Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
1.
J Arthroplasty ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38754708

RESUMEN

INTRODUCTION: Highly cross-linked and thermally stabilized polyethylene (HXLPE) was introduced to improve wear in total hip arthroplasty (THA), with manufacturers implementing different thermal treatments to reduce oxidation. It is important to understand how long-term time in vivo affects the wear of these materials. The purpose of this study was to investigate the wear and oxidative performance of first-generation HXLPE hip inserts implanted for greater than 10 years and compare annealed and remelted HXLPE formulations. METHODS: There were 49 THA liners retrieved during routine revision surgery as part of an IRB approved implant retrieval program. Penetration rates for the liners were calculated as the difference between the thickness of the unloaded and loaded regions divided by implantation time. Oxidation indices for the rim, locking mechanism, articulating surface, and backside regions were measured using Fourier-transform infrared spectroscopy according to ASTM 2102. Mann-Whitney U Tests were used to determine the statistical difference between annealed and remelted components. RESULTS: The cohort had an average implantation time of 13.1 ± 2.6 years for annealed and 12.1 ± 1.7 years for remelted components. The components were revised most often for polyethylene wear, instability, and loosening. The penetration rate averaged 0.0177 ± 0.014 mm/year for annealed components and 0.015 ± 0.022 mm/year for remelted components. Penetration rates did not differ between the remelted and annealed cohorts (P = 0.28). Oxidation indices were found to be significantly higher in the annealed cohort for all regions of interest (P < 0.001). CONCLUSION: Oxidation was found to be higher in the annealed HXLPE; however, this does not seem to be associated with greater wear, as we found the average penetration rate for the cohort was low, and the penetration rates were similar between the annealed and remelted cohorts.

2.
J Knee Surg ; 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38552644

RESUMEN

Cementless implant use continues to increase primarily due to increased numbers of younger and obese patients opting for primary total knee arthroplasty (TKA). Given the increased use of cementless implants, the purpose of this study was to evaluate the midterm clinical performance of cementless TKA using a highly porous tibial baseplate compared with its cemented counterpart of the same system. We conducted a retrospective case-control study of 400 patients undergoing primary TKA that included 200 patients with cementless components matched for age and body mass index (BMI) to 200 patients with cemented implants of the same implant design with a 5-year follow-up. We evaluated clinical results, complications, revisions, and overall survivorship between the cohorts. Statistical analysis was performed using student t-test and chi-square analysis. There was no statistical difference in age (64.3 vs. 64.3 p = 0.81), BMI (34 vs. 33.1 p = 0.19), preoperative Knee Society Score (KSS) function (41 vs. 32.3 p = 0.22), and preoperative KSS knee score (39.2 vs. 38.3 p = 0.54) between the cementless and cemented cohorts, respectively. The cementless group had seven revisions, while the cemented group had nine revisions (p = 0.609). The cementless group had one revision due to aseptic loosening versus five in the cemented group (p = 0.09). Postoperative 5-year KSS knee scores were 92.84 versus 91.75 (p = 0.386) and function scores were 81.81 versus 69.65 (p = 0.00004) in the cementless and cemented groups, respectively. The cementless group had survivorship of 96.5% for all-cause revision compared with 95.5% in the cemented group at 5-year follow-up (p = 0.60). Cementless TKA using a highly porous tibial baseplate showed excellent midterm results with one case of aseptic loosening at 5-year follow-up and with similar Knee Society outcome scores and survivorship compared with the cemented group. Cementless TKA demonstrated noninferiority to cemented TKA and could be used as an alternative mode of fixation in patients opting for primary TKA. Additional long-term follow-up is needed to determine if cementless TKA can demonstrate improved survivorship over cemented TKA.

3.
Surg Technol Int ; 442024 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-38442247

RESUMEN

Revision total hip arthroplasty (THA) is a procedure with many challenges, especially when patients exhibit femoral bone defects. The causes of these defects vary, ranging from removal of prior implants to aseptic loosening. As surgeons navigate these challenges, a reliable surgical system is important. One modular fluted tapered system provides surgeons with tools to address complex hip revision cases. Introduced in 2003, this system has been utilized in over 180,000 procedures, demonstrating its reliability and effectiveness. Previously, the body stem came in sizes 155mm to 235mm. In the discussed case series, we present six distinct patient cases that highlight the advantages and efficacy of a newly introduced modification of the system; that is the use of smaller stemmed components (now 115mm). With each patient presenting unique challenges, we have demonstrated the use of this new short-stem version for multiple applications for various revision scenarios.

4.
J Arthroplasty ; 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38458333

RESUMEN

BACKGROUND: Total knee arthroplasty (TKA) is one of the most common procedures in orthopaedics, but there is still debate over the optimal fixation method for long-term durability: cement versus cementless bone ingrowth. Recent improvements in implant materials and technology have offered the possibility of cementless TKA to change clinical practice with durable, stable biological fixation of the implants, improved operative efficiency, and optimal long-term results, particularly in younger and more active patients. METHODS: This symposium evaluated the history of cementless TKA, the recent resurgence, and appropriate patient selection, as well as the historical and modern-generation outcomes of each implant (tibia, femur, and patella). Additionally, surgical technique pearls to assist in reliable, reproducible outcomes were detailed. RESULTS: Historically, cemented fixation has been the gold standard for TKA. However, cementless fixation is increasing in prevalence in the United States and globally, with equivalent or improved results demonstrated in appropriately selected patients. CONCLUSIONS: Cementless TKA provides durable biologic fixation and successful long-term results with improved operating room efficiency. Cementless TKA may be broadly utilized in appropriately selected patients, with intraoperative care taken to perform meticulous bone cuts to promote appropriate bony contact and biologic fixation.

5.
J Arthroplasty ; 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38401620

RESUMEN

BACKGROUND: Psychotropic medications are commonly used to treat several mental health conditions. The aim of this study was to determine the impact of psychotropic medications in patients undergoing primary total knee arthroplasty (TKA) with respect to postoperative opioid use, complications, patient-reported outcome measures, and satisfaction. METHODS: This is a retrospective cohort study of 514 consecutive patients undergoing primary TKA. There were 120 patients (23.3%) who were excluded due to preoperative opioid usage. The remaining 394 patients had a minimum 1-year follow-up. Of those, 133 (34%) were on psychotropic medications preoperatively and were compared to the remaining 261 (66%) patients who were not on psychotropics. Clinical data, satisfaction, Knee Society (KS) scores, Western Ontario McMaster Universities Arthritis Index, Patient-Reported Outcomes Measurement Index Score, Forgotten Joint Scores, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, postoperative opioid medication usage, and complications were compared. RESULTS: The study cohort (psychotropic medications) had significantly lower postoperative KS Function, KS Knee, Forgotten Joint Scores, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, Western Ontario McMaster Universities Arthritis Index, and Patient-Reported Outcomes Measurement Index Score compared to the control group. The study group had a lower overall satisfaction score (Likert scale 1 to 5) and a lower percentage of patients either satisfied or very satisfied (4.55 versus 4.79, P < .001; 92.0 versus 97.24%, P = .03, respectively). Postoperative opioid usage was significantly greater in the study group at both 6.4 weeks (range, 4 to 8) and 12-month follow-up (52.76 versus 13.33%, P < .001; 5.51 versus 0.39%, P = .002, respectively). There were no differences in complications and revisions between the groups. CONCLUSIONS: Patients on psychotropic medications should be educated on the risk of increased opioid consumption, diminished satisfaction, and patient-reported outcome measures following primary TKA. Given the large number of patients on psychotropic medications undergoing TKA, additional studies are needed to further improve clinical outcomes in this group.

6.
J Knee Surg ; 37(4): 267-274, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37040872

RESUMEN

Initial design cementless metal-backed patellar implants failed due to multiple reasons including implant design, use of first-generation polyethylene, and surgical technique. This study evaluates clinical outcomes and survivorship of total knee arthroplasty (TKA) using a current generation highly porous metal-backed patellar component. One-hundred twenty-five consecutive primary cementless TKAs with a compression molded highly porous metal-backed patella were reviewed. One-hundred three TKAs (82.4%) with 5-year clinical and radiographic follow-up were available for review. These were matched with 103 consecutive TKAs using a cemented patella of the same implant design. The cementless cohort had a mean age of 65.5 years, body mass index (BMI) of 33.0, and follow-up of 64.4 months. Indications for cementless TKA were based on multiple factors including age, BMI, and bone quality. There were no revisions for loosening or mechanical failure of the cementless patella compared with two cemented patellae revised for aseptic loosening. Eight patients required revisions in the cementless cohort: three for prosthetic joint infection (PJI), two for instability, one periprosthetic femur fracture, one for patella instability, and one for extensor mechanism rupture. Five patients required revisions in the cemented cohort: two for aseptic patellar loosening, one for aseptic femoral loosening, one for PJI, and one for instability. All-cause survivorship at 5 years was 92.2 and 95.1% for the cementless metal-backed implant and cemented implant cohorts, respectively. Use of a compression molded highly porous metal-backed patella component demonstrated excellent clinical and radiographic results at 5-year follow-up. Longer follow-up is required to evaluate the ability of highly porous cementless patella implants to provide durable long-term fixation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Anciano , Rótula/diagnóstico por imagen , Rótula/cirugía , Estudios de Seguimiento , Porosidad , Artroplastia de Reemplazo de Rodilla/métodos , Metales , Reoperación , Diseño de Prótesis , Resultado del Tratamiento , Falla de Prótesis
7.
J Shoulder Elbow Surg ; 33(2): 273-280, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37473905

RESUMEN

BACKGROUND: We sought to compare the complication rates after anatomic total shoulder arthroplasty (aTSA) and reverse shoulder arthroplasty (RSA) for primary glenohumeral arthritis in a Medicare population. METHODS: Patients who underwent a shoulder arthroplasty were identified from the 5% subset of Medicare parts A/B between 2009 and 2019. Patients with less than 1-year follow-up were excluded. A total of 8846 patients with a diagnosis of glenohumeral arthritis were then subdivided into those who received aTSA (5935 patients) and RSA (2911 patients). A multivariate Cox regression analysis was then performed comparing complication rates at 3 months, 6 months, 1 year, 2 years, and 5 years. RESULTS: Statistically significant increased rates of instability (hazard ratio [HR] = 1.46), fracture of the scapula (HR = 7.76), infections (HR = 1.45), early revision (HR = 1.79), and all complications (HR = 1.32) were seen in the RSA group. There was no significant difference in revision rate at 5 years between the 2 groups. There was no difference in patient characteristics or comorbid conditions (smoking status, diabetes, Charlson score, etc.) or hospital characteristics (location, teaching status, public vs. private, etc.) between the 2 groups. CONCLUSION: An increased rate of early complications was observed with the use of RSA compared with aTSA for the treatment of primary glenohumeral arthritis, including instability, scapula fracture, infection, and all cause complication. No difference in revision rate between RSA and aTSA at 5 years was observed.


Asunto(s)
Artritis , Artroplastía de Reemplazo de Hombro , Complicaciones Posoperatorias , Anciano , Humanos , Artritis/cirugía , Artroplastía de Reemplazo de Hombro/efectos adversos , Artroplastía de Reemplazo de Hombro/métodos , Medicare , Rango del Movimiento Articular , Fracturas del Hombro/epidemiología , Resultado del Tratamiento , Estados Unidos/epidemiología , Complicaciones Posoperatorias/epidemiología
8.
Bone Joint J ; 105-B(12): 1279-1285, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38035601

RESUMEN

Aims: The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design. Methods: This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m2 (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions. Results: A total of 24 TKAs (3.4%) in 24 patients failed and required revision surgery, of which five were due to patellar complications (0.71%): one for aseptic patellar loosening (0.14%) and four for polyethylene dissociation (0.57%). A total of 19 revisions (2.7%) were undertaken in 19 patients for indications which did not relate to the patella: four for aseptic tibial loosening (0.57%), one for aseptic femoral loosening (0.14%), nine for periprosthetic infection (1.3%), one for popliteus impingement (0.14%), and four for instability (0.57%). Knee Society knee and function scores, and ROM, improved significantly when comparing pre- and postoperative values. Survival of the metal-backed patellar component for all-cause failure was 97.5% (95% confidence interval 94.9% to 100%) at 12 years. Conclusion: The second-generation cementless TKA design of metal-backed patellar components showed a 97.5% survival at 12 years, with polyethylene dissociation from the metal-backing being the most common cause of patellar failure. In view of the increased use of TKA, especially in younger, more active, or obese patients, these findings are encouraging at mean follow-up of seven years.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Masculino , Femenino , Humanos , Persona de Mediana Edad , Artroplastia de Reemplazo de Rodilla/métodos , Rótula/cirugía , Diseño de Prótesis , Reoperación , Metales , Polietileno , Falla de Prótesis , Estudios de Seguimiento , Resultado del Tratamiento
9.
Ann Transl Med ; 11(10): 349, 2023 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-37675300

RESUMEN

Background: The use of cementless femoral stems in patients undergoing primary total hip arthroplasty (THA) with Dorr C bone remains controversial for fear of fracture or subsidence. Purpose of this multicenter study was to compare clinical outcomes and complications of THA using a tapered femoral prosthesis in patients with Dorr C bone versus Dorr A/B bone. Methods: A total of 1,030 patients underwent primary THA with a tapered wedge femoral stem at a minimum one year follow up. Forty-eight patients with Dorr C bone (mean age 68.7 years) were compared with a matched cohort of patients with Dorr A/B bone (mean age 69.9 years). Mean follow-up was approximately 4 years in both cohorts. There were no differences in sex, age, body mass index (BMI), Harris Hip Score (HHS), complications, and radiographic outcomes including subsidence and aseptic loosening were evaluated. Results: Postoperative HHSs were a mean of 82 points in the Dorr C cohort compared to 84 points in the Door A/B cohort (P=0.2653). There was no significant difference in complication or revision rates for any reason (P=0.23). Mean subsidence for the Dorr C and Dorr A/B was 1.4 and 1.2 mm, respectively (P=0.5164), and there was no aseptic loosening of the femoral component found in either group. Conclusions: Current generation tapered wedge cementless femoral stems provide stable fixation for patients with Dorr C bone quality without increased complications with respect to fracture or subsidence and can be considered an alternative to cemented stems in patients with compromised bone quality.

10.
Arthroplast Today ; 22: 101169, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37521737

RESUMEN

Background: Patient satisfaction and patient-reported outcome measures (PROMs) are important for patients, surgeons, and payers in the current healthcare climate. Morbidly obese patients (body mass index [BMI] >40) have demonstrated higher incidence of complications after total knee arthroplasty (TKA) and can have difficulty obtaining access for their surgical care. The purpose of this study was to evaluate PROMs and patient satisfaction in morbidly obese patients undergoing primary TKA. Methods: A total of 75 patients with BMI >40 kg/m2 undergoing robotic-assisted TKA were retrospectively identified and matched 2:1 to a consecutive cohort of patients with BMI <35. The average BMI of the study cohort was 42.4 kg/m2 (39.5-51.3) compared to 28.6 kg/m2 (18.5-34.9) in the control group. Clinical outcomes, PROMs, and patient satisfaction were evaluated at a minimum 2-year follow-up. Results: The patients of the BMI >40 cohort were less likely to be discharged home (P = .0076), had less active flexion at 2 years (P = .0046), and had worse knee scores at 2 years (0.0497). Despite this, the percentage of patients who were satisfied or very satisfied after surgery was similar between the groups (87.5% vs 91.2%, P = .1943). Conclusions: Morbidly obese patients are less likely to be discharged directly to home and may have functional differences after primary TKA. However, morbidly obese patients have similar PROMs and are as satisfied as nonobese patients at 2 years. Morbidly obese patients with end-stage knee osteoarthritis should also be able to enjoy the benefits of primary TKA following medical and surgical optimization.

11.
J Bone Joint Surg Am ; 2023 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-37192280

RESUMEN

BACKGROUND: Recent advances in high-throughput DNA sequencing technologies have made it possible to characterize the microbial profile in anatomical sites previously assumed to be sterile. We used this approach to explore the microbial composition within joints of osteoarthritic patients. METHODS: This prospective multicenter study recruited 113 patients undergoing hip or knee arthroplasty between 2017 and 2019. Demographics and prior intra-articular injections were noted. Matched synovial fluid, tissue, and swab specimens were obtained and shipped to a centralized laboratory for testing. Following DNA extraction, microbial 16S-rRNA sequencing was performed. RESULTS: Comparisons of paired specimens indicated that each was a comparable measure for microbiological sampling of the joint. Swab specimens were modestly different in bacterial composition from synovial fluid and tissue. The 5 most abundant genera were Escherichia, Cutibacterium, Staphylococcus, Acinetobacter, and Pseudomonas. Although sample size varied, the hospital of origin explained a significant portion (18.5%) of the variance in the microbial composition of the joint, and corticosteroid injection within 6 months before arthroplasty was associated with elevated abundance of several lineages. CONCLUSIONS: The findings revealed that prior intra-articular injection and the operative hospital environment may influence the microbial composition of the joint. Furthermore, the most common species observed in this study were not among the most common in previous skin microbiome studies, suggesting that the microbial profiles detected are not likely explained solely by skin contamination. Further research is needed to determine the relationship between the hospital and a "closed" microbiome environment. These findings contribute to establishing the baseline microbial signal and identifying contributing variables in the osteoarthritic joint, which will be valuable as a comparator in the contexts of infection and long-term arthroplasty success. LEVEL OF EVIDENCE: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.

12.
J Arthroplasty ; 38(7S): S89-S94.e1, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37088227

RESUMEN

BACKGROUND: Instability has been the primary cause of failure following primary total hip arthroplasty (THA) leading to revision hip surgery. The purpose of this study was to determine if instability rates have further declined following advances in primary THA, including dual mobility articulations, direct anterior approaches, advanced technologies, and improved knowledge of the hip-spine relationships. METHODS: Using the 5% Medicare Part B claims data from 1999 to 2019, we identified 81,573 patients who underwent primary THA for osteoarthritis. Patients who experienced instability at 3 months, 6 months, 1 year, and 2 years were identified. Multivariate cox regression analyses evaluated the effect of patient and procedure characteristics on the risk of instability. RESULTS: Instability at 1 year following primary THA declined from approximately 4% in 2000 to 2.3% in 2010 and 1.6% in 2018. The leading cause of revision surgery was infection (18.6%), followed by periprosthetic fracture (14%), mechanical loosening (11.5%), and instability (9.4%). High-risk groups for instability continue to include increased age, higher Charlson index, obesity, lumbar spine pathology, and neurocognitive disorders. CONCLUSION: Instability is no longer the leading etiology of failure following primary THA with a decline of approximately 40% over the past decade. Infection, periprosthetic fracture, mechanical loosening, and then instability are now the leading causes of failure. Multiple factors may play a role in the decline of instability, including increased use of dual mobility articulations, direct anterior approaches, improved knowledge of the hip-spine relationships, and use of advanced technologies.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Fracturas Periprotésicas , Humanos , Anciano , Estados Unidos/epidemiología , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Fracturas Periprotésicas/complicaciones , Incidencia , Falla de Prótesis , Medicare , Reoperación/efectos adversos , Factores de Riesgo , Prótesis de Cadera/efectos adversos , Estudios Retrospectivos , Luxación de la Cadera/etiología
13.
J Arthroplasty ; 38(6S): S137-S144, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36791887

RESUMEN

BACKGROUND: Historically, 1st generation metal-backed cementless patellar implants demonstrated high failure rates due to multiple factors. The 2nd generation cementless implants were developed with purported improvements in component design and polyethylene wear characteristics. This study evaluated clinical results of a current generation cementless metal-backed patellar implant with a minimum 5-year follow-up. METHODS: One hundred and thirty-six primary total knee arthroplasties (TKAs) with metal-backed cementless patellae were compared to 183 cemented patellae with the same implant design. The cementless group mean age was 61 years (range, 40 to 81), mean body mass index (BMI) of 34.9 (range, 22.6 to 64.5), and mean follow-up of 10 years (range, 5 to 13). The cemented group mean age was 65 years (range, 32 to 89), mean BMI of 32.5 (range, 18.2 to 56.6), and mean follow-up of 10 years (range, 5 to 12). Significant demographic differences of age (P < .001), BMI (P < .01), and sex (P < .001) were found, with cementless patients being younger, heavier, and with more men. RESULTS: There were no statistical differences in non-revision procedures (P = .214), TKA revisions (P = .639), patellar revisions (P = .151), and patellar aseptic loosening (P = .737). The 10-year survivorship of the cementless metal-backed patella was 95.9% with all-cause failure as the endpoint. The 10-year survivorship of the cemented patellar component was 98.9%. CONCLUSION: This study demonstrated noninferiority of a 2nd generation HA-coated cementless metal-backed patellar implant in primary TKA compared to cemented patellae with 10-year survivorship of 95.9%. Advances in implant design and polyethylene wear properties have led to improved clinical results with metal-backed patellar components in primary TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Rótula , Anciano , Humanos , Masculino , Persona de Mediana Edad , Artroplastia de Reemplazo de Rodilla/métodos , Estudios de Seguimiento , Metales , Rótula/cirugía , Polietileno , Diseño de Prótesis , Falla de Prótesis , Reoperación , Resultado del Tratamiento
14.
J Am Acad Orthop Surg ; 31(5): e271-e277, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36728665

RESUMEN

INTRODUCTION: Patients undergoing primary total hip arthroplasty (THA) with a previous history of lumbar spine fusion (LSF) are at increased risk of dislocation. The purpose of this study was to compare the 90-day and 1-year dislocation rates of patients with LSF or lumbar degenerative disk disease who underwent primary THA with and without dual mobility (DM) constructs. METHODS: An American Joint Replacement Registry data set of patients aged 65 years and older undergoing primary THA with minimum 1-year follow-up with a history of prior LSF or a diagnosis of lumbar degenerative disk disease was created. DM status was identified, and dislocation and all-cause revision at 90 days and 1 year were assessed. RESULTS: A total of 15,572 patients met study criteria. The overall dislocation rates for the non-DM and DM groups were 1.17% and 0.68%, respectively, at 90 days, and 1.68% and 0.91%, respectively, at 1 year ( P = 0.005). The odds of 90-day (OR = 0.578, [ P = 0.0328]) and 1-year (OR = 0.534, [ P = 0.0044]) dislocation were significantly less with DM constructs, compared with non-DM constructs. No statistically significant difference was observed in revision rates between groups. DISCUSSION: This large registry-based study identified a reduced risk of dislocation in patients at risk for spinal stiffness when a DM compared with non-DM construct was used in primary THA at 90-day and 1-year follow-up intervals. Our data support the use of DM constructs in high-risk patients with stiff spines and altered spinopelvic mobility as a promising option to mitigate the risk of postoperative hip instability after primary THA. LEVELS OF EVIDENCE: Level III. Therapeutic retrospective cohort.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Degeneración del Disco Intervertebral , Luxaciones Articulares , Humanos , Estados Unidos , Artroplastia de Reemplazo de Cadera/efectos adversos , Luxación de la Cadera/etiología , Estudios Retrospectivos , Reoperación/efectos adversos , Luxaciones Articulares/cirugía , Degeneración del Disco Intervertebral/complicaciones , Sistema de Registros , Prótesis de Cadera/efectos adversos , Diseño de Prótesis , Falla de Prótesis
15.
Orthopedics ; 46(2): e111-e117, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36476288

RESUMEN

Highly cross-linked polyethylene (HXLPE) has become the preferred bearing surface in total hip arthroplasty. However, its acceptance in total knee arthroplasty (TKA) has not been as robust because of concerns pertaining to wear and its impact on implant failure. Therefore, this multicenter study was purposed to evaluate the 10-year (1) radiographic outcomes; (2) complications; and (3) implant survivorship in patients with TKA receiving a sequentially irradiated and annealed HXLPE. A retrospective, multi-center study was performed on 139 patients (171 TKAs) who underwent primary TKA with HXLPE and possessed a minimum of 10-year follow-up. Radiographs were analyzed for radiolucencies along the implant-fixation interface using the Modern Knee Society Radiographic Evaluation System. Kaplan-Meier analysis determined implant survivorship when the end points were revision for polyethylene wear and polyethylene revision for any reason. Sixteen TKAs (9.9%) demonstrated periprosthetic linear radio-lucencies. Seventeen TKAs (9.9%) required additional surgeries, 9 (5.3%) of which were revisions, with 1 (0.6%) TKA requiring revision because of polyethylene wear. Other causes of revision included instability (1.8%), infection (1.6%), and arthrofibrosis (1.6%). The mean time to revision was 5.9 years (range, 0.1-11.1 years). Survivorship pertaining to polyethylene revision for wear was 99.4%, whereas all-cause polyethylene revision was 94.7%. This study in patients undergoing primary TKA using a second-generation HXLPE demonstrated excellent results with respect to polyethylene wear characteristics and strength with a 99.4% survivorship at 10 years. [Orthopedics. 2023;46(2):e111-e117.].


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Polietileno , Estudios Retrospectivos , Estudios de Seguimiento , Falla de Prótesis , Diseño de Prótesis , Reoperación
16.
J Knee Surg ; 36(9): 995-1000, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35679852

RESUMEN

Morbidly obese patients undergoing cemented primary total knee arthroplasty (TKA) can pose a challenging problem with implant survivorship due to greater stress at the cement-bone interface. With the advent of additive manufacturing (three-dimensional printing), highly porous implants are now readily available. The purpose of this study was to review the results of primary TKA in the morbidly obese (body mass index [BMI] ≥ 40) patient using a highly porous cementless tibial baseplate. This is a retrospective study of 167 TKAs in patients with morbid obesity undergoing primary cementless TKA with a minimum 5-year follow-up. A total of 6 patients died and 14 were lost to follow-up, leaving 147 TKAs in 136 patients with a mean follow-up of 66 months (range 60-79 months). The average age was 59 years (range 36-84 years) and average BMI was 45 kg/m2 (range 39.5-63.9). Clinical results, patient-reported outcome measures, radiographs, and complications were reviewed. There were 9 failures requiring revision, including 3 for aseptic tibial loosening (2.0%), 2 for deep infection (1.4%), 2 for patellar resurfacing (1.4%), 1 for patella instability (0.7%), and 1 for extensor mechanism rupture (0.7%). Knee Society Score (KSS) improved from 48 to 90 at 2- and 5-year follow-up. KSS function score improved from 49 to 68 and 79 at 2- and 5-year follow-up, respectively. Survivorship with aseptic loosening as the endpoint was 98.0% at 5 years. Cementless TKA using a highly porous tibial baseplate in morbidly obese patients demonstrated excellent clinical results with 98% survivorship at 5 years and appears to offer durable long-term biologic fixation as an alternative to mechanical cement fixation in this challenging group of patients.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Obesidad Mórbida , Humanos , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/métodos , Obesidad Mórbida/complicaciones , Obesidad Mórbida/cirugía , Estudios Retrospectivos , Estudios de Seguimiento , Porosidad , Reoperación , Diseño de Prótesis , Cementos para Huesos , Falla de Prótesis , Resultado del Tratamiento
17.
J Knee Surg ; 36(13): 1374-1379, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36116441

RESUMEN

Chronic opioid use prior to total knee arthroplasty (TKA) has been implicated in adverse outcomes. The purpose of this study was to evaluate clinical outcome measures and patient satisfaction in patients with a history of preoperative chronic opioid use undergoing primary TKA. A retrospective cohort study was performed on 296 consecutive patients undergoing primary TKA. Seventy-four (25%) patients were identified with chronic preoperative opioid use (study group; 22 males, 52 females). A 3:1 matched cohort ratio of control versus study group was utilized resulting in a control group consisting of 222 patients (97 males, 125 females) without chronic opioid use prior to surgery. There was no statistically significant difference in age, BMI, or follow-up. Average follow-up was 23.4 months in the control group and 23.6 months in the study group (p = 0.87). Clinical data including patient satisfaction (Likert score), Knee Society (KS) Knee scores, KS Function scores, Forgotten Joint Score (FJS), length of stay (LOS), and complications were evaluated. Patient satisfaction at the most recent visit was 92.8% in the control group versus 83.8% in the chronic opioid group (p = 0.0016). Differences in patient-reported outcomes measures comparing the control and study cohorts included KS Function Score of 83.23 versus 75.31 (p = 0.0034). The FJS of 63.7 versus 58 (p = 0.1883) and the KS Knee Score of 89.5 versus 88.1 (p = 0.4075) were not significant. Postoperative opioid usage for the control versus the study group was 62/222 (27.9%) versus 56/74 (75.7%) at 4 to 8 weeks (p <0.0001), and 4/222 (1.80%) versus 27/74 (36.5%) at 12 months (p <0.0001). Overall complication occurrence was 18.9% in the study group versus 11.3% in the control group (p = 0.11). Patients with history of chronic preoperative opioid use had significantly lower patient satisfaction and KS Function scores and increased postoperative opioid usage at 12 months compared with patients without a history of opioid use prior to TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Trastornos Relacionados con Opioides , Osteoartritis de la Rodilla , Masculino , Femenino , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Satisfacción del Paciente , Analgésicos Opioides/uso terapéutico , Estudios Retrospectivos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Resultado del Tratamiento
18.
J Arthroplasty ; 38(3): 567-572.e1, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36191695

RESUMEN

BACKGROUND: Stiffness following total knee arthroplasty (TKA) is a disabling complication and manipulation under anesthesia (MUA) is often performed as an early intervention. Few studies have focused on the revision risk, infection risk, demographics, and clinical outcomes in Medicare patients undergoing MUA following primary TKA. METHODS: We reviewed 142,440 patients who had primary TKA from a national database and identified 3,652 patients (2.6%) who underwent MUA. Patient demographics and comorbid conditions were evaluated to identify risk factors. Incidence of revision and periprosthetic joint infection (PJI) at 1-, 2-, and 5-year time points in a cohort of MUA patients was compared to patients who did not undergo MUA. Multivariate Cox regressions were used for statistical analyses. RESULTS: The incidence of MUA was higher in Black versus White individuals (4.1 versus 2.5%, P < .001). Revision risk was significantly greater in the MUA group at 1-, 2-, and 5-year time points with a hazard ratio (HR) of, 3.81, 3.90, and 3.22 respectively, P < .001. One- and 2-year revision risk was significantly greater when MUA occurred at 6 to 12 months post-TKA when compared to <3 months, P < .05. Risk of PJI was significantly greater in the MUA group with a HR of 2.2, 2.2, and 2.1 at 1, 2, and 5 years, respectively P < .001. CONCLUSION: The incidence of MUA was 2.6%. There was an increased incidence of revision surgery and PJI in patients undergoing MUA. Patients at increased risk for stiffness following TKA should be closely monitored and treated with early intervention to minimize risk of poor outcomes.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Rodilla , Humanos , Anciano , Estados Unidos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Articulación de la Rodilla/cirugía , Medicare , Factores de Riesgo , Incidencia , Artritis Infecciosa/etiología , Estudios Retrospectivos , Reoperación
19.
J Arthroplasty ; 38(3): 484-490, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36122689

RESUMEN

BACKGROUND: Alternative alignment concepts have garnered great interest in an effort to improve patient satisfaction following primary total knee arthroplasty (TKA). The purpose of this study is to determine variation or deviation from an individual's native joint line in primary TKA using neutral mechanical versus a restricted kinematic technique. METHODS: An institutional review board-approved prospective cohort study was performed evaluating the effect of neutral mechanical alignment (nMA) versus a restricted kinematic alignment (rKA) on the native joint line in 100 consecutive patients undergoing primary TKA. Using preoperative computed tomography and intraoperative 3-dimensional software, 2 virtual preoperative plans were created: nMA and rKA. Templated bone resections were recorded. Change in joint line was calculated using known implant planar thickness and planned bone resection. RESULTS: nMA yielded significantly greater deviation from the patient's native joint line along the lateral compartment of the knee (lateral distal femoral condyle, lateral posterior femoral condyle, lateral tibial resection). With nMA, the lateral distal femoral joint line was distalized by a mean 4.3 versus 2.6 mm using rKA technique (P < .001). In rKA, >60% of knees had <3 mm of deviation from the native lateral posterior femoral offset, whereas in nMA, >95% of knees had ≥3 mm change in the lateral posterior femoral condylar offset. CONCLUSION: nMA-TKA resulted in statistically larger joint line deviations compared to rKA-TKA, most notably along the lateral distal femoral condyle joint line. Further analysis is needed to determine the clinical consequences of joint line deviation from the native anatomy using nMA as the target for primary TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Prospectivos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Fémur/diagnóstico por imagen , Fémur/cirugía , Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Fenómenos Biomecánicos
20.
Surg Technol Int ; 412022 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-36450147

RESUMEN

Highly porous metaphyseal cones have proven useful in revision total knee arthroplasty in providing surgeons with improved metaphyseal fixation when large contained and uncontained bony defects are encountered. In this case series, we demonstrate three patients who received the latest generation of metaphyseal cones. Specifically, these cases will highlight this new system description and its operative techniques as well as the indications for metaphyseal cone use with various real-world applications. These newer-generation porous-coated cones are excellent options for large bone defects in the absence of infection, providing adequate metaphyseal fixation without constraining final implant positioning.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...