Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38881205

RESUMEN

This study was conducted as a single-site, open-label, randomized, replicated crossover trial with 4 treatment periods. The aim was to evaluate the bioequivalence of a generic test drug containing velpatasvir and sofosbuvir compared to an established brand-name medication in healthy White subjects under fasting conditions. Blood samples were collected at specified intervals up to 72 hours after dosing to measure the concentrations of velpatasvir and sofosbuvir using a certified high-performance liquid chromatography with tandem mass spectrometry method. The bioequivalence of the 2 formulations was confirmed when statistical analysis showed that confidence intervals for the log-transformed peak concentration and area under the concentration-time curve from time 0 to the last quantifiable sample were within an acceptable range from 80% to 125%. Criteria for bioequivalence were met for both area under the concentration-time curve from time 0 until the last quantifiable sample and peak concentration parameters. No adverse effects were reported during this trial in both groups.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38515279

RESUMEN

The aim of the study was to compare the pharmacokinetics (PK) and pharmacodynamics (PD) of T-glu (GP40321, test drug), and reference insulin glulisine in a hyperinsulinemic-euglycemic clamp procedure. During this study, 34 healthy male volunteers underwent the hyperinsulinemic-euglycemic clamp procedure following subcutaneous 0.3 U/kg injection of T-glu or reference insulin glulisine in a randomized, double-blind, crossover study. Plasma glucose levels were monitored every 5 minutes for 8 hours. Glucose infusion rate adjustment was based on the blood glucose measurements. Evaluation of PD was performed using the glucose infusion rate values, while PK was calculated using insulin concentrations measured via enzyme-linked immunosorbent assay. The study results showed that the 90% CI for the geometric mean ratios of primary PK and PD of T-glu and reference insulin glulisine were within 80%-125% comparability limits, and that the safety profiles were comparable. PK, PD, and safety similarity of T-glu and reference insulin glulisine was demonstrated.

3.
Clin Pharmacol Drug Dev ; 13(4): 419-431, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38168134

RESUMEN

GP40141 is a romiplostim biosimilar. A Phase 1 clinical trial was previously conducted in healthy volunteers to evaluate the pharmacodynamics (PD), pharmacokinetics (PK), and safety of GP40141 compared to the reference romiplostim (NCT05652595). Using noncompartmental analysis, the biosimilarity of PD end points was determined according to the classical criterion (0.8-1.25). PK end points were also in good agreement between GP40141 and the reference romiplostim; however, the confidence interval for the area under concentration-time curve from time 0 to the time of last measurement was slightly out of the bioequivalence range (0.91-1.29). Population PK/PD was used in the present study to characterize the individual PK and PD data of 56 healthy subjects in 2 cross-over periods of the Phase 1 clinical trial. Body weight and neutralizing antibodies to romiplostim were found to be important predictors of apparent volume of distribution and linear elimination constant, respectively. Within the framework of the conducted modeling, population estimates of PK/PD parameters were obtained, which were in agreement with literature data for the reference romiplostim. Additionally, values of intersubject variability, previously unreported for romiplostim in a healthy subject population, were derived. Covariate analysis, conducted during model development, as well as visual diagnostics and model-based simulations, demonstrated the absence of significant differences in PK and PD between GP40141 and romiplostim-ref.


Asunto(s)
Biosimilares Farmacéuticos , Proteínas Recombinantes de Fusión , Humanos , Voluntarios Sanos , Biosimilares Farmacéuticos/farmacocinética , Trombopoyetina , Receptores Fc
4.
Clin Pharmacol Drug Dev ; 12(12): 1178-1184, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37728234

RESUMEN

Biphasic insulin aspart 30 is a premixed formulation containing a soluble fraction of insulin aspart (30%) and a protamine-crystallized fraction (70%) that was developed to combine the rapid-acting and prolonged advantages of commercially available insulins. The aim of this bioequivalence study was to compare the pharmacokinetics (PKs) of GP-bi-asp and Novo-bi-asp, and evaluate the pharmacodynamic (PD) properties as well as the safety of these drugs in the hyperinsulinemic euglycemic clamp (HEC) procedure. This was a phase 1, randomized, double-blind, 2-sequence, 2-period crossover study. Thirty-four male volunteers who met the inclusion criteria underwent the HEC procedure following a single subcutaneous injection of 0.4 IU/kg of either GP-bi-asp or Novo-bi-asp in the abdomen. After the treatment, the subjects' plasma glucose levels were monitored for 24 hours and the glucose infusion rate (GIR) was adjusted to maintain the target blood glucose level. The PD parameters were calculated using GIR values. Insulin aspart concentrations were measured in blood plasma using validated ELISA assays to evaluate the PK parameters of the investigated drugs. The 90% confidence intervals for the geometric mean ratios of PK (Cins and AUCins-T ) parameters of Gp-bi-asp and Novo-bi-asp were close to 100% and within the 80%-125% limits for establishing bioequivalence. The safety profiles of both drugs were also comparable.


Asunto(s)
Biosimilares Farmacéuticos , Insulinas Bifásicas , Masculino , Humanos , Insulina Aspart/efectos adversos , Insulina Aspart/farmacocinética , Hipoglucemiantes , Biosimilares Farmacéuticos/efectos adversos , Equivalencia Terapéutica , Estudios Cruzados , Glucosa
5.
Pharmacol Res Perspect ; 11(5): e01125, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37740581

RESUMEN

AIMS: The pharmacodynamic (PD) similarity between GP40141, a proposed romiplostim biosimilar, and reference romiplostim was evaluated. Pharmacokinetics and safety were also assessed. METHODS: In this phase 1, randomized, double-blind, single-dose, crossover comparative study with an adaptive design, 56 healthy male volunteers were randomized 1:1 to receive a 3 ug × kg-1 subcutaneous dose of GP40141 and reference romiplostim. The PD similarity between GP40141 and the reference romiplostim was determined using the standard equivalence criteria (80%-125%) for the area under the platelet count-time curve from time 0 to the time of the last sampling for PD (AUCplt ) and the maximum observed platelet count (Pmax ). RESULTS: GP40141 and the reference romiplostim exhibited similar PD profiles. 90% CI for the geometric mean ratios for the primary PD parameters (AUCplt, Pmax ) for GP40141 (T) and the reference romiplostim (R) were fully contained within the predefined equivalence limits of 80%-125%: 98.13%-102.42% for AUCplt and 97.56%-105.80% for Pmax . The pharmacokinetic profiles of GP40141 and the reference romiplostim were well described. No adverse events were observed during the clinical trial after the administration of GP40141 and the reference romiplostim. CONCLUSION: This study demonstrates the PD similarity of GP40141 to the reference romiplostim. Both treatments had comparable safety profiles (NCT05652595).


Asunto(s)
Biosimilares Farmacéuticos , Humanos , Masculino , Biosimilares Farmacéuticos/efectos adversos , Método Doble Ciego , Proteínas Recombinantes de Fusión/efectos adversos , Voluntarios Sanos
6.
Biologicals ; 81: 101666, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36871442

RESUMEN

The results of preclinical studies of romiplostim analogue GP40141 are presented. The effect of a cell proliferation, phosphorylation of the TPO receptor and JAK2 phosphorylation were studied in the presence of romiplostim and in the presence of GP40141 in a cell line of mice (Mus musculus) lymphoblasts with stable expression of human TPO receptor 32D-hTPOR clone 63. Binding to the TPO receptor and to the neonatal Fc receptor (FcRn) was examined for both romiplostim and the developed analogue. In Sprague-Dawley rats, the dynamics of platelet count after the administration of romiplostim or GP40141 were determined. The pharmacokinetics of romiplostim and GP40141, as well as the dynamics of platelet count, were studied in cynomolgus monkeys. The serum concentrations of romiplostim were determined using a modified colorimetric enzyme-linked immunosorbent assay (ELISA). The data obtained allow us to assert the similarity of the biological action of Nplate® and GP40141.


Asunto(s)
Biosimilares Farmacéuticos , Púrpura Trombocitopénica Idiopática , Ratas , Humanos , Ratones , Animales , Ratas Sprague-Dawley , Recuento de Plaquetas , Trombopoyetina/farmacocinética , Receptores Fc , Proteínas Recombinantes de Fusión/farmacología , Macaca fascicularis
7.
J Comp Eff Res ; 11(18): 1337-1347, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36511777

RESUMEN

Aim: To evaluate the safety and efficacy of insulin Aspart-Mix biosimilar candidate GP40081 (GP-Asp30) compared with NovoMix® 30 (NN-Asp30). Materials & methods: In a randomized open-label, active-controlled, 26-week non-inferiority clinical trial 264 patients with Type 2 diabetes mellitus were randomized 1:1 to receive once-daily GP-Asp30 or NN-Asp30. The primary safety end point was the immune response rate. Efficacy outcomes were a mean change in HbA1c (primary), frequency of achieving a glycemic g fasting plasma glucose levels, 7-point glucose profiles, and insulin doses. Results: The immune response developed in 10/126 (8%) participants in the GP-Asp30 group and in 10/125 (8%) participants in the NN-Asp30 group (p = 1.000). The mean difference in HbA1c change between groups was 0.12 (95%CI [-0.14, 0.38]). Other secondary efficacy and safety outcomes weren't statistically different between the two groups. Conclusion: GP-Asp30 demonstrated similar safety and efficacy compared with NN-Asp30 and may be considered a biosimilar insulin.


Asunto(s)
Biosimilares Farmacéuticos , Diabetes Mellitus Tipo 2 , Hipoglucemiantes , Insulina Aspart , Humanos , Biosimilares Farmacéuticos/uso terapéutico , Insulinas Bifásicas , Glucemia , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hemoglobina Glucada , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Insulina Aspart/uso terapéutico , Insulina Isófana
8.
Clin Pharmacol Drug Dev ; 11(12): 1457-1466, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35980375

RESUMEN

This paper presents an analysis of data from a comparative study of biosimilarity in terms of pharmacokinetics and pharmacodynamics in healthy volunteers using a hyperinsulinemic euglycemic clamp for reference and test biphasic insulin aspart 30 (BIAsp 30). As a result of the study, one of the secondary pharmacodynamic (PD) endpoints did not satisfy the classical criterion of 80%-125% (the lower limit for PD parameter area under the glucose infusion rate-time curve [ AUC GIR 0 - t ${\rm{AUC}}_{{\rm{GIR}}_{0 - {\rm{t}}}}$ ] turned out to be 79.5%). The main hypothesis explaining this result is that the sample size is insufficient to conduct a PD test with 90% statistical power, since the sample size has been calculated based on the coefficient of variation (CV) of pharmacokinetic (PK) parameters. To test this hypothesis, population PKPD (popPKPD) modeling and subsequent simulations of the required number of PD profiles were used. Two popPKPD models were constructed (a one-compartment double simultaneous absorption model for PK and an effect compartment Emax model for PD) to describe the PKPD data of reference and test insulins. As a result, using real data along with model-based simulation data, a biosimilarity test for PD was performed, and the lower limit for AUC GIR 0 - t ${\rm{AUC}}_{{\rm{GIR}}_{0 - {\rm{t}}}}$ became 82.6%, while the CV decreased from 31.7% to 24.1%. Thus, popPKPD modeling and simulations have been shown to be effective in interpreting and supporting the results of clinical biosimilarity trials.


Asunto(s)
Biosimilares Farmacéuticos , Humanos , Hipoglucemiantes/farmacocinética , Método Doble Ciego , Estudios Cruzados
9.
Clin Pharmacol Drug Dev ; 11(8): 922-929, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35230749

RESUMEN

Insulin aspart is a short-acting insulin analogue that is used to control postprandial glycemia levels in diabetic patients. The aim of this clinical trial was to compare the pharmacokinetics and pharmacodynamics of GP40071 (GP-Asp) and NovoRapid Penfill (Novo-Asp) in a hyperinsulinemic euglycemic clamp (HEC). This trial was conducted as a part of a GP40071 biosimilar clinical development program. This was a phase I randomized, double-blind, two-period crossover study. Twenty-six healthy male volunteers aged 18 to 45 years who met the inclusion criteria underwent the procedure of an HEC following a single subcutaneous injection of 0.3 IU/kg of either GP-Asp or Novo-Asp into the abdomen. After doses, plasma glucose levels were monitored every 5 minutes for 8 hours. The adjustment of the glucose infusion rate (GIR) was based on the blood glucose measurements. The GIR values were used to evaluate the PD profiles of the studied drugs. Regular blood sampling was performed during the study to obtain sufficient pharmacokinetic data. The 90% confidence intervals for the geometric mean ratios of the pharmacokinetic (AUCins.0-t , Cins.max ) and pharmacodynamic (GIRmax , AUCGIR0-t ) parameters of GP-Asp were within the 80%-125% comparability limits. The safety profiles of the drugs were also comparable. Bioequivalence, similar PD, and safety of GP-Asp and Novo-Asp were demonstrated.


Asunto(s)
Biosimilares Farmacéuticos , Insulina Aspart , Biosimilares Farmacéuticos/farmacología , Estudios Cruzados , Glucosa , Técnica de Clampeo de la Glucosa , Humanos , Hipoglucemiantes/farmacocinética , Insulina Aspart/farmacocinética , Masculino
10.
J Clin Pharmacol ; 62(9): 1086-1093, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35320591

RESUMEN

This study includes modeling and simulation of insulin aspart pharmacokinetics (PK). The authors used PK data of biosimilar insulins-insulin aspart and biphasic insulin aspart 30/70-to develop a predictive population PK model for the insulins. The model was built via Monolix software, taking into account the weight-based dosing and the dose and body-weight effects on the parameters. The model-based simulations were performed using the R package mlxR for various administered doses and various ratios of insulin aspart forms for a better understanding of the insulin behavior. The optimal model was a 1-compartment model with a combination of zero- and first-order absorptions, with absorption lag for the soluble form of insulin aspart and first-order absorption for the insulin aspart protamine suspension. The assumption of identical behavior of 2 insulins at the distribution and elimination phases was made. The developed PK model was fitted successfully to the experimental data, and all fitted parameters displayed a moderate coefficient of variation. The PK model allows us to predict PK profiles for various doses and formulations of insulin aspart and can be used to improve the accuracy, safety, and ethics of novel clinical trials of insulin.


Asunto(s)
Insulinas , Insulinas Bifásicas/farmacocinética , Insulinas Bifásicas/uso terapéutico , Glucemia , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Humanos , Hipoglucemiantes , Insulina , Insulina Aspart/farmacocinética , Insulina Aspart/uso terapéutico , Insulina Isófana , Insulinas/farmacocinética
11.
PLoS One ; 16(7): e0254493, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34260655

RESUMEN

This study was the first to compare the neuroprotective activity of Cerebrolysin®, Actovegin® and Cortexin® in rodent models of acute and chronic brain ischemia. The neuroprotective action was evaluated in animals with acute (middle cerebral artery occlusion) or chronic (common carotid artery stenosis) brain ischemia models in male rats. Cortexin® (1 or 3 mg/kg/day), Cerebrolysin® (538 or 1614 mg/kg/day) and Actovegin® (200 mg/kg/day) were administered for 10 days. To assess the neurological and motor impairments, open field test, adhesive removal test, rotarod performance test and Morris water maze test were performed. Brain damage was assessed macro- and microscopically, and antioxidant system activity was measured in brain homogenates. In separate experiments in vitro binding of Cortexin® to a wide panel of receptors was assessed, and blood-brain barrier permeability of Cortexin® was assessed in mice in vivo. Cortexin® or Cerebrolysin® and, to a lesser extent, Actovegin® improved the recovery of neurological functions, reduced the severity of sensorimotor and cognitive impairments in rats. Cortexin® reduced the size of necrosis of brain tissue in acute ischemia, improved functioning of the antioxidant system and prevented the development of severe neurodegenerative changes in chronic ischemia model. Radioactively labeled Cortexin® crossed the blood-brain barrier in mice in vivo with concentrations equal to 6-8% of concentrations found in whole blood. During in vitro binding assay Cortexin® (10 µg/ml) demonstrated high or moderate binding to AMPA-receptors (80.1%), kainate receptors (73.5%), mGluR1 (49.0%), GABAA1 (44.0%) and mGluR5 (39.7%), which means that effects observed in vivo could be related on the glutamatergic and GABAergic actions of Cortexin®. Thus, Cortexin, 1 or 3 mg/kg, or Cerebrolysin®, 538 or 1614 mg/kg, were effective in models acute and chronic brain ischemia in rats. Cortexin® contains compounds acting on AMPA, kainate, mGluR1, GABAA1 and mGluR5 receptors in vitro, and readily crosses the blood-brain barrier in mice.


Asunto(s)
Aminoácidos , Isquemia Encefálica , Hemo/análogos & derivados , Péptidos y Proteínas de Señalización Intercelular , Animales , Masculino , Ratones , Fármacos Neuroprotectores , Ratas
12.
J Comp Eff Res ; 10(1): 55-66, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33355484

RESUMEN

Aim: To compare safety (immunogenicity) and efficacy of a biosimilar insulin GP-Lis25 and a reference insulin Ly-Lis25 (Humalog Mix 25) in Type 2 diabetes mellitus (T2D) patients. Materials & methods: This randomized open-label, 26-week clinical trial enrolled 210 T2D patients, randomized 1:1 to twice-daily GP-Lis25 or Ly-Lis25. The primary end point was immune response at 26th week. Noninferiority margin for HbA1c was 0.4%. Results: Immune response frequency was similar in GP-Lis25 and Ly-Lis25 groups both at week 12 (p = 0.651) and 26 (p = 0.164). The difference of HbA1c change at week 26 was (95% CI) 0.01 (-0.27-0.28)%. Fasting plasma glucose, seven-point glucose profile and insulin dose were similar between groups. Safety did not differ between groups. Conclusion: GP-Lis25 and Ly-Lis25 demonstrated similar safety and efficacy. ClincalTrials.gov identifier: NCT04023344.


Asunto(s)
Diabetes Mellitus Tipo 2 , Glucemia , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hemoglobina Glucada , Humanos , Hipoglucemiantes/uso terapéutico , Insulina Glargina , Insulina Lispro/uso terapéutico
13.
J Comp Eff Res ; 9(4): 263-273, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32027167

RESUMEN

Aim: To compare safety (immunogenicity) and efficacy of GP40061 insulin glargine (GP-Gla) and Lantus® (Sanofi glargine, Sa-Gla) in people with diabetes mellitus. Materials & methods: This randomized open-label, 26-week clinical trial enrolled 180 Type 1 diabetes mellitus patients (HbA1c 6.5-12.0%), randomized 1:1 to once daily GP-Gla (n = 90) or Sa-Gla (n = 90). The primary end point was immune response at 26th week. Results: The frequency of immune response was similar in GP-Gla and Sa-Gla (p = 1.000). Groups were similar in terms of other safety end points. Mean HbA1c change from baseline was -0.66% for GP-Gla and -0.77% for Sa-Gla, and did not differ between groups (p = 0.326). Insulin doses, fasting plasma glucose and seven-point glucose profiles were similar between groups. Conclusion: GP-Gla and Sa-Gla demonstrated similar safety and efficacy. ClinicalTrials.gov Identifier: NCT04022993.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Insulina Glargina/uso terapéutico , Adulto , Glucemia/análisis , Diabetes Mellitus Tipo 1/inmunología , Femenino , Hemoglobina Glucada/análisis , Humanos , Insulina Glargina/clasificación , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...