Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Pediatr ; 23(Suppl 2): 569, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37968578

RESUMEN

BACKGROUND: Millions of newborns die annually from preventable causes, with the highest rates occurring in Africa. Reducing neonatal mortality requires investment to scale hospital care, which includes providing hospitals with appropriate technology to care for small and sick newborns. Expensive medical devices designed for high-resource settings often fail to withstand conditions in low-resource hospitals, including humidity, dust, frequent user turnover, complex maintenance, lack of stable power, or difficulty sourcing expensive consumables. Rigorous evaluation protocols are needed to identify effective, affordable, rugged, and easy-to-use medical devices appropriate for quality hospital-based newborn care in low-resource hospitals. METHODS: We developed an evidence-based technology review process to identify medical devices suitable for small and sick newborn care in low-resource hospitals. The eight-step process consists of: identifying devices needed for effective newborn care; defining Target Product Profiles (TPPs); identifying commercially-available products that may meet TPPs; conducting desk research to evaluate technologies against TPPs; performing technical performance verification testing under laboratory conditions; verifying technical performance after exposure to heat, humidity, dust, and power loss; performing usability evaluations with nurses, and qualifying devices that pass all steps. Devices were purchased, installed, and monitored in newborn wards across Kenya, Malawi, Nigeria, and Tanzania. RESULTS: Of 271 devices considered, only 45 (16.6%) met corresponding TPPs based on desk research. Thirty-nine were purchased and evaluated in the laboratory; five (12.8%) failed to meet TPPs. Thirty-four products passing laboratory evaluation underwent short-term environmental testing; only one (2.9%) device failed. Thirty-seven products underwent usability testing with 127 clinicians; surprisingly, 14 (37.8%) failed to meet TPPs. Twenty-three products passed all evaluations, and 2457 devices were installed across 65 newborn wards in Kenya, Malawi, Nigeria, and Tanzania. Continuous device monitoring reported minimal device failures, with failed devices typically returned to service within two days, resulting in an average uptime (service days divided by days installed) of 99%. CONCLUSION: An evidence-based device selection process can improve procurement of effective, affordable, rugged, usable newborn care devices for low-resource hospitals, and feedback to manufacturers can improve device quality. Similar processes could be adapted beyond newborn care to identify medical devices suitable for implementation in any low-resource setting.


Asunto(s)
Cementerios , Hospitales , Recién Nacido , Humanos , Mortalidad Infantil , Kenia , Polvo
2.
PLOS Glob Public Health ; 3(8): e0002262, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37552665

RESUMEN

Neonatal jaundice is an important cause of morbidity and mortality worldwide, and neonates born in low and middle-income countries bear a disproportionate burden. We previously developed a low-cost, point-of-care system to measure total serum bilirubin (TSB) in neonates. This device was effective at detecting and monitoring jaundice; however, the disposable strips were difficult to produce at scale. Here, we report a new lateral flow cassette design, called BiliDx, that was produced at scale using traditional manufacturing techniques. We evaluated the performance of BiliDx at sites in Nigeria and Malawi. The lateral flow strip consists of plasma separation membranes, nitrocellulose, and a plastic cassette. We evaluated the performance of the strips and reader at two hospitals located in Nigeria and Malawi compared to reference standard TSB. We also assessed performance for samples with high direct bilirubin (DB) and high hematocrit (HCT). We collected 1,144 samples from 758 neonates (TSB ranged from 0.2 to 45.9 mg/dL). The mean bias of BiliDx measurements in the validation set was +0.75 mg/dL, and 95% limits of agreement were -2.57 to 4.07 mg/dL. The mean bias and limits of agreement were comparable for samples with HCT < 60% and HCT ≥ 60%, and for samples with low and intermediate DB levels; the samples with high DB levels had wider 95% limits of agreement (-4.50 to +3.03 mg/dL). Error grid analysis shows that 96.9% of samples measured with BiliDx would have resulted in the same clinical decision as the reference standard. This performance is comparable to previous results that used a handmade two-dimensional strip. Additionally, error grid analysis shows that all 20 samples with high DB levels would have resulted in the same clinical decision as the reference standard. This evaluation supports the use of BiliDx lateral flow cassettes to provide accurate point-of-care measurements in low-resource settings.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...