Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Pharmaceutics ; 16(4)2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38675208

RESUMEN

Electroporation (EP) stands out as a promising non-viral plasmid delivery strategy, although achieving optimal transfection efficiency in vivo remains a challenge. A noteworthy advancement in the field of in vivo EP is the application of hyaluronidase, an enzyme with the capacity to degrade hyaluronic acid in the extracellular matrix, which thereby enhances DNA transfer efficiency by 2- to 3-fold. This paper focuses on elucidating the mechanism of hyaluronidase's impact on transfection efficiency. We demonstrate that hyaluronidase promotes a more uniform distribution of plasmid DNA (pDNA) within skeletal muscle. Additionally, our study investigates the effect of the timing of hyaluronidase pretreatment on EP efficiency by including time intervals of 0, 5, and 30 min between hyaluronidase treatment and the application of pulses. Serum levels of the pDNA-encoded transgene reveal a minimal influence of the hyaluronidase pretreatment time on the final serum protein levels following delivery in both mice and rabbit models. Leveraging bioimpedance measurements, we capture morphological changes in muscle induced by hyaluronidase treatment, which result in a varied pDNA distribution. Subsequently, these findings are employed to optimize EP electrical parameters following hyaluronidase treatment in animal models. This paper offers novel insights into the potential of hyaluronidase in enhancing the effectiveness of in vivo EP, as well as guides optimized electroporation strategies following hyaluronidase use.

2.
Lab Chip ; 21(6): 1036-1048, 2021 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-33666615

RESUMEN

Alterations in the deformability of red blood cells (RBCs), occurring in hemolytic blood disorders such as sickle cell disease (SCD), contribute to vaso-occlusion and disease pathophysiology. There are few functional in vitro assays for standardized assessment of RBC-mediated microvascular occlusion. Here, we present the design, fabrication, and clinical testing of the Microfluidic Impedance Red Cell Assay (MIRCA) with embedded capillary network-based micropillar arrays and integrated electrical impedance measurement electrodes to address this need. The micropillar arrays consist of microcapillaries ranging from 12 µm to 3 µm, with each array paired with two sputtered gold electrodes to measure the impedance change of the array before and after sample perfusion through the microfluidic device. We define RBC occlusion index (ROI) and RBC electrical impedance index (REI), which represent the cumulative percentage occlusion and cumulative percentage impedance change, respectively. We demonstrate the promise of MIRCA in two common red cell disorders, SCD and hereditary spherocytosis. We show that the electrical impedance measurement reflects the microvascular occlusion, where REI significantly correlates with ROI that is obtained via high-resolution microscopy imaging of the microcapillary arrays. Further, we show that RBC-mediated microvascular occlusion, represented by ROI and REI, associates with clinical treatment outcomes and correlates with in vivo hemolytic biomarkers, lactate dehydrogenase (LDH) level and absolute reticulocyte count (ARC) in SCD. Impedance measurement obviates the need for high-resolution imaging, enabling future translation of this technology for widespread access, portable and point-of-care use. Our findings suggest that the presented microfluidic design and the integrated electrical impedance measurement provide a reproducible functional test for standardized assessment of RBC-mediated microvascular occlusion. MIRCA and the newly defined REI may serve as an in vitro therapeutic efficacy benchmark for assessing the clinical outcome of emerging RBC-modifying targeted and curative therapies.


Asunto(s)
Anemia de Células Falciformes , Microfluídica , Impedancia Eléctrica , Recuento de Eritrocitos , Eritrocitos , Humanos
3.
Thromb Haemost ; 121(1): 58-69, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32877954

RESUMEN

BACKGROUND: There are acute settings where assessing the anticoagulant effect of direct oral anticoagulants (DOACs) can be useful. Due to variability among routine coagulation tests, there is an unmet need for an assay that detects DOAC effects within minutes in the laboratory or at the point of care. METHODS: We developed a novel dielectric microsensor, termed ClotChip, and previously showed that the time to reach peak permittivity (T peak) is a sensitive parameter of coagulation function. We conducted a prospective, single-center, pilot study to determine its clinical utility at detecting DOAC anticoagulant effects in whole blood. RESULTS: We accrued 154 individuals: 50 healthy volunteers, 49 rivaroxaban patients, 47 apixaban, and 8 dabigatran patients. Blood samples underwent ClotChip measurements and plasma coagulation tests. Control mean T peak was 428 seconds (95% confidence interval [CI]: 401-455 seconds). For rivaroxaban, mean T peak was 592 seconds (95% CI: 550-634 seconds). A receiver operating characteristic curve showed that the area under the curve (AUC) predicting rivaroxaban using T peak was 0.83 (95% CI: 0.75-0.91, p < 0.01). For apixaban, mean T peak was 594 seconds (95% CI: 548-639 seconds); AUC was 0.82 (95% CI: 0.73-0.91, p < 0.01). For dabigatran, mean T peak was 894 seconds (95% CI: 701-1,086 seconds); AUC was 1 (p < 0.01). Specificity for all DOACs was 88%; sensitivity ranged from 72 to 100%. CONCLUSION: This diagnostic study using samples from "real-world" DOAC patients supports that ClotChip exhibits high sensitivity at detecting DOAC anticoagulant effects in a disposable portable platform, using a miniscule amount of whole blood (<10 µL).


Asunto(s)
Pruebas de Coagulación Sanguínea/instrumentación , Monitoreo de Drogas/instrumentación , Inhibidores del Factor Xa/uso terapéutico , Anciano , Anciano de 80 o más Años , Coagulación Sanguínea/efectos de los fármacos , Pruebas de Coagulación Sanguínea/métodos , Dabigatrán/farmacología , Dabigatrán/uso terapéutico , Monitoreo de Drogas/métodos , Diseño de Equipo , Inhibidores del Factor Xa/farmacología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pirazoles/farmacología , Pirazoles/uso terapéutico , Piridonas/farmacología , Piridonas/uso terapéutico , Rivaroxabán/farmacología , Rivaroxabán/uso terapéutico
4.
Haemophilia ; 25(5): 885-892, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31282024

RESUMEN

BACKGROUND: Reliable monitoring of coagulation factor replacement therapy in patients with severe haemophilia, especially those with inhibitors, is an unmet clinical need. While useful, global assays, eg thromboelastography (TEG), rotational thromboelastometry (ROTEM) and thrombin generation assay (TGA), are cumbersome to use and not widely available. OBJECTIVE: To assess the utility of a novel, point-of-care, dielectric microsensor - ClotChip - to monitor coagulation factor replacement therapy in patients with haemophilia A, with and without inhibitors. METHODS: The ClotChip Tpeak parameter was assessed using whole-blood samples from children with severe haemophilia A, with (n = 6) and without (n = 12) inhibitors, collected pre- and postcoagulation factor replacement therapy. ROTEM, TGA and chromogenic FVIII assays were also performed. Healthy children (n = 50) served as controls. RESULTS: ClotChip Tpeak values exhibited a significant decrease for samples collected postcoagulation factor replacement therapy as compared to baseline (pretherapy) samples in patients with and without inhibitors. A difference in Tpeak values was also noted at baseline among severe haemophilia A patients with inhibitors as compared to those without inhibitors. ClotChip Tpeak parameter exhibited a very strong correlation with clotting time (CT) of ROTEM, endogenous thrombin potential (ETP) and peak thrombin of TGA, and FVIII clotting activity. CONCLUSIONS: ClotChip is sensitive to coagulation factor replacement therapy in patients with severe haemophilia A, with and without inhibitors. ClotChip Tpeak values correlate very well with ROTEM, TGA and FVIII assays, opening up possibilities for its use in personalized coagulation factor replacement therapy in haemophilia.


Asunto(s)
Pruebas de Coagulación Sanguínea/métodos , Espectroscopía Dieléctrica/métodos , Hemofilia A/terapia , Sistemas de Atención de Punto/normas , Femenino , Humanos , Masculino
5.
IEEE Trans Biomed Circuits Syst ; 11(6): 1459-1469, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28920906

RESUMEN

This paper describes the design, fabrication, and testing of a microfluidic sensor for dielectric spectroscopy of human whole blood during coagulation. The sensor, termed ClotChip, employs a three-dimensional, parallel-plate, capacitive sensing structure with a floating electrode integrated into a microfluidic channel. Interfaced with an impedance analyzer, the ClotChip measures the complex relative dielectric permittivity, ϵr , of human whole blood in the frequency range of 40 Hz to 100 MHz. The temporal variation in the real part of the blood dielectric permittivity at 1 MHz features a time to reach a permittivity peak, , as well as a maximum change in permittivity after the peak, , as two distinct parameters of ClotChip readout. The ClotChip performance was benchmarked against rotational thromboelastometry (ROTEM) to evaluate the clinical utility of its readout parameters in capturing the clotting dynamics arising from coagulation factors and platelet activity. exhibited a very strong positive correlation ( r = 0.99, p < 0.0001) with the ROTEM clotting time parameter, whereas exhibited a strong positive correlation (r = 0.85,  p < 0.001) with the ROTEM maximum clot firmness parameter. This paper demonstrates the ClotChip potential as a point-of-care platform to assess the complete hemostatic process using <10 µL of human whole blood.


Asunto(s)
Técnicas Biosensibles/métodos , Microfluídica/métodos , Sistemas de Atención de Punto , Femenino , Humanos , Masculino
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 291-294, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28268334

RESUMEN

This paper describes the design and construct of a fully biocompatible, microfluidic, dielectric sensor targeted at monitoring human whole blood coagulation at the point-of-care (POC). The sensor assembly procedure involves using sputtered electrodes in a microfluidic channel with a physiologically relevant height of 50µm to create a three-dimensional (3D), parallel-plate, capacitive sensing area. The sensor is constructed with biocompatible materials of polymethyl methacrylate (PMMA) for the substrate and titanium nitride (TiN) for the sensing and floating electrodes. The real part of the complex relative dielectric permittivity of human whole blood is measured from 10kHz to 100MHz using an impedance analyzer and under static conditions. The temporal variation in dielectric permittivity at 1MHz for human whole blood undergoing coagulation shows a peak in permittivity at 5 minutes, which closely matches our previously established results. This sensor can pave the way for monitoring blood coagulation under physiologically relevant shear flow rates in the future.


Asunto(s)
Coagulación Sanguínea/fisiología , Electricidad , Microfluídica/instrumentación , Microfluídica/métodos , Sistemas de Atención de Punto , Polimetil Metacrilato/química , Electrodos , Humanos , Factores de Tiempo , Titanio/química
7.
Artículo en Inglés | MEDLINE | ID: mdl-26737635

RESUMEN

This paper reports on the design, fabrication, and testing of a microfluidic sensor for dielectric spectroscopy (DS) of human whole blood during coagulation. The sensor employs a three-dimensional (3D), parallel-plate, capacitive sensing structure with a floating electrode integrated into a microfluidic channel. Using an impedance analyzer and after a 5-point calibration, the sensor is shown to measure the real part of complex relative dielectric permittivity of human whole blood in a frequency range of 10kHz to 100MHz. The temporal variation of dielectric permittivity at 1MHz for human whole blood from three different healthy donors shows a peak in permittivity at ~ 4 to 5 minutes, which also corresponds to the onset of CaCl2-initiated coagulation of the blood sample verified visually.


Asunto(s)
Coagulación Sanguínea/fisiología , Espectroscopía Dieléctrica/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Diseño de Equipo , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA