1.
Analyst ; 148(15): 3559-3564, 2023 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-37395455

RESUMEN

This work investigates the influence of laser irradiation parameters (wavelength, power density and exposure time) on singlet oxygen (1O2) generation efficiency. Chemical trap (L-histidine) and fluorescent probe (Singlet Oxygen Sensor Green, SOSG) detection methods were used. Studies have been conducted for 1267, 1244, 1122 and 1064 nm laser wavelengths. 1267 nm had the highest efficiency of 1O2 generation, but 1064 nm demonstrated almost the same efficiency. We also observed that the 1244 nm wavelength can generate some amount of 1O2. It was demonstrated that laser exposure time can generate 1O2 more efficiently than an increase of power. Additionally, the SOSG fluorescence intensity measurements method for acute brain slices was studied. This allowed us to evaluate the approach's potential for in vivo detection of 1O2 concentrations.

2.
Front Physiol ; 10: 416, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31057417

RESUMEN

The introduction of optical non-invasive diagnostic methods into clinical practice can substantially advance in the detection of early microcirculatory disorders in patients with different diseases. This paper is devoted to the development and application of the optical non-invasive diagnostic approach for the detection and evaluation of the severity of microcirculatory and metabolic disorders in rheumatic diseases and diabetes mellitus. The proposed methods include the joint use of laser Doppler flowmetry, absorption spectroscopy and fluorescence spectroscopy in combination with functional tests. This technique showed the high diagnostic importance for the detection of disturbances in peripheral microhaemodynamics. These methods have been successfully tested as additional diagnostic techniques in the field of rheumatology and endocrinology. The sensitivity and specificity of the proposed diagnostic procedures have been evaluated.

3.
Microvasc Res ; 120: 13-20, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29802880

RESUMEN

Timely diagnostics of microcirculatory system abnormalities, which are the most severe diabetic complications, is one of the major problems facing modern health care. Functional abnormalities manifest themselves earlier than the structural ones, and therefore their assessment is the issue of primary importance. In this study Laser Doppler flowmetry, a noninvasive technique for the cutaneous blood flow monitoring, was utilized together with local temperature tests and wavelet analysis. The study of the blood flow in the microvascular bed of toes was carried out in the control group of 40 healthy subjects and in two groups of 17 type 1 and 23 type 2 diabetic patients. The local temperature tests demonstrated that the diabetic patients have impaired vasodilation in response to local heating. The tendency for impaired low frequency pulsations of the blood flow associated with endothelial and neurogenic activities in both diabetes groups was observed. Local thermal tests induced variations in perfusion and its spectral characteristics, which were different in the groups under study. In our opinion, the obtained preliminary results can be a basis for further research and provide a deeper understanding of pathological processes that drive microvascular abnormalities caused by diabetes mellitus.


Asunto(s)
Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 2/complicaciones , Pie Diabético/diagnóstico , Pie/irrigación sanguínea , Flujometría por Láser-Doppler , Microcirculación , Microvasos/fisiopatología , Adulto , Velocidad del Flujo Sanguíneo , Estudios de Casos y Controles , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 2/diagnóstico , Pie Diabético/etiología , Pie Diabético/fisiopatología , Femenino , Humanos , Hipertermia Inducida , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Vasodilatación , Análisis de Ondículas
4.
J Biomed Opt ; 22(8): 1-10, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28825287

RESUMEN

According to the International Diabetes Federation, the challenge of early stage diagnosis and treatment effectiveness monitoring in diabetes is currently one of the highest priorities in modern healthcare. The potential of combined measurements of skin fluorescence and blood perfusion by the laser Doppler flowmetry method in diagnostics of low limb diabetes complications was evaluated. Using Monte Carlo probabilistic modeling, the diagnostic volume and depth of the diagnosis were evaluated. The experimental study involved 76 patients with type 2 diabetes mellitus. These patients were divided into two groups depending on the degree of complications. The control group consisted of 48 healthy volunteers. The local thermal stimulation was selected as a stimulus on the blood microcirculation system. The experimental studies have shown that diabetic patients have elevated values of normalized fluorescence amplitudes, as well as a lower perfusion response to local heating. In the group of people with diabetes with trophic ulcers, these parameters also significantly differ from the control and diabetes only groups. Thus, the intensity of skin fluorescence and level of tissue blood perfusion can act as markers for various degrees of complications from the beginning of diabetes to the formation of trophic ulcers.


Asunto(s)
Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/fisiopatología , Extremidad Inferior/irrigación sanguínea , Supervivencia Tisular/fisiología , Estudios de Casos y Controles , Femenino , Fluorescencia , Humanos , Flujometría por Láser-Doppler , Masculino , Microcirculación/fisiología , Persona de Mediana Edad , Piel/irrigación sanguínea
5.
J Biomed Opt ; 22(7): 70501, 2017 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-28703257

RESUMEN

Laser Doppler flowmetry (LDF) has been applied for the assessment of variation in blood microflows in patients with rheumatic diseases and healthy volunteers. Oscillations of peripheral blood microcirculation observed by LDF have been analyzed utilizing a wavelet transform. A higher amplitude of blood microflow oscillations has been observed in a high frequency band (over 0.1 Hz) in patients with rheumatic diseases. Oscillations in the high frequency band decreased in healthy volunteers in response to the cold pressor test, whereas lower frequency pulsations prevailed in patients with rheumatic diseases. A higher perfusion rate at normal conditions was observed in patients, and a weaker response to cold stimulation was observed in healthy volunteers. Analysis of blood microflow oscillations has a high potential for evaluation of mechanisms of blood flow regulation and diagnosis of vascular abnormalities associated with rheumatic diseases.