar or superior to those achieved with conventional halogen and light emitting diode (LED) curing units. Whereas laser curing is not dependent on the distance between the curing unit and the material, such distance represents a drawback for conventional curing units. However, a widespread clinical application of this kind of laser remains difficult due to cost, heavy weight, and bulky size. Recently, with regard to the radiation in the blue region of the spectrum, powerful solid-state lasers have been commercialized. In the current research, CAD (computer-aided design)/CAM (computer-aided manufacturing) assisted solid-state lasers were employed for curing of different dental restorative composites consisting of micro- and nanoparticle-reinforced materials based on acrylic resins. Commercial LED curing units were used as a control. Temperature rise during the photopolymerisation process and bending properties were measured. By providing similar light energy dose, no significant difference in temperature rise was observed when the two light sources provided similar intensity. In addition, after 7 days since curing, bending properties of composites cured with laser and LED were similar. The results suggested that this kind of laser would be suitable for curing dental composites, and the curing process does not suffer from the tip-to-tooth distance.

10.
Materials (Basel) ; 11(2)2018 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-29466299

RESUMEN

Experimental/theoretical analyses have already been performed on poly(ε-caprolactone) (PCL) loaded with organic-inorganic fillers (PCL/TiO2 and PCL/ZrO2) to find a correlation between the results from the small punch test and Young's modulus of the materials. PCL loaded with Ti2 (PCL = 12, TiO2 = 88 wt %) and Zr2 (PCL = 12, ZrO2 = 88 wt %) hybrid fillers showed better performances than those obtained for the other particle composition. In this context, the aim of current research is to provide further insight into the mechanical properties of PCL loaded with sol-gel-synthesized organic-inorganic hybrid fillers for bone tissue engineering. For this reason, theoretical analyses were performed by the finite element method. The results from the small punch test and Young's modulus of the materials were newly correlated. The obtained values of Young's modulus (193 MPa for PCL, 378 MPa for PCL/Ti2 and 415 MPa for PCL/Zr2) were higher than those obtained from a previous theoretical modelling (144 MPa for PCL, 282 MPa for PCL/Ti2 and 310 MPa for PCL/Zr2). This correlation will be an important step for the evaluation of Young's modulus, starting from the small punch test data.

11.
Dent Mater ; 33(1): e39-e47, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27890355

RESUMEN

OBJECTIVE: To study the influence of the different class II mesio-occlusal-distal (MOD) cavity shape on the stress and strain distributions in adhesive indirect restorations, using numerical finite element analysis (FEA). To investigate the relationship between restored teeth failure and stiffness of food, three values of Young's modulus were used for the food. METHODS: A 3D model of a sound lower molar and three class II MOD cavities with different shape were created. Slide-type contact elements were used between tooth surface and food. An adhesive resin-based cement, modeled with fixed-type contact elements, and a single restorative filling materials were considered. To simulate polymerization shrinkage effect, which is basically restricted to the thin composite cement layer, shell elements were employed and the thermal expansion approach was used. A vertical occlusal load of 600N was applied, while assigning fixed zero-displacements on the cutting surfaces below the crevices. All the materials were assumed to be isotropic and elastic. A static linear analysis was carried out. RESULTS: In the lingual cusp, the displacements increased as the values of the stiffness food increased. In the restored teeth, the stress near the restoration-tooth interface was strongly dependent on the MOD cavity shape. The stress peaks were mainly located along the enamel-dentin interface at the lingual side; wedge-shaped MOD cavity with a low angle, in combination with the lowest food stiffness provided the best results. SIGNIFICANCE: A more complex load application on the occlusal surfaces was introduced. Food stiffness slightly affected the stress distribution of the restored and sound teeth. Teeth with adhesive class II MOD indirect resin composite restorations were potentially more susceptible to damage if the class II MOD cavity-margin-angle was higher than 95°. Restored teeth with a higher cavity-margin-angle led to considerable stress concentration in the lingual cusp along the enamel-dentin interface. These models were more susceptible to fracture in the lingual cusps when compared to the buccal ones.


Asunto(s)
Preparación de la Cavidad Dental , Restauración Dental Permanente , Análisis del Estrés Dental , Resinas Compuestas , Materiales Dentales , Análisis de Elementos Finitos , Cementos de Resina , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...