Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Ophthalmol Ther ; 13(3): 819-830, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38273047

RESUMEN

INTRODUCTION: Characterizing lens thickness (LT) in patients with cataracts is important for better understanding the lens aging process and for designing new intraocular lens power formulas. This study aimed to analyze the influence of common senile cataract formation on the LT, anterior (ACS) and posterior (PCS) cortex space, and nuclear thickness (NT), controlling for sex, age, and axial length. METHODS: A cross-sectional study was performed. A consecutive sample of 603 volunteers (403 women, 200 men) aged 59.1 ± 18.8 years was recruited. The standardized Lens Opacification Classification System (LOCS)-III was used to classify eyes (randomly selected) into cataractous and non-cataractous groups. Also, they were classified according to the cataract location (presence or absence of cortical, nuclear, or posterior subcapsular cataract). Optical biometry was performed to measure LT, ACS, NT, and PCS. Propensity score was used to match participants one-to-one for sex, age, and axial length. Groups were compared using the Student's t test or Yuen's test. RESULTS: The four classifications divided unmatched eyes into: 361 cataractous lenses and 242 non-cataractous, 226 cortical and 377 non-cortical cataractous, 313 nuclear and 290 non-nuclear cataractous and 242 subcapsular and 361 non-subcapsular cataractous. Before matching, cataractous eyes showed significantly higher LT (4.52 ± 0.39 vs. 3.94 ± 0.46 mm, p < 0.001), ACS (0.75 ± 0.20 vs. 0.58 ± 0.23 mm, p < 0.001), NT (3.34 ± 0.23 vs. 3.18 ± 0.25 mm, p < 0.001) and PCS (0.42 ± 0.19 vs. 0.37 ± 0.19 mm, p = 0.003). Matched lens, cortical, nuclear, and subcapsular cataract samples comprised 146, 258, 182, and 226 eyes, respectively. After matching, no significant differences were observed in LT (4.34 ± 0.37 vs. 4.33 ± 0.36 mm, p = 0.94), ACS (0.72 ± 0.20 vs. 0.76 ± 0.19 mm, p = 0.08), NT (3.31 ± 0.22 vs. 3.30 ± 0.23 mm, p = 0.24) and PCS (0.42 ± 0.19 vs. 0.43 ± 0.16 mm, p = 0.79). CONCLUSIONS: The presence of senile cortical, nuclear, and posterior subcapsular cataract have no effect on LT, ACS, NT, and PCS. Confounding factors should be controlled for when measuring LT and its main components.

2.
Int Ophthalmol ; 43(12): 4711-4718, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37697080

RESUMEN

PURPOSE: To evaluate the effect of EVO+ Visian Implantable Collamer Lens (ICL) implantation on the iridocorneal angle pigmentation and structures. METHODS: Myopic refractive surgery candidates who underwent posterior chamber EVO+ ICL implantation were evaluated preoperatively and 3 and 6 months postoperatively. High-resolution images of the iridocorneal angle (nasal, superior, temporal and inferior quadrants) were acquired during gonioscopy. A masked observer, blinded to study visits and patients' information, evaluated the angle width, apparent iris root insertion, iris configuration, and trabecular meshwork pigmentation according to the Spaeth scale in two different occasions. The intra-rater reliability was estimated using the weighted Gwet's Agreement Coefficient (AC2). Differences between visits were analyzed using the Cochran Q test or the Friedman test. RESULTS: Twenty-one patients (13 females and 8 males) aging 31.3 ± 6.3 years old were recruited. The intra-rater reliability of gonioscopy assessment was excellent for every parameter assessed (AC2 ≥ 0.97). No significant differences were found among the study visits for any quadrant in the angle width (p ≥ 0.74), apparent iris root insertion (p ≥ 0.22), iris configuration (p ≥ 0.21) and trabecular meshwork pigmentation (p ≥ 0.24). Mean pigmentation of trabecular meshwork for the four quadrants did not vary either among visits (p = 0.25). CONCLUSIONS: The EVO+ ICL implantation after uneventful procedures appears not to clinically affect the iridocorneal angle pigmentation and/or structures during a short-medium follow-up using gonioscopy assessment. The intra-rater reliability of glaucoma specialists assessing iridocorneal angle structures using gonioscopy images is very high.


Asunto(s)
Implantación de Lentes Intraoculares , Trastornos de la Pigmentación , Masculino , Femenino , Humanos , Adulto , Reproducibilidad de los Resultados , Implantación de Lentes Intraoculares/métodos , Cámara Anterior , Malla Trabecular/cirugía , Iris/cirugía , Pigmentación , Gonioscopía
3.
Graefes Arch Clin Exp Ophthalmol ; 261(10): 2853-2861, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37115266

RESUMEN

PURPOSE: To assess the relationship between anterior chamber depth (ACD) and lens thickness (LT), as well as its three main components (anterior and posterior cortex and nucleus thickness), in cataractous and non-cataractous eyes, depending on the axial length (AxL). METHODS: Anterior and posterior cortex and nucleus thickness of the crystalline lens, ACD, and AxL were measured using optical low-coherence reflectometry in cataractous and non-cataractous eyes. They were also classified into hyperopia, emmetropia, myopia, and high myopia, depending on AxL; thus, eight subgroups were created. A minimum sample size of 44 eyes (of 44 patients) for each group was recruited. Linear models were fitted for the whole sample and each AxL subgroup to assess if there were differences in the relationships between the crystalline lens variables and ACD, including age as a covariate. RESULTS: Three hundred seventy cataract patients (237 females, 133 males) and 250 non-cataract controls (180 females, 70 males), aged 70.5 ± 9.4 and 41.9 ± 15.5 years, respectively, were recruited. The mean AxL, ACD, and LT for the cataractous and non-cataractous eyes were 23.90 ± 2.05, 24.11 ± 2.11, 2.64 ± 0.45, and 2.91 ± 0.49, 4.51 ± 0.38, 3.93 ± 0.44 mm, respectively. The inverse relationship of LT, anterior and posterior cortex, and nucleus thickness with ACD was not significantly (p ≥ 0.26) different between cataractous and non-cataractous eyes. Further subclassification of the sample depending on AxL showed that the inverse relationship between the posterior cortex and ACD was no longer significant (p > 0.05) for any non-cataractous AxL group. LT, anterior and posterior cortex, and nucleus thickness was not significantly (p ≥ 0.43) different between cataractous and non-cataractous eyes for the whole sample, and all AxL groups after adjusting for age. CONCLUSIONS: The presence of cataracts does not modify the inverse relationship of the LT, anterior and posterior cortex, and nucleus with ACD. And this relationship does not seem to depend importantly on AxL. Besides, the possible differences in LT, anterior and posterior cortex, and nucleus between cataractous and non-cataractous eyes may not be caused by lens opacification, but possibly by the progressive lens growth due to aging.


Asunto(s)
Catarata , Cristalino , Miopía , Masculino , Femenino , Humanos , Catarata/diagnóstico , Envejecimiento , Cámara Anterior , Biometría
4.
Expert Rev Med Devices ; 20(2): 75-83, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36708714

RESUMEN

INTRODUCTION: Intraocular lens implantation in phakic eyes for the correction of refractive error is currently a widespread procedure. The EVO and EVO+ Visian Implantable Collamer Lenses (ICL) are two of the most prevalent lenses implanted. They incorporate a central orifice to avoid the need for iridotomy. The main difference between both ICL is the higher optical diameter zone provided by the EVO+, allowing a better quality of vision at night. This review aims to provide an overview of the current ICL models available for correcting myopia and myopic astigmatism. AREAS COVERED: During the last decade, more than 100 scientific papers analyzing the performance of EVO and EVO+ lenses have been published. This review describes the objective visual performance achieved with the implantation of central hole ICL lenses and the subjective perception of the patients implanted with these lenses. In addition, the safety and the potential complications associated with undergoing an EVO and EVO+ ICL implantation have been addressed. EXPERT OPINION: Refractive surgeons and candidates to undergo ICL implantation should be aware of the excellent safety and visual outcomes provided by the implantation of central hole ICL lenses. However, future research could address minor issues currently not resolved.


Asunto(s)
Astigmatismo , Miopía , Lentes Intraoculares Fáquicas , Humanos , Astigmatismo/complicaciones , Astigmatismo/cirugía , Implantación de Lentes Intraoculares/métodos , Refracción Ocular , Miopía/complicaciones , Miopía/cirugía
5.
J Cataract Refract Surg ; 49(1): 21-28, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36573762

RESUMEN

PURPOSE: To assess the repeatability and agreement of Cartesian coordinates and the length of apparent chord mu and pupil diameter measurements during static (Galilei G4) and dynamic (Topolyzer Vario) evaluations. SETTING: IOBA-Eye Institute, Valladolid, Spain. DESIGN: Case series. METHODS: 3 consecutive measurements per scenario (Galilei G4 and Topolyzer Vario under low mesopic and photopic conditions) were performed by the same clinician. The intrasession repeatability was assessed using the within-subject SD (Sw), the precision, the coefficient of variation, and the intraclass correlation coefficient (ICC). The agreement was analyzed using repeated-measures analysis of variance and the Bland-Altman method. RESULTS: Thirty-seven healthy participants were recruited. The Sw values for chord mu parameters and pupil diameter ranged from 0.01 to 0.03 and 0.08 to 0.21, respectively. The ICC was ≥0.89 for all parameters. Galilei G4 and Topolyzer Vario under low mesopic and photopic conditions provided significantly different measures of apparent chord mu length (0.23 ± 0.11 mm, 0.30 ± 0.10 mm, and 0.25 ± 0.11 mm, respectively, P ≤ .02), X-coordinate (-0.18 ± 0.12 mm, -0.27 ± 0.11 mm, and -0.21 ± 0.12 mm, respectively, P < .001), and pupil diameter (3.38 ± 0.50 mm, 6.29 ± 0.60 mm, and 3.04 ± 0.41 mm, respectively, P < .001). Y-coordinate values obtained by Galilei G4 and Topolyzer Vario under low mesopic conditions were significantly different (0.06 ± 0.13 mm vs 0.03 ± 0.11 mm, respectively, P = .02), in contrast to Galilei G4 and Topolyzer Vario under photopic conditions (0.05 ± 0.13 mm, P = .82) and both illumination conditions of Topolyzer Vario (P ≥ .23). CONCLUSIONS: Galilei G4 and Topolyzer Vario provide consistent measurements of apparent chord mu Cartesian coordinates and length, as well as pupil diameter; however, the measurements are not interchangeable. Ophthalmic surgeons should consider these findings when planning customized intraocular lens implantation and refractive surgery procedures.


Asunto(s)
Visión de Colores , Procedimientos Quirúrgicos Refractivos , Humanos , Reproducibilidad de los Resultados , Voluntarios Sanos , Iluminación , Pupila
6.
Int Ophthalmol ; 43(5): 1501-1510, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36260197

RESUMEN

PURPOSE: To assess whether the postoperative outcomes of the implantation of an EVO + implantable collamer lens (ICL) in one eye can be used as a predictor of the vault of the fellow eye, and to evaluate the vault changes of the implantation in both eyes during the postoperative period. METHODS: A prospective study including 40 eyes of 20 patients with a bilateral EVO + ICL implantation was performed. Subjects were evaluated before the surgery and 1 day, 1 week and 1, 3 and 6 months postoperatively. Central vault was assessed using spectral-domain optical coherence tomography. The inter-eye and follow-up analyses were performed using lineal models and the Bland-Altman method. RESULTS: The vault of the first implanted eye at the 1-day visit highly predicts the vault of the second eye (R2 = .87; P < .001); the mean inter-eye difference was - 0.95 µm, and the superior and inferior limits of agreement were -50.27 µm and 148.37 µm, respectively. This relationship was maintained during the medium-term follow-up, not finding differences in the slopes among visits (P ≥ .09). A progressive decrease of vault was found during the follow-up (P < .001). Larger vault change 6 months after the surgery was associated with higher vault 1 day after the ICL implantation (R2 = .19;P = .005). CONCLUSION: One-day postoperative vault in the first eye can help to predict the optimal ICL sizing in the second eye. Vault tends to decrease during the first 6 months after EVO + ICL implantation. Eyes with higher initial vaults will also show larger reductions during the medium-term follow-up.


Asunto(s)
Miopía , Lentes Intraoculares Fáquicas , Humanos , Implantación de Lentes Intraoculares/métodos , Estudios Prospectivos , Miopía/diagnóstico , Miopía/cirugía , Periodo Posoperatorio , Estudios Retrospectivos
7.
Eye (Lond) ; 37(8): 1640-1645, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36002509

RESUMEN

BACKGROUND/OBJECTIVES: To determine the influence of decentration and tilt of a pseudophakic aspheric intraocular lens (IOL) on visual acuity (VA) and higher-order aberrations (HOAs), and to analyze the agreement between pupil center/axis and iridocorneal angles center/axis when assessing IOL decentration and tilt. SUBJECTS/METHODS: A prospective interventional case series study including thirty-three patients undergoing Tecnis ZCB00 (Abbott Medical Optics) implantation. IOL decentration and tilt with respect to two reference systems (pupil and iridocorneal angles centers/axes), in cartesian (X,Y) and polar (radius/tilt, polar angle/azimuth) coordinates, were assessed with optical coherence tomography. VA and internal and ocular HOAs were evaluated. Multiple linear regression models and intraclass correlation coefficient (ICC) were computed. RESULTS: IOL decentration only showed a significant effect on internal HOAs for [Formula: see text] (R2 = 0.20, P = 0.04). IOL decentration with respect to the pupil center showed a significant effect on ocular [Formula: see text] (R2 = 0.18, P = 0.05), [Formula: see text] (R2 = 0.36, P = 0.001) and [Formula: see text] (R2 = 0.24, P = 0.02); and with respect to the center of iridocorneal angles, on ocular [Formula: see text] (R2 = 0.21, P = 0.03), [Formula: see text] (R2 = 0.32, P = 0.003), primary coma (R2 = 0.41, P < 0.001), and coma-like (R2 = 0.40, P = 0.001). Poor agreement between both reference systems was found for IOL decentration measurements (ICC ≤ 0.41), except for the polar angle coordinate (ICC = 0.83). Tilt measurements showed good agreement (ICC ≥ 0.75). CONCLUSIONS: Tecnis ZCB00 decentration and tilt values after uneventful implantation appear not to have influence on VA, and their effect on HOAs are not high enough to clinically affect quality of vision. Pupil and iridocorneal angles used as reference systems may be interchangeable for IOL tilt measurements, but not for decentration.


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares , Estudios Prospectivos , Coma , Agudeza Visual
8.
J Refract Surg ; 38(3): 177-183, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35275006

RESUMEN

PURPOSE: To determine the longitudinal variation in the KS-aquaPORT central hole location of the phakic EVO+I Implantable Collamer Lens (ICL) (STAAR Surgical) and analyze its influence on visual performance, quality of vision (QoV), and quality of life (QoL). METHODS: A prospective study was performed including 36 patients who had EVO+ ICL implantation. The KS-aquaPORT central hole location (Cartesian and polar coordinates) was determined with respect to the pupil center and visual axis. The effect of time (6-month follow-up) on central hole location was analyzed using linear mixed models. The effect of the KS-aquaPORT location on visual performance, QoV, and QoL parameters was assessed with multivariate regression models. RESULTS: With respect to the visual axis, no significant changes in KS-aquaPORT location were found during follow-up. With respect to the pupil center, the X-coordinate and radius of KS-aquaPORT location showed modest, but significant (P ≤ .05) differences between 1-week and 3-month postoperative visits, and between 1-week and 6-month visits. X-coordinate variation was significant (P = .022) between 1-and 6-month visits. With respect to the visual axis, greater KS-aquaPORT decentration was associated with worse visual acuity (X-coordinate: P = .004; radius: P = .006), and inferior decentration with longer xenon-type glare photostress recovery time (P = .021). With respect to the pupil center, a lower radius was associated with better QoV scores (P ≤ .01) and temporal decentration produced higher ring-shaped dysphotopsia (P = .007). CONCLUSIONS: EVO+ ICL KS-aquaPORT location appears to be clinically stable up to 6 months postoperatively. A central location of the EVO+ ICL KS-aquaPORT hole is preferred because it allows reduced perception of dysphotopic phenomena that can result in better QoV. [J Refract Surg. 2022;38(3):177-183.].


Asunto(s)
Miopía , Lentes Intraoculares Fáquicas , Humanos , Implantación de Lentes Intraoculares/métodos , Miopía/cirugía , Estudios Prospectivos , Calidad de Vida
9.
Ophthalmol Ther ; 11(2): 677-687, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35107813

RESUMEN

INTRODUCTION: There is a lack of evidence about the exact deterioration of visual function associated with the age-related natural changes in the lens, particularly in intermediate (stage-2) dysfunctional lens syndrome (DLS). Standard photopic visual acuity and contrast sensitivity tests may not show the visual worsening in daily life activities, such as oncoming vehicle headlights at night. The purpose of this study was to analyze visual function under different conditions and glare sources in stage-2 DLS. METHODS: Forty patients over 49 years of age with initial bilateral lens opacification (Lens Opacities Classification System III [LOCS-III] scores up to 3), best-corrected visual acuity of 20/25 or better, and no ocular disease were evaluated. Binocular photopic and mesopic contrast sensitivity (CS) with/without halogen and xenon increasing glare sources were analyzed. Mesopic disability glare (MDG) was calculated as the difference between mesopic CS with/without the glare source. RESULTS: The median logarithmic CS (logCS) values were lower under mesopic conditions (1.05) than under photopic illumination (1.65; P < 0.001). Halogen and xenon glare further decreased mesopic CS (both, median logCS 0.75, P < 0.001). The mean MDG was 0.31 ± 0.10 log units for halogen glare and 0.33 ± 0.09 log units for xenon glare. The mesopic CS and MDG were not associated with any photopic test. The mesopic CS with glare but not photopic CS or mesopic CS was correlated with the LOCS-III scores. The best association was provided by MDG, which showed a pooled correlation with LOCS-III nuclear opalescence (r = 0.411, P < 0.001) and cortical scores (r = 0.226, P = 0.04). CONCLUSION: The mesopic CS under a glare source is an independent early indicator of visual impairment in stage-2 DLS patients, and appears to be substantial. Furthermore, the MDG is more sensitive than photopic and mesopic CS for evaluating patients with initial phacosclerosis. Surgeons should consider this in the decision-making process of the correct timing for lens surgery.

10.
Exp Eye Res ; 214: 108878, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34871567

RESUMEN

Human corneal epithelial cells are needed to study corneal pathophysiology in vitro. Due to the limitations of cell lines, the use of primary cells is highly desirable, but the scarcity of human tissues, along with ethical issues, make it difficult to accomplish all required experiments. In advanced surface ablation (ASA), the central corneal epithelium is removed and discarded. We hypothesized that ASA samples could be used to perform in vitro assays. In this study, 29 samples from patients undergoing ASA were recovered in supplemented DMEM/F12 culture medium, RIPA buffer, or RLT lysis buffer. The first aim was to determine whether cells could be maintained in culture. Although with the explant technique, tissue pieces did not attach to the culture surface, after disaggregation, cells showed high viability (90.0 ± 6.0%), attached to plates, and remained viable for up to 14 days. The second aim was to elucidate if ASA samples could be used to study protein or gene expression. Cytokeratin-3, ZO-1, Ki67, and E-cadherin protein expression were confirmed by immunofluorescence. Total protein (485.8 ± 115.8 µg) was isolated from cells in RIPA buffer, and GAPDH was detected by Western blotting, indicating that samples are adequate for protein studies. RNA (9.0 ± 3.6 µg) was isolated from samples in RLT lysis buffer, and GAPDH gene expression was studied by PCR, confirming that samples were also suitable for gene expression studies. These results suggest that samples obtained from corneal surface ablation procedures may constitute a valuable source of human cells to accomplish in vitro studies.


Asunto(s)
Cirugía Laser de Córnea , Epitelio Corneal/citología , Adulto , Antígenos CD/metabolismo , Biomarcadores/metabolismo , Western Blotting , Cadherinas/metabolismo , Recuento de Células , Técnicas de Cultivo de Célula , Supervivencia Celular , Electroforesis en Gel de Poliacrilamida , Epitelio Corneal/metabolismo , Proteínas del Ojo/metabolismo , Femenino , Humanos , Queratina-3/metabolismo , Antígeno Ki-67/metabolismo , Masculino , Microscopía Fluorescente , Colgajos Quirúrgicos , Proteína de la Zonula Occludens-1/metabolismo
11.
Brain Sci ; 11(9)2021 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-34573202

RESUMEN

The authors of this study evaluated the potential benefit on visual performance of a novel 3 week visual rehabilitation program based on the use of Gabor patches in patients undergoing bilateral cataract surgery with the implantation of two models of trifocal diffractive intraocular lens (IOL). A total of 30 patients were randomly assigned to two groups: a study group (15 patients) that used a videogame based on Gabor patches and a placebo group (15 patients) that used a videogame without specific stimuli for improving visual performance. No statistically significant differences between groups were found in distance, intermediate, and near post-training visual acuity (p ≥ 0.15). Significantly better distance contrast sensitivity (CS) was found for the spatial frequencies of 6 (p = 0.02) and 12 cpd (p = 0.01) in the study group. Likewise, significantly better values of near CS were found in the study group compared to the placebo group for the spatial frequency of 1.5 cpd (p = 0.02). In conclusion, a 3 week visual rehabilitation program based on the use of Gabor patches in the immediate postoperative period after the bilateral implantation of trifocal diffractive IOLs seems to be beneficial for improving both distance and near visual performance achieved with the implant.

12.
BMC Ophthalmol ; 21(1): 223, 2021 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-34006229

RESUMEN

BACKGROUND: Prevalence of high myopia is continuously increasing, thus, patients affected with staphyloma are abundant worldwide. Assessment of the quality of vision in these patients is mandatory for a proper clinical counselling, specially when undergoing surgical procedures that require intraocular lenses implantation. Thus, the purpose of the study was to assess monochromatic higher order aberrations (HOAs) in highly myopic eyes with staphyloma with or without a dome-shaped macula. METHODS: Participants underwent spectral-domain optical coherence tomography, ocular axial biometry, dual Scheimpflug photography and integrated Placido disk topography, and Hartmann-Shack wavefront analysis. Five groups were evaluated: a low-moderate myopia control group (< 6.00 diopters, n = 31) and four high myopia (≥6.00 diopters) groups: eyes without staphyloma (n = 18), eyes with inferior staphyloma (n = 14), eyes with posterior staphyloma without dome-shaped macula (n = 15) and eyes with posterior staphyloma with dome-shaped macula (n = 17). Subsequently, two new groups (including all participants) were created to assess differences between myopia with and without staphyloma. One-way analysis of covariance was performed using age and lens densitometry as covariates. RESULTS: Statistically significant (p ≤ 0.05) differences in anterior corneal fourth-order HOAs were observed between the low-moderate myopia and no-dome-shaped macula (Mean: 0.16 µm) and dome-shaped macula posterior staphyloma groups (Mean: 0.12 µm) in younger patients (≤45 years old). The same groups also showed (p ≤ 0.05) significant differences for anterior corneal primary spherical aberration (Mean: 0.19 and 0.13 µm, respectively). In addition, anterior corneal tetrafoil was significantly higher (p = 0.04) in dome-shaped macula compared to no-dome-shaped macula (Mean: 0.18 vs 0.06 µm, respectively). When all participants were grouped together, significantly lower mean anterior corneal primary spherical aberration (0.15 µm vs. 0.27 µm, p = 0.004) and higher internal primary spherical aberration (0.04 µm vs. -0.06 µm, p = 0.04) was observed in staphyloma compared to no-staphyloma myopic patients. CONCLUSIONS: Eyes with high myopia and staphyloma have less positive anterior corneal primary spherical aberration and less negative internal primary spherical aberration, suggesting that the anterior corneal surface tends to mimic in a specular fashion the posterior pole profile. This corneal behaviour appears to change in patients older than 45 years.


Asunto(s)
Mácula Lútea , Miopía , Biometría , Humanos , Persona de Mediana Edad , Tomografía de Coherencia Óptica , Agudeza Visual
13.
Transl Vis Sci Technol ; 10(2): 3, 2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-34003888

RESUMEN

Purpose: To examine whether a noncomputerized multitasking compensatory saccadic training program (MCSTP) for patients with hemianopia, based on a reading regimen and eight exercises that recreate everyday visuomotor activities using three-dimensional (3D) real-world objects, improves the visual ability/function, quality of life (QL), and functional independence (FI). Methods: The 3D-MCSTP included four in-office visits and two customized home-based daily training sessions over 12 weeks. A quasiexperimental, pretest/posttest study design was carried out with an intervention group (IG) (n = 20) and a no-training group (NTG) (n = 20) matched for age, hemianopia type, and brain injury duration. Results: The groups were comparable for the main baseline variables and all participants (n = 40) completed the study. The IG mainly showed significant improvements in visual-processing speed (57.34% ± 19.28%; P < 0.0001) and visual attention/retention ability (26.67% ± 19.21%; P < 0.0001), which also were significantly greater (P < 0.05) than in the NTG. Moreover, the IG showed large effect sizes (Cohen's d) in 75% of the total QL and FI dimensions analyzed; in contrast to the NTG that showed negligible mean effect sizes in 96% of these dimensions. Conclusions: The customized 3D-MCSTP was associated with a satisfactory response in the IG for improving complex visual processing, QL, and FI. Translational Relevance: Neurovisual rehabilitation of patients with hemianopia seems more efficient when programs combine in-office visits and customized home-based training sessions based on real objects and simulating real-life conditions, than no treatment or previously reported computer-screen approaches, probably because of better stimulation of patients´ motivation and visual-processing speed brain mechanisms.


Asunto(s)
Hemianopsia , Calidad de Vida , Humanos , Lectura , Movimientos Sacádicos , Percepción Visual
14.
Am J Ophthalmol ; 226: 117-125, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33577790

RESUMEN

PURPOSE: To assess the effect of EVO+ (V5) Visian implantable collamer lens implantation on mesopic visual performance, quality of vision (QoV), and quality of life (QoL). DESIGN: Prospective interventional case series. METHODS: Thirty-six eyes of 36 participants who underwent EVO+ implantation for myopia were evaluated preoperatively and at postoperative visits at 1 week and 1, 3, and 6 months. Visual acuity (VA) and mesopic contrast sensitivity (CS) with and without halogen- and xenon-type glare sources were evaluated at each visit. Subjective QoV was assessed with the QoV questionnaire and QoL assessed with the Quality of Life Impact of Refractive Correction (QIRC) questionnaire at each visit. Ring-shaped dysphotopsia was also assessed at each postoperative visit. Linear, cumulative link and logit mixed models were fitted to analyze the effect of the EVO+. RESULTS: Following EVO+ implantation, VA significantly (P ≤ .012) improved at the 4 postoperative visits. Mesopic CS progressively improved at 1, 3, and 6 months postoperatively (P ≤ .012). Halogen glare CS decreased at 1 week and halogen and xenon glare CS improved at 6 months (P ≤ .016). Photostress recovery time after halogen glare improved at 3 and 6 months (P ≤ .004). QoV scores improved at 1 week and 3 and 6 months (P ≤ .001). QIRC scores improved postoperatively (P < .001). Ring-shaped dysphotopsia decreased at 3 and 6 months (P ≤ .007). CONCLUSIONS: EVO+ implantation provides good mesopic visual performance, QoV, and QoL during up to 6 months follow-up. Some activities performed under mesopic conditions with glare sources may be affected during the first postoperative week. Ring-shaped dysphotopsia is negligibly bothersome 6 months after surgery.


Asunto(s)
Implantación de Lentes Intraoculares , Miopía/cirugía , Lentes Intraoculares Fáquicas , Calidad de Vida/psicología , Agudeza Visual/fisiología , Adulto , Sensibilidad de Contraste/fisiología , Femenino , Deslumbramiento , Humanos , Masculino , Visión Mesópica/fisiología , Miopía/fisiopatología , Miopía/psicología , Estudios Prospectivos , Encuestas y Cuestionarios , Trastornos de la Visión/fisiopatología
15.
J Ophthalmol ; 2020: 1468258, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32802486

RESUMEN

PURPOSE: The purpose of this study was to confirm the presence of specific patterns of epithelial response in corneal buttons from keratoconus patients. METHODS: This was a retrospective and descriptive study. 90 penetrating keratoplasty specimens obtained from patients diagnosed with keratoconus were evaluated using bright-field microscopy. Morphologically identifiable characteristics including epithelial cell density and epithelial thickness were analyzed on hematoxylin and eosin- (H&E-) and periodic acid of Schiff- (PAS-) stained slides. RESULTS: Three distinctive patterns of epithelial alteration of the central cornea were established. Pattern 3, in which the central epithelium was as thick as peripheral epithelium, was the commonest (44.4%), followed by the pattern 2, defined as central epithelium thinner than periphery epithelium (38.9%), and the uncommonest pattern was number 1, with central epithelium thicker than the periphery (16.7%). CONCLUSIONS: Three distinctive histologic patterns that could potentially have a diagnostic and prognostic value in keratoconus patients were found.

16.
Clin Ophthalmol ; 14: 613-623, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32184550

RESUMEN

PURPOSE: To evaluate the evolution of a set of proposed pain biomarkers in the saliva of subjects following Advanced Surface Ablation (ASA), in order to determine their validity as objective pain measures. METHODS: A multicenter, prospective, and descriptive study was carried out to assess the variations between biomarkers and perceived pain. The Inclusion criteria were healthy subjects who underwent a bilateral, alcohol-assisted surface ablation with epithelial removal (ASA). Pain intensity before and after surgery was assessed by Visual Analog Scale (VAS) and the Numeric Pain Rating Scale (NPRS). Cortisol, sAA, sIgA, testosterone, and sTNFαRII were assayed at four-time points (V0, baseline; V1, pre-surgery; V2, 1 hr post-surgery, and V3, 72 hrs post-surgery). Comorbidities and Hospital Anxiety and Depression (HADS) questionnaires were administrated before and at 6 hrs after the surgery. All patients were treated with cold patches, topical steroids, topical cold antibiotics, and benzodiazepines after ASA surgery. A descriptive analysis of biomarkers and pain intensity evolution and the agreement between biomarkers and pain was performed. RESULTS: Concentration of sIgA and sTNFαRII post-surgery was significantly higher at each visit compared to baseline (p-value: 0.053, p-value: <0.001, respectively). Relations between VAS scale score and putative biomarker variations were not statistically significant except for the sIgA but only at visit 0 (p-value: 0.024). The HADS questionnaire showed anxiety scores between 0 and 7 in all patients before and at 6 hrs after surgery. CONCLUSION: In this study, sIgA and sTNFαRII are the two potential biomarkers that present correlation with the VAS and these salivary substances showed acceptable levels of reproducibility in healthy subjects.

17.
Exp Eye Res ; 193: 107976, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32081669

RESUMEN

Neuropathic dry eye is one of the most frequently seen complications after corneal refractive surgery, however, its incidence decreases in a significant manner along the first six months postoperative, reaching between 10 and 45% incidence. However, little is known on the inflammatory status of the ocular surface during this recovery process. We aim to analyze the clinical and tear molecule concentration changes along six months after advanced surface ablation for myopia correction, in a prospective study including 18 eyes of 18 subjects who bilaterally underwent advanced surface ablation corneal refractive surgery. Clinical variables (uncorrected distance visual acuity, symptoms, conjunctival hyperemia, tear osmolarity, tear stability, corneal fluorescein staining, conjunctival lissamine staining, Schirmer test, and corneal esthesiometry) and a panel of 23 pro and anti-inflammatory cytokines/chemokines concentration in tears preoperatively and at 1, 3 and 6 months postoperatively were evaluated. We found that uncorrected distance visual acuity improved significantly from baseline at 1-month visit, symptoms improved and tear osmolarity decreased significantly from baseline at 3-month visit and there was a decrease in mechanical corneal threshold between 1-month and 3- and 6-month visits. Regarding tear molecules, IL-4, IL-5, IL-6, IL-13, IL-17A, and IFN-γ tear levels were significantly increased at all the three visits, compared to preoperative levels at V0; IL-2 and VEGF were also significantly increased at 1-month and 6-month visits, but not at 3-month visit, whereas IL-9 IL-10 and IL-12 were only significantly increased at 6-month visit. Although we found that there is a recovery in clinical variables at 6 months postoperatively (i.e. neuropathic dry eye was not developed in the sample), ocular surface homeostasis is not completely restored, as it can be seen by the changes in concentration of some pro and anti-inflammatory molecules measured in tears.


Asunto(s)
Citocinas/metabolismo , Síndromes de Ojo Seco/metabolismo , Terapia por Láser/efectos adversos , Procedimientos Quirúrgicos Refractivos/efectos adversos , Lágrimas/metabolismo , Adulto , Biomarcadores/metabolismo , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/etiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Concentración Osmolar , Estudios Prospectivos , Factores de Tiempo , Agudeza Visual
18.
Eur J Ophthalmol ; 30(6): 1301-1307, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31902240

RESUMEN

PURPOSE: The aim of this study is to evaluate the incidence, natural course, and distribution pattern of superficial punctate keratopathy and describe the changes in signs and symptoms of dry eye after cataract surgery. SETTING: The setting of this study is University Hospital Rio Hortega and Instituto Universitario de Oftalmobiología Aplicada, Valladolid, Spain. DESIGN: This is a prospective interventional study. MATERIALS AND METHODS: In total, 55 eyes of 55 different patients with no history of dry eye underwent standard phacoemulsification through a 2.75-mm-wide corneal incision. We measured tear break-up time, Schirmer test I, and tear meniscus height, and recorded the Ocular Surface Disease Index score, fluorescein staining patterns, and photo documentation of the ocular surface before and 1 day, 1 week, and 1 month postoperatively. Patients were divided into two groups (with and without superficial punctate keratopathy development, 1 day postoperatively). RESULTS: Patients (mean age: 75.75 ± 7.27 years) showed an incidence of 76.3% of superficial punctate keratopathy at 24 h. Location predominated in the center of the cornea until a week (32.7%) and then began to prevail in the inferior quadrant (21.8%) at 1 month. All dry eye tests were significantly worse after surgery. Ocular Surface Disease Index increased from 10.98 ± 5.05 to 15.87 ± 6.57 at 24 h (p < .001), to 12.80 ± 5.77 at 7 days (p < .001), and to 11.09 ± 4.63 at 1 month (p = .90). Fluorescein staining patterns got worse 24 h postoperatively with a score of 2.12 using the National Eye Institute/Industry-recommended guidelines staining grid. Average break-up time values were significantly lower at 1 day (6.61 ± 2.68),1 week (6.98 ± 2.79), and 1 month (7.05 ± 2.86) postoperatively than preoperatively (8.78 ± 2.97) (p < .001). The mean postoperative first month Schirmer test I value (8.32 ± 3.58) was significantly lower than preoperative value (9.05 ± 3.63) (p < .001). CONCLUSION: Phacoemulsification tends to induce short-term transitory ocular surface impairment manifesting as both signs and symptoms. Superficial punctate keratopathy distribution has a characteristic pattern evolution according to the postoperative time. Those patients with altered preoperative values are more likely to develop ocular surface disease and for longer time.


Asunto(s)
Córnea/patología , Síndromes de Ojo Seco/diagnóstico , Facoemulsificación/efectos adversos , Complicaciones Posoperatorias , Lágrimas/metabolismo , Anciano , Anciano de 80 o más Años , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/metabolismo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
19.
J Cataract Refract Surg ; 45(11): 1591-1596, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31706513

RESUMEN

PURPOSE: To analyze the effect of the central hole location in the V4c implantable collamer lens (ICL) on the quality of vision, including progressive headlight glare simulation and quality of life. SETTING: IOBA-Eye Institute, Valladolid, Spain. DESIGN: Case series. METHODS: The central hole location was determined by slitlamp and dual Scheimpflug imaging for 6 months or more postoperatively. The visual acuity, mesopic contrast sensitivity, halogen glare contrast sensitivity, xenon glare contrast sensitivity, photostress recovery time after glare, de Boer scale, and Quality of Life Impact of Refractive Correction (QIRC) questionnaire results were evaluated. Multiple regression models were used to analyze the effect of the central hole location on parameters using the pupil center and visual axis as references based on Cartesian and polar coordinates. RESULTS: The safety index was 1.13 and the efficacy index, 1.12. Under all testing circumstances, central hole decentration did not affect the visual acuity or contrast sensitivity. With the visual axis as a reference, worse QIRC values were associated with greater upward central hole displacement (P = .03) and a lower polar angle value (P = .008); also, halogen glare discomfort was greater with a higher radius (P = .04). Using the pupil center as a reference, greater nasal central hole decentration was associated with longer xenon glare photostress recovery time (P = .002). CONCLUSIONS: Implantation of the ICL with a central hole yielded excellent visual outcomes, even under increasing glare sources, regardless of the hole's location. However, hole decentration might affect patient-perceived quality of life, bothersome halogen glare, and longer xenon glare photostress recovery time. Such complaints after the early postoperative period might be managed with discrete ICL centration if the central hole is decentered upward or nasally.


Asunto(s)
Deslumbramiento/efectos adversos , Implantación de Lentes Intraoculares , Lentes Intraoculares Fáquicas , Trastornos de la Visión/fisiopatología , Agudeza Visual/fisiología , Adulto , Sensibilidad de Contraste/fisiología , Femenino , Estudios de Seguimiento , Humanos , Luz , Masculino , Visión Mesópica/fisiología , Miopía/fisiopatología , Miopía/psicología , Miopía/cirugía , Proyectos Piloto , Diseño de Prótesis , Pupila/fisiología , Calidad de Vida/psicología , Encuestas y Cuestionarios , Trastornos de la Visión/etiología , Trastornos de la Visión/psicología
20.
Clin Exp Ophthalmol ; 47(7): 871-880, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31056827

RESUMEN

IMPORTANCE: Rare transforming growth factor beta-induced (TGFBI) gene variants are involved in autosomal dominant corneal dystrophies (CDs) with heterogeneous clinical features. BACKGROUND: The purpose of this study was to analyse TGFBI gene variants and genotype-phenotype correlations in a cohort affected by atypical stromal CD. DESIGN: Retrospective cohort study (from May 2014 to September 2017). PARTICIPANTS: Thirty-five individuals from 10 unrelated South European families presenting atypical lattice CD (LCD) were included. METHODS: Corneal phenotypes were assessed by slit-lamp examination and optical coherence tomography (OCT). Contrast sensitivity was measured under mesopic conditions. Genomic DNA was obtained from blood samples, and all 17 TGFBI exons were screened for variants by Sanger sequencing. MAIN OUTCOME MEASURES: p.(L558P) variant of TGFBI gene. RESULTS: The p.(L558P) variant was identified in 22 members of the 10 families diagnosed with atypical LCD, characterized by late-onset and absence of recurrent erosion syndrome. OCT revealed punctiform deposits in the deep-mid stroma and normal anterior stroma. This variant was demonstrated to be transmitted with the disease according to autosomal dominant inheritance in most families. CONCLUSIONS AND RELEVANCE: To the best of our knowledge, we describe a detailed clinical characterization of the largest CD cohort carrying the TGFBI p.(L558P) variant. We propose that the atypical phenotype of this recently reported alteration can be classified as a form of LCD type IV. The results show that OCT and anterior-posterior analysis of the stromal location of the opacities, along with a genetic analysis of TGFBI, are required to ensure accurate diagnosis and management of CDs.


Asunto(s)
Distrofias Hereditarias de la Córnea/genética , Proteínas de la Matriz Extracelular/genética , Variación Genética , Factor de Crecimiento Transformador beta/genética , Adulto , Anciano , Anciano de 80 o más Años , Sensibilidad de Contraste/fisiología , Distrofias Hereditarias de la Córnea/diagnóstico , Distrofias Hereditarias de la Córnea/fisiopatología , Análisis Mutacional de ADN , Exones/genética , Femenino , Estudios de Asociación Genética , Humanos , Masculino , Visión Mesópica/fisiología , Persona de Mediana Edad , Linaje , Estudios Retrospectivos , Microscopía con Lámpara de Hendidura , Tomografía de Coherencia Óptica , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...