Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Heart ; 110(2): 87-93, 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-37438054

RESUMEN

As the population ages and treatment options for heart valve disease increase, the number of patients with intracardiac valve prostheses is growing rapidly. Although all devices have the potential to cause thrombus formation, the propensity depends on the type of prosthesis as well as risk of the individual patient. Mechanical valve prostheses carry the highest (and persistent) risk of thromboembolism, and these patients require anticoagulation with vitamin K antagonists (warfarin). Required international normalised ratio levels are dependent on the location of the valve (mitral>aortic), type of valve (ball and cage vs bilealfet vs On-X bilealfet) and rhythm. The risk of tissue (biological) prosthesis is highest soon after surgery and is dependent on individual patient risk including age, valve location (mitral>aortic), history of thromboembolic events and rhythm. In patients with no other indication for anticoagulation, there is uncertainty on the benefits of anticoagulation versus antiplatelet therapy in patients with tissue prostheses or repaired native valves. Patients with an a priori indication for anticoagulation with a direct oral anticoagulant can continue taking this class of drug. Patients with transcatheter aortic valve implantation devices and no additional evidence-based indication for dual antiplatelet therapy or anticoagulation can be maintained on aspirin monotherapy. Patients undergoing transcatheter instrumentation in the mitral valve position should be anticoagulated, although there is currently no published evidence for antithrombotic management in this group of patients. Patients with thrombosed devices (commonly mitral mechanical) should preferably be treated surgically. Patients at high risk of thromboembolism (with mechanical prostheses) should undergo bridging therapy when undergoing surgery.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Tromboembolia , Trombosis , Humanos , Fibrinolíticos/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Anticoagulantes/efectos adversos , Tromboembolia/etiología , Tromboembolia/prevención & control , Trombosis/etiología , Trombosis/prevención & control , Trombosis/tratamiento farmacológico , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/cirugía , Válvula Aórtica/cirugía
2.
Monaldi Arch Chest Dis ; 94(1)2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37074089

RESUMEN

This study sought to compare the morbidity and mortality of redo aortic valve replacement (redo-AVR) versus valve-in-valve trans-catheter aortic valve implantation (valve-in-valve TAVI) for patients with a failing bioprosthetic valve. A multicenter UK retrospective study of redo-AVR or valve-in-valve TAVI for patients referred for redo aortic valve intervention due to a degenerated aortic bioprosthesis. Propensity score matching was performed for confounding factors. From July 2005 to April 2021, 911 patients underwent redo-AVR and 411 patients underwent valve-in-valve TAVI. There were 125 pairs for analysis after propensity score matching. The mean age was 75.2±8.5 years. In-hospital mortality was 7.2% (n=9) for redo-AVR versus 0 for valve-in-valve TAVI, p=0.002. Surgical patients suffered more post-operative complications, including intra-aortic balloon pump support (p=0.02), early re-operation (p<0.001), arrhythmias (p<0.001), respiratory and neurological complications (p=0.02 and p=0.03) and multi-organ failure (p=0.01). The valve-in-valve TAVI group had a shorter intensive care unit and hospital stay (p<0.001 for both). However, moderate aortic regurgitation at discharge and higher post-procedural gradients were more common after valve-in-valve TAVI (p<0.001 for both). Survival probabilities in patients who were successfully discharged from the hospital were similar after valve-in-valve TAVI and redo-AVR over the 6-year follow-up (log-rank p=0.26). In elderly patients with a degenerated aortic bioprosthesis, valve-in-valve TAVI provides better early outcomes as opposed to redo-AVR, although there was no difference in mid-term survival in patients successfully discharged from the hospital.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/cirugía , Catéteres , Reino Unido/epidemiología , Resultado del Tratamiento , Factores de Riesgo , Bioprótesis/efectos adversos
3.
Echo Res Pract ; 10(1): 4, 2023 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-36882790

RESUMEN

BACKGROUND: The prevalence, clinical characteristics, management and long-term outcomes of patients with atrial secondary mitral regurgitation (ASMR) are not well described. METHODS: We performed a retrospective, observational study of consecutive patients with grade III/IV MR determined by transthoracic echocardiography. The aetiology of MR was grouped as being either primary (due to degenerative mitral valve disease), ventricular SMR (VSMR: due to left ventricular dilatation/dysfunction), ASMR (due to LA dilatation), or other. RESULTS: A total of 388 individuals were identified who had grade III/IV MR; of whom 37 (9.5%) had ASMR, 113 (29.1%) had VSMR, 193 had primary MR (49.7%), and 45 (11.6%) were classified as having other causes. Compared to MR of other subtypes, patients with ASMR were on average older (median age 82 [74-87] years, p < 0.001), were more likely to be female (67.6%, p = 0.004) and usually had atrial fibrillation (83.8%, p = 0.001). All-cause mortality was highest in patients with ASMR (p < 0.001), but similar to that in patients with VSMR once adjusted for age and sex (hazard ratio [HR] 0.81, 95% confidence interval [CI] 0.52-1.25). Hospitalisation for worsening heart failure was more commonly observed in those with ASMR or VSMR (p < 0.001) although was similar between these groups when age and sex were accounted for (HR 0.74, 95% CI 0.34-1.58). For patients with ASMR, the only variables associated with outcomes were age and co-morbidities. CONCLUSIONS: ASMR is a prevalent and distinct disease process associated with a poor prognosis, with much of this related to older age and co-morbidities.

4.
Catheter Cardiovasc Interv ; 101(5): 932-942, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36924015

RESUMEN

BACKGROUND: With expansion of transcatheter aortic valve implantation (TAVI) into younger patients, valve durability is critically important. AIMS: We aimed to evaluate long-term valve function and incidence of severe structural valve deterioration (SVD) among patients ≥ 10-years post-TAVI and with echocardiographic follow-up at least 5-years postprocedure. METHODS: Data on patients who underwent TAVI from 2007 to 2011 were obtained from the UK TAVI registry. Patients with paired echocardiograms postprocedure and ≥5-years post-TAVI were included. Severe SVD was determined according to European task force guidelines. RESULTS: 221 patients (79.4 ± 7.3 years; 53% male) were included with median echocardiographic follow-up 7.0 years (range 5-13 years). Follow-up exceeded 10 years in 43 patients (19.5%). Valve types were the supra-annular self-expanding CoreValve (SEV; n = 143, 67%), balloon-expandable SAPIEN/XT (BEV; n = 67, 31%), Portico (n = 4, 5%) and unknown (n = 7, 3%). There was no difference between postprocedure and follow-up peak gradient in the overall cohort (19.3 vs. 18.4 mmHg; p = NS) or in those with ≥10-years follow-up (21.1 vs. 21.1 mmHg; p = NS). Severe SVD occurred in 13 patients (5.9%; median 7.8-years post-TAVI). Three cases (23.1%) were due to regurgitation and 10 (76.9%) to stenosis. Valve-related reintervention/death occurred in 5 patients (2.3%). Severe SVD was more frequent with BEV than SEV (11.9% vs. 3.5%; p = 0.02), driven by a difference in patients treated with small valves (BEV 28.6% vs. SEV 3.0%; p < 0.01). CONCLUSIONS: Hemodynamic function of transcatheter heart valves remains stable up to more than 10 years post-TAVI. Severe SVD occurred in 5.9%, and valve-related death/reintervention in 2.3%. Severe SVD was more common with BEV than SEV.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Sistema de Registros , Reino Unido , Diseño de Prótesis
5.
Open Heart ; 9(2)2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36192035

RESUMEN

BACKGROUND: There is a paucity of real-world data assessing the association of operator volumes and mortality specific to primary percutaneous coronary intervention (PPCI). METHODS: Demographic, clinical and outcome data for all patients undergoing PPCI in Leeds General Infirmary, UK, between 1 January 2009 and 31 December 2011, and 1 January 2013 and 31 December 2013, were obtained prospectively. Operator volumes were analysed according to annual operator PPCI volume (low volume: 1-54 PPCI per year; intermediate volume: 55-109 PPCI per year; high volume: ≥110 PPCI per year). Cox proportional hazards regression analyses were undertaken to investigate 30-day and 12-month all-cause mortality, adjusting for confounding factors. RESULTS: During this period, 4056 patients underwent PPCI, 3703 (91.3%) of whom were followed up for a minimum of 12 months. PPCI by low-volume operators was associated with significantly higher adjusted 30-day mortality (HR 1.48 (95% CI 1.05 to 2.08); p=0.02) compared with PPCI performed by high-volume operators, with no significant difference in adjusted 12-month mortality (HR 1.26 (95% CI 0.96 to 1.65); p=0.09). Comparisons between low-volume and intermediate-volume operators, and between intermediate and high-volume operators, showed no significant differences in 30-day and 12-month mortality. CONCLUSIONS: Low operator volume is independently associated with higher probability of 30-day mortality compared with high operator volume, suggesting a volume-outcome relationship in PPCI at a threshold higher than current recommendations.


Asunto(s)
Infarto del Miocardio , Intervención Coronaria Percutánea , Mortalidad Hospitalaria , Humanos , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
6.
BMC Cardiovasc Disord ; 22(1): 450, 2022 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-36307769

RESUMEN

Very short duration of dual antiplatelet therapy (DAPT) following percutaneous coronary intervention (PCI) has recently attracted a lot of attention with the introduction of newer generations stents. This is appealing, especially in patients at high bleeding risk. However, none of the trials were powered for the individual ischemic and bleeding endpoints. All randomised controlled trials (RCTs) investigating one-month versus routine duration of DAPT in patients undergoing PCI and reporting outcomes from the time of cessation of DAPT (1 month) to 1 year were eligible for inclusion in the meta-analysis. The pooled risk ratios (RR) with their 95% confidence interval (CI) were calculated with the random-effects model using the Mantel-Haenszel method. Four RCTs involving 26,576 patients were included in this meta-analysis. Cessation of DAPT after 1 month was associated with significantly less major bleeding [RR 0.70, 95%CI (0.51-0.95), P = 0.02, heterogeneity (I2) = 42%]. There was no statistically significant difference in all-cause mortality [RR 0.84 (95%CI 0.69-1.03), P = 0.10, I2 = 0%] and stroke [RR 0.71 (95%CI 0.45-1.13), P = 0.15, I2 = 42%] when compared to routine duration of DAPT. There was also no difference in myocardial infarction (MI) [RR 1.12 (95%CI 0.91-1.39), P = 0.28, I2 = 0%], and definite or probable stent thrombosis [RR 1.49 (95%CI 0.92-2.41), P = 0.11, I2 = 0%] with cessation of DAPT after 1 month. Cessation of DAPT 1 month after PCI was associated with significantly less major bleeding, but there was no difference in the rate of all-cause mortality, stroke, MI and stent thrombosis.


Asunto(s)
Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria , Humanos , Quimioterapia Combinada , Hemorragia/inducido químicamente , Infarto del Miocardio , Inhibidores de Agregación Plaquetaria/efectos adversos , Ensayos Clínicos Controlados Aleatorios como Asunto , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Trombosis/prevención & control , Trombosis/inducido químicamente , Resultado del Tratamiento
7.
JAMA ; 327(19): 1875-1887, 2022 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-35579641

RESUMEN

Importance: Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical aortic valve replacement and is the treatment of choice for patients at high operative risk. The role of TAVI in patients at lower risk is unclear. Objective: To determine whether TAVI is noninferior to surgery in patients at moderately increased operative risk. Design, Setting, and Participants: In this randomized clinical trial conducted at 34 UK centers, 913 patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk due to age or comorbidity were enrolled between April 2014 and April 2018 and followed up through April 2019. Interventions: TAVI using any valve with a CE mark (indicating conformity of the valve with all legal and safety requirements for sale throughout the European Economic Area) and any access route (n = 458) or surgical aortic valve replacement (surgery; n = 455). Main Outcomes and Measures: The primary outcome was all-cause mortality at 1 year. The primary hypothesis was that TAVI was noninferior to surgery, with a noninferiority margin of 5% for the upper limit of the 1-sided 97.5% CI for the absolute between-group difference in mortality. There were 36 secondary outcomes (30 reported herein), including duration of hospital stay, major bleeding events, vascular complications, conduction disturbance requiring pacemaker implantation, and aortic regurgitation. Results: Among 913 patients randomized (median age, 81 years [IQR, 78 to 84 years]; 424 [46%] were female; median Society of Thoracic Surgeons mortality risk score, 2.6% [IQR, 2.0% to 3.4%]), 912 (99.9%) completed follow-up and were included in the noninferiority analysis. At 1 year, there were 21 deaths (4.6%) in the TAVI group and 30 deaths (6.6%) in the surgery group, with an adjusted absolute risk difference of -2.0% (1-sided 97.5% CI, -∞ to 1.2%; P < .001 for noninferiority). Of 30 prespecified secondary outcomes reported herein, 24 showed no significant difference at 1 year. TAVI was associated with significantly shorter postprocedural hospitalization (median of 3 days [IQR, 2 to 5 days] vs 8 days [IQR, 6 to 13 days] in the surgery group). At 1 year, there were significantly fewer major bleeding events after TAVI compared with surgery (7.2% vs 20.2%, respectively; adjusted hazard ratio [HR], 0.33 [95% CI, 0.24 to 0.45]) but significantly more vascular complications (10.3% vs 2.4%; adjusted HR, 4.42 [95% CI, 2.54 to 7.71]), conduction disturbances requiring pacemaker implantation (14.2% vs 7.3%; adjusted HR, 2.05 [95% CI, 1.43 to 2.94]), and mild (38.3% vs 11.7%) or moderate (2.3% vs 0.6%) aortic regurgitation (adjusted odds ratio for mild, moderate, or severe [no instance of severe reported] aortic regurgitation combined vs none, 4.89 [95% CI, 3.08 to 7.75]). Conclusions and Relevance: Among patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk, TAVI was noninferior to surgery with respect to all-cause mortality at 1 year. Trial Registration: isrctn.com Identifier: ISRCTN57819173.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
8.
J Invasive Cardiol ; 33(10): E761-E768, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34521771

RESUMEN

OBJECTIVES: To assess the impact of balloon use for predilation, valve implantation, or postdilation on in-hospital mortality among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR utilizes self-expanding, mechanically expanding, or balloon-expandable valves. Balloon inflation is inherent to deployment of balloon-expandable valves. Balloons may additionally be used with all valve types for pre- and postdilation. The relationships between valve mechanism, balloon use, and in-hospital mortality are not fully characterized. METHODS: Prospective data were collected on 4063 patients undergoing TAVR for aortic stenosis at 4 high-volume centers in the United Kingdom. In-hospital mortality was analyzed according to valve expansion mechanism, use of balloons for pre- and postdilation, and specific cause of death. RESULTS: Mean patient age was 83 ± 8 years. Implanted valves were self expanding (n = 2241; 55%), mechanically expanding (n = 1092; 27%), or balloon expandable (n = 727; 18%). In-hospital death occurred in 66 cases (1.6%). Thirty-six deaths (54.5%) were classified as implantation-related mortalities, with rates of 0.8%, 0.5%, and 1.7% (P=.04) among self-expanding, mechanically expanding, and balloon-expandable technologies, respectively. Patients who underwent balloon inflation at any stage of their procedure (n = 2556; 63%) had significantly higher implantation-related mortality than those who did not (1.3% vs 0.3%, respectively; P<.01). Balloon-expandable valve procedures were associated with significantly higher all-cause mortality (2.6% vs 1.4%; P=.02) and implantation-related mortality (1.7% vs 0.7%; P=.02) than non-balloon-expandable valve procedures. Balloon-related complications accounted for 18 cases (26%) of total in-hospital mortality, including all 12 cases (17.4%) of annular rupture and 5 cases (7.2%) of coronary occlusion. CONCLUSIONS: Balloon use for predilation, valve implantation, or postdilation was associated with an increased mortality risk. Balloon-related complications were the largest contributor to in-hospital mortality, comprising all cases of annular rupture and the majority of coronary occlusion cases.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Mortalidad Hospitalaria , Humanos , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
9.
Circ Cardiovasc Interv ; 14(2): e009529, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33591821

RESUMEN

BACKGROUND: The index of microcirculatory resistance (IMR) of the infarct-related artery and left ventricular end-diastolic pressure (LVEDP) are acute, prognostic biomarkers in patients undergoing primary percutaneous coronary intervention. The clinical significance of IMR and LVEDP in combination is unknown. METHODS: IMR and LVEDP were prospectively measured in a prespecified substudy of the T-TIME clinical trial (Trial of Low Dose Adjunctive Alteplase During Primary PCI). IMR was measured using a pressure- and temperature-sensing guidewire following percutaneous coronary intervention. Prognostically established thresholds for IMR (>32) and LVEDP (>18 mm Hg) were predefined. Contrast-enhanced cardiovascular magnetic resonance imaging (1.5 Tesla) was acquired 2 to 7 days and 3 months postmyocardial infarction. The primary end point was major adverse cardiac events, defined as cardiac death/nonfatal myocardial infarction/heart failure hospitalization at 1 year. RESULTS: IMR and LVEDP were both measured in 131 patients (mean age 59±10.7 years, 103 [78.6%] male, 48 [36.6%] with anterior myocardial infarction). The median IMR was 29 (interquartile range, 17-55), the median LVEDP was 17 mm Hg (interquartile range, 12-21), and the correlation between them was not statistically significant (r=0.15; P=0.087). Fifty-three patients (40%) had low IMR (≤32) and low LVEDP (≤18), 18 (14%) had low IMR and high LVEDP, 31 (24%) had high IMR and low LVEDP, while 29 (22%) had high IMR and high LVEDP. Infarct size (% LV mass), LV ejection fraction, final myocardial perfusion grade ≤1, TIMI (Thrombolysis In Myocardial Infarction) flow grade ≤2, and coronary flow reserve were associated with LVEDP/IMR group, as was hospitalization for heart failure (n=18 events; P=0.045) and major adverse cardiac events (n=21 events; P=0.051). LVEDP>18 and IMR>32 combined was associated with major adverse cardiac events, independent of age, estimated glomerular filtration rate, and infarct-related artery (odds ratio, 5.80 [95% CI, 1.60-21.22] P=0.008). The net reclassification improvement for detecting major adverse cardiac events was 50.6% (95% CI, 2.7-98.2; P=0.033) when LVEDP>18 was added to IMR>32. CONCLUSIONS: IMR and LVEDP in combination have incremental value for risk stratification following primary percutaneous coronary intervention. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02257294.


Asunto(s)
Infarto del Miocardio , Anciano , Presión Sanguínea , Femenino , Humanos , Masculino , Microcirculación , Persona de Mediana Edad , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Medición de Riesgo , Resultado del Tratamiento , Función Ventricular Izquierda
10.
J Cardiovasc Med (Hagerstown) ; 22(2): 126-132, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-32941330

RESUMEN

AIMS: We compared strategies in the treatment of decompensated severe aortic stenosis. The hypothesis was that undertaking urgent or emergency transcatheter aortic valve implantation (TAVI) directly in such patients is safer and more effective than urgent or emergency balloon aortic valvuloplasty (BAV) followed by elective TAVI or surgical aortic valve replacement (SAVR). METHODS: This was a single-centre retrospective study including all consecutive patients who underwent urgent or emergency BAV or TAVI for decompensated severe aortic stenosis between September 2014 and February 2018. Primary endpoints were 30-day and 1-year mortality. RESULTS: Fifty-two patients underwent urgent or emergency BAV and 87 underwent TAVI. Baseline characteristics of the two groups were well matched. Significant differences were noted between the two groups in 30-day all-cause mortality (88.5% BAV patients alive at 30 days, 97.7% TAVI patients; P < 0.05) and 1-year all-cause mortality (44.2% BAV patients alive at 1 year, 88.5% TAVI patients; P < 0.001). At 1 year, the estimated hazard ratio for patients undergoing BAV was 11.2 (95% confidence interval: 4.67-26.9; P < 0.001) when adjusted for potential confounding variables. Patients in the BAV group who successfully underwent subsequent TAVI or SAVR all survived for 365 days, but there was no significant 1-year mortality difference compared with those who underwent urgent or emergency TAVI (100 vs. 88.5%; P > 0.155). CONCLUSION: Our results suggest treatment of decompensated severe aortic stenosis with urgent or emergency TAVI may be associated with improved survival outcomes when compared with a strategy of performing BAV as a bridge to subsequent TAVI or SAVR.


Asunto(s)
Atención Ambulatoria/normas , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Urgencias Médicas , Tratamiento de Urgencia/normas , Guías de Práctica Clínica como Asunto , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Femenino , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Tomografía Computarizada por Rayos X
11.
Circ Cardiovasc Interv ; 13(2): e008855, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-32069113
12.
JACC Case Rep ; 2(3): 347-351, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34291227

RESUMEN

We describe a patient who presented with heart failure 7 years post-transcatheter aortic valve implantation (TAVI) as a result of severe structural valve degeneration. Anatomic challenges, combined with the type of transcatheter heart valve used initially, meant that TAVI-in-TAVI risked obstructing the coronary arteries, even if preceded by bioprosthetic aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction. The patient was treated with balloon aortic valvuloplasty.

13.
Catheter Cardiovasc Interv ; 95(7): 1340-1346, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-31713325

RESUMEN

OBJECTIVES: The United Kingdom and Ireland Implanters' registry is a multicenter registry which reports on real-world experience with new transcatheter heart valves. BACKGROUND: The Evolut PRO (Medtronic, Minneapolis, MN) transcatheter aortic valve is a self-expanding transcatheter aortic valve with an outer pericardial wrap, designed to minimize paravalvular regurgitation. METHODS: Between July 2017 and December 2018, clinical, procedural, and 30-day outcome data were prospectively collected from all patients receiving the Evolut PRO valve across nine participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2 (VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 317 patients underwent implantation. Mean age was 81.8 ± 6.4 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.5 ± 1.8%. Iliofemoral access was used in 99.1% of patients. Device success was 91.2%. Mean gradient was 7.6 ± 4.7 mmHg and effective orifice area 1.9 ± 0.7 cm2 . The incidence of moderate paravalvular regurgitation was 1.7% and there was no severe paravalvular regurgitation. A new permanent pacemaker was implanted in 17.8% of patients without a pacemaker at baseline. Early safety was demonstrated in 92.7%. At 30 days, all-cause mortality was 0.6%, stroke 3.8%, and major vascular complication 2.8%. CONCLUSIONS: Real-world experience of the Evolut PRO transcatheter aortic valve demonstrated favorable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Pericardio/trasplante , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Humanos , Irlanda , Masculino , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Reino Unido
14.
JACC Heart Fail ; 7(11): 945-955, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31521683

RESUMEN

OBJECTIVES: This study sought to evaluate the effects of the Carillon device on mitral regurgitation severity and left ventricular remodeling. BACKGROUND: Functional mitral regurgitation (FMR) complicates heart failure with reduced ejection fraction and is associated with a poor prognosis. METHODS: In this blinded, randomized, proof-of-concept, sham-controlled trial, 120 patients receiving optimal heart failure medical therapy were assigned to a coronary sinus-based mitral annular reduction approach for FMR or sham. The pre-specified primary endpoint was change in mitral regurgitant volume at 12 months, measured by quantitative echocardiography according to an intention-to-treat analysis. RESULTS: Patients (69.8 ± 9.5 years of age) were randomized to either the treatment (n = 87) or the sham-controlled (n = 33) arm. There were no significant differences in baseline characteristics between the groups. In the treatment group, 73 of 87 (84%) had the device implanted. The primary endpoint was met, with a statistically significant reduction in mitral regurgitant volume in the treatment group compared to the control group (decrease of 7.1 ml/beat [95% confidence interval [CI]: -11.7 to -2.5] vs. an increase of 3.3 ml/beat [95% CI: -6.0 to 12.6], respectively; p = 0.049). Additionally, there was a significant reduction in left ventricular volumes in patients receiving the device versus those in the control group (left ventricular end-diastolic volume decrease of 10.4 ml [95% CI: -18.5 to -2.4] vs. an increase of 6.5 ml [95% CI: -5.1 to 18.2]; p = 0.03 and left ventricular end-systolic volume decrease of 6.2 ml [95% CI: -12.8 to 0.4] vs. an increase of 6.1 ml [95% CI: -1.42 to 13.6]; p = 0.04). CONCLUSIONS: The Carillon device significantly reduced mitral regurgitant volume and left ventricular volumes in symptomatic patients with functional mitral regurgitation receiving optimal medical therapy. (Carillon Mitral Contour System for Reducing Functional Mitral Regurgitation [REDUCE FMR]; NCT02325830).


Asunto(s)
Anuloplastia de la Válvula Mitral/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Anciano , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Anuloplastia de la Válvula Mitral/métodos , Prueba de Estudio Conceptual , Índice de Severidad de la Enfermedad , Remodelación Ventricular
15.
Clin Med (Lond) ; 19(5): 364-368, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31530682

RESUMEN

Use of angiography for the assessment of coronary lesions is limited by its inability to provide information regarding the functional significance of stenoses. A number of studies have demonstrated the presence of ischaemia to be the most important determinant of the benefit associated with coronary revascularisation in stable coronary artery disease. Assessment of intra-coronary physiology can guide percutaneous coronary intervention, and is often used for angiographically borderline stenoses. There is now increasing evidence to suggest that more routine use can improve clinical outcomes. Fractional flow reserve (FFR) is the most established measure of intra-coronary physiology, but is currently under-utilised. The main drawback of FFR is the dependence on a pharmacological infusion to maintain hyperaemia. An alternative technique which measures flow at a specific point in the cardiac cycle (instantaneous wave-free ratio) has been developed which obviates the need for hyperaemia and may replace FFR as the default measure.


Asunto(s)
Enfermedad de la Arteria Coronaria , Vasos Coronarios , Técnicas de Diagnóstico Cardiovascular , Reserva del Flujo Fraccional Miocárdico/fisiología , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiología , Vasos Coronarios/fisiopatología , Medicina Basada en la Evidencia , Humanos , Modelos Cardiovasculares , Intervención Coronaria Percutánea
16.
Open Heart ; 6(1): e000951, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31328001

RESUMEN

Background: There is a paucity of real-world outcome data comparing clopidogrel, prasugrel and ticagrelor in primary percutaneous coronary intervention (PPCI) for ST-segment elevation myocardial infarction (STEMI). We sought to assess the association of choice of oral P2Y12-receptor inhibitor with clinical outcomes following PPCI for STEMI in a large consecutive patient series. Methods: Demographic, procedural and 12-month outcome data were prospectively collected for all patients undergoing PPCI in Leeds, UK, between 01 January 2009 and 31 December 2011, and 01 January 2013 and 31 December 2013. Clinical endpoints were 30-day and 12-month all-cause mortality, recurrent MI and 30-day HORIZONS-major bleeding. Logistic regression analyses were undertaken to adjust for confounding factors. Results: Prasugrel (n=1244) was associated with lower adjusted 30-day (OR 0.53 (0.34-0.85)) and 12-month (OR 0.55 (0.38-0.78)) mortality, and 12-month MI (OR 0.63 (0.42-0.94)) compared with clopidogrel (n=1648). Importantly, prasugrel was associated with lower adjusted 30-day mortality (OR 0.51 (0.29-0.91)) compared with ticagrelor (n=811). Lower 30-day (OR 0.40 (0.17-0.94)) and 12-month (OR 0.54 (0.32-0.93)) MI were observed in ticagrelor compared with clopidogrel, an association absent in comparison with prasugrel. Adjusted bleeding were not statistically significantly different among the P2Y12-receptor inhibitors. Conclusion: In this large consecutive real-world series, prasugrel was associated with lower adjusted 30-day mortality compared with ticagrelor and clopidogrel, and lower adjusted 12-month mortality compared with clopidogrel. Both prasugrel and ticagrelor were associated with lower recurrent MI following PPCI compared with clopidogrel, with no overall increase in adjusted bleeding.

17.
J Cardiol Cases ; 19(3): 81-84, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30949246

RESUMEN

Access site vascular complications remain relatively frequent following trans-femoral (TF) transcatheter aortic valve implantation (TAVI), and are associated with significant morbidity as well as increased mortality. Suture-based vascular closure devices (VCD) are widely used and have been demonstrated to reduce the rate of vascular complications. However, failure to achieve adequate hemostasis following their use occurs in some cases, and may necessitate surgical escalation. We report a case of a patient with complex ileo-femoral anatomy in whom the novel plug-based MANTA VCD was successfully used to achieve hemostasis post-TF TAVI following failed closure with ProGlides®. A 79-year-old male underwent valve-in-valve TF TAVI for the treatment of severe degenerative disease of a Mitroflow prosthesis. Pre-procedural imaging demonstrated tortuous and calcific ileo-femoral arteries and torrential bleeding occurred following sheath removal and deployment of the pre-sited ProGlides®. Consideration was given to surgical intervention but the decision was taken to attempt rescue closure using a 14F MANTA VCD. Hemostasis was successfully achieved and the patient recovered well. Early data assessing the efficacy of the MANTA VCD have been promising and this relatively novel technology appears to be a viable alternative to established VCDs. .

18.
J Am Coll Cardiol ; 73(5): 537-545, 2019 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-30732706

RESUMEN

BACKGROUND: Very little is known about long-term valve durability after transcatheter aortic valve replacement (TAVR). OBJECTIVES: This study sought to evaluate the incidence of structural valve degeneration (SVD) 5 to 10 years post-procedure. METHODS: Demographic, procedural, and in-hospital outcome data on patients who underwent TAVR from 2007 to 2011 were obtained from the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) registry. Patients in whom echocardiographic data were available both at baseline and ≥5 years post-TAVR were included. Hemodynamic SVD was determined according to European task force committee guidelines. RESULTS: A total of 241 patients (79.3 ± 7.5 years of age; 46% female) with paired post-procedure and late echocardiographic follow-up (median 5.8 years, range 5 to 10 years) were included. A total of 149 patients (64%) were treated with a self-expandable valve and 80 (34.7%) with a balloon-expandable valve. Peak aortic valve gradient at follow-up was lower than post-procedure (17.1 vs. 19.1 mm Hg; p = 0.002). More patients had none/trivial aortic regurgitation (AR) (47.5% vs. 33%), and fewer had mild AR (42.5% vs. 57%) at follow-up (p = 0.02). There was 1 case (0.4%) of severe SVD 5.3 years after implantation (new severe AR). There were 21 cases (8.7%) of moderate SVD (mean 6.1 years post-implantation; range 4.9 to 8.6 years). Twelve of these (57%) were due to new AR and 9 (43%) to restenosis. CONCLUSIONS: Long-term transcatheter aortic valve function is excellent. In the authors' study, 91% of patients remained free of SVD between 5 and 10 years post-implantation. The incidence of severe SVD was <1%. Moderate SVD occurred in 1 in 12 patients.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/epidemiología , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía/métodos , Femenino , Hemodinámica , Humanos , Efectos Adversos a Largo Plazo/diagnóstico , Efectos Adversos a Largo Plazo/epidemiología , Masculino , Evaluación de Procesos y Resultados en Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reino Unido/epidemiología
19.
BMJ Open ; 9(1): e022329, 2019 01 21.
Artículo en Inglés | MEDLINE | ID: mdl-30670503

RESUMEN

OBJECTIVE: To compare the incidence of silent cerebral infarction and impact on cognitive function following transcatheter aortic valve implantation (TAVI) with the first-generation CoreValve (Medtronic, Minneapolis, Minnesota, USA) and second-generation Lotus valve (Boston Scientific, Natick Massachusetts, USA). DESIGN: A prospective observational study comprising a 1.5 T cerebral MRI scan, performed preoperatively and immediately following TAVI, and neurocognitive assessments performed at baseline, 30 days and 1 year follow-up. SETTING: University hospitals of Leeds and Leicester, UK. PATIENTS: 66 (80.6±8.0 years, 47% male) patients with high-risk severe symptomatic aortic stenosis recruited between April 2012 and May 2015. MAIN OUTCOME MEASURES: Incidence of new cerebral microinfarction and objective decline in neurocognitive performance. RESULTS: All underwent cerebral MRI at baseline and immediately following TAVI, and 49 (25 Lotus, 24 CoreValve) completed neurocognitive assessments at baseline, 30 days and 1 year. There was a significantly greater incidence of new cerebral microinfarction observed following the Lotus TAVI (23 (79%) vs 22 (59%), p=0.025) with a greater number of new infarcts per patient (median 3.5 (IQR 7.0) vs 2.0 (IQR 3.0), p=0.002). The mean volume of infarcted cerebral tissue per patient was equivalent following the two prostheses (p=0.166). More patients suffered new anterior (14 (48%) vs 2 (5%), p=0.001) and vertebrobasilar (15 (52%) vs 7 (19%), p=0.005) lesions following Lotus. Lotus was associated with a decline in verbal memory and psychomotor speed at 30 days. However, performance longitudinally at 1 year was preserved in all neurocognitive domains. CONCLUSIONS: There was a higher incidence of silent cerebral microinfarction and a greater number of lesions per patient following Lotus compared with CoreValve. However, there was no objective decline in neurocognitive function discernible at 1 year following TAVI with either prosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Infarto Cerebral/fisiopatología , Cognición , Prótesis Valvulares Cardíacas/clasificación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Infarto Cerebral/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Femenino , Humanos , Masculino , Pruebas de Estado Mental y Demencia , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Reino Unido
20.
JAMA ; 321(1): 56-68, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30620371

RESUMEN

Importance: Microvascular obstruction commonly affects patients with acute ST-segment elevation myocardial infarction (STEMI) and is associated with adverse outcomes. Objective: To determine whether a therapeutic strategy involving low-dose intracoronary fibrinolytic therapy with alteplase infused early after coronary reperfusion will reduce microvascular obstruction. Design, Setting, and Participants: Between March 17, 2016, and December 21, 2017, 440 patients presenting at 11 hospitals in the United Kingdom within 6 hours of STEMI due to a proximal-mid-vessel occlusion of a major coronary artery were randomized in a 1:1:1 dose-ranging trial design. Patient follow-up to 3 months was completed on April 12, 2018. Interventions: Participants were randomly assigned to treatment with placebo (n = 151), alteplase 10 mg (n = 144), or alteplase 20 mg (n = 145) by manual infusion over 5 to 10 minutes. The intervention was scheduled to occur early during the primary PCI procedure, after reperfusion of the infarct-related coronary artery and before stent implant. Main Outcomes and Measures: The primary outcome was the amount of microvascular obstruction (% left ventricular mass) demonstrated by contrast-enhanced cardiac magnetic resonance imaging (MRI) conducted from days 2 through 7 after enrollment. The primary comparison was the alteplase 20-mg group vs the placebo group; if not significant, the alteplase 10-mg group vs the placebo group was considered a secondary analysis. Results: Recruitment stopped on December 21, 2017, because conditional power for the primary outcome based on a prespecified analysis of the first 267 randomized participants was less than 30% in both treatment groups (futility criterion). Among the 440 patients randomized (mean age, 60.5 years; 15% women), the primary end point was achieved in 396 patients (90%), 17 (3.9%) withdrew, and all others were followed up to 3 months. In the primary analysis, the mean microvascular obstruction did not differ between the 20-mg alteplase and placebo groups (3.5% vs 2.3%; estimated difference, 1.16%; 95% CI, -0.08% to 2.41%; P = .32) nor in the analysis of 10-mg alteplase vs placebo groups (2.6% vs 2.3%; estimated difference, 0.29%; 95% CI, -0.76% to 1.35%; P = .74). Major adverse cardiac events (cardiac death, nonfatal MI, unplanned hospitalization for heart failure) occurred in 15 patients (10.1%) in the placebo group, 18 (12.9%) in the 10-mg alteplase group, and 12 (8.2%) in the 20-mg alteplase group. Conclusions and Relevance: Among patients with acute STEMI presenting within 6 hours of symptoms, adjunctive low-dose intracoronary alteplase given during the primary percutaneous intervention did not reduce microvascular obstruction. The study findings do not support this treatment. Trial Registration: ClinicalTrials.gov Identifier: NCT02257294.


Asunto(s)
Oclusión Coronaria/tratamiento farmacológico , Infarto del Miocardio con Elevación del ST/tratamiento farmacológico , Activador de Tejido Plasminógeno/administración & dosificación , Anciano , Área Bajo la Curva , Catéteres Cardíacos , Terapia Combinada , Angiografía Coronaria , Oclusión Coronaria/cirugía , Vasos Coronarios , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Infusiones Intraarteriales , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea , Calidad de Vida , Infarto del Miocardio con Elevación del ST/cirugía , Activador de Tejido Plasminógeno/efectos adversos , Insuficiencia del Tratamiento , Troponina T/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...