Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Opt Express ; 32(10): 17479-17480, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38858930

RESUMEN

This erratum corrects errors that appear in Opt. Express31, 5042 (2023).10.1364/OE.480301.

2.
Atmos Meas Tech ; 16(17)2023.
Artículo en Inglés | MEDLINE | ID: mdl-37961051

RESUMEN

We present an open-path mid-infrared dual-comb spectroscopy (DCS) system capable of precise measurement of the stable water isotopologues H216O and HD16O. This system ran in a remote configuration at a rural test site for 3.75 months with 60% uptime and achieved a precision of < 2‰ on the normalized ratio of H216O and HD16O (δD) in 1000s. Here, we compare the δD values from the DCS system to those from the National Ecological Observatory Network (NEON) isotopologue point sensor network. Over the multi-month campaign, the mean difference between the DCS δD values and the NEON δD values from a similar ecosystem is < 2‰ with a standard deviation of 18‰, which demonstrates the inherent accuracy of DCS measurements over a variety of atmospheric conditions. We observe time-varying diurnal profiles and seasonal trends that are mostly correlated between the sites on daily timescales. This observation motivates the development of denser ecological monitoring networks aimed at understanding regional- and synoptic-scale water transport. Precise and accurate open-path measurements using DCS provide new capabilities for such networks.

3.
Opt Express ; 31(18): 29074-29084, 2023 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-37710714

RESUMEN

Operation of any dual-comb spectrometer requires digitization of the interference signal before further processing. Nonlinearities in the analog-to-digital conversion can alter the apparent gas concentration by multiple percent, limiting both precision and accuracy of this technique. This work describes both the measurement of digitizer nonlinearity and the development of a model that quantitatively describes observed concentration bias over a range of conditions. We present hardware methods to suppress digitizer-induced bias of concentration retrievals below 0.1%.

4.
Opt Express ; 31(3): 5042-5055, 2023 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-36785456

RESUMEN

Dual-comb spectroscopy measures greenhouse gas concentrations over kilometers of open air with high precision. However, the accuracy of these outdoor spectra is challenging to disentangle from the absorption model and the fluctuating, heterogenous concentrations over these paths. Relative to greenhouse gases, O2 concentrations are well-known and evenly mixed throughout the atmosphere. Assuming a constant O2 background, we can use O2 concentration measurements to evaluate the consistency of open-path dual-comb spectroscopy with laboratory-derived absorption models. To this end, we construct a dual-comb spectrometer spanning 1240 nm to 1700nm, which measures O2 absorption features in addition to CO2 and CH4. O2 concentration measurements across a 560 m round-trip outdoor path reach 0.1% precision in 10 minutes. Over seven days of shifting meteorology and spectrometer conditions, the measured O2 has -0.07% mean bias, and 90% of the measurements are within 0.4% of the expected hemisphere-average concentration. The excursions of up to 0.4% seem to track outdoor temperature and humidity, suggesting that accuracy may be limited by the O2 absorption model or by water interference. This simultaneous O2, CO2, and CH4 spectrometer will be useful for measuring accurate CO2 mole fractions over vertical or many-kilometer open-air paths, where the air density varies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...