Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 243
Filtrar
2.
JACC Cardiovasc Interv ; 17(6): 742-752, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38538170

RESUMEN

BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Oclusión Coronaria , Prótesis Valvulares Cardíacas , Laceraciones , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Laceraciones/complicaciones , Laceraciones/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Oclusión Coronaria/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Diseño de Prótesis
3.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38506737

RESUMEN

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Bioprótesis , Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Catéteres , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Válvulas Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
4.
JACC Cardiovasc Interv ; 17(5): 666-677, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38479966

RESUMEN

BACKGROUND: Acute ischemic stroke remains a serious complication of transcatheter aortic valve replacement (TAVR). Cerebral embolic protection devices (CEPD) were developed to mitigate the risk of acute ischemic stroke complicating TAVR (AISCT). However, the existing body of evidence does not clearly support CEPD efficacy in AISCT prevention. OBJECTIVES: In a cohort of patients with AISCT, we aimed to compare the characteristics and outcomes of patients who have had unprotected TAVR (CEPD-) vs CEPD-protected TAVR (CEPD+). METHODS: Data were derived from an international multicenter registry focusing on AISCT. We included all patients who experienced ischemic stroke within 72 hours of TAVR. Stroke severity was assessed using the National Institutes of Health Stroke Scale (NIHSS). Primary outcomes were neurologic disability status according to the modified Rankin Score at 30 days, and 6-month all-cause death. Propensity score matched analysis was used to control for differences between groups. RESULTS: In 18,725 TAVR procedures, 416 AISCT (2.2%) within 72 hours were documented, of which 376 were in the CEPD- TAVR group and 40 in the CEPD+ TAVR group. Although the middle cerebral artery stroke rate was similar in both groups (29.7% CEPD- vs 33.3% CEPD+; P = 0.71), AISCT in the CEPD+ group was characterized by a lower rate of internal carotid artery occlusion (0% vs 4.7%) and higher rate of vertebrobasilar system strokes (15.4% vs 5.7%; P = 0.04). AISCT was severe (NIHSS ≥15) in 21.6% CEPD- and 23.3% CEPD+ AISCT (P = 0.20). Disabling stroke rates (modified Rankin Score >1 at 30 days) were 47.3% vs 42.5% (P = 0.62), and 6-month mortality was 31.3% vs 23.3% (P = 0.61), in the CEPD- and CEPD+ groups, respectively. In the propensity score matched cohort, disabling stroke rates were 56.5% vs 41.6% (P = 0.16), and 6-month mortality was 33% vs 19.5% (P = 0.35), in the CEPD- and CEPD+ groups, respectively. CONCLUSIONS: In a large cohort of patients with AISCT, the use of CEPD had little effect on stroke distribution, severity, and outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Accidente Cerebrovascular Isquémico/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
6.
7.
Cardiovasc Diabetol ; 23(1): 52, 2024 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-38310281

RESUMEN

BACKGROUND: The outcomes of percutaneous coronary intervention (PCI) in diabetic patients are still suboptimal, and it is unclear if diabetic patients might derive a benefit from the use of drug-coated balloons. AIMS: To evaluate the impact of diabetes mellitus on the outcomes of patients undergoing PCI with sirolimus-coated balloon (SCB) MagicTouch (Concept Medical, India). METHODS: We conducted a subgroup analysis of the prospective, multicenter, investigator-initiated EASTBOURNE registry, evaluating the performance of MagicTouch SCB in patients with and without diabetes. The study primary endpoint was target lesion revascularization (TLR) at 12-month follow-up. Secondary clinical endpoints were major adverse clinical events (MACE), death, myocardial infarction (MI), and BARC 2-5 bleedings. RESULTS: Among 2,083 enrolled patients, a total of 864 suffered from diabetes (41.5%). Patients with diabetes had a numerically higher occurrence of TLR (6.5% vs. 4.7% HR 1.38, 95%CI 0.91-2.08), all-cause death (3.8% vs. 2.6%, HR 1.81, 95%CI 0.95-3.46), and MACE (12.2% vs. 8.9%; HR 1.26 95%CI 0.92-1.74). The incidence of spontaneous MI was significantly higher among diabetic patients (3.4% vs. 1.5%, HR 2.15 95%CI 1.09-4.25); bleeding events did not significantly differ. The overall incidence of TLR was higher among in-stent restenosis (ISR) as compared to de-novo coronary lesions, irrespectively from diabetes status. CONCLUSIONS: In the EASTBOURNE DIABETES registry, diabetic patients treated with the MagicTouch SCB did not have a significant increase in TLR when compared to non-diabetic patients; moreover, diabetic status did not affect the study device performance in terms of TLR, in both de-novo lesions and ISR.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Diabetes Mellitus , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Sirolimus/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Infarto del Miocardio/epidemiología , Infarto del Miocardio/etiología , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Diabetes Mellitus/inducido químicamente , Sistema de Registros , Reestenosis Coronaria/epidemiología , Reestenosis Coronaria/etiología
8.
JACC Case Rep ; 29(3): 102191, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38361557

RESUMEN

An 81-year-old woman presented with acute pulmonary edema. Echocardiography revealed severe functional mitral regurgitation, the mechanism of which was unusual. An atypical bileaflet tethering caused by disharmonic annular remodeling, concomitant aortic dilatation, and reduced aorto-mitral angle without left ventricular dysfunction or dilatation was found. A transcatheter edge-to-edge repair was nonetheless successfully performed.

10.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38276659

RESUMEN

BACKGROUND: Current European guidelines support transcatheter aortic valve implantation (TAVI) in intermediate-to-low-risk patients ≥75 years-old, but its prognostic relevance is unknown. METHODS: Intermediate-to-low-risk (The Society of Thoracic Surgeons score <8%) patients enrolled in the HORSE registry were included. We compared the populations aged under 75 with those over 75. The primary endpoint was all-cause mortality. RESULTS: A total of 2685 patients were included: 280 (8.6%) < 75 and 2405 ≥ 75 years. Through a mean follow-up of 437 ± 381 days, 198 (8.2%) and 23 (8.2%) patients died in the two arms without statistically significant differences (log-rank p = 0.925). At Cox regression analysis, age did not predict the occurrence of all-cause death, neither as a continuous variable (HR 1.01, 95% CI 0.99-1.04, p = 0.294) nor dichotomizing according to the prespecified cutoff of 75 years (HR 0.97, 95% CI 0.63-1.51, p = 0.924). Time-to-event ROC curves showed low accuracy of age to predict all-cause mortality (area under the curve of 0.54 for both 1-year and 2-year outcomes). CONCLUSIONS: TAVI has comparable benefits across age strata for intermediate-to-low-risk patients. The age cutoff suggested by the current guidelines is not predictive of the risk of adverse events during hospital stays or of all-cause mortality through a mid-term follow-up.

11.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37957842

RESUMEN

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Dilatación , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis
12.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37138103

RESUMEN

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Válvula Aórtica/cirugía , Sistema de Registros , Diseño de Prótesis
15.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38056772

RESUMEN

INTRODUCTION AND OBJECTIVES: The PEACE study (Performance of a sirolimus-eluting balloon strategy in acute and chronic coronary syndromes) investigated for the first time whether a sirolimus-coated balloon (SCB) (Magic Touch, Concept Medical, India) is associated with different outcomes depending on whether it is used in acute coronary syndromes (ACS) or chronic coronary syndromes (CCS). METHODS: This was a post-hoc analysis from the all-comers EASTBOURNE Registry (NCT03085823). Out of 2083 patients enrolled, an SCB was used to treat 968 (46.5%) ACS and 1115 (53.5%) CCS patients. The primary endpoint was target lesion revascularization at 12 months, while secondary endpoints were angiographic success and major adverse cardiovascular events. RESULTS: Baseline demographics, mean reference vessel diameter and mean lesion length were comparable between ACS and CCS. Predilatation was more commonly performed in ACS (P=.007). SCB was inflated at a standard pressure in both groups with a slight trend toward longer inflation time in ACS. Angiographic success was high in both groups (ACS 97.4% vs CCS 97.7%, P=.820) with limited bailout stenting. Similarly, at 12 months the cumulative incidence of target lesion revascularization (ACS 6.6% vs CCS 5.2%, P=.258) was comparable between ACS and CCS. Conversely, a higher rate of major adverse cardiovascular events in acute presenters was mainly driven by myocardial infarction recurrencies (ACS 10.4% vs CCS 8.3%, P=.009). In-stent restenosis showed a higher proportion of target lesion revascularization and major adverse cardiovascular events than de novo lesions, independently of the type of presentation at the index procedure. CONCLUSIONS: This SCB shows good performance in terms of acute and 1-year outcomes independently of the clinical presentation.

18.
Artículo en Inglés | MEDLINE | ID: mdl-37931791

RESUMEN

Percutaneous closure of a patent foramen ovale (PFO), a common variation of interatrial septum anatomy, is a commonly performed procedure in the catheterization laboratory to reduce the risk of recurrent stroke in selected patients and to treat other PFO-related syndromes. In the last twenty years, disc-based devices have represented the armamentarium of the interventional cardiologist; recently, suture-based devices have become an attractive alternative, despite limited data regarding their long-term performance. The present review gives an overview of the current evidence regarding suture-based PFO closure, the device's characteristics, the echocardiographic evaluation of the PFO anatomy, and recommendations for patient selection. A detailed procedural guide is then provided, and potential complications and future developments in the field are discussed.

19.
Catheter Cardiovasc Interv ; 102(6): 1048-1056, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37933728

RESUMEN

BACKGROUND: Percutaneous treatment for ostial left circumflex artery (LCx) lesions is known to be associated with suboptimal results. AIMS: The present study aims to assess the procedural and long-term clinical outcomes of percutaneous coronary intervention (PCI) for de novo ostial LCx lesions overall and according to the coronary revascularization strategy. METHODS: Consecutive patients undergoing PCI with second generation drug eluting stents or drug coated balloons for de novo ostial LCx lesions in three high-volume Italian centers between 2012 and 2021 were retrospectively evaluated. The primary endpoint was target-vessel revascularization (TVR) at 2 years. Secondary endpoints included major adverse cardiovascular and cerebrovascular events (MACCE), target lesion revascularization, myocardial infarction, stroke, all-cause death, and repeat revascularization. RESULTS: A total of 366 patients were included in the analysis with a median follow-up of 901 (IQR: 450-1728) days. 79.5% of the patients were male, 33.6% were diabetic, 49.7% had a previous PCI, and 23.1% a prior surgical revascularization. Very ostial LCx stenting was performed in 34.1%, crossover from left main to LCx in 17.3%, and a two-stent strategy in 48.6% of cases, respectively. In the overall population, the incidence of TVR at 2 years was 19.0% while MACCE rate was 25.7%. No major differences in clinical outcomes were found according to the stenting strategy. Use of intracoronary imaging was associated with fewer MACCE (HR: 0.47, 95% CI: 0.25-1.13, p = 0.01), while the diameter of the stent implanted in the ostial LCx was associated with less TVR (HR: 0.43, 95% CI: 0.25-0.75, p = 0.002). CONCLUSIONS: Percutaneous revascularization of the ostial LCx is associated with a high rate of TVR, regardless of the stenting strategy. Intracoronary imaging and proper stent sizing may reduce the failure rates.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Angiografía Coronaria/métodos
20.
Circ Cardiovasc Interv ; 16(12): e013232, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37874646

RESUMEN

BACKGROUND: Drug-coated balloons (DCB) are an emerging tool for modern percutaneous coronary intervention (PCI), but evidence on their use for de novo lesions on large vessels is limited. METHODS: Consecutive patients undergoing DCB-based PCI on the left anterior descending artery in 2 Italian centers from 2018 to 2022 were retrospectively enrolled and compared with patients who received left anterior descending PCI with contemporary drug-eluting stents (DES). In-stent restenosis was excluded. The DCB group included both patients undergoing DCB-only PCI and those receiving hybrid PCI with DCB and DES combined. The primary end point was target lesion failure at 2 years, defined as the composite of target lesion revascularization, cardiac death, and target vessel myocardial infarction. RESULTS: We included 147 consecutive patients undergoing DCB-based treatment on the left anterior descending artery and compared them to 701 patients who received conventional PCI with DES. In the DCB group, 43 patients (29.2%) were treated with DCB only and 104 (70.8%) with a hybrid approach; DCB length was greater than stent length in 55.1% of cases. Total treated length was higher in the DCB group (65 [40-82] versus 56 [46-66] mm; P=0.002), while longer DESs were implanted (38 [24-62] versus 56 [46-66] mm; P<0.001) and a higher rate of large vessels were treated (76.2% versus 83.5%; P=0.036) in the DES cohort. The cumulative 2-year target lesion failure incidence was not significantly different between the 2 groups (DCB, 4.1% versus DES, 9.8%; hazard ratio, 0.51 [95% CI, 0.20-1.27]; P=0.15). After a 1:1 propensity score matching resulting in 139 matched pairs, the DCB-based treatment was associated with a lower risk for target lesion failure at 2 years compared with DES-only PCI (hazard ratio, 0.2 [95% CI, 0.07-0.58]; P=0.003), mainly driven by less target lesion revascularization. CONCLUSIONS: A DCB-based treatment approach for left anterior descending revascularization allows a significantly reduced stent burden, thereby potentially limiting target lesion failure risk at midterm follow-up.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Stents Liberadores de Fármacos/efectos adversos , Resultado del Tratamiento , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Vasos Coronarios/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Materiales Biocompatibles Revestidos , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...