Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Exp Immunol ; 210(2): 91-103, 2022 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-36208448

RESUMEN

A prospective study and its long-term extension examined whether weekly treatment of patients with primary immunodeficiencies (PIDs) with a 16.5% subcutaneous immunoglobulin (SCIg; cutaquig®) confers acceptable efficacy, safety, and tolerability over a follow-up of up to 238 weeks (>4 years). Seventy-five patients received 4462 infusions during up to 70 weeks of follow-up in the main study and 27 patients received 2777 infusions during up to 168 weeks of follow-up in the extension. In the main study, there were no serious bacterial infections (SBIs), and the annual rate of other infections was 3.3 (95% CI 2.4, 4.5). One SBI was recorded in the extension, for an SBI rate of 0.02 (upper 99% CI 0.19). The annual rate of all infections over the duration of the extension study was 2.2 (95% CI 1.2, 3.9). Only 15.0% (1085) of 7239 infusions were associated with infusion site reactions (ISRs), leaving 85.0% (6153) of infusions without reactions. The majority of ISRs were mild and transient. ISR incidence decreased over time, from 36.9% to 16% during the main study and from 9% to 2.3% during the extension. The incidence of related systemic adverse events was 14.7% in the main study and 7.4% in the extension. In conclusion, this prospective, long-term study with cutaquig showed maintained efficacy and low rates of local and systemic adverse reactions in PID patients over up to 238 weeks of follow-up.


Asunto(s)
Infecciones Bacterianas , Síndromes de Inmunodeficiencia , Humanos , Estudios Prospectivos , Infusiones Subcutáneas , Síndromes de Inmunodeficiencia/tratamiento farmacológico , Inmunoglobulina G/uso terapéutico , Resultado del Tratamiento , Inmunoglobulinas Intravenosas/uso terapéutico
3.
Front Immunol ; 12: 707463, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34305948

RESUMEN

We report here the results of a phase 3 study to assess the efficacy, safety, and tolerability of GC5107, a new 10% liquid intravenous immunoglobulin (IVIG) in preventing serious bacterial infections in patients with primary immunodeficiency (ClinicalTrials.gov: NCT02783482). Over a 12-month study period, 49 patients aged 3 to 70 years with a confirmed diagnosis of primary immunodeficiency received GC5107 at doses ranging from 319 to 881 mg/kg body weight every 21 or 28 days, according to their previous IVIG maintenance therapy. A total of 667 infusions of GC5107 were administered comprising a total of 45.86 patient-years of treatment. A single acute serious bacterial infection occurred during the study, resulting in an incidence of 0.02 events per patient-year (upper 99% one-sided confidence interval limit: 0.21), meeting the prespecified primary efficacy endpoint. The mean incidence of infections other than acute serious bacterial infections was 2.9 infections per patient-year. Efficacy was also demonstrated by the low mean annualized rate of hospitalizations due to infection (0.1 day) and the mean annualized duration of hospitalizations (0.1 day). The mean rate of intravenous and oral antibiotic use was 0.1 day and 13.2 days, respectively. There was a mean of 7.1 days of missed work, school, or daycare days. The proportion of infusions with temporally associated adverse events (TAAEs) occurring during or within 72 hours after GC5107 infusion was 0.24 (upper 95% one-sided confidence interval limit: 0.31), meeting the pre-specified primary safety endpoint. Overall, 149 of 667 infusions (22%) were associated with TAAEs. The most common TAAE was headache, reported by 49% of patients. More than 98% (731/743) of all adverse events that occurred throughout the 12-month study period were mild or moderate. More than 98% of infusions were completed without discontinuation, interruption or rate reduction. There were no treatment-emergent serious adverse events related to GC5107 or study discontinuations due to an adverse event. Overall, pharmacokinetic parameters for GC5107 were within the range of those reported in studies of other marketed IVIG products. Results of the present study demonstrate that GC5107 is an effective, safe and well-tolerated treatment for patients with primary immunodeficiency.


Asunto(s)
Inmunoglobulina G/uso terapéutico , Enfermedades de Inmunodeficiencia Primaria/tratamiento farmacológico , Adolescente , Adulto , Anciano , Infecciones Bacterianas/prevención & control , Niño , Preescolar , Femenino , Humanos , Infusiones Subcutáneas , Masculino , Persona de Mediana Edad , Adulto Joven
4.
Front Immunol ; 10: 40, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30778345

RESUMEN

Introduction: Subcutaneously administered immunoglobulin (SCIG) is increasingly used to treat patients with primary immunodeficiencies (PIDs). Octanorm (marketed as cutaquig® in USA and Canada) is a new 16.5% solution of human SCIG, manufactured by a process based on that of the intravenous preparation (IVIG) octagam®. Objectives: To investigate the efficacy, safety and tolerability of octanorm in a prospective, open-label, single-arm phase 3 study involving adult and pediatric patients with PIDs (NCT01888484; clinicaltrials.gov/ct2/show/NCT01888484). Methods: Patients who were previously treated with IVIG received a total of 64 weekly SCIG infusions, including 12 weekly infusions during the wash-in/wash-out period, followed by 52 weekly infusions during the evaluation period. Results: A total of 61 patients aged 2-73 years received 3,497 infusions of octanorm. The mean dose per patient was 0.175 g/kg/infusion. The mean calculated dose conversion factor from the patients' previous IVIG dose for octanorm was 1.37. No serious bacterial infections developed during the study. The rate of other infections per person-year during the primary observation period was 3.43 (upper 95% CI 4.57). All but one non-bacterial infection were mild or moderate in intensity. IgG trough levels were constant during the course of the study. Eleven patients (18.0%) experienced 14 mild or moderate systemic adverse events (AEs) related to octanorm. The rate of related AEs per infusion was 0.004. In 76.7% of infusions, no infusion site reactions were observed and only two (0.3%) reactions were deemed severe. The incidence of site reactions decreased with successive infusions. Conclusion: The new 16.5% SCIG octanorm was shown to be efficacious in preventing infections in PIDs, and was well tolerated.


Asunto(s)
Inmunización Pasiva , Síndromes de Inmunodeficiencia/tratamiento farmacológico , Adolescente , Adulto , Anciano , Niño , Preescolar , Femenino , Humanos , Inmunización Pasiva/métodos , Inmunoglobulina G/administración & dosificación , Inmunoglobulina G/sangre , Inmunoglobulinas Intravenosas/administración & dosificación , Inmunoglobulinas Intravenosas/farmacocinética , Inmunoglobulinas Intravenosas/uso terapéutico , Infusiones Subcutáneas , Masculino , Persona de Mediana Edad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...