Expert Rev Med Devices ; 17(7): 637-648, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32500762

RESUMEN

INTRODUCTION: Heart failure (HF) leads to significant morbidity and mortality and imposes a large economic burden. Although there have been several advances in HF monitoring and management, HF-rehospitalization remains a significant problem. Remote monitoring of HF to detect early signs of decompensation has emerged in past years as an option to prevent or reduce the incidence of HF rehospitalization. The CardioMEMSTM HF system is a wireless pulmonary artery (PA) pressure monitoring system that detects changes in PA pressure and transmits data to the healthcare provider. Since changes in PA pressure happen early in the course of HF decompensation, the CardioMEMSTM system allows the provider to institute timely intensification of HF therapies to alter the course. In trial and registry data, the use of the CardioMEMSTM HF system has been associated with reduction in HF hospitalization, improvement in quality of life, symptoms, and physical activity. AREAS COVERED: This review will focus on the available data supporting its utilization in patients with HF. EXPERT OPINION: CardioMEMSTM is relatively safe and cost-effective, reduces heart failure hospitalization rates, and fits into intermediate to high-value medical care.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial/efectos adversos , Insuficiencia Cardíaca/terapia , Sistemas Microelectromecánicos/instrumentación , Monitoreo Ambulatorio de la Presión Arterial/economía , Análisis Costo-Beneficio , Insuficiencia Cardíaca/economía , Implantación de Prótesis de Válvulas Cardíacas/economía , Humanos , Arteria Pulmonar/cirugía
3.
J Invasive Cardiol ; 32(5): 194-200, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32357131

RESUMEN

OBJECTIVES: Endovascular therapy (EVT) has emerged as an alternative to surgery for the treatment of symptomatic infrarenal aortic stenosis (IAS). However, long-term outcomes with EVT are unknown. METHODS: We performed a retrospective review of patients with IAS treated with the endovascular approach at the University of Toledo Medical Center, Toledo, Ohio. We compared our single-center study (SCS) with a review of published studies (ROS) regarding complications, patency rate (PR), and repeat intervention rate (RIR). Pearson's Chi-square or Fisher's exact test, and the Student's t-test or Mann-Whitney U-test, were used for categorical and continuous variables, respectively. For the ROS data, we used a pooled mean of means. RESULTS: A total of 25 patients from the SCS were compared with 698 patients from the ROS data. Mean age was 63 years vs 58 years, females comprised 48% vs 54%, Rutherford class 3 comprised 68% vs 69%, and mean follow-up duration was 67 months vs 44 months in SCS vs ROS, respectively. PR at 12 months was 96% vs 90%, while PR at maximum time-period was 92% vs 76% in SCS vs ROS, respectively. RIR in SCS was 4% at 12 months and 8% at the maximum time period (20.2 years). RIR in ROS was 24% at the maximum time period (10 years). The mortality rate was 0% in the SCS arm vs 3.4% in the ROS arm. CONCLUSION: EVT is highly effective and safe, and was associated with excellent patency rates at long-term follow-up.


Asunto(s)
Enfermedades de la Aorta , Procedimientos Endovasculares , Implantación de Prótesis Vascular , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ohio/epidemiología , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
4.
J Interv Cardiol ; 2019: 1593401, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31772513

RESUMEN

INTRODUCTION: Common femoral endarterectomy (CFE) has been the therapy of choice for common femoral artery atherosclerotic disease (CFA-ASD). In the past, there was inhibition to treat CFA-ASD endovascularly with stents due to fear of stent fracture and compromise of future vascular access site. However, recent advances and new evidence suggest that CFA may no longer be a 'stent-forbidden zone'. In the light of new evidence, we conducted a meta-analysis to determine the use of endovascular treatment for CFA-ASD and compare it with common femoral endarterectomy in the present era. METHODS: Using certain MeSH terms we searched multiple databases for studies done on endovascular and surgical treatment of CFA-ASD in the last two decades. Inclusion criteria were randomized control trials, observational, prospective, or retrospective studies evaluating an endovascular treatment or CFE for CFA-ASD. For comparison, studies were grouped based on the treatment strategy used for CFA-ASD: endovascular treatment with selective stenting (EVT-SS), endovascular treatment with routine stenting (EVT-RS), or common femoral endarterectomy (CFE). Primary patency (PP), target lesion revascularization (TLR), and complications were the outcomes studied. We did proportional meta-analysis using a random-effect model due to heterogeneity among the included studies. If confidence intervals of two results do not overlap, then statistical significance is determined. RESULTS: Twenty-eight studies met inclusion criteria (7 for EVT-RS, 8 for EVT-SS, and 13 for CFE). Total limbs involved were 2914 (306 in EVT-RS, 678 in EVT-SS, and 1930 in CFE). The pooled PP at 1 year was 84% (95% CI 75-92%) for EVT-RS, 78% (95% CI 69-85%) for EVT-SS, and 93% (95% CI 90-96%) for CFE. PP at maximum follow-up in EVT-RS was 83.7% (95% CI 74-91%) and in CFE group was 88.3% (95% CI 81-94%). The pooled target lesion revascularization (TLR) rate at one year was 8% (95% CI 4-13%) for EVT-RS, 19% (95% CI 14-23%) for EVT-SS, and 4.5% (95% CI 1-9%) for CFE. The pooled rate of local complications for EVT-RS was 5% (95% CI 2-10%), for EVT-SS was 7% (95% CI 3 to 12%), and CFE was 22% (95% CI 14-32%). Mortality at maximum follow-up in CFE group was 23.1% (95% CI 14-33%) and EVT-RS was 5.3% (95% CI 1-11%). CONCLUSION: EVT-RS has comparable one-year PP and TLR as CFE. CFE showed an advantage over EVT-SS for one-year PP. The complication rate is lower in EVT RS and EVT SS compared to CFE. At maximum follow-up, CFE and EVT-RS have similar PP but CFE has a higher mortality. These findings support EVT-RS as a management alternative for CFA-ASD.


Asunto(s)
Aterosclerosis/cirugía , Endarterectomía , Procedimientos Endovasculares , Arteria Femoral/cirugía , Humanos , Stents , Grado de Desobstrucción Vascular
6.
Cureus ; 10(7): e2931, 2018 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-30310762

RESUMEN

The United States (US) is the third most expensive health care system in the world, but despite that, the US ranked last in the top 50 countries of the world when it comes to the performance measures, such as healthcare efficiency, life expectancy, health care costs, and gross domestic product (GDP) percentage. The spending health care cost keeps increasing and most of the healthcare costs go to waste. Due to this reason, it is therefore extremely important to focus on improving the quality and to bring the costs in appropriate control. To avoid this issue, the Choosing Wisely Campaign (CWC) came into being in 2012. The CWC encourages discussions between providers and patients regarding the care based on the evidence base, free from harm, duplicative or redundant tests/procedures that the patient already received, and whether medications, tests, or procedures are really necessary. Although diagnostic tests or procedures are highly valued for decision-making, unnecessary testing creates harmful health services and an economic impact on the healthcare system. The CWC has spread widely throughout the world but has many challenges which are limiting the CWC in further adoption and spread in the US. To overcome challenges in implementing and spreading the CWC, the government, physicians, social media, and mass media play an important role.

7.
World J Cardiol ; 9(9): 715-722, 2017 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-29081903

RESUMEN

Use of X-ray contrast allows us to differentiate between two or more adjacent structures on radiographic studies. The X-ray contrast agent can be the one with increase X-ray absorption, like iodine and a barium X-ray contrast agent or the one with decrease X-ray absorption like air and carbon dioxide contrast agent. Each contrast agent possesses different risks and benefits in various ways. Carbon dioxide as an intravascular contrast agent can be used as an alternative intravascular contrast agent and has superior results in some cases. In patients with renal dysfunction or iodinated contrast allergy, the use of Iodinated Contrast Agent poses the risk of considerable morbidity. Similarly, use of Gadolinium is discouraged in subject with severe renal dysfunction. Use of carbon dioxide (CO2) as an intravascular contrast, offers an alternative in such patients for certain procedures, as it is not nephrotoxic and it does not incite allergic reactions. It is inexpensive, readily available and due to its unique physical properties, it can be used to image a wide variety of vascular beds and chambers. The aim of this paper is to systemically review the current literature to describe the indications, contraindications, adverse effects, instruments, precautions, latest methodologies and data supporting for the use of CO2 as a contrast agent.