3.
Ann Thorac Surg ; 2024 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-38316377

RESUMEN

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.

4.
JTCVS Open ; 17: 55-63, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38420551

RESUMEN

Background: The use of rapid-deployment valves (RDVs) has been shown to reduce the operative time for surgical aortic valve replacement (AVR). Long-term core laboratory-adjudicated data are scarce, however. Here we report final 7-year data on RDV use. Methods: TRANSFORM was a prospective, nonrandomized, multicenter, single-arm trial implanting a stented bovine pericardial valve with an incorporated balloon-expandable sealing frame. A prior published 1-year analysis included 839 patients from 29 centers. An additional 46 patients were enrolled and implanted, for a total of 885 patients. Annual clinical and core laboratory-adjudicated echocardiographic outcomes were collected through 8 years. Primary endpoints were structural valve deterioration (SVD), all-cause reintervention, all-cause valve explantation, and all-cause mortality. Secondary endpoints included hemodynamic performance assessed by echocardiography. The mean duration of follow-up was 5.0 ± 2.0 years. Results: The mean patient age was 73.3 ± 8.2 years. Isolated AVR was performed in 62.1% of the patients, and AVR with concomitant procedures was performed in 37.9%. Freedom from all-cause mortality at 7 years was 76.0% for isolated AVR and 68.2% for concomitant AVR. Freedom from SVD, all-cause reintervention, and valve explantation at 7 years was 97.5%, 95.7%, and 97.8%, respectively. The mean gradient and effective orifice area at 7 years were 11.1 ± 5.3 mm Hg and 1.6 ± 0.3 cm2, respectively. Paravalvular leak at 7 years was none/trace in 88.6% and mild in 11.4%. In patients undergoing isolated AVR, the cumulative probability of pacemaker implantation was 13.9% at 30 days, 15.5% at 1 year, and 21.8% at 7 years. Conclusions: AVR for aortic stenosis using an RDV is associated with low rates of late adverse events. This surgical pericardial tissue platform provides excellent and stable hemodynamic performance through 7 years.

5.
Ann Thorac Surg ; 2024 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-38286202

RESUMEN

BACKGROUND: The management of aortic stenosis has evolved to stratification by age as reflected in recent societal guidelines. We evaluated age-stratified surgical aortic valve replacement (SAVR) trends and outcomes in patients with bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) from The Society of Thoracic Surgeons Adult Cardiac Surgery Database. METHODS: This cohort included adults (≥18 years) undergoing SAVR for severe aortic stenosis between July 2011 and December 2022. Comparisons were stratified by age (<65 years, 65-79 years, ≥80 years) and BAV or TAV status. Primary end points included operative mortality, composite morbidity and mortality, and permanent stroke. Observed to expected ratios by The Society of Thoracic Surgeons predicted risk of mortality were calculated. RESULTS: In total, 200,849 SAVR patients (55,326 BAV [27.5%], 145,526 TAV [72.5%]) from 1238 participating hospitals met study criteria. Annual SAVR volumes decreased by 45% (19,560 to 10,851) during the study period. The decrease was greatest (96%) for patients ≥80 years of age (4914 to 207). The relative prevalence of BAV was greater in younger patients (<65 years, 69,068 [49.5% BAV]; 65-79 years, 104,382 [19.1% BAV]; ≥80 years, 27,399 [4.5% BAV]). The observed mortality in <80-year-old BAV patients (<65 years, 1.08; 65-79 years, 1.21; ≥80 years, 3.68) was better than the expected mortality rate (<65 years, 1.22; 65-79 years, 1.54; ≥80 years, 3.14). CONCLUSIONS: SAVR volume in the transcatheter era has decreased substantially, particularly for patients ≥80 years old and for those with TAV. Younger patients with BAV have better than expected outcomes, which should be carefully considered during shared decision-making in the treatment of aortic stenosis. SAVR should remain the preferred therapy in this population.

6.
Ann Thorac Surg ; 2024 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-38286206

RESUMEN

The Society of Thoracic Surgeons 2023 clinical practice guidelines for the surgical management of atrial fibrillation incorporate the most recent evidence for surgical ablation and left atrial appendage occlusion in different clinical scenarios. Substantial new evidence regarding the risks and benefits of surgical left atrial appendage occlusion and the long-term benefits of surgical ablation has been produced in the last five years. In comparison to the 2017 clinical practice guideline, the current update has an emphasis on surgical ablation in first-time, non-emergent cardiac surgery and its long-term benefits, an extension of the recommendation to perform surgical ablation in all patients with atrial fibrillation undergoing first-time, non-emergent cardiac surgery and a new class I recommendation for left atrial appendage occlusion in all patients with atrial fibrillation undergoing first-time, non-emergent cardiac surgery. Further guidance is provided for patients with structural heart disease and atrial fibrillation being considered for transcatheter valve repair or replacement, as well as patients in need of isolated left atrial appendage management who are not candidates for surgical ablation. The importance of a multidisciplinary team assessment, treatment planning, and long-term follow-up are reiterated in this clinical practice guideline with a class I recommendation, along with the other recommendations from the 2017 guidelines which remained unchanged in their class of recommendation and level of evidence.

7.
Ann Thorac Surg ; 117(2): 336-343, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37769702

RESUMEN

BACKGROUND: The safety and effectiveness of the RelayPro endograft (Terumo Aortic) was assessed for the treatment of acute, complicated type B aortic dissection (TBAD). METHODS: A prospective pivotal trial analyzed a primary end point of all-cause mortality at 30 days. Secondary end points included technical success, major adverse events (disabling stroke, renal failure, and paraplegia/paralysis), endoleaks, patency, rupture, device integrity, false lumen perfusion, reinterventions, aortic expansion, and migration evaluated to 5 years. RESULTS: The study involved 22 United States centers and enrolled 56 patients (mean age, 59.5 ± 11.4 years) from 2017 to 2021; of whom, 73.2% were men and 53.6% were African American. TBAD was complicated by malperfusion of the kidneys (51.8%), lower extremities (35.7%), and viscera (33.9%), and rupture (10.7%). Dissection extended proximally to zones 1/2 (14.3%) and zone 3 (78.6%) and distally to the iliac arteries (67.3%). Most procedures were percutaneous (85.5%). Technical success was 100%. Median hospitalization was 7 days (interquartile range, 5-12 days). All-cause mortality at 30 days was 1.8% (1 of 56; upper 95% CI, 8.2%; P < .0001). Seven major adverse events occurred in 6 patients (10.7%), consisting of paraplegia (n = 3), paraparesis (n = 2), disabling stroke (n = 1), and renal failure (n = 1). All paraplegia/paraparesis resolved with lumbar drainage. Kaplan-Meier analysis estimated a freedom from major adverse events of 89.1% at each interval from 30 days to 3 years. There was 1 endoleak (Type Ia), 2 retrograde dissections, and aortic diameter growth occurred in 2. There has been no rupture, fistula, component separation, patency loss, stenosis, kinking, twisting, bird beak, loss of device integrity, or fracture. CONCLUSIONS: RelayPro is safe and effective in acute, complicated TBAD. Follow-up is ongoing to evaluate longer-term outcomes and durability.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Insuficiencia Renal , Accidente Cerebrovascular , Masculino , Humanos , Estados Unidos , Persona de Mediana Edad , Anciano , Femenino , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Torácica/diagnóstico , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Estudios Prospectivos , Resultado del Tratamiento , Stents/efectos adversos , Disección Aórtica/cirugía , Endofuga/etiología , Paraplejía/etiología , Estudios Retrospectivos , Insuficiencia Renal/etiología , Accidente Cerebrovascular/etiología , Paraparesia/complicaciones , Procedimientos Endovasculares/efectos adversos
8.
Cochrane Database Syst Rev ; 12: CD011793, 2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38054555

RESUMEN

BACKGROUND: Aortic valve disease is a common condition easily treatable with cardiac surgery. This is conventionally performed by opening the sternum ('median sternotomy') and replacing the valve under cardiopulmonary bypass. Median sternotomy is well tolerated, but as less invasive options become available, the efficacy of limited incisions has been called into question. In particular, the effects of reducing the visibility and surgical access have raised safety concerns with regard to the placement of cannulae, venting of the heart, epicardial wire placement, and de-airing of the heart at the end of the procedure. These difficulties may increase operating times, affecting outcome. The benefits of smaller incisions are thought to include decreased pain; improved respiratory mechanics; reductions in wound infections, bleeding, and need for transfusion; shorter intensive care stay; better cosmesis; and a quicker return to normal activity. This is an update of a Cochrane review first published in 2017, with seven new studies. OBJECTIVES: To assess the effects of minimally invasive aortic valve replacement via a limited sternotomy versus conventional aortic valve replacement via median sternotomy in people with aortic valve disease requiring surgical replacement. SEARCH METHODS: We performed searches of CENTRAL, MEDLINE and Embase from inception to August 2021, with no language limitations. We also searched two clinical trials registries and manufacturers' websites. We reviewed references of primary studies to identify any further studies of relevance. SELECTION CRITERIA: We included randomised controlled trials comparing aortic valve replacement via a median sternotomy versus aortic valve replacement via a limited sternotomy. We excluded trials that performed other minimally invasive incisions such as mini-thoracotomies, port access, transapical, transfemoral or robotic procedures. Although some well-conducted prospective and retrospective case-control and cohort studies exist, these were not included in this review. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trial papers to extract data, assess quality, and identify risk of bias. A third review author provided arbitration where required. We determined the certainty of evidence using the GRADE methodology and summarised results of patient-relevant outcomes in a summary of findings table. MAIN RESULTS: The review included 14 trials with 1395 participants. Most studies had at least two domains at high risk of bias. We analysed 14 outcomes investigating the effects of minimally invasive limited upper hemi-sternotomy on aortic valve replacement as compared to surgery performed via full median sternotomy. Upper hemi-sternotomy may have little to no effect on mortality versus full median sternotomy (risk ratio (RR) 0.93, 95% confidence interval (CI) 0.45 to 1.94; 10 studies, 985 participants; low-certainty evidence). Upper hemi-sternotomy for aortic valve replacement may increase cardiopulmonary bypass time slightly, although the evidence is very uncertain (mean difference (MD) 10.63 minutes, 95% CI 3.39 to 17.88; 10 studies, 1043 participants; very low-certainty evidence) and may increase aortic cross-clamp time slightly (MD 6.07 minutes, 95% CI 0.79 to 11.35; 12 studies, 1235 participants; very low-certainty evidence), although the evidence is very uncertain. Most studies had at least two domains at high risk of bias. Postoperative blood loss was probably lower in the upper hemi-sternotomy group (MD -153 mL, 95% CI -246 to -60; 8 studies, 767 participants; moderate-certainty evidence). Low-certainty evidence suggested that there may be no change in pain scores by upper hemi-sternotomy (standardised mean difference (SMD) -0.19, 95% CI -0.43 to 0.04; 5 studies, 649 participants). Upper hemi-sternotomy may result in little to no difference in quality of life (MD 0.03 higher, 95% CI 0 to 0.06 higher; 4 studies, 624 participants; low-certainty evidence). Two studies reporting index admission costs concluded that limited sternotomy may be more costly at index admission in the UK National Health Service (MD 1190 GBP more, 95% CI 420 GBP to 1970 GBP, 2 studies, 492 participants; low-certainty evidence). AUTHORS' CONCLUSIONS: The evidence was of very low to moderate certainty. Sample sizes were small and underpowered to demonstrate differences in some outcomes. Clinical heterogeneity was also noted. Considering these limitations, there may be little to no effect on mortality. Differences in extracorporeal support times are uncertain, comparing upper hemi-sternotomy to full sternotomy for aortic valve replacement. Before widespread adoption of the minimally invasive approach can be recommended, there is a need for a well-designed and adequately powered prospective randomised controlled trial. Such a study would benefit from also performing a robust cost analysis. Growing patient preference for minimally invasive techniques merits thorough quality of life analyses to be included as end points, as well as quantitative measures of physiological reserve.


Asunto(s)
Enfermedad de la Válvula Aórtica , Herida Quirúrgica , Humanos , Válvula Aórtica/cirugía , Esternotomía/efectos adversos , Calidad de Vida , Estudios Prospectivos , Estudios Retrospectivos , Medicina Estatal , Dolor , Ensayos Clínicos Controlados Aleatorios como Asunto
10.
N Engl J Med ; 389(21): 1949-1960, 2023 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-37874020

RESUMEN

BACKGROUND: A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown. METHODS: We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years. RESULTS: A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group. CONCLUSIONS: Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estudios de Seguimiento , Readmisión del Paciente , Insuficiencia Cardíaca/etiología
11.
Am J Emerg Med ; 70: 113-118, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37270850

RESUMEN

INTRODUCTION: Type A Aortic Dissection (TAAD) is a surgical emergency with a time-dependent rate of mortality. We hypothesized that a direct-to-operating room (DOR) transfer program for patients with TAAD would reduce time to intervention. METHODS: A DOR program was started at an urban tertiary care hospital in February 2020. We performed a retrospective study of adult patients undergoing treatment for TAAD before (n = 42) and after (n = 84) implementation of DOR. Expected mortality was calculated using the International Registry of Acute Aortic Dissection risk prediction model. RESULTS: Median time from acceptance of transfer from emergency physician to operating room arrival was 1.37 h (82 min) faster in DOR compared to pre-DOR (1.93 h vs 3.30 h, p < 0.001). Median time from arrival to operating room was 1.14 h (72 min) faster after DOR compared to pre-DOR (0.17 h vs 1.31 h, p < 0.001). In-hospital mortality was 16.2% in pre-DOR, with an observed-to-expected (O/E) ratio of 1.03 (p = 0.24) and 12.0% in the DOR group, with an O/E ratio of 0.59 (p < 0.001). CONCLUSION: Creation of a DOR program resulted in decreased time to intervention. This was associated with a decrease in observed-to-expected operative mortality. The transfer of patients with acute type A aortic dissection to centers with direct-to-OR programs may result in decreased time from diagnosis to surgery.


Asunto(s)
Disección Aórtica , Quirófanos , Adulto , Humanos , Estudios Retrospectivos , Disección Aórtica/cirugía , Aorta/cirugía , Mortalidad Hospitalaria , Resultado del Tratamiento
12.
Front Cardiovasc Med ; 10: 1204736, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37363090

RESUMEN

We present unusual coronary-pulmonary collaterals in a 65-year-old CTEPH patient. Perfusion mapping of a dual-energy computed tomography (DECT) study revealed areas of right lung that were minimally perfused despite unilateral occlusion of the right pulmonary artery, leading to the discovery of coronary-pulmonary collaterals via invasive coronary angiography. Pulmonary thromboendarterectomy removed the clot en-bloc. Post-surgery DECT and catheterization confirmed restoration of pulmonary arterial circulation and excellent hemodynamic response. Here, suggestion of perfusion to a proximally obstructed lung with DECT helped to document the presence of rarely documented coronary-pulmonary artery collaterals.

13.
JAMA ; 330(2): 198, 2023 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-37171803

RESUMEN

This JAMA Patient Page describes aortic dissection, a tear in the aorta, and how it is diagnosed and treated.


Asunto(s)
Disección Aórtica , Humanos , Disección Aórtica/diagnóstico por imagen , Aorta
14.
Artículo en Inglés | MEDLINE | ID: mdl-36797175

RESUMEN

OBJECTIVE: In this study we aimed to conclusively determine whether altered aortic biomechanics are associated with wall shear stress (WSS) independent of region of tissue collection. Elevated WSS in the ascending aorta of patients with bicuspid aortic valve has been shown to contribute to local maladaptive aortic remodeling and might alter biomechanics. METHODS: Preoperative 4-dimensional flow magnetic resonance imaging was performed on 22 patients who underwent prophylactic aortic root and/or ascending aorta replacement. Localized elevated WSS was identified in patients using age-matched healthy atlases (n = 60 controls). Tissue samples (n = 78) were collected and categorized according to WSS (elevated vs normal) and region. Samples were subjected to planar biaxial testing. To fully quantify the nonlinear biomechanical response, the tangential modulus (local stiffness) at a low-stretch (LTM) and high-stretch (HTM) linear region and the onset (TZo) and end stress of the nonlinear transition zone were measured. A linear mixed effect models was implemented to determine statistical relationships. RESULTS: A higher LTM in the circumferential and axial direction was associated with elevated WSS (P = .007 and P = .018 respectively) independent of collection region. Circumferential TZo and HTM were higher with elevated WSS (P = .024 and P = .003); whereas the collection region was associated with variations in axial TZo (P = .013), circumferential HTM (P = .015), and axial HTM (P = .001). CONCLUSIONS: This study shows strong evidence that biomechanical changes in the aorta are strongly associated with hemodynamics, and not region of tissue collection for bicuspid valve aortopathy patients. Elevated WSS is associated with tissue behavior at low stretch ranges (ie, LTM and TZo).

16.
J Cardiovasc Magn Reson ; 25(1): 3, 2023 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-36698129

RESUMEN

BACKGROUND: Bicuspid aortic valve (BAV) disease is associated with increased risk of aortopathy. In addition to current intervention guidelines, BAV mediated changes in aortic 3D hemodynamics have been considered as risk stratification measures. We aimed to evaluate the association of 4D flow cardiovascular magnetic resonance (CMR) derived voxel-wise aortic reverse flow with aortic dilation and to investigate the role of aortic valve regurgitation (AR) and stenosis (AS) on reverse flow in systole and diastole. METHODS: 510 patients with BAV (52 ± 14 years) and 120 patients with trileaflet aortic valve (TAV) (61 ± 11 years) and mid-ascending aorta diameter (MAAD) > 35 mm who underwent CMR including 4D flow CMR were retrospectively included. An age and sex-matched healthy control cohort (n = 25, 49 ± 12 years) was selected. Voxel-wise reverse flow was calculated in the aorta and quantified by the mean reverse flow in the ascending aorta (AAo) during systole and diastole. RESULTS: BAV patients without AS and AR demonstrated significantly increased systolic and diastolic reverse flow (222% and 13% increases respectively, p < 0.01) compared to healthy controls and also had significantly increased systolic reverse flow compared to TAV patients with aortic dilation (79% increase, p < 0.01). In patients with isolated AR, systolic and diastolic AAo reverse flow increased significantly with AR severity (c = - 83.2 and c = - 205.6, p < 0.001). In patients with isolated AS, AS severity was associated with an increase in both systolic (c = - 253.1, p < 0.001) and diastolic (c = - 87.0, p = 0.02) AAo reverse flow. Right and left/right and non-coronary fusion phenotype showed elevated systolic reverse flow (> 17% increase, p < 0.01). Right and non-coronary fusion phenotype showed decreased diastolic reverse flow (> 27% decrease, p < 0.01). MAAD was an independent predictor of systolic (p < 0.001), but not diastolic, reverse flow (p > 0.1). CONCLUSION: 4D flow CMR derived reverse flow associated with BAV was successfully captured even in the absence of AR or AS and in comparison to TAV patients with aortic dilation. Diastolic AAo reverse flow increased with AR severity while AS severity strongly correlated with increased systolic reverse flow in the AAo. Additionally, increasing MAAD was independently associated with increasing systolic AAo reverse flow. Thus, systolic AAo reverse flow may be a valuable metric for evaluating disease severity in future longitudinal outcome studies.


Asunto(s)
Enfermedades de la Aorta , Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Humanos , Estudios Transversales , Estudios Retrospectivos , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Dilatación , Valor Predictivo de las Pruebas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/patología , Enfermedades de la Aorta/complicaciones , Hemodinámica , Espectroscopía de Resonancia Magnética
17.
JAMA Cardiol ; 8(3): 281-289, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36542365

RESUMEN

Importance: The management of aortic valve disease, including aortic stenosis and aortic regurgitation (AR), in younger adult patients (age <65 years) is complex, and the optimal strategy is often unclear, contingent on multiple anatomic and holistic factors. Observations: Traditional surgical approaches carry significant considerations, including compulsory lifelong anticoagulation for patients who receive a mechanical aortic valve replacement (AVR) and the risk of structural valvular deterioration and need for subsequent valve intervention in those who receive a bioprosthetic AVR. These factors are magnified in young adults who are considering pregnancy, for whom issues of anticoagulation and valve longevity are heightened. The Ross procedure has emerged as a promising alternative; however, its adoption is limited to highly specialized centers. Valve repair is an option for selected patients with AR. These treatment options offer varying degrees of durability and are associated with different risks and complications, especially for younger adult patients. Patient-centered care from a multidisciplinary valve team allows for discussion of the optimal timing of intervention and the advantages and disadvantages of the various treatment options. Conclusions and Relevance: The management of severe aortic valve disease in adults younger than 65 years is complex, and there are numerous considerations with each management decision. While mechanical AVR and bioprosthetic AVR have historically been the standards of care, other options are emerging for selected patients but are not yet generalizable beyond specialized surgical centers. A detailed discussion by members of the multidisciplinary heart team and the patient is an integral part of the shared decision-making process.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Embarazo , Femenino , Adulto Joven , Humanos , Anciano , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Anticoagulantes/uso terapéutico
18.
J Magn Reson Imaging ; 57(6): 1752-1763, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36148924

RESUMEN

BACKGROUND: 4D Flow MRI is a quantitative imaging technique to evaluate blood flow patterns; however, it is unclear how compressed sensing (CS) acceleration would impact aortic hemodynamic quantification in type B aortic dissection (TBAD). PURPOSE: To investigate CS-accelerated 4D Flow MRI performance compared to GRAPP-accelerated 4D Flow MRI (GRAPPA) to evaluate aortic hemodynamics in TBAD. STUDY TYPE: Prospective. POPULATION: Twelve TBAD patients, two volunteers. FIELD STRENGTH/SEQUENCE: 1.5T, 3D time-resolved cine phase-contrast gradient echo sequence. ASSESSMENT: GRAPPA (acceleration factor [R] = 2) and two CS-accelerated (R = 7.7 [CS7.7] and 10.2 [CS10.2]) 4D Flow MRI scans were acquired twice for interscan reproducibility assessment. Voxelwise kinetic energy (KE), peak velocity (PV), forward flow (FF), reverse flow (RF), and stasis were calculated. Plane-based mid-lumen flows were quantified. Imaging times were recorded. TESTS: Repeated measures analysis of variance, Pearson correlation coefficients (r), intraclass correlation coefficients (ICC). P < 0.05 indicated statistical significance. RESULTS: The KE and FF in true lumen (TL) and PV in false lumen (FL) did not show difference among three acquisition types (P = 0.818, 0.065, 0.284 respectively). The PV and stasis in TL were higher, KE, FF, and RF in FL were lower, and stasis was higher in GRAPPA compared to CS7.7 and CS10.2. The RF was lower in GRAPPA compared to CS10.2. The correlation coefficients were strong in TL (r = [0.781-0.986]), and low to strong in FL (r = [0.347-0.948]). The ICC levels demonstrated moderate to excellent interscan reproducibility (0.732-0.989). The FF and net flow in mid-descending aorta TL were significantly different between CS7.7 and CS10.2. CONCLUSION: CS-accelerated 4D Flow MRI has potential for clinical utilization with shorter scan times in TBAD. Our results suggest similar hemodynamic trends between acceleration types, but CS-acceleration impacts KE, FF, RF, and stasis more in FL. EVIDENCE LEVEL: 1 Technical Efficacy: Stage 2.


Asunto(s)
Disección Aórtica , Angiografía por Resonancia Magnética , Humanos , Angiografía por Resonancia Magnética/métodos , Estudios Prospectivos , Reproducibilidad de los Resultados , Velocidad del Flujo Sanguíneo/fisiología , Imagen por Resonancia Magnética/métodos , Disección Aórtica/diagnóstico por imagen , Hemodinámica , Imagenología Tridimensional/métodos
19.
J Am Coll Cardiol ; 80(22): 2119-2134, 2022 11 29.
Artículo en Inglés | MEDLINE | ID: mdl-36423996

RESUMEN

The treatment of left main (LM) coronary artery disease (CAD) requires complex decision-making. Recent clinical practice guidelines provide clinicians with guidance; however, decisions regarding treatment for individual patients can still be difficult. The American College of Cardiology's Cardiac Surgery Team and Interventional Council joined together to develop a practical approach to the treatment of LM CAD, taking into account randomized clinical trial, meta-analyses, and clinical practice guidelines. The various presentations of LM CAD based on anatomy and physiology are presented. Recognizing the complexity of LM CAD, which rarely presents isolated and is often in combination with multivessel disease, a treatment algorithm with medical therapy alone or in conjunction with percutaneous coronary intervention or coronary artery bypass grafting is proposed. A heart team approach is recommended that accounts for clinical, procedural, operator, and institutional factors, and features shared decision-making that meets the needs and preferences of each patient and their specific clinical situation.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Metaanálisis como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Guías de Práctica Clínica como Asunto
20.
Artículo en Inglés | MEDLINE | ID: mdl-36253292

RESUMEN

OBJECTIVE: In this prospective US investigational device exemption trial, we assessed the safety and 1-year clinical outcomes of the Thoraflex Hybrid device (Terumo Aortic) for the frozen elephant trunk technique to repair the ascending aorta, aortic arch, and descending thoracic aorta. METHODS: For the trial, which involved 12 US sites, 65 patients without rupture were recruited into the primary study group, and 9 patients were recruited into the rupture group. All patients underwent open surgical repair of the ascending aorta, aortic arch, and descending thoracic aorta in cases of aneurysm and/or dissection. The primary end point was freedom from major adverse events (MAE), defined as permanent stroke, permanent paraplegia/paraparesis, unanticipated aortic-related reoperation (excluding reoperation for bleeding), or all-cause mortality. RESULTS: In the primary study group, 2 patients were lost to follow-up at 1 year. Freedom from MAE at 1 year was 81% (51/63). Seven patients (11%) died (including 2 before 30 days or discharge), 3 patients (5%) suffered permanent stroke, and 3 (5%) developed permanent paraplegia/paraparesis. Twenty-six patients (41%) underwent planned extension procedures, including 22 endovascular procedures within a median of 122 (interquartile range, 64-156) days. In the aortic rupture group, 2 patients were lost to follow-up at 1 year. Freedom from MAE at 1 year was 71% (5/7). One patient (14%) died, 2 patients (29%) had permanent stroke, and none had permanent paraplegia/paraparesis. No extension procedures were performed in the rupture group. CONCLUSIONS: One-year results with the Thoraflex Hybrid device are acceptable. Long-term data are necessary to assess the durability of these repairs.

SELECCIÓN DE REFERENCIAS